For assistance with the product please contact: HELPLINE. For a product brochure please contact:

Similar documents
For assistance with the product please contact: HELPLINE. For a product brochure please contact:

360º Surface Mount Ceiling PIR Light Controller

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

360 Surface Mount Ceiling PIR Light Controller

Surface Mount Wall PIR Light Controller. Model: PDWM1500. Installation & Operating Instructions

Model: PDSM1500. Installation & Operating Instructions 360º Surface Mount Ceiling PIR Light Controller

Model: MLSA360N. Installation & Operating Instructions. 360º Night Eye PIR Light Controller

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS

60W Multi PIR Bulkhead

Model: PDFM1500. Installation & Operating Instructions 360º Flush Mount Ceiling PIR Light Controller

360 Ceiling PIR Light Controller

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

5W LED Energy Saver PIR Bulkhead

18W Round LED Wall/Ceiling Light with Microwave Sensor

12W Round LED Wall/Ceiling Light with Microwave Sensor

BATTERY POWERED DETECTOR/ TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTXDCB INSTRUCTIONS

"Options" Sensor Module

30W LED PIR FLOODLIGHT. Model: LEDX30PIRB Model: LEDX30PIRWH

Security Light Transmitter

60W Security Spotlight. 754HB1/180/ Outdoor Motion Sensor. Installation Instructions. Please leave these instructions at the installation site.

High Frequency Sensor

Programmable Security Light Switch

CHIME RECEIVER INSTALLATION & OPERATING. Cat No. TLRXC1 INSTRUCTIONS

Emergency Assist Alarm Kit Single Zone

Installation & Operating Instructions

Lantern Receiver E-997 INSTALLER GUIDE. SF-LA-BC-RX-W.qxd 13/04/ :36 Page 1

Digital Room Thermostat with Night Set-back

Compact Movement Activated Sensor Installation Instructions

Battery Powered Electronic Programmable Room Thermostat

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

Battery Powered Electronic Room Thermostat Cat. No. TRT033

Cylinder/Pipe Thermostat Cat. No. TRT044. Operating & Installation Instructions

Illuminating. Solutions. for Energy Saving. Featuring the latest PIR Lighting solutions from Timeguard.

DOOR & WINDOW ALARM INSTALLATION & OPERATING. Cat No. TG232W INSTRUCTIONS

TIMEGUARD WEATHERSAFE OUTDOOR POWER RANGE INSTALLATION & OPERATING INSTRUCTIONS

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

Professional, Rewireable, Linkable LED Lighting

PRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring.

Electronic Frost Thermostat

Electronic Room Thermostat Cat. No. TRT030

Cat. No TPT44. Installation & Operating Instructions

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

LED Lighting. Solutions

Ceiling PIR HS presence detector. Product Guide. Overview. Features

PMCSF6 OCCUPANCY SENSOR

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site.

LED Lighting. Solutions

LED Lighting Solutions

LPCMPIRM65 & LPCMPIRDSI65

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

USER GUIDE MOTORISED LED FLOOD LIGHT CAN WE HELP?

. w. POWERHOUSE n MOTION DETECTOR MODEL PR511 OWNER S MANUAL

Safety! Seasonal INSIDE THIS ISSUE. Small and Powerful LED lighting Energy Saving without compromise.

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Motion Sensor. Specifications

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

1. Basic safety information 3 2. Proper use 3

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

Motion tracking. sensor led light. Installation & operating manual NIGHTWATCHER. Model no: nw1200x

Super. Bright. Lumens! Super. Slim!

1. Basic safety information 3 2. Proper use 3

, ,

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

Installation and Safety Instructions Cone Wall Light with PIR Stainless Steel Model: S083S

Integrated PIR detectors

Chime Receiver E-996 INSTALLER GUIDE. SF-DCC-RX.qxd 13/04/ :30 Page 1

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

LED Sensor Floodlight AZPOSE XL-S

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

INDOOR INFRASCAN. Passive Infrared Motion Sensors 751 SERIES INSTALLATION MANUAL. Please leave these instructions at the installation site

Lighten. the Load! MASTERS. SUPPLY! Timeguard s range of Fused Spur Timeswitches. Savings! LIGHTING. Countdown. On Demand! ALSO INSIDE THIS ISSUE

IP 55 (category II) IP 54 (category II) 4. Connection. 1. Basic safety information. 2. Proper use. 5. Installation. 3. Description.

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

LPC3BSP65 & LPC3BDP65

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

SENSA MRE DDM MR

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Simple Instructions for the WisePIR

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

System 2000 System 2000 automatic control switch Safety instructions. 2 Device components

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

60 WATT SQUARE WALL LAMP WITH P.I.R. MOVEMENT SENSOR INSTRUCTIONS

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

FR-A180 FR-A360. Occupancy detector. Use

LUX Hardwired - Installation Notes

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

Transcription:

For assistance with the product please contact: HELPLINE 020 8450 0515 or email helpline@timeguard.com For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.com 67.058.497 (Issue 3) Zerofour June 2014

Masking the Sensor Lens To reduce the sensor coverage, preventing detection in unwanted areas, mask the sensor lens using the lens mask sticker supplied (see diagram D). For your information, the centre section of the lens covers short range detection, and the outer edge of the lens covers long range. Mask the sensor to suit your installation. 7 Setting Up for Automatic Operation When walk tests are complete, the unit can be adjusted for automatic operation : The TIME setting controls how long the unit remains illuminated following activation & after all motion ceases. The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the maximum time (fully clockwise) is approx. 18 minutes. Set the control to the desired setting between these limits. The DUSK control determines the level of darkness required for the unit to start operating. The setting is best achieved by the procedure below: Set the DUSK control knob fully anti-clockwise. The unit will now start operating at dusk. If you require the light to activate earlier, wait until the ambient light level reaches the level of darkness at which you wish the lamp to become operative, SLOWLY (a small step at a time) rotate the control in a clockwise direction until a point is reached where the lamp illuminates. Leave the control set at this point.

At this position, the unit should become operative at approximately the same level of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (i.e. when it is quite light), adjust the control slightly anti-clockwise. If the unit starts to operate too late (i.e. dusk), adjust the control slightly clockwise. Continue to adjust until the unit operates as desired. Once the unit is set up as desired, refit the top cover by aligning the arrows shown on diagram E and twisting clockwise until cover is secure. 8 Manual Override Mode The light can be switched ON for longer time periods by use of the Manual Override Mode. This can be activated at night by using the internal wall switch or circuit breaker. Switch the internal wall switch twice (OFF/ON, OFF/ON) within 2 seconds. The unit will now illuminate continuously until dawn or until it is switched back into Detection Mode. To return to Detection Mode switch the internal wall switch OFF and then back ON again within 1 second. Troubleshooting guide Problem Lamp stays ON all the time at night. PIR keeps activating for no reason (at random). Solution Cover PIR lens with a thick cloth. If the light turns out, check detection area for heat or reflective source. If the light stays ON, check wiring. See Section 3. Turn off at the internal wall switch. Leave for 30 seconds and turn ON again. Leave for at least 18 minutes. If light activates, check area for false activation from heat, wind or reflective source.

9 Problem PIR sensor will not operate at all. The PIR sensor will not operate at night. Unit activates during the daytime PIR coverage is poor/ sporadic Detection range varies from day to day Solution Check that the power is switched ON at the power supply or internal wall switch. Turn OFF the power to the unit and check the wiring connections. Check the lamp. If the lamp has failed, replace. Ensure that the lamp is seated correctly in the lampholder. Please note that the unit will not detect through glass. (e.g. in a glazed porch). The level of ambient light in the area may be too bright to allow operation at the current DUSK setting. During the of darkness, adjust the DUSK control slowly clockwise until the lamp illuminates. Refer to previous section for more details. Adjust the DUSK Control setting anticlockwise to lower the level of ambient light required for activation. Unit may be poorly located. See previous section Selecting a Location and re-locate the unit. PIR detectors are influenced by climatic conditions. The colder the ambient temperature, the more effective the sensor will be. You may need to make seasonal adjustments to the detector head position to ensure trouble-free operation all year round.

10 Technical specifications Detection Range: Up to 6 metres diameter (3m Radius) at mounting height of 2.5m Detection Angle: 360º Power Supply: 230 V AC ~ 50Hz Maximum Switchable Load: 2400W Incandescent/Halogen, 500W Fluorescent, 150W CFL/Low Energy. LED lamps <10W Lamps, max 10. LED lamps >10W <32W, max 5 sets. Not suitable for discharge lighting. 75W Fan Time On Adjustment: 5 seconds 18 minutes Dusk Level Adjustment: Day & night or night only operation Environmental Protection: IP44 (suitable for outdoor use) EC Directives: Conforms to current EC Directives 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515. Note: A proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard) the customer is responsible for all Shipping/Postage charges outside of the UK. All Shipping costs are to be paid in advance before a replacement is sent.

360º Surface Mount Ceiling PIR Light Controller Cat No. SLW360L Installation & Operating Instructions

Introduction The SLW360L utilises passive infrared technology to detect heat radiation of moving human bodies. Upon detection, the attached lighting load will illuminate for a user-determined time period. An integral daylight sensor ensures all day or night-only operation. 1 Important Information: Light Pollution and considerate Lighting Please be aware of the annoyance over-lighting an area can cause to your immediate neighbours. Light pollution caused by incorrectly installing a unit or over-lighting an area can be limited by carefully considering the location and position of your unit before installation. The light spread on all halogen floodlights can be reduced by angling the floodlight downwards on the mounting bracket. This will also concentrate the light on your property and limit the potential inconvenience of the light shining into your neighbours windows etc. Please see Selecting a Location for information on choosing the optimum location for any security light controlled by this unit. A Side View B Side View 2.5m 6m 360º More sensitive C Lens Mask Restrict short detection D Mounting hole Less sensitive Restrict long detection Restrict detection directly under sensor Mounting hole

E Twist cover anti-clock wise Align marks on moulding Remove decorative cover F G L1 Switched Load OUT Factory fitted bridge wire L N E Mains Supply IN 2 H Time On setting L1 L2 Lux -Dusk/ Dawn setting Switched Load OUT Factory fitted bridge wire REMOVED L N E Mains Supply IN In the above illustration: The L1 L2 terminals are used to control a DC load or if the load uses a different phase or voltage supply from the AC mains in. Factory fitted bridge must be removed to isolate L1 & L2 terminals from AC mains in. In the above illustration: 4 core cable may be used there is no external junction box A bridge is provided, prewired to bridge across live supply from AC mains to the output load I Wall plugs x 2. Sponge gasket. Fit if mounting the unit outdoors. Discard if fitting indoors Mounting Plate Sensor Ceiling mount assembly method. Cable gasket Mounting screws Top cover

3 Parts included PIR Sensor unit. Instruction manual. Please keep safe for future reference. Accessory Pack. Includes 2 x wall plugs, 2 x wall fixing screws, 1 x lens mask sticker. 1 x outdoor mounting sealing gasket. 1 x incoming/outgoing wire gasket. Tools and parts needed 3 core flexible cable. Electric/hand-held drill & bits. Terminal or Electricians screwdriver. Large slotted/philips screwdriver. Wire cutters suitable mains interconnect cable. Connected load must not exceed maximum 2400W Incandescent/Halogen, 500W Fluorescent or 150W CFL/Low Energy. LED lamps <10W lamps, Max. 10. LED lamps >10W <32W, max 5. sets. Do not attempt to install if you are suffering from nausea or dizzy spells or on medication with similar side effects. Not suitable for use with discharge lighting. Selecting a location The motion detector has a number of detection zones, at various vertical and horizontal angles as shown (see diagram A). A moving human body needs to cross/enter one of these zones to activate the sensor. The best all-round coverage is achieved with the unit mounted at the optimum height of 2.5m. Careful positioning of the sensor will be required to ensure optimum performance. See diagram A detailing detection range and direction.

4 The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS (see diagram B). Therefore position the unit so that the sensor looks ACROSS the likely approach path. Avoid positioning the sensor where there are any sources of heat in the detection area (extractor fans,tumble dryer exhausts etc.) including opposite any other light sources such as other security lights. Reflective surfaces (i.e. pools of water or white-painted walls) and overhanging branches may cause false activation under extreme conditions. During extreme weather conditions the motion sensor may exhibit unusual behaviour. This does not indicate a fault with the sensor. Once normal weather conditions return, the sensor will resume normal operation. Installation IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation. We recommend this unit be fitted by a qualified electrician. Install in accordance with wiring and current building regulations. Please read the instructions carefully. After choosing a suitable location (see previous section) install the unit as follows: The unit is suitable for connection to a 230 V ac 50Hz electricity supply. It is suggested that 3-core round flexible cable of 1 sq. mm gauge is used. An internal switch should be installed to switch the power to the unit ON & OFF. This allows the sensor to be easily switched off when not required or for maintenance purposes. Remove the top cover of the sensor by twisting the top cover anticlockwise until the arrows shown on diagram E are aligned. The top cover can now be removed from the sensor body.

5 Mark the position of the fitting holes. See diagram G. Drill the holes. Insert the rawl plugs into the holes. PIERCE & PASS THE INCOMING AND OUTGOING CABLE THROUGH THE GROMMET BEFORE SECURING CEILING MOUNTING PLATE TO CEILING. It is recommended that the grommet is pierced with a screwdriver to ensure a better seal. Connection THERE ARE 2 POSSIBLE CONNECTION SCENARIOS 1. Standard connection. See Diagram G. The factory fitted bridge wire must not be removed. Connect the 4 core mains supply cable to the terminal block on the unit as follows:- NEUTRAL(Blue) N EARTH (Green/Yellow) LIVE (Brown) L Connect the fourth core cable or incoming cable from the lighting load to the L1 terminal block on the unit as follows (see connection diagram G) SWITCHED LIVE L1 2. Switching DC loads or loads which use a different phase or voltage supply from the AC mains. See Diagram H. Remove the factory fitted bridge wire. Connect the 3 core mains supply cable to the terminal block on the unit as follows:- NEUTRAL(Blue) N EARTH (Green/Yellow) LIVE (Brown) L Connect the load in series with the load supply between L1 and L2 terminals. Please note that the function of L1 and L2 can viewed as a simple switch controlled by the PIR sensor electronics. When wiring is complete, it is recommended that the ceiling mounting plate is fitted to the sensor body and fixed to the ceiling as follows:-

6 See diagram I for ceiling mounting assembly method. Fit the sensor assembly to the ceiling, if mounting outdoors, it is essential that the sponge gasket is placed between the ceiling mounting plate and the sensor itself to ensure a good seal is maintained. If mounting the unit indoors, the gasket is not required and can be discarded. Insert fixing screws through the sensor assembly into the wall plugs and secure. Do not overtighten, if using a power screwdriver ensure it is set to a low torque setting so as not to damage the unit. Set the unit up as follows, before refitting the decorative cover. Setting up Walk Test Procedure Set the two adjustment controls on the underside of the unit (diagram C) to the following positions: TIME Fully anti-clockwise DUSK Fully clockwise The unit will now operate during daytime as well as at night, illuminating the lamp for approx. 5 seconds each time. This allows testing to be carried out to establish the best position for the sensor. The lamp will immediately illuminate as the unit goes through its warm-up period. After approximately 1 2 minutes the lamp will extinguish. Try to remain outside the detection area during the warm-up period. Walk around the sensor to establish the detection area. The sensor will detect within an approximately six metre diameter circle from the centre of the sensor location. As you cross a detection zone the lamp will illuminate. Now stand still until the lamp extinguishes (this should take approx. 5 seconds). Start moving again. As you cross each zone the lamp will illuminate. Repeat the above, walking at various distances and angles to the unit. This will help you to establish the detection pattern.