Thermo Scientific HERAsafe Microbiological Safety Cabinets Advanced operator and product protection

Similar documents
HERAEUS HERASAFE KS SAFETY CABINET CLASS II. Safety. Everything you need more than you expect

Setting new Standards for Safety Containment. Comfort. Convenience. Thermo Scientific HERASAFE KS and KSP Class II Biological Safety Cabinets

Thermo Scientific MSC-Advantage Class II Biological Safety Cabinets. Good for you, good for the environment

Thermo Scientific 1300 Series A2

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

Forma 1400 Series Class II, Type A2 Biological Safety Cabinet. Superior Ergonomics, Uncompromising Safety

Safely Using a Centrifuge Near a Biological Safety Cabinet in Your Cell Culture Laboratory

Thermo Scientific Lindberg Blue M Ovens. Superior performance and accuracy for your most demanding applications

Thermo Scientific Lindberg Blue M Ovens. Superior performance and accuracy for your most demanding applications

Thermo Scientific Heratherm Heating and Drying Ovens. efficient safe easy. Part of Thermo Fisher Scientific

Thermo Scientific Precision Ovens

Thermo Scientific Heraeus microbiological incubators An optimal environment for your samples

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

Thermo Scientific Heratherm Heating and Drying Ovens. Efficient, safe and easy

Efficient, safe and easy

Thermo Scientific Revco Value Freezers and Refrigerators. General Purpose Explosion Proof Flammable Material Chromatography

Thermo Scientific Heratherm Heating and Drying Ovens

NEW! TSX Series high-performance undercounter refrigerators

NEW! TSX Series high-performance undercounter refrigerators

Thermo Scientific Heratherm Microbiological Incubators

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

Heto PowerDry LL1500 Freeze Dryer

Innovation in air purification unmatched air quality

Down flow clean air cabinet Star of the Universe. Fortuna

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

Open the Door to Increased Productivity and Cost Efficiency

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

INCREASE YOUR LAB EFFICIENCY

LABORATORY CABINETS 103

ALMOST Rocket Science FORTUNA. Clean Air Cabinet. Vertical Laminar Flow Cabinet

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

INCREASE YOUR LAB EFFICIENCY

Faster BH-EN and BHG Class II Microbiological Safety Cabinets

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

INCREASE YOUR LAB EFFICIENCY

Thermo Scientific HERAfreeze Freezers Solutions for safe sample storage

ice 3000 Series Atomic Absorption Spectrometers

The KingFisher Family

Control Operating Costs. Gain Process Efficiency.

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

Microbiological Safety Cabinets

BioMAT 2 BioMAT 2-S2. Class 2 Microbiological. Safety Cabinets. Simple. Safe. Quiet. Efficient. To EN 12469:2000

Thermo Scientific Cryopreservation Equipment

Benchtop CO 2 Incubator. the Oasis 6400 series

Thermo Scientific Microm HM550 cryostat

ANIMAL RESEARCH PRODUCTS. Biological Safety Cabinets Animal Transfer Stations

PASSION THAT DRIVES PERFORMANCES. WASHINGSOLUTIONS

The ultimate microbiological safety cabinet

PRODUCT INFORMATION. SureSense THE SURE WAY TO DETECT ANY OBJECT. Photoelectric Sensors

Lower Your Costs. Expand Your Flexibility.

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

Environmental Health and Safety Biological Safety Program Guidance Document

Vacuum in the laboratory. products and solutions

Ergonomic and Green Class II s

Microbiological Safety Cabinets ENVAIR eco safe Comfort

Operating Instructions Safety Cabinet HERAsafe KS / KSP

CelCulture. Cradle for Beautiful Cells. CelCulture Water-Jacketed CO 2 Incubator

Maximum protection for your health and well-being

Forced Convection. Laboratory Ovens. Isotherm Forced Convection Laboratory Ovens, 110L, 54L and 32L models.

FagronLab NP-1 UV. Negative pressure workbench. User Manual

Microbiological Safety Cabinets ENVAIR eco safe Comfort Plus

INCREASE YOUR LAB EFFICIENCY

BARRIER TECHNOLOGY RABS & ISOLATORS FOR ASEPTIC PROCESSING

Technical Catalog laboratory furniture system

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

Labconco XPress Laboratory Equipment Where You Need It, When You Need It

DRI-AIR INDUSTRIES, INC. ARID-X10C FLOOR MOUNT DRYER OPERATING MANUAL

LAMINAR FLOW FOR ALL YOUR NEEDS

www

Cleanroom systems. Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow

Gelaire BH-EN and UltraSafe cabinets

intuitive intelligent interactive New! Thermo Scientific Heracell 150i and 240i CO 2 Incubators

INCREASE YOUR LAB EFFICIENCY

ENVAIR lab CO2 Incubator

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

Thermo Scientific Forma Steri-Cult CO2 Incubators High volume culturing and ultimate contamination control

Introducing The Reliance 200 and 250 Glassware Washing Systems.

Global Series Screw Air Compressors Life source of industries

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

Microbiological Safety Cabinets ENVAIR eco safe Basic Plus

Corning LSE 6L Digital Water Bath

Technical Catalog laboratory furniture system

Safe Operating Procedure (Revised 2/10)

2 Microbiological Safety Cabinet

FUNCTION LINE HEATING AND DRYING OVENS

NEW! Thermo Scientific Forma Rack and Accessory Guide For -40 C and -86 C Freezers. Optimize your freezer for maximum sample protection

BioSafety Cabinet- Class 100

Vacuum mixers Wamix-Classic and Wamix-Injector

DEKO Washer-disinfector WASHROOM SYSTEMS

1,000W (DAP-60K: 100 W per digestion vessel)

Thermo Scientific Heratherm Heating and Drying Ovens. efficient

VARIABLE SPEED DIRECT DRIVE CENTRIFUGAL AIR BLOWERS

Global Series Screw Air Compressors Life source of industries HP

Model KBWF 240 Growth chambers with light and humidity

INCREASE YOUR LAB EFFICIENCY

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

Model KBWF 720 Growth chambers with light and humidity

Oil Mist Separator Unit LGA 600 FUW

Transcription:

Thermo Scientific HERAsafe Microbiological Safety Cabinets Advanced operator and product protection Part of Thermo Fisher Scientific

Advanced Operator and Product Protection Thermo Scientific precision-engineered safety cabinets provide clean air solutions for a host of applications, ranging from routine work with potentially hazardous samples to handling cytotoxic compounds. Every cabinet provides the level of operator, product and environmental protection you need and every cabinet is designed to make working safely as easy and as comfortable as possible. Our Thermo Scientific HERAsafe safety cabinets are renowned for their performance, reliability and ease of use. They are functionally advanced, easy to clean and simple to maintain. The safety cabinets are also fully modular so with a broad range of options and accessories available, they can easily be configured to meet specific laboratory requirements. We bring a history of excellence to the design and manufacture of safety cabinets. We work closely with our customers to create and support safety cabinets that offer unmatched quality, precision and reliability. Our models are tested by independent organizations to national and international standards including: EN-12469: (09/00) DIN 12980: (06/05) EN-61010-1 No Operator Fatigue A relaxed working posture helps to prevent back and shoulder aches, so operators can work in comfort for hours at a time. Ergonomically designed arm rests ensure that the air suction vents are not inadvertently obstructed. A variety of floor stands are available as optional accessories to easily customize the working height for each individual user. In addition, the slanted front window allows for a comfortable working position. 2

Improved ergonomics maximizes safety Maximize contamination prevention: A mobile infrared control unit permits parameter setting from within the cabinet, so operators do not need to remove their hands from the sterile work area. Work Comfortably, Work Safely Thermo Scientific HERAsafe KS Class II Cabinets Our HERAsafe KS safety cabinets incorporate a range of revolutionary ergonomic design make safety cabinet operation simpler, easier and more comfortable, creating an inherently safer working environment. Motorized aerosol-tight front window Allows precise and easy operation of the front window. Seals the inner chamber for secure contamination protection for samples and personnel in stand-by mode Hinged front window allows full access to the interior for thorough cleaning/disinfection as well as easy load and unload of the work space Slanted front window and arm rests Support ergonomic working posture and minimize operator fatigue Mobile control unit allows users to keep hands within the sterile work area while parameter settings are changed Thermo Scientific HERAsafe KSP Class II Cabinets Our HERAsafe KSP models offer all the benefits of the HERAsafe KS, with added protection for hazardous applications. For applications with stringent safety requirements, an additional, segmented HEPA filter system purifies air 100,000 times more effectively resulting in the highest possible levels of sample, user and environmental protection when working with hazardous samples (e.g. cytotoxic compounds) in a Class II cabinet. HERAsafe KS page 4 HERAsafe KSP page 6 3

Thermo Scientific HERAsafe KS/KSP Cabinets Setting New Standards in Safety Cabinet Design Our HERAsafe KS/KSP models incorporate a range of innovations that you won t find in other safety cabinets. Every aspect of the cabinet is ergonomically designed to make operation simpler and more comfortable than ever before, creating an inherently safer working environment with maximized contamination prevention for your samples. Our HERAsafe KS safety cabinets are used wherever protection and safety are of paramount importance: Biotechnology Microbiology Pharmacy Clinics Aerosol-tight motor driven front window seals the inner chamber in closed position for optimum protection from contamination even in stand-by mode. The window height can be adjusted with a finger tip. Fully open, hinged front window allows total access to the interior for thorough cleaning/disinfection and the easy loading and unloading of items. Parameter setting via mobile control using the mobile control unit minimizes contamination risks, since hands are never removed from the clean air atmosphere. Eye-level digital display on rear wall no need to lean awkwardly to monitor status or read parameters during operation. HERAsafe KS Ergonomically Designed for Maximum Safety and Operator Comfort Save time, prevent contamination Use the mobile control unit inside a SAFEbag: change parameters quickly and make glove changes history. Work safely, work comfortably the aerosol-tight motor driven front window provides optimal protection, preventing contaminants from entering or leaving the work area. The window is sloped for a more comfortable working posture. Unobstructed, all-round visibility frameless front window and transparent glass side windows. Flexible configuration optional ports for gas, water and vacuum in side panels or rear wall. Adjustable stands configure the support stand for individual working height. Levelling feet securely position the cabinet. 4

Easy Cleaning The hinged front window gives easy access to the interior for cleaning and disinfection. The stainless steel work surface is scratchproof, acid-resistant and easy to clean. Additional, segmented HEPA filters purify the air inside the KSP cabinets 100,000 times more effectively Efficient Disinfection Powerful UV-C irradiators (optional) are available for efficient disinfection. Cross-beam radiation illuminates the entire work area without causing shadows thus ensuring thorough disinfection. At-a-glance monitoring the unique eye-level display on the rear wall eliminates the need to lean awkwardly to read parameters or check operational status. The display indicates downflow rate, total operating hours and alarms. The display also shows the PER Performance Factor, which advises the current safety status using a relative measure that considers air flow, operating time and filter status thus allowing an effective maintenance schedule. Better disinfection patented cross-beam UV irradiation (optional) illuminates the entire working area without causing shadows ensuring a thorough disinfection. HERAsafe KS 5

Comfortable Working Ergonomically designed arm rests allow the operator to work comfortably without obstructing the air vents. Taps for vacuum, gas, water and other media can be fitted to side panels or the rear wall. KSP Thermo Scientific HERAsafe KSP Cabinets 100,000 times higher safety While featuring all benefits of the previously described models KS, in addition our HERAsafe KSP Class II safety cabinets incorporate the newly-developed segmented HEPA filter system for significantly higher contamination protection when working with hazardous samples and materials. This additional filter system purifies inlet, supply and exhaust air 100,000 times more effectively than conventional 2-filter systems. Its outstanding efficiency means that supply and exhaust air filters do have an almost eternal life time. Reduced risk contamination of inner air ducts is virtually impossible. Easy maintenance filter cartridges can be replaced while the cabinet is in operation. Cartridges snap into position over a gasket. Safe, easy disposal filter cartridges can be disposed of by incineration. Airflow diagram of the HERAsafe KSP Maximum Sterility The additional segmented HEPA-filter is fitted beneath the work area, ensuring that all inner surfaces are kept sterile. The filter can be easily sealed and replaced under operating conditions with a significantly reduced contamination risk. HERAsafe KSP 6

Thermo Scientific Microbiological Safety Cabinets HERAsafe KSP Technical Specifications HERAsafe KSP Type Unit KSP 9 KSP 12 KSP 15 KSP 18 Dimensions External dimensions KSP 1) (w/h/d) mm 1000/2265/880 1300/2265/880 1600/2265/880 1900/2265/880 Internal dimensions (w/h/d) mm 900/780/627 1200/780/627 1500/780/627 1800/780/627 Minimum doorway (w) mm 800 800 800 800 Work aperture (h) mm 200 200 200 200 Max. lifting height of front window (not open) mm ~470 ~470 ~470 ~470 Working height (stand. support frame adjustable) mm 750 950 mm (support frame is adjustable in 50 mm steps) Weight Equipment kg ~240 ~290 ~320 ~350 Maximum load capacity of work surfaces for single module work surface kg 50 50 50 50 for segmented work surface kg 25 25 25 25 Ventilation system Exhaust air/inflow volume flow m 3 /h ~300 ~400 ~500 ~600 Air circulation flow rate flow m 3 /h ~600 ~830 ~1040 ~1170 Heat emission at 25 C room temperature kw ~0.2 ~0.2 ~0.4 ~0.4 Filter technology Forced air/exhaust air filter type HEPA H 14 EN 1822, 99.999% at 0.3 µm particle size Additional Exhaust Filter (AEF) type HEPA H 14 EN 1822, 99.999% at 0.3 µm particle size Performance Illumination lx > 1000 > 1000 > 1000 > 1000 Electrical data Voltage 2) V 1/N/PE 230 V AC 1/N/PE 230 V AC 1/N/PE 230 V AC 1/N/PE 230 V AC Frequency Hz 50/60 50/60 50/60 50/60 Power consumption kw 0.4 0.4 0.8 0.8 Current consumption A 1.7 1.7 3.4 3.4 Protection class l / IP 20 l / IP 20 l / IP 20 l / IP 20 Protective measure Protective conductor connection Individual precautions on customer side Lead fuse (slow blow) T 16 A or circuit breaker B 16. The electrical regulations in the country of use as well as the relevant connection conditions must be observed. Supply management Same as HERAsafe KS 1) Equipment and support frame are delivered individually. Installation and assembly on-site, 2) Further voltages on request 7

Thermo Scientific Microbiological Safety Cabinets HERAsafe KS Technical Specifications HERAsafe KS Type Unit KS 9 KS 12 KS 15 KS 18 Dimensions External dimensions KS 1) (w/h/d) mm 1000/1586/800 1300/1586/800 1600/1586/800 1900/1586/800 Internal dimensions (w/h/d) mm 900/780/627 1200/780/627 1500/780/627 1800/780/627 Minimum doorway (d) mm 800 800 800 800 Work aperture (h) mm 250 250 250 250 Max. lifting height of front window (not open) mm ~470 ~470 ~470 ~470 Working height (optional support frame) mm 780 + 20 mm adjustable floor stand between 750-950 mm Weight Equipment kg ~190 ~240 ~290 ~340 Maximum load capacity of work surfaces for single module work surface kg 50 50 50 50 for segmented work surface kg 25 25 25 25 Ventilation system 2) Exhaust air/inflow volume flow m 3 /h ~380 ~500 ~625 ~750 Air circulation volume flow m 3 /h ~670 ~890 ~1100 ~1330 Heat emission at 25 C room temperature kw ~0.2 ~0.2 ~0.4 ~0.4 Filter technology Supply/exhaust air filter type HEPA H 14 EN 1822, 99.999% at 0.3 µm particle size Additional Exhaust Filter (AEF) type HEPA H 14 EN 1822, 99.999% at 0.3 µm particle size Performance Lighting power lx > 1000 > 1000 > 1000 > 1000 Electrical data Voltage 2) V 1/N/PE 230 V AC 1/N/PE 230 V AC 1/N/PE 230 V AC 1/N/PE 230 V AC Frequency Hz 50/60 50/60 50/60 50/60 Power consumption kw 0.4 0.4 0.8 0.8 Current consumption A 1.7 1.7 3.4 3.4 Protection class l / IP 20 l / IP 20 l / IP 20 l / IP 20 Protective measure conductor connection Individual precautions on customer side Lead fuse (slow blow) T 16 A or circuit breaker B 16. The electrical regulations in the country of use as well as the relevant connection conditions must be observed. Supply management Supply requirement 230 V/50 Hz standard supply. Total requirement including interior sockets 13 16 Amps. The national regulations for electrical engineering as well as the relevant technical connection conditions must be taken into account. Receptables The sockets have a load capacity of up to 5 A and are protected with T 5 A fuses. When all sockets are in use simultaneously they must not exceed the maximum total load capacity of 5 A. Radio interference Circuit is interference free in accordance with EN 55 014 2007 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. North America: USA/Canada +1 866 984 3766 www.thermo.com/bsc Europe: Austria +43 1 801 40 0, Belgium +32 2 482 30 30, Finland +358 9 329 100, France +33 2 2803 2000, Germany national toll free 08001-536 376, Germany international +49 6184 90 6940, Italy +39 02 95059 1, Netherlands +31 76 571 4440, Russia/CIS +7 095 225 11 15, Spain/Portugal +34 93 223 09 18, Switzerland +41 44 454 12 12, UK/Ireland +44 870 609 9203 Asia: China +86 21 6865 4588 or +86 10 5850 3588, India +91 22 5542 9494, Japan +81 45 453 9220, Other Asian countries +852 2885 4613 Countries not listed: +49 6184 90 6940 or +33 2 2803 2000 BRO-CECA-HSAFE-0307