AC/DC Power Supply and Battery Charger Installation and Maintenance

Similar documents
Installing the Cisco ONS FAP-4 Fuse Alarm Panel

/9308 External Battery Chargers Installation Instructions

Installation and Operation Manual Low Power (LP) DC Power System

4100U City and Relay Cards Installation Instructions

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Greentrol Automation, Inc.

1U ULTRA Compact System

Installation Instructions for the LatitudeTM Solaris Stick Light Models SL8C-xxx

AMERIPHONE products are manufactured by Walker, A Division of Plantronics, Inc Western Avenue, Garden Grove, CA (800) VOICE

FUTURE CALL. Loud Ringer Light Box FC OWNER S MANUAL AND OPERATING INSTRUCTIONS

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

/ XPS Interconnection Diagrams

239 T1 HDSL4 Repeater (H4R) Installation and Maintenance Practice

Public Safety DAS Annunciator Panel

FUSE PANEL Technical Practice N N/L9 10/10 GMT NEBS Level 3 Certified

E N G L I S H SUPER PHONE RINGER MODEL SR-200 & SR-95 E S P A Ñ O L F R A N Ç A I S. Users Guide SR200 M52002 A 4/03

installation and operation manual for Hunter Ceiling Fans

12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker.

INSTALLATION INSTRUCTIONS

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

INSTALLATION INSTRUCTIONS

SC-6 Six Supervised Control Module

Optional Indoor Ceiling Mount Antenna Installation Instructions

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

CR85. Instruction Manual TONE

Noran Tel. FUSE PANEL Technical Practice N NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

FUSE PANEL. Technical Practice N N/L33 10/10 GMT Front Access NEBS Level 3 Certified

Series SPB Audio Boosters Installation, Testing, Operation, and Maintenance Manual

Light Level Detector, Surface Mount 5754PE. Installation Instructions

NetworX NX-548E Receiver Installation Instructions

Veritas Appliance Hardware Service Procedure

GDC 087R Issue 2 - May Installation and Operation UAS Shelf/Enclosure. General DataComm

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

23-IN Electric Logset

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Owner s Guide and Installation Manual

52 CEILING FAN. Owner s Manual Models #50336, 50337

ELECTRIC FLAT PANEL FIREPLACE HEATER

Concert Breeze s Manual

MILLA ELECTRIC FIREPLACE

Installation Instructions

4-Channel Contact Closure Fiber Link Card System

Cold Deck Canopy and Shelf Lights and Retrofit Kit

IDP-Zone-6 Six Zone Interface Module

APC BC300 Series 40kW 208/450/480V User Guide

CR24 INSTALLATION INSTRUCTIONS

52 BERKSHIRE CEILING FAN

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

Installation and user manual for the BiWire / Conventional Repeater Panel

Thermostats. Digital Programmable. GEAppliances.com

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

Owner s Guide and Installation Manual

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Summer Breeze Heater Service Manual

OSD10, OSD20 & OSD30 DRINK DISPENSER

Installation Instructions Wall Ovens

Remote NAC Power Supply D7038

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

MMF Six Zone Interface Module

Homeowner s Installation Instructions & Operating Manual

Rack Mount Series Installation Guide

INSTRUCTION MANUAL MNBX14

HUMIDITY SENSING BATH FAN

Installation Instruction Manual ILS-S

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Installation Instructions

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies

GRANDE OWNER S MANUAL

TECHNICAL INFORMATION Touchtronic Clothes Dryers

VENTILATION FAN WITH BLUETOOTH SPEAKER

Installation and Operation Guide

www. ElectricalPartManuals. com GADP Ground Fault Indication System Instruction Manual Ground Fault Protection

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

FUSE PANEL. Technical Practice N N/0803 5/5 GMT Front Access NEBS Level 3 Certified

Universal Fan and Light Remote Control

SECTION POWER SUPPLIES AND DISTRIBUTION

3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD

Room Sensor for BACnet VAV Actuator

Please Keep This Manual For Future Reference REV.01

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

Installation Instructions

BLOWER ACCESSORY MODEL #FIB100 Español p. 17

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

Gallery Electric Fireplaces

Long Range Radio Alarm Transmitter

OPERATING MANUAL CUSTOMER SERVICE NO

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

Installation & Operation Manual for WarmlyYours Towel Warmers

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

Transcription:

AC/DC Power Supply and Battery Charger Installation and Maintenance 61175043L3-5A Issue 1, January 2004 CLEI Code: SIMPAADA_ CLEI Code: SIMPAAGA_ CONTENTS 1. GENERAL... 1 2. DESCRIPTION... 1 3. INSTALLATION... 2 4. BATTERY BACKUP OPERATION... 4 5. COMPLIANCE CODES... 5 6. MAINTENANCE... 5 7. WARRANTY AND CUSTOMER SERVICE... 5 FIGURES Figure 1. AC/DC Power Supply and Battery Charger...1 Figure 2. Cable for OPTI-3, MX2810, and NIU3...3 Figure 3. Cable for the MX2800...4 TABLES Table 1. LED Indication... 2 Table 2. (OPTI-3, MX2810, NIU3)... 3 Table 3. Alarm Relay Operation... 4 1. GENERAL This practice provides installation and maintenance procedures for the ADTRAN AC/DC Power Supply and Battery Charger (PS/BC). Figure 1 is a front and back illustration of the PS/BC. Revision History This is the initial release of this document. Future revisions will be made in this subsection. Features Features of the PS/BC, P/N 1175043L3, include the following: Compact design. Versatile mounting arrangements. All mounting hardware included. Built-in fuse. Multi-feature status LED. Modular connections. Positive ground. Uninterrupted power output (if battery backup connected). FCC and UL 60950 compliant. Complies with GR-1089-CORE and GR-63-CORE. Figure 1. AC/DC Power Supply and Battery Charger 2. DESCRIPTION The AC/DC PS/BC provides -54 VDC to the Power Supply unit in various supported product systems. The PS/BC receives 115 VAC through a standard plug and wall socket. Some of the more common supported ADTRAN systems include: Total Access 750/850 Total Access OPTI-3 MX2800/2810 NIU3 (single mount housing, 3-slot shelf, 12-slot shelf) Battery Backup Units Refer to your product documentation to verify compatibility with the PS/BC. This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference that may cause undesired operation. Changes or modifications not expressly approved by ADTRAN could void the user s authority to operate this equipment. Fuse A 3 Amp fuse on the back panel protects the unit from over current. The fuse isolates the AC input from the power supply in the event of a fault. The fuse is replaced by twisting the 61175043L3-5A Trademarks: Any brand names and product names included in this document are 1 trademarks, registered trademarks, or trade names of their respective holders.

black cap to the left and pulling the fuse out. After the new fuse is inserted, the cap is pushed back in and turned to the right. Status LED A single multi-feature LED on the front panel provides AC operation or battery operation power status. Refer to Table 1 for indication descriptions. 3. INSTALLATION Table 1. LED Indication AC Power Operation Battery Operation Green OK Green OK (charging) Yellow Power Fail Yellow Discharging Red Power Fail Red Low (< 40V) Off Power Fail Off Disconnected CAUTION This equipment MUST only be installed in a DC-C bonding and grounding environment per Telcordia GR-1089-CORE, Issue 3. It may not be utilized in a DC-I (isolated) bonding and grounding environment. SAFETY INFORMATION When using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury: 1. Do not use this product near water, such as a bathtub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool. 2. Avoid using a telephone (other than a cordless-type) during an electrical storm. There is a remote risk of shock from lightning. 3. Do not use the telephone to report a gas leak in the vicinity of the leak. 4. Use only the power cord, power supply, and/or batteries indicated in the manual. Do not dispose of batteries in a fire; they may explode. Check with local codes for special disposal instructions. ELECTROSTATIC INSTRUCTIONS C A U T I O N! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. CAUTION Electronic equipment can be damaged by static electrical discharge. Before handling equipment, wear an antistatic discharge wrist strap to prevent damage to electronic components. Place equipment in antistatic packing material when transporting or storing. When working on equipment, always place them on an approved antistatic mat that is electronically grounded. After unpacking the unit, inspect it for damage. If damage is noted, file a claim with the carrier then notify ADTRAN Customer Service. MOUNTING AND WIRING INSTRUCTIONS The following are mounting instructions for the AC/DC PS/BC when utilized with some of the various ADTRAN product systems. If your ADTRAN system is not listed in this section, please refer to the documentation provided with your ADTRAN product system for more detailed instructions. Wallmounting For the wallmount arrangement, the PS/BC is normally installed on the designated 3/4-inch or thicker plywood with four #6 by 3/4-inch flat-head wood screws. Installation is as follows: 1. Determine the preferred layout and ensure the socketoutlet is located near the equipment and easily accessible. 2. Ensure the unit is plumb, then mark through the four screw holes to identify where the pilot holes will be drilled. 3. Using a 1/16-inch bit, drill pilot holes at the marked locations. 4. Mount the unit using the pan-head screws. 5. Route and connect all cabling to the appropriate device. Use cable tie-downs as needed. 6. Connect the ground stud using the most direct route to a known equipment ground source. Total Access 750/850 Mount the power supply on the left side of the Total Access 750/850 shelf (next to the battery cover hinge) for battery backup installations (P/N 1175044L2 and 1175044L4) Position the Total Access PSU (power cords oriented downward) and align all four holes (on the tabs at the corner of the Total Access PSU) with the four available machined holes on either side of the Total Access 750/850. Use four #6 3/8-inch machine screws (provided) to secure the Total Access PSU. Alternately, the Total Access PSU can be mounted to a backboard with four #6 3/4-inch wood screws (not supplied). Before beginning the wiring connection, verify that the Total Access 750/850 and the AC/DC Power Supply and Battery Charger are properly grounded with the required supplemental ground. Power should be the last connection made during installation. The Total Access PSU has two cords (AC plug and 4 position modular adapter). Insert the Total Access PSU modular 2 Issue 1, January 2004 61175043L3-5A

adapter into the receptacle provided on the back of the Total Access 750/850 and plug the AC plug into the AC power source. Total Access OPTI-3 An additional cable (ADTRAN P/N 1200657L10) is required for connecting the PS/BC to Total Access OPTI-3 systems. Rackmounted Systems Use a mounting bracket and secure the Total Access PSU to the rack (19 bracket P/N 1175050L1, 23 bracket P/N 1175051L1). Orient the Total Access PSU with the cables facing away from the center and secure it with four #6 3/8-inch machine screws. A single bracket mounts up to 4 Total Access PSUs. Alternately, mount the Total Access PSU directly to the rack (or a backboard) using two or more of the mounting tabs. Wallmounted Systems Position the Total Access PSU (power cords oriented downward) and align the outer two holes (on the tabs at the corner of the Total Access PSU) with the two available machined holes on either side of the Total Access OPTI-3. Use two #6 3/8-inch machine screws (provided) to secure the Total Access PSU. The Total Access PSU (when ordered for use with these systems) is shipped with an adapter cable (ADTRAN P/N 1200657L10) that has a molded modular connector on one end and three ring type terminals on the other (see Figure 2). Figure 2. Cable for OPTI-3, MX2810, and NIU3 The Total Access PSU powers a single bus (select either A or B). Connect the ring-type terminals to the respective terminals on the rear of the chassis using the screws provided. Use the following wiring conventions: RED BLACK GREEN -48VA or PWR RET Ground Terminal Table 2. (OPTI-3, MX2810, NIU3) MX2810 and NIU3 Systems An additional cable (ADTRAN P/N 1200657L10) is required for connecting the PS/BC to MX2810 and NIU3 systems. Rackmounted Systems Use a mounting bracket and secure the Total Access PSU to the rack (19 bracket P/N 1175050L1, 23 bracket P/N 1175051L1). Orient the Total Access PSU with the cables facing away from the center and secure it with four #6 3/8-inch machine screws. A single bracket mounts up to 4 Total Access PSUs. Alternately, mount the Total Access PSU directly to the rack (or a backboard) using two or more of the mounting tabs. The Total Access PSU (when ordered for use with these systems) is shipped with an adapter cable (ADTRAN P/N 1200657L10) that has a molded modular connector on one end and three ring type terminals on the other (see Figure 2). The Total Access PSU powers a single bus (select either A or B). Connect the ring-type terminals to the respective terminals on the rear of the chassis using the screws provided. Use the wiring conventions in Table 2. Connect the DC wiring harness of the Total Access PSU to the adapter using the modular connectors and plug the AC plug into the AC power source. MX2800 An additional cable (ADTRAN P/N 1200657L2) is required for connecting the PS/BC to MX2800 systems. Rackmounted Systems Use a mounting bracket and secure the Total Access PSU to the rack (19 bracket P/N 1175050L1, 23 bracket P/N 1175051L1). Orient the Total Access PSU with the cables facing away from the center and secure it with four #6 3/8-inch machine screws. A single bracket mounts up to 4 Total Access PSUs. Alternately, mount the Total Access PSU directly to the rack (or a backboard) using two or more of the mounting tabs. The Total Access PSU (when ordered for use with this system) is shipped with an adapter cable (ADTRAN Connect the DC wiring harness of the Total Access PSU to the adapter using the modular connectors and plug the AC plug into the AC power source. 61175043L3-5A Issue 1, January 2004 3

P/N 1200657L2) that has a molded modular connector on one end and four soldered wire tips on the other (see Figure 3). ground wire in a customer equipment room. 18 AWG or larger ground wire is recommended. 4. BATTERY BACKUP OPERATION The following information is applicable when using the PS/BC with any available ADTRAN BBU. Figure 3. Cable for the MX2800 Connect the soldered ends of the wires to the modular connector that fits into the chosen power bus using a small slotted screwdriver. (The power buses are labeled A and B on the rear of the chassis.) Use the following wiring conventions (holding the connector as it will be inserted in the chassis): Left WHITE Battery Backup Alarm Wire RED BLACK Negative Terminal Wire Positive (RET) Wire Right GREEN Ground Terminal Wire Secure the ends of the wires and plug the connector into the chassis on the desired power bus (A or B). Connect the other end to the DC wiring harness of the PSU wiring harness and plug the AC plug into the AC power source. Battery Backup Units When using the PS/BC in conjunction with available ADTRAN Battery Backup Units (BBUs), one of the following mounting options should be used: Wallmounting the PS/BC (refer to Wallmounting on page 2). the PS/BC to the product chassis containing the DC power supply. the PS/C to the BBU. Refer to your specific ADTRAN product system documentation to determine the optimal mounting solution for your system. GROUNDING INSTRUCTIONS For complete details on product grounding requirements, refer to the Network Turnup Procedure in your product System Manual. GR-1089-CORE Requirement An equipment grounding conductor that is not smaller in size than the ungrounded branch-circuit supply conductor is to be installed as part of the circuit that supplies the product or system. The ground connector on the PS/BC provides an additional ground reference (the third prong of the AC plug is also grounded) and may be connected to the ground bus or Alarm and Battery Disconnect Relays Two relays support Power Supply operation: Alarm relay Battery disconnect relay Alarm Relay and Alarm Signal The Alarm relay is provided for customer use. In normal operation the contact alarm relay is open. If an AC power failure occurs and the unit defaults to the battery backup, the relay will cycle open.closed once per second (that is one second open then one second closed). The tolerance on this cycle time is 25 percent. This indicates the battery is discharging in support of the load. If battery voltage decreases to 45 V the relay stays closed to indicate the battery is becoming depleted. The relay will open automatically when normal AC voltage is restored. Table 3 summarizes the alarm relay operation. Normal Table 3. Alarm Relay Operation Condition AC Power Failure/Battery Backup engaged Battery voltage is less than 40V Open Alarm Relay Cycles open/closed once per second Stays closed An alarm signal that cycles synchronously with the alarm relay is provided on the output cable. This signal, which is open during normal operation, cycles between open and ground during battery backup (as described for the alarm relay), and is ground when the battery voltage falls below 45V. Battery Fail Alarm For battery backup systems that employ the optional Battery Test Assembly an alarm signal is provided to the PS/BC that indicates a failed battery (in need of immediate replacement). This signal is passed to the Alarm Relay and Output Alarm Signal. When a failed battery is detected, it is indicated by the Alarm Relay cycling open for 450 ms, then closed for 450 ms. Battery failure is also indicated by the output alarm signal cycling open to ground at the same rate. Battery Disconnect Relay The battery disconnect relay disconnects the battery pack from the system if the battery voltage falls below 40 VDC. This feature prevents damage tot he batteries. The batteries 4 Issue 1, January 2004 61175043L3-5A

will be recharged when normal AC voltage is restored and the relay will close when the battery voltage exceeds 40V. Certain alarm features on the power supply are still powered by the battery after the disconnect relay is opened. These features slowly drain the battery. If it is known that AC power will be unavailable for an extended periods (greater than a week), ADTRAN recommends that the battery be disconnected from the power supply to prevent overdischarge. 5. COMPLIANCE CODES Code Input Output IC F C TC PC R 6. MAINTENANCE The AC/DC Power Supply and Battery Charger does not require routing maintenance for design operation. ADTRAN does not recommend that repairs be attempted in the field. Repair services are obtained by returning the defective unit to ADTRAN Customer Service. 7. WARRANTY AND CUSTOMER SERVICE All Total Access Battery Backup systems have a 10 year warranty coverage on the product. This includes cables, housings, PCBs, and any other ADTRAN-built components (excluding lead acid batteries). ADTRAN will repair and return this product within 10 years from the date of the shipment if it does not meet its published specifications or fails while in service (see ADTRAN Equipment Warranty, Repair, and Return Policy and Procedure, document 60000087-10A). For service, CAPS requests, or further information, contact one of the following numbers: ADTRAN Sales Pricing and Availability (800) 827-0807 ADTRAN Technical Support Pre sales Applications/Post-sale Technical Assistance (888) 4-ADTRAN Standard hours: Monday-Friday, 7 a.m.-7 p.m. CST Emergency hours: 7 days/week, 24 hours/day ADTRAN Repair/CAPS Return for repair/upgrade (256) 963-8722 Repair and Return Address ADTRAN, Inc. CAPS 901 Explorer Boulevard Huntsville, Alabama 35806-2807 61175043L3-5A Issue 1, January 2004 5

6 Issue 1, January 2004 61175043L3-5A