Using the QRAE Plus personal multigas monitor

Similar documents
RAE Systems Systems. User Presentation. October Protection Through Detection

Using the MiniRAE 2000 & ppbrae PID

Operate the Mutli-Gas Monitor PID

ALTAIR 5X Multigas Detector Product Specification

GasAlertMicroClip X3 Specifications

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

1, 2, 3, and 4-Gas Detector. Technical Reference Guide

GasAlertMicro 5 and GasAlertMicro 5 PID O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, and Combustibles

For the Safety of Your

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

IMR IX176 Portable Gas Detector User Manual

AreaRAE PGM-5020 WIRELESS MULTI-GAS MONITOR. Operation & Maintenance Manual Document Number: Revision B, April 2003

Safe Operation Manual. Honeywell IQ Force Gas Detector

Technical Reference Guide. 1, 2, 3, and 4-Gas Detector

Dräger X-am approved as type MQG 0010 Multi-Gas Monitor Technical Manual _01.eps

NH 3 RESPONDER Portable Ammonia Leak Detector QUICK REFERENCE GUIDE

QUICK REFERENCE GUIDE

Sirius MultiGas Detector

Instruction Manual Eagle Series

Operator s Manual. 1, 2, 3, and 4-Gas Detector

NH3 RESPONDER PORTABLE AMMONIA LEAK DETECTOR. Quick Reference Guide

User Manual. Single Gas Detector

UltraRAE 3000 Basic Operation Pocket Reference

Operator s Manual. 1, 2, 3, and 4-Gas Detector

MultiRAE Plus. PGM-50/4, PGM-50/4P, PGM-50/5P Multiple-Gas Monitor

Single Gas Detector. Quick Reference Guide

RAE Systems. Using the MeshGuard. Protection Through Detection

Reference Manual. MultiVision Gas Detector

Bacharach Bodyguard 4 User's Guide

Personal Single Gas Monitor. Activation Operation Troubleshooting

Portable type of Carbon Dioxide Detector Model: GT220

X5 Personal Gas Detector. Operating Manual

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide

Operating Instructions and Maintenance Manual

1, 2, 3, and 4-Gas Detector. Technical Reference Guide

MiniRAE 3000 ppbrae Basic Operation Pocket Reference

Dräger X-am approved as type MQG 01** Multi-Gas Monitor. Technical Handbook. CO2 Vol% CH4 %UEG. CO ppm. ppm NH _01.

Reference Manual. MultiPro Gas Detector

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

Wireless Personal Four-Gas Monitors

Reference Manual MultiPro Gas Detector

E1000 Portable gas detector

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

INSTRUCTION MANUAL MODEL GX-82A

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

MeshGuard TM Monitor User s Guide

ToxiPro. Single Gas Detector. Reference Manual

Monitores Personales. Personal Monitor

IMR EX610. Portable Gas Detector. Operation Manual

INNOVA Series INSTRUCTION MANUAL P/N REV. D

Activation Operation Troubleshooting Part Number: Edition: Release Date:

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

G460. Multi-gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

Model:AS8900 MULTI-GAS MONITOR O 2 %VOL H 2S PPM LEL%VOL CO PPM. Version number:as

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

GasAlertMicro 5 / PID / IR

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

RAE Systems RAE Systems RAE Systems Presented by David Lucha RAE Systems Protectio n Through Detection

GX-2009 Portable Gas Monitor Operator s Manual

Reference Manual PhD5 Multi Gas Detector

1.1 Definitions of alert icons. For your safety

Multi-gas Monitor. Product Manual Set-up Operation Service. Part Number: Version 12

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Toxi Vision IR CH 4. Single Gas Detector. Reference Manual

MULTI-GAS MONITOR. Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand

G450. Multi-gas Detector. Field Operation Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

QRAE II User s Guide. Covers QRAE II Diffusion & Pump Models with Firmware Version 3.60 or higher

ALTAIR 5X Multigas Detector

SIRIUS. [ MultiGas Detector ] Instruction Manual. Manufactured by: MSA INSTRUMENT DIVISION P.O.Box 427, Pittsburgh, Pennsylvania 15230

SENSIT HXG-2d Combustible Gas Detector

Issue 4 10/10/11. Part Number: 48160

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

INSTRUCTION MANUAL MODEL GX-82A

Pioneer-R16 Gas Monitor Operator s Manual

Dräger X-am 2500 (MQG 0011) Technical Manual

QRAE II User s Guide. Covers QRAE II Diffusion & Pump Models with Firmware Version 3.12 or higher

G450. Multi-gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

GX-2009 Portable Gas Monitor Operator s Manual

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

INNOVA Series. Instruction Manual Part Number

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

multi-gas detector Go the distance, and save Wear yellow. Work safe.

SC-01 Operator s Manual

ToxiRAE 3 User s Guide

S ing le G a s D etec tor. R eferenc e M a nua l

MDU 420. Instruction Manual. Dual Range Methane Monitor. P/N REV 0 Printed Specifications Subject to Change

TMX 412. Instruction Manual. Multi-Gas Monitor. P/N REV 11 Printed Specifications Subject to Change

ALTAIR 5X Multigas Detector

GX-2009 Portable Gas Monitor Operator s Manual

Operating Manual (PT0-119)

Transcription:

Using the QRAE Plus personal multigas monitor Firmware v 1.10 QRAE Plus The Hazardous Environment Detection Company

QRAE Plus features Turning on the QRAE Plus Recommended Daily Start-up Procedure User modes & displays Alarm modes Programming displays Calibration Training Agenda:

QRAE Plus Features: Sensors The Q in QRAE Plus stands for quad, as in it can carry four Oxygen: 0-30% sensors at a time: Combustibles: 0-100% of LEL Select two toxic sensors from: CO, H 2 S, SO 2, NO, NO 2, Cl 2, HCN, NH 3, PH 3

Sample Port Sensor Compartment QRAE Plus Features: Sensors Q-RAE+ Gas Features: Sensors Plate Separate sensor compartment allows quick sensor access and reduces the chance of damage to the computer boards through leaking sensors or user damage while replacing sensors.

QRAE Plus Features: Reliability Extremely rugged for extensive field use Weather Proof Case Temperature range of -4 o F to 113 o F (-20 o C to 45 o C) RFI protection against radio interference UL Intrinsic safety for flammable gases, vapors & DUSTS UL Vapor: Class I, Division 1, Groups A, B, C, D UL Dust: Class II, Division 1, Groups E, F, G CSA: ATEX:

QRAE Plus Features: Rugged Case Alarm Buzzer Gas Exit Port Display Li-ion Battery The Hazardous Environment Detection Company

Li-ion Battery QRAE Plus Features: Li-ion Battery Up to 20 hours on Lithium-ion Batteries 4-Way power: Lithium-ion, Alkaline or run continuously on 110 VAC and 12 VDC Battery is quick and easy to detach for quick field change to alkalines Unscrew battery using a coin Data Port Charge Port Sample Port

QRAE Plus Features: Simple Faceplate Light Sensor Alarm LEDs Front View Side View Just 3 buttons control all functions: Y/+ (horn): clears & tests alarms N/- (light): turns on manual backlight for 5 seconds MODE (on)

QRAE Plus Features: Internal Pump Optional internal pump makes remote sampling easy Sample draw over 100 feet! Liquid water trap for added protection Pump stall feature: when moisture is detected or when pump is blocked the pump will shut off, protecting the QRAE Plus from potential damage ~150cc/min at Low flow, ~250cc/min at High flow

QRAE Plus Features: External Prefilter Always use the prefilter Replace when it looks very dirty Replace when QRAE Plus is in pump alarm with the filter on and you can clear the pump alarm with the filter off. You wouldn t leave your house without putting on your pants so don t use the QRAE Plus without its external filter!

QRAE Plus Features: Alarms Audible: LOUDER 95dB buzzer (special resonance chamber increases the sound) Tactile: internal vibrator Visual: Display backlight turns on along with bright LEDs on faceplate External: Audible and vibration alarms via dataport

QRAE Plus Start-up: Turning On Unplug QRAE Plus from charger Hold MODE Key to turn on Alarm will beep once Watch display screen for messages such as: Sensors installed & their warranty expiration Alarm limits Last calibration date User/Alarm/Datalog modes Warm-up will take approximately 90 seconds

QRAE Plus Start-up: Warning Messages Sensor 1: CO Warranty expired This is a warning screen. As long as the sensor calibrates properly it is valid to continue using it. Acknowledge by pressing the Y key to continue warm-up. For maximum QRAE Plus availability, RAE Systems recommends replacing sensors at the end of their warranty period.

QRAE Plus Start-up: Check Sensor Zero 0 0 0 OK 20.9 After 90 sec. warm-up, the QRAE Plus will display for all of the installed sensors If there is no alarm, and the sensor readings are in the range shown above, then the QRAE Plus is ready for use. A Fresh Air Calibration may be required if the sensors do not read correctly.

QRAE Plus Start-up: Check Pump 0 0 0 Pump 20.9 Every time the QRAE Plus is used it is important to check pump flow Block the filter on the pump inlet Reset pump alarm by pressing the Y key If pump does not go into alarm, check for loose/cracked filter or service pump

QRAE Plus: Two Display Modes Basic Operation Mode: a reduced set of user and programming screens designed for most users. Advanced Operation Mode: provides more user screens and full access to all programming screens.

Advanced (11) Basic (7) Sensor ID Sensor ID PEAK PEAK MIN MIN STEL STEL TWA TWA Battery Battery Time/Date/Temp PC Comm Start Datalog* LEL Gas Print Reading* PC Comm Comparison of Display Modes

0/CO 0/LEL QRAE Plus: Main Display 0/H 2 S 20.9/OXY QRAE Plus will return to this screen in 60 seconds if left in any subsequent screen This screen alternates between the instantaneous reading and the sensor name approximately every 3 seconds Tap MODE key to proceed

34 11 Peak Reading Display 6 PEAK 20.9 Holds Highest reading since QRAE Plus was turned on Pressing Y key will produce Reset Peak? prompt. Pressing again will clear Peaks. Tap MODE key to proceed to next screen

Minimum Reading Display 0 0 0 MIN 16.3 Holds Lowest reading since QRAE Plus was turned on Pressing Y key will produce Reset Min? prompt. Pressing again will clear Minimum readings. Tap MODE key to proceed to next screen

0 0 STEL STEL Display Short Term Exposure Limit (average for the past 15 minutes) Displays **** until QRAE Plus has been on for 15 minutes STEL only is calculated for toxic sensors STEL alarm beeps once a second Tap MODE key to proceed

0 0 TWA TWA Display Time Weighted Average is the accumulated reading of gas concentration divided by 8 hours since the QRAE Plus was turned on. TWA only is calculated for toxic sensors TWA alarm beeps once per second Tap MODE key to proceed to next screen

Battery = 3.8V Shut off at 3.1V Battery Voltage Display QRAE Plus shuts down when battery voltage drops below 3.1 volts Normal Full Charge is about 4.2 volts Tap MODE key to proceed to next screen

Date Time of day Date/Time/Run Time/Temp. Display This screen is deleted in Basic Mode 07/01/98 12:00 ON=01:22 Accumulated time in hours and minutes since the QRAE Plus was turned on Temperature in Centigrade or Fahrenheit (user selectable) Tap MODE key to proceed 25 o C/ o F

Datalog Mode Display This screen is deleted in Basic Mode Start Datalog? Manual: logs if Y/+ key is pushed Automatic: logs data when as soon as the QRAE Plus is turned on User can choose one of 4 datalog modes (Manual, Automatic, Periodic & Scheduled in ProRAE Suite) Screen deleted on non-dataloggers

0 0 0 L Datalog Mode Display 20.9 A small L is displayed in the left center of the main QRAE Plus screen indicates datalogging Will datalog 16,000 points 66 hours at 1 minute interval for all 4 sensors User can choose one of 4 datalog modes (Manual, Automatic, Periodic & Scheduled in ProRAE Suite)

This screen is deleted in Basic Mode LEL gas= Methane LEL Units Display Measurement scale for LEL displayed here Measurement scale can be changed in programming mode Tap MODE key to proceed to next screen

Print Reading Display This screen is deleted in Basic Mode Print Reading? If the optional external printer is attached pressing the Y/+ key will print out the current reading. If the optional printer is not installed it will display wait for 20 seconds and then return to the Print Reading? screen. This screen appears only if the option is enabled in ProRAE Suite

Communicate with PC Display Communicate with PC? If Y/+ key is pushed then QRAE Plus will display Monitor will Pause. OK? If Y/+ key is pushed again the QRAE Plus will display Ready... until it receives a signal from the computer or the MODE key is pressed. Tap MODE key to proceed

Ready... Communicate with PC Display When the QRAE Plus is in this communication standby mode it stops monitoring gas concentrations and stops datalogging. Datalogging must be manually restarted when exiting unless automatic datalogging is in use.

QRAE Plus Alarm Signals The QRAE Plus will provide audible, tactile and visual alarms to alert users to unsafe states It is extremely important to note that during the following conditions the alarm signals are disabled: When entering the Communicate with PC? standby mode. When entering the Calibrate Monitor? menu When viewing data in the Change Datalog? menu

QRAE Plus Alarms: High High 0 0 20.9 High display along with a 3 beat/second audible/tactile/visual alarm indicates that CO sensor has exceeded high alarm set point (greater than 200 ppm CO default). Press Y/+ key to clear if latching alarm

QRAE Plus Alarms: Low 0 0 0 Low Low display along with a 2 beat/second audible/tactile/visual alarm indicates that Oxygen sensor has gone into low alarm (less than 19.5% Oxygen default) Press Y/+ key to clear if latching alarm

QRAE Plus Alarms: STEL STEL 0 0 20.9 STEL display along with a 1 beat/second audible/tactile/visual alarm indicates that CO sensor has exceeded STEL alarm set point (100 ppm CO default). This alarm will only clear after 15 minutes in clean air or QRAE Plus is turned off!

QRAE Plus Alarms: TWA TWA 0 0 20.9 TWA display along with a 1 beat/second audible/tactile/visual alarm indicates that CO sensor has exceeded TWA alarm set point (35 ppm CO default). This alarm will only clear after moving to clean air and then turning off the QRAE Plus

QRAE Plus Alarms: LEL OFF 0 0 OFF 20.9 OFF display along with a 3 beat/second audible/tactile/visual alarm indicates that LEL sensor has been exposed to too much gas and has shut off to protect the sensor. Move the meter to clean air and press the Y key to reset.

QRAE Plus Alarms: LEL OFF 0 0 OFF 20.9 If the QRAE Plus is used in high concentrations of flammable gas consider either the VOL or AUTO setting in Change LEL/VOL Sensor Type? in the Change Sensor Configuration menu.

QRAE Plus Alarms: NEG NEG 0 0 20.9 NEG display along with a 1 beat/second audible/tactile/visual alarm indicates that CO sensor has drifted negative (below zero) because the sensor was zeroed in an area containing CO. Perform Fresh Air Calibration in an area clear of all CO.

QRAE Plus Alarms: Pump 0 0 0 Pump 20.9 Pump display along with a 3 beat/second audible/tactile/visual alarm indicates that pump has stopped due to line clog Pump alarm is a latching alarm Clear line/filter and press Y/+ key to reset alarm and restart pump

QRAE Plus Alarms: Low Battery 0 0 0 Bat 20.9 A flashing Bat display along with a 1 beat/second audible/tactile/visual alarm indicates every minute indicates that the battery voltage has dropped below 3.1V and it will shut down in 20-30 minutes Quickly complete confined space entry and charge the QRAE Plus

QRAE Plus Alarms: Memory Full 0 0 0 MEM 20.9 A flashing MEM display along with a 1 beat/second audible/tactile/visual alarm indicates that the datalog memory is full. Clear datalog in Change Datalog? If you get this alarm you might want to consider changing Select memory full type? to Wrap around.

Getting Into Programming Hold MODE and N/- keys for 5 sec. to get in Programming Mode If QRAE Plus asks a question? Answer Y or N To Accept or Escape Use MODE Key repeatedly pushing the MODE key will always eventually return user to main display

Setting Security Levels ProRAE Suite allows users to configure security levels. Coupled with the Basic and Advanced modes, user can limit operator access to the higher functions of the QRAE Plus to meet the specific needs of their application. Appendix A-1 of the QRAE Plus manual provides an excellent summary of how to configure operating modes and security levels for optimum performance.

Level 0: Setting Security Levels Basic Mode: prevents operator access to all programming functions Advanced Mode: limits operators access to the Basic programming functions Level 1: operator access is password controlled but all mode programming functions available

Setting Security Levels Level 2: operator has complete access to all programming functions available in the operating mode

Calibrate Monitor? Fresh Air Calibration? Multiple Sensor Calibration? Single Sensor Calibration? Change Monitor Setup? Change User Mode? Set Clock? Basic Programming Menus Choose (Y) to accept or (N) to move on ref. Appendix A-1 & A-2 in QRAE Plus Manual

Advanced Programming Menus Calibrate Monitor? Change Alarm Limits? Change Datalog? Change Monitor Setup? Change Sensor Configuration? Choose (Y) to accept or (N) to move on ref. Appendix A-2 in QRAE Plus Manual

Fresh Air Calibration? Make sure air is clean! Multiple Sensor Calibration? Single Sensor Calibration? Modify Span Gas Value? Change LEL Span Gas? OXY Calibration Type? Calibrate Monitor? Choose (Y) to accept or (N) to move on, MODE to escape

CO Multiple Sensor Calibration H 2 S LEL OK? --- At Multiple Sensor Calibration press Y/+ key For CO/H2S/LEL mixed gas calibration the next screen should appear as above

Multiple Sensor Calibration Attach calibration gas regulator to mixed gas cylinder Turn on calibration gas Attach calibration adapter to QRAE Plus press Y/+ key and the QRAE Plus calibration procedure will start Follow instructions on screen Disconnect regulator when completed

Calibration Modify Span Value Allows you to change the calibration gas values to use other cal gases Do not change if you are using the RAE Systems cal gas supplied with your meter Change LEL/VOC Span Gas? Allows you to change the calibration gas from methane (LEL) & isobutylene (VOC) Do not change if you are using the RAE Systems cal gas supplied

OXY Calibration Type? 2 Point Calibration: provides for calibration at 20.9% (Fresh Air) and 0% oxygen 3 Point Calibration: provides for calibration at 20.9%, mid-range (like 16-19.5% Oxygen) and 0% oxygen. Many mixed gas cylinders have 16-19.5% oxygen for greater oxygen sensor accuracy at the critical 19.5% alarm point.

Change High alarm limit? 3 Beeps per second ( High ) Change Low alarm limit? 2 Beeps per second ( Low ) Change STEL alarm limit? 1 Beep per second ( STEL ) Change TWA alarm limit? 1 Beep per second ( TWA ) Change Alarm Limits? Choose (Y) to accept or (N) to move on, MODE to escape

Clear All Data? Change Datalog Period? Select Data Type? Enable/Disable Datalog? Select Memory Full Type? Change Datalog? Choose (Y) to accept or (N) to move on, MODE to escape

Select Memory Full Type? Wrap around (default): after the memory becomes full the newest data is written over the oldest data (First in First Out or FIFO). This is an excellent feature to provide background datalogging that is only used in case of an incident. Stop: datalogging will stop when the memory is full and the MEM alarm will sound.

Change Site ID? Change User ID? Change Alarm Mode? Change Monitor Setup? Change User Mode? (Advanced or Basic) Change Real Time Clock? Choose (Y) to accept or (N) to move on, MODE to escape

Change Monitor Setup? Change Back Light Mode? Change Password? Change Pump Speed? Change Averaging Method? Change Display Language? (English, Spanish) Set Temperature Unit? (oc or of) Enable/Disable Vibrator? Choose (Y) to accept or (N) to move on, MODE to escape

Change Sensor Configuration? Change LEL/VOL Sensor Type? (LEL, %VOL, Auto for CH4 only) Enable/Disable Sensor? Change LEL Gas Selection? Choose (Y) to accept or (N) to move on, MODE to escape

QRAE Plus: Power Off Hold Mode Key for full 5 seconds Audible alarm will beep and display will read Power-down in...5,4,3,2,1 seconds Leave QRAE Plus on charger when not in use

Charging... QRAE Plus: Charging Plug 12 VDC charger into charge port QRAE Plus will take 6-8 hours to fully charge The Lithium-Ion battery in the QRAE Plus does not require deep discharge!

Fully Charged. QRAE Plus: Charging You can leave QRAE Plus on charger when not in use The QRAE Plus will automatically detect the alkaline battery adapter and prevent charging if it is attached instead of the Li-ion

Using ProRAE Suite Configuration from Computer Datalogging The Hazardous Environment Detection Company

Questions? The Hazardous Environment Detection Company