30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

30RB /30RQ

30KAV Variable Speed Air-cooled Screw Chiller

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: kw 30RQ: Nominal cooling capacity:

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-to-Water Heat Pump

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

30RB/RQ 039S-160S Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump

30XA Air-Cooled Liquid Chillers. Nominal cooling capacity kw

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: 18.8~35.5 kw 30RQ: Nominal cooling

38RBS Air-Cooled Condensing Units. Nominal cooling capacity: kw. Features. Easy and fast installation

38RBS Air-Cooled Condensing Units. product selection data. commercial and industrial applications. compact design.

30XAS Air-Cooled Liquid Chillers PRO-DIALOG + Nominal cooling capacity kw. Features and advantages. Very economical operation

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

30XAS A Air-Cooled Liquid Chillers. Nominal cooling capacity kw 50 Hz. Features and advantages. Very economical operation

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30RB /30RQ

61AF High-Temperature Monobloc Air-to-Water Heat Pumps with Integrated Hydronic Module. Nominal heating capacity kw.

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

30RB /30RQ

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

30RB/RQ Air-Cooled Liquid Chillers/Air-to-Water Heat Pumps. product selection data

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module PRODUCT SELECTION DATA. Compact design

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

30RH B Nominal cooling capacity kw Nominal heating capacity kw

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw

30RB A /30RQ

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

AR Ductable Air-Cooled Liquid Chillers Ductable Reversible Air-to-Water Heat Pumps

AQUASNAP JUNIOR 30RHV

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

30HXC Nominal cooling capacity kw

30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw

3 0 H X C A - H P 2

AQUASNAP AIR CONDITIONING MADE SIMPLE 30RA/30RH AQUASNAP LIQUID CHILLERS HEAT PUMPS

30RB/RQ Modular Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump

30RB C Series Air-Cooled Liquid Chiller

30GX 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

30RBM/30RBP AIR-COOLED SCROLL CHILLERS WITH GREENSPEED INTELLIGENCE PRODUCT SELECTION DATA

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

30HX GLOBAL CHILLER LIQUID CHILLER IN HARMONY WITH THE ENVIRONMENT

.2 Section Waste Management and Disposal.

30XW Water-Cooled Liquid Chiller

MISSING 30XB / 30XBP AIR-COOLED FIXED-SPEED SCREW CHILLER PRODUCT SELECTION DATA

High COP. Water-Cooled Screw Chiller

eco Touch Premium Toshiba Airconditioning March 2016 For more details, please contact our sales office:

Due to its inherent characteristics, Screw Compressor has the highest volumetric efficiency, de-rating at higher temperature is negligible.

Call us today! (800)

30XA Air-Cooled Liquid Chillers. Nominal cooling capacity kw. Features and advantages. Very economical operation

Leadership, Innovation, Advanced Technology Synergise Here!

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Modular Air Cooled Scroll Chillers

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

30RBM/30RBP Air-Cooled Scroll Chillers with Greenspeed Intelligence PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Low sound level

Product Data. Features/Benefits ComfortLink control

Call us today! (800)

Call us today! (800)

30XW Water-Cooled Liquid Chiller

Neosys Product catalogue

HYDROCIAT LW. Use. Range. Water chillers Heat pump. Cooling capacity kw Heating capacity kw. HYDROCIAT LW, ST series

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

30RBM/30RBP Air-Cooled Scroll Chillers with Greenspeed Intelligence PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Low sound level

LIQUID CHILLER HEAT PUMP kw 30RB/30RQ - R410A. A Multi-Talented Performer

30RBV/30RQV Inverter Air-Cooled Liquid chillers & Reversible Air to Water Heat Pumps PRODUCT SELECTION DATA INSTALLATION, OPERATION AND

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

Unit with optional hydronic module 61WG/30WG. Nominal cooling capacity kw Nominal heating capacity kw

30XW-V/30XWHV. Variable-Speed Water-Cooled Liquid Chillers/ Variable-Speed-Water-to-Water Heating Units

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

30XW-V/30XWHV. Variable-Speed Water-Cooled Liquid Chillers/ Variable-Speed-Water-to-Water Heating Units

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Be sustainable while protecting your business

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

19DV Back-to-Back Centrifugal Liquid Chiller with PUREtec TM Refrigerant and Greenspeed TM Intelligence

Renewables High-Temperature Monobloc Air-t nobloc Air oc Air o t -Wat W er Heat P ater He umps er Heat Pum mps

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by:

Conditioning your ambient, maximising your comfort.

Ductable Range of Air Conditioners

DAIKIN Huizhou Factory Profile

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Screw Chillers. High on reliability. Low on operating cost.

Air Cooled Scroll Chiller

CASE STUDY AIR-CONDITIONERS

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

30GN FLOTRONIC II AIR-COOLED CHILLERS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

SINGLE SCREW AIR COOLED CHILLER-HEAT RECOVERY

H4T R410A. refrigerant

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

61WG/30WG/30WGA. Water-Cooled and Condenserless Liquid Chillers Water-Sourced Heat Pumps. product selection data. 30WG optimized for cooling

Transcription:

THE FORCE IS WITHIN

Carrier India Carrier is a part of UTC Building & Industrial Systems, a unit of United Technologies Corp.(UTC), a leading provider to the aerospace and building systems industries worldwide. UTC was ranked at 151 st position in Fortune 500 list of global corporations in 2014. Built on Dr. Willis Carrier s invention of modern air conditioning in 1902, Carrier s research, expertise and innovation have resulted in market leading solutions. We recognize the vital importance of maintaining a responsible balance between the comfort we create today and the world we live in tomorrow. Millions of people trust Carrier s leadership in delivering efficient solutions. To know more, please visit http://www.carrier.com. Dr. Willis Carrier Over the years, Carrier India has significantly contributed in promoting sustainability. Carrier is the only company in the world to be a founding member of the Green Building Councils of the U.S., Argentina, China, India, Singapore and France. In fact, Carrier was instrumental in launching the U.S. Green Building Council (USGBC) in 1993 and was the first company in the world to join the organization. It invests in R&D resources to advance energy efficiency, ozone layer protection and low global warming technologies in its products. Carrier s AdvanTE 3 C Solutions Center is a natural evolution of Carrier's approach to sustainability and supports customers around the world in developing strategic, energy-efficient and custom-engineered building solutions. Carrier s efforts in promoting sustainability can be quantifiably measured by means of the Carrier CO2NSERVATION Meter, which meticulously calculates the avoided greenhouse emissions with the help of Carrier products, globally since 2000. To know more about the Carrier CO2NSERVATION Meter, please visit http://www.naturalleader.com. ACE(Achieving Competitive Excellence) is our proprietary operating system to ensure world-class quality in our products and processes. With its relentless focus on increasing efficiency and reducing waste, ACE is integral to the company's performance model.the company s facilities worldwide are using the operating system to improve quality and customer satisfaction while lowering cost. Carrier s presence in India dates back to 1986, when Carrier India was established. In the year 1988, the first manufacturing facility was commissioned in Gurgaon, Haryana. Spread in an area of 19 acres, this state-of-the-art facility consists of highly automated manufacturing unit, an excellent R&D Center and an advanced Quality Clinic. Currently, products manufactured in this facility include Cassettes, Ducted Splits, Package Units, Air Cooled & Water Cooled Screw Chillers, Air Cooled & Water Cooled Reciprocating Chillers, Fan Coil Units, Air Handling Units, Refrigeration products and Fire & Security products. Snapshots of Carrier India manufacturing facility Our comprehensive Environment, Health & Safety (EH&S) program establishes a framework and provides tools for implementing our EH&S practices into our business & culture. The Carrier Gurgaon facility holds a distinctive record of delivering over 17 million man hours without a lost work day incident, clearly citing the measures of safety followed here. Carrier India has 14 sales and service offices, more than 800 sales and service channel partners - throughout the country, ensuring efficient solutions and quality services at customer s doorstep. To know more visit http://www.carrierindia.com.

CARRIER STRENGTH: Progressing All Technologies Simultaneously The main Carrier objective is to achieve the optimal balance between technological progress - synonymous with performance - and environmental care - the guarantee for our future. Carrier's strategy for the development of new products concentrates on three essential aspects: - Minimising their impact on the environment - Increasing their reliability and durability - Raising the energy efficiency in response to latest regulations The Aquaforce range is available in 22 models from 278 to 1518 kw and offers the best solution for any individual projects and site requirements.

Economical operation - Average Full Load COP of 3.2 at nominal conditions and average integrated part load value (IPLV) of 4.4. - New twin-rotor screw compressor equipped with a high efficiency motor and a variable capacity valve that permits exact matching of the cooling capacity to the load. - Flooded multi-pipe evaporator to increase the heat exchange efficiency, configured with aluminium cladding (option) to improve thermal insulation and prevent energy loss. - Electronic expansion device allows operation at a lower condensing pressure and improved utilization of the evaporator heat exchange surface (superheat control). - Economizer system with electronic expansion device permits a considerable increase in cooling capacity and contributes to optimised energy efficiency of the chiller installation. Features a Economizer system Quiet operation Compressors - Discharge dampers integrated in the oil separator (Carrier patent). - Acoustic compressor and oil separator enclosures (option) reduce the radiated noise. Condenser section - Condenser coils in V-shape with an open angle, allows quieter air flow across the coil. - Low-noise Flying Bird fans (Carrier patent) enjoy quieter operation and never generate intrusive low-frequency noise. - Rigid fan mounting prevents start-up noise (Carrier patent). Made in state-of-the New twin screw CARRIER compressor Patented Flying Bird IV axial flow low noise fan Safe operation - Overload and lock rotor protection - Reversal/ phase losing protection - Protection of the compressor motor against high temperature - High pressure switch for compressor protection - Low current and short circuit protection - High pressure safety valve installed on oil separator Safety valve on the evaporator shell - Flow switch installed on the water box 2

nd Benefits Environmentally sound HFC-134a refrigerant - Refrigerant of the HFC group with zero ozone depletion potential. Leak-tight refrigerant circuit - Reduction of leaks as no capillary tubes and flare connections are used. - Verification of pressure transducers and temperature sensors without transferring refrigerant charge. a Easy and fast installation Victaulic connections simplify the onsite installation Simplified electrical connections - Main disconnect switch with high trip capacity. - Transformer to supply the integrated control circuit (400/24V). Fast commissioning - Factory charged refrigerant and oil - Systematic factory operation test before shipment. - Quick-test function for step-by-step verification of the instruments, expansion devices, fans and compressors. Absolute reliability -art Carrier India facility Screw compressors - Industrial-type screw compressors with oversized bearings and motor cooled by suction gas. - All compressor components are easily accessible on site minimizing down-time. - Electronic motor protection against overloads and power supply faults (loss of phase, phase reversal). Evaporator - Thermal insulation with aluminium cladding (option) for perfect resistance against outside aggression(mechanical and UV protection). Exceptional endurance tests - Partnerships with specialised laboratories and use of limit simulation tools (finite element calculation) for the design of critical components. - Transport simulation test in the laboratory on a vibrating table. The test is based on a military standard and equivalent to 4000 km by truck. - Salt mist corrosion resistance test in the laboratory for increased corrosion resistance. - Capable to operate at 55 o C outdoor air temperature based on chilled water temperature LWT Compressor ON Set point Adjustable control deadband Compressor OFF Cooler aluminium protective cladding (Optional) 3

Pro-Dialog Plus Control Pro-Dialog Plus combines advanced control logic with simple operation. The control system monitors all operation parameters all the time and precisely manages the operation of compressors, electronic expansion devices, fans for optimized energy efficiency. Pro-Dialog Plus interface Pro-Dialog Plus with touch screen User-friendly interface - The new backlighted LCD interface includes a manual control potentiometer to ensure legibility under any lighting conditions. The information is in clear text and can be displayed in English. - Unit uses intuitive tree-structure menus, similar to the internet navigators. They are user-friendly and permit quick access to the principal operating parameters: number of compressors operating, suction/discharge pressure, compressor operating hours, set point, air temperature, entering/leaving water temperature. - Large touch screen user interface offers intuitive access to the operating parameters. The information is in clear text and can be displayed in English. Advanced control function - Unit provides different control mode including LOCAL/REMOTE/CCN. - Remote control function including: Unit ON/OFF, dual set point control, 2-level demand limit control, user safety interlock, water pump operation control, operation indication, circuit alarm and alert etc. - Automatic reset of leaving water temperature based on return water temperature or outside air temperature to ensure optimized energy efficiency. - Control algorithm prevents excessive compressor cycling and permits reduction of the water quantity in the hydronic circuit (Carrier patent). - Automatic compressor unloading in case of abnormally high condensing pressure. If an abnomal incident occurs (e.g. fouled condenser coil, fan failure), Aquaforce continues to operate, but at reduced capacity. Powerful Diagnostics - A quick test of all unit components and control points to verify the correct operation of every switch, circuit breaker, contactor etc. at the start of the chiller. - Real-time monitoring of all the operation parameters, and alarm when necessary. - Control system is facilitated with RS485 serial communication port for remote diagnosis or special diagnostic tools. Sufficient safety measures - Password protection in case of mishandling. - Unit is protected against: Loss of refrigerant charge, reverse rotation, low chilled water temperature, low oil pressure (per compressor), current imbalance, compressor thermal overload, excessive air temperature, high pressure, electrical overload, loss of phase. Group control - Master/slave control of two chillers connected to automatically balance operating times, and also automatically conduct change-over in case of a unit fault. - Communication with other Building Management System (BMS) by selecting BacNet/J-Bus/LonTalk gateway. 4

Options & accessories Options No. Description Advantages Blygold PoluAL 002B Coil with factory-applied Blygold PoluAL treatment Improved corrosion resistance, recommended for heavy marine and industrial environments Gold Fin 003A Fin made of pre-treated aluminium (polyurethane and epoxy) Improved corrosion resistance, recommended for light marine environments Medium brine* 005 Leaving water temperature down to -6 C For low temperature applications such as ice storage, cold stores or process cooling etc. Low noise 015 Compressor sound enclosure Low operating noise IP54 020A IP 54 electrical box protection Improved electrical box protection, recommended for dusty / sandy environments * Available with select models 30XA0452/0502/0602/0702/0752/0852/0902/1002/1352/1502 Evaporator Water Pressure Drop Pressure drop, kpa 100 90 80 70 60 50 40 30 20 1 0282/0342 2 0452 3 0442/0482 4 0502 5 0602 1 2 3 4 5 Pressure drop, kpa 100 90 80 70 60 50 40 30 20 1 0702 2 0752 3 0852 4 0902 5 1002 6 1352 7 1502 1 2 3 4 5 6 7 10 10 20 30 40 50 Water flow rate, l/s 10 10 20 30 40 50 60 70 80 90 100 Water flow rate, l/s 100 Water pressure drop, kpa 90 80 70 60 50 40 30 20 652/712/762 1052/1152/1252 1312/1392 1 2 3 10 10 20 30 40 50 60 70 80 90 100 Water flow rate l/s 5

Technical Specifications Unit with Cu/Al condenser coil 30XA 0282 0342 0442 0452 0482 0502 0602 0652 0702 0712 0752 nominal cooling capacity* kw 278 328 444 452 493 503 619 644 674 697 729 Compressor input power kw 78.8 90.5 133.7 129.8 143.3 141.3 175.3 190.4 188.8 205 213.5 Fan and control power kw 8.4 9.8 11.8 11.8 14.6 14.0 16.8 15.6 19.0 16.9 20.2 COP 3.19 3.27 3.05 3.19 3.12 3.24 3.22 3.13 3.24 3.15 3.12 Refrigerant HFC-134a Circuit A kg 97 102 113 85 119 102 102 180 100 185 129 Circuit B kg - - - 56-56 88-95 - 88 Circuit C kg - - - - - - - - - - - Compressor Semi-hermetic screw compressor Circuit A 1 1 1 1 1 1 1 1 1 1 1 Circuit B - - - 1-1 1-1 - 1 Circuit C - - - - - - - - - - - Minimum capacity % 30 30 30 15 30 15 15 30 15 30 15 Control Condenser Fans Pro-Dialog Plus, electronic expansion valve (EXV) Cu/Al heat exchanger Axial Flying Bird with rotating shround Quantity 5 6 7 8 8 9 11 10 12 11 13 Total air flow m 3 /s 22.6 27.1 31.6 36.1 36.1 40.6 49.7 45.1 54.2 49.7 58.7 Fan speed rpm 950 950 950 950 950 950 950 950 950 950 950 Evaporator Flooded multi-pipe Water content l 49 54 76 70 77 77 79 78 94 78 99 Nominal water flow l/s 13.3 15.6 21.2 21.5 23.5 24.0 29.5 31 32.1 33 34.8 Nominal water pressure drop kpa 22 29 34 38 41 36 46 33 37 43 38 Max. water-side pressure without hydronic module Water connection kpa 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 Victaulic Nominal Diameter DN 125 125 125 125 125 125 125 150 150 150 150 Electrical data Nominal power supply Start-up method 400V-3Ph-50Hz Star-delta start Control power supply 24V via internal transformer Nominal unit current draw Circuit A+B A 147 173 262 238 273 264 320 336 346 363 404 Circuit C A - - - - - - - - - - - Maximum unit current draw Circuit A+B A 180 229 314 316 367 350 423 415 457 452 512 Circuit C A - - - - - - - - - - - Maximum start-up current Circuit A+B A 275 308 504 510 587 510 583 629 616 629 782 Circuit C A - - - - - - - - - - - Unit length m 3.6 3.6 4.8 4.8 4.8 6.0 7.2 6.0 7.2 7.2 8.4 Unit width m 2.3 22.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 Unit height m 2.3 22.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 Unit weight kg 3523 3820 4571 4823 4900 5393 6392 5250 6544 5916 7331 Operating weight kg 3578 3875 4641 4900 4984 5470 6480 5328 6640 5994 7430 * Nominal conditions - evaporator entering/leaving water temperature 12/7 o C, outdoor air temperature 35 o C; Evaporator fouling factor 0.018m 2 K/kW 6

Technical Specifications Unit with Cu/Al condenser coil 30XA 0762 0852 0902 1002 1052 1152 1252 1312 1392 1352 1502 Nominal cooling capacity* kw 737 833 906 988 1089 1134 1254 1325 1382 1449 1518 Compressor input power kw 215.4 238.8 261.4 288.2 318 332 373 395 415 435.4 436.8 Fan and control power kw 18.2 23.0 24.9 26.7 27.4 29.1 30.4 31.2 31.2 30.8 40.3 COP 3.16 3.18 3.16 3.14 3.16 3.15 3.11 3.11 3.10 3.11 3.18 Refrigerant HFC-134a Circuit A kg 195 130 129 140 180 180 190 185 185 112 140 Circuit B kg 95 103 129 110 114 114 180 185 98 129 Circuit C kg - - - - - - - 117 130 Compressor Semi-hermetic screw compressor Circuit A 1 1 1 1 1 1 1 1 1 1 1 Circuit B 1 1 1 1 1 1 1 1 1 1 Circuit C - - - - - - - 1 1 Minimum capacity % 30 15 15 15 15 15 15 15 15 10 10 Control Condenser Fans Pro-Dialog Plus, electronic expansion valve (EXV) Cu/Al heat exchanger Axial Flying Bird with rotating shround Quantity 12 14 15 16 17 18 19 20 20 20 24 Total air flow m 3 /s 54.2 63.2 67.7 72.2 76.7 81.3 85.8 90.3 90.3 90.3 108.3 Fan speed rpm 950 950 950 950 950 950 950 950 950 950 950 Evaporator Flooded multi-pipe Water content l 78 119 130 140 144 144 144 156 156 224 240 Nominal water flow l/s 35 39.7 43.2 47.1 52 54 60 63 66 69.1 72.4 Nominal water pressure drop kpa 51.4 39 38 36 41 45 57 53 60 45 48 Max. water-side pressure without hydronic module Water connection kpa 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 Victaulic Nominal Diameter DN 150 150 150 200 150 150 150 150 150 200/150 200/150 Electrical data Nominal power supply Start-up method 400V-3Ph-50Hz Star-delta start Control power supply Nominal unit current draw Circuit A+B Maximum unit current draw Circuit A+B Maximum start-up current Circuit A+B 24V via internal transformer A 383 446 516 546 568 590 658 697 730 537 546 Circuit C A - - - - - - - 275 273 A 479 596 635 734 722 769 830 864 884 678 734 Circuit C A - - - - - - - 364 367 A 629 815 905 954 1044 1044 1111 1122 1122 901 954 Circuit C A - - - - - - - 587 587 Unit length m 7.2 8.4 9.6 9.6 10.8 10.8 12.0 12.0 12.0 12.0 14.4 Unit width m 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 Unit height m 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 Unit weight kg 6002 7749 8487 8723 9108 9188 9723 10344 10344 11831 13156 Operating weight kg 6080 7870 8620 8870 9252 9332 9867 10500 10500 12060 13400 * Nominal conditions - evaporator entering/leaving water temperature 12/7 o C, outdoor air temperature 35 o C Evaporator fouling factor 0.018m 2 K/kW 7

Minimum Water Loop Volume For better control of leaving water temperature, the water loop minimum capacity is given by the formula: Water loop minimum capacity = Nominal system cooling capacity (kw) N Litres Application Normal air conditioning N 3.25 Process cooling 6.5 Where the nominal system cooling capacity (kw) is at the nominal operating conditions of the installation. This volume is necessary for stable operation and accurate temperature control. It is often necessary to add a buffer water tank to the circuit in order to achieve the required volume. The tank must be internally baffled in order to ensure proper mixing of the liquid (water or brine). Refer to the examples below. Bad Good Bad Good Field Control Wiring, 30XA Remote On/Off Dual set point Demand limit Cooling/heating switch(30xq only) Customer control system Safety alarm Alert Chiller status Water pump operation feedback Water pump control Auxiliary water pump control CCN communication bus 8

Operating Range, 30XA Cooling mode Evaporator Min.temperature Max.temperature Entering water temperature (at start) - 45 C Entering water temperature (during operation) 6.8 C 21 C Leaving water temperature (during operation) 3.3 C 15 C Condenser Min.temperature Max.temperature Outdoor air temperature -10 C 55 C* Note: A glycol/water solution or evaporator anti-freeze protection must be used if the air temperature is below 0 C or leaving water temperature is below 4 o C. * Max 55 C during part load operation, based on chilled water temperature. 9

1800 3000 3545 For more details, please contact our Carrier India sales office: Factory & Corporate Office: Carrier Airconditioning & Refrigeration Ltd, Kherki Daula Post, Narsingpur, Gurgaon 122004, Tel: 0124-4825500 Sales Offices: Delhi/NCR: 0124 2706000 Ghaziabad: 0120-4183260 Lucknow: 0522-4158703/4158710 Chandigarh: 0172-5007549/ 5007550 Jaipur: 0141-4109080 Indore: 0731-4070378 Mumbai: 022-61700700 Ahmedabad: 079-44820400 Pune: 020-67045100 Kolkata: 033-40524354 Chennai: 044-66448888 Bangalore: 080-43442000 Hyderabad: 040-41100222 Cochin: 0484-4029001/0 CIN: U74999HR1992FLC036104/ Website: www.carrierindia.com/ E-mail: bssindia@carrier.utc.com This catalogue provides certain general information and is intended for general guidance only and Carrier is not liable for any damage arising out of the use of the catalogue The Manufacturer reserves the right to change any product specification without prior notice