SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Similar documents
SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700S

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

Xenon 700 Open-Path Gas Detection System. User's and Maintenance Manual TM , Rev. A, September 2003

Xenon 700S. User Guide

Dräger Flame 2500 (IR3) Flame Detection

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger Flame 2700 (Multi-IR) Flame Detection

The SharpEye 40/40I (IR3) Flame Detection

Dräger Flame 2100 Flame Detection

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Flame 2100 (UV) Flame Detection

Dräger Flame 2500 Flame Detection

The SharpEye 40/40M (Multi IR) Flame Detection

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Flame 2370 (UV&IR) Flame Detection

Global Gas Detection and Monitoring Solutions

Quasar 900. User's and Maintenance Manual

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

The SharpEye 40/40I (IR3) Flame Detection

The SharpEye 40/40R (IR) Flame Detection

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

OLC(T) 100 FIXED GAS DETECTOR

MSA Flame and Gas Detection. [ for the Oil, Gas and Petrochemical Industries ]

SIMRAD GD10L - IR GAS DETECTOR OPERATING MANUAL

HigH Performance Low cost flame Detection. Courtesy of Foster + Partners. The New 20/20M MINI FLAME DETECTOR SERIES

incontrol Systems Inc. Flame and Gas Detection

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

Dräger PIR 3000 Detection of flammable gases and vapours

Eliminating False Alarms in Toxic Gas Detection. Jason Schexnayder Sales Manager - Americas

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Flame Detection Jon Sarfas

Searchpoint Optima Plus

SafEye TM Series 200 Open-Path Gas Detection System

GAS DETECTORS. When every second counts

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

U L T R A S O N I C G A S L E A K D E T E C T O R

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Dräger PIR 7200 Toxic Gas Detection Transmitter

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Dräger PIR 7000 Flammable Gas Detection

Dräger REGARD -1 Control System

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Lamp Supply (Recommended)

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

XNX Universal Transmitter

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Dräger Polytron 7000 Fixed gas detector

3M Oldham OLCT 100. Description. Fixed Gas Detector

GAS PLUS ALARM SYSTEM

Transmitters/Sensors. OLCT Series

Searchpoint Optima Plus

Dräger Flame 5000 Flame Detection

Industrial Grade Gas Detection

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

Dräger PIR 7200 Detection of toxic gases and oxygen

ADPRO PRO Series by Xtralis

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

SIMRAD GD10 IR GAS DETECTOR

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron 8310 IR Detection of flammable gases and vapour

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

Dräger GS01 (wireless) Detection of flammable gases and vapours

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

Case Study. Selecting fire and gas detectors for harsh and remote locations. INSTRUMENTATION

FUNCTIONAL SAFETY MANUAL

Detection, Protection, Innovation

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Autronica Fire and Security AS ID:

IR25 Dual Gas Series Datasheet

Selecting fire and gas detectors for extreme environments:

OMA-300 Process Analyzer

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

MSA Fixed Gas & Flame Detection for the Automotive Industry

Sieger Apex. Flexibility that meets your requirements

Dräger Polytron 8720 IR Detection of carbon dioxide

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Mini Triple IR (IR3) Flame Detector. User and Maintenance Manual

Dräger Polytron 8100 EC Detection of toxic gases and vapors

SEC Signature Process Gas Analyzer

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

Transcription:

Open-Path Gas Detection System SAFEYE XENON 700 Hydrocarbons and ethylene detection Heated optics 10-year Warranty for the Xenon flash bulb SIL 2 according to IEC 61508 Certifications The Fixed Gas Detection People www.oldhamgas.com an company

SAFEYE XENON 700 Open Path has been designed to detect hydrocarbons in industrial applications. They are used most often in addition to point type gas detectors to monitor a wider area. The SafEye Xenon 700 consists of an advanced Xenon Flash infrared transmitter (source) and infrared detector (receiver), separated over a line of sight from 13 ft (4 m) up to 460 ft (140 m) to detect and quantity flammable gas presence, even when challenged by extremely harsh environments where dust, fog, rain, snow, or vibration can cause a high reduction of signal. The open path analyzes atmospheric absorption at three selected spectral bands, two in a region where the target gas absorbs and one where it does not absorb. The ratio between these absorption lines can provide accurate information of the gas concentration along an optical path. When no gas is present, the two signals are equal whereas if gas is present, measurement and reference signals are different. These three detectors contribute to the reduction of false diagnostics and assure high immunity to false alarms. Moreover, thanks to infrared technology, the SafEye Xenon 700 can maintain operational integrity up to 90% obscuration and accepts up to 1 misalignment tolerance. The SafEye Xenon 700 includes heated optics on the transmitter and receiver to address icing, condensation and snow. The SafEye Xenon 700 is an ideal Open-path whatever your application. SafEye Xenon 700 Receiver Source Fast response time: 3 seconds

Safeye FEATURES Specifications System Open path SafEye Xenon 700 Model 701 702 703 721 722 723 Distance (m) 4-20 15-70 50-140 4-20 15-70 50-140 Distance (ft) 13-66 50-230 165-430 13-66 50-230 165-430 Detected gas C1-C8 Ethylene / LPG Immunity to false alarm Not influenced by solar radiation, hydrocarbon flames and other external IR radiation sources Spectral response 2.0-4.0 µm Sensitivity range 0-5 LEL.m (optional 0-2 LEL.m) Displacement tolerance +/- 1 Drift Long term +/- 5% of full scale Temperature range -40 C to +55 C (-40 F to 131 F) Electrical specifications Power supply 18-32 VDC (24 VDC nominal) Power consumption (peak includes heated optics) Electrical connection Outputs - Detector : 150 ma (300 ma peak) - Source : 100 ma (300 ma peak) 2* ¾ NPT or 2* M25 4-20 ma current output - Maximum load: 600 Ohm (18-32 VAC) - 4-20 ma: normal mode, gas reading - 0 ma: fault - 1 ma: zero calibration mode - 2 ma: obscuration/misalignment/beam block - 3 ma: maintenance call RS485 Interface - Modbus To connect PC or handheld communicator kit compatible Alarm, Fault and Accessory Relays SPST volt-free contacts rated 5A at 30 VDC or 250 VAC Fault relay normally closed, others normally open Mechanical specification Weight - Detector: 4.2 kg (9.2 Lb) - Source: 4.6 kg (10.1 Lb) - Tilt mount: 1.9 kg (4.2 Lb) Ingress Protection - IP 66 and 67 - NEMA 250 6P Dimensions - Detector: 210 x 145 x 154 mm (8.2 x 5.7 x 6 inch) - Source: 255 x 135 x 175 mm (10 x 5.3 x 6.9 inch) - Tilt mount: 120 x 120 x 140 mm (4.7 x 4.7 x 5.5 inch) Enclosure The detector, the source and the tilt mount are in stainless steel 316L Approvals - Electromagnetic compatibility - ATEX Ex II 2(1) GD, EEx de ia [ia] IIC T5 (+55 C) - SIL 2 certified by TUV according to IEC 61508 Environment Meets MIL-STD-810C for humidity, salt, fog, vibration, mechanical shock, high temperature, low temperature Warranty - System: 3 years - Lamp: 10 years Accessories Handheld communicator kit The handheld communicator kit is an intrinsically safe diagnostic/calibration/interrogation tool with quick plug connection, which provides easy and economical SafEye maintenance. The handheld unit will provide verification, gas concentration, status and instructions for correcting the detector s parameters and can assist one-person installation and maintenance and recommend corrective actions including cleaning the window, aligning the detector/source. Alignment telescope

Examples Example 1 Source 20 meters 5% LEL Receiver Example 2 Source 1 meter 100% LEL Receiver Not all gas clouds are hazardous. Only if a flammable gas cloud or plume is wide enough to allow flame acceleration to speeds greater than 100 m/sec, does it become a significant threat. Contrary to point type gas detectors, the open path measures the gas cloud concentration over many meters. Thus, the unit of measurement for Open Path is LEL.meter instead of % LEL. In the example, a cloud of 100% LEL concentration on 1 meter will give the same signal than a cloud of 5% LEL on 20 meters. 100% LEL x 1 meter = 5% LEL x 20 meters = 1 LEL.meter Location of the SafEye 700 is less important than with point type detector as it provides a warning alarm from a diluted gas cloud and does not need to be close to the leakage source. Fewer Open Paths are needed to secure the site, reducing installation costs. Advantages Detection of a wide range of gaseous hydrocarbons such as Alkanes, Alkenes, Alcohols, LNG, LPG, Ethylene SIL 2 approved by TÜV according to IEC 61508 Ex Approved for hazardous area location Fast response time Heated optics for operation in harsh weather conditions Multiple output options : ma, relays, RS 485 ModBus, HART Solar blind and immune to false alarms from industrial environments Resilient and excellent performance withstanding extreme vibrations, displacement and shock Dirty optics compensation Rugged, stainless steel structure 10-year warranty for Xenon flash bulb One-person commissioning and installation

Open path gas detection System Applications The new SafEye version is based on proven technology and performance. Thousands of first generation SafEyes have been installed on offshore platforms, refineries and other onshore applications. Offshore platforms SafEye Xenon 700 provides alarm and shutdown signals that enable emergency and preventive measures. Oil and Gas Many process and storage areas in the modern refinery are protected by the SafEye systems. Process plants and pipelines Hydrocarbons, LNG/LPG or Ethylen detection in LEL.m. Other applications - Onshore industry - Pipeline - Paint-booths - Bus terminals (natural gas powered) - Storage areas - Waste disposal and processing SafEye Xenon 700 combines performance, strength and reliability. www.oldhamgas.com

Our fixed detector range OLCT 10 OLCT 10N CTX 300 OLCT 100 itrans OLCT 80 OLCT 60 OLCT 60 / OLCT IR OLCT IR SafEye Sharpeye OUR MISSION Preserving human life, above and below the earth. Delivering highest quality, best customer service Every transaction, every time Test and calibration gas www.oldhamgas.com AMERICAS Tel.: +1-713-559-9280 Fax: +1-281-292-2860 americas@oldhamgas.com EUROPE Tel.: +33-3-21-60-80-80 Fax: +33-3-21-60-80-00 info@oldhamgas.com For your safety, test and calibrate your gas monitors regularly. ASIA PACIFIC Tel.: +86 21 5899 3279 Fax: +86 21 5899 3280 info@oldhamgas.com SafEye700_lit_ENG_17Oct2013