THE SLAGGER. Automated self-cleaning cutting table that increases arc-on time by drastically reducing cleaning downtime.

Similar documents
THE SLAGGER. Advanced Cutting Support Table with Automated Slag and Smoke Removal Allowing for Easy Retrieval of Small Parts

CLEARING THE AIR by Jeremiah Wann, president and

The best technical solution for high powder concentrations High level filtering surface and compact design Heavy duty construction for long life in

MESSER DUST COLLECTORS Models 2-8 through 4-128

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

WELD STRONG BREATHE FREE

CUTMASTER. Superior Quality Economical Flexibility Increased Productivity Easy To Use. Automated Plasma Cutting Systems

cutting systems We Bring Intelligence to the Table.TM Victor Thermal Dynamics introduces

AutomAtIoN SerIeS. AutomAted PLASmA. We Bring Intelligence to the Table.TM. Superior Quality Economical Flexibility Increased Productivity Easy To Use

ColorMax Cyclone Cleaning Kit

Prevention of Fires and Explosions in Wood Pellet Facilities. Allen Wagoner, FLAMEX, Inc.

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal

DUST MANAGEMENT CONTAINMENT SUPPRESSION FILTRATION L3423

VARIO eco Dust Collector. For the highly effective, energy efficient collection of dust from industrial processes. Standard for clean air

Thermo Scientific Necropsy Tables

MIST MAX MODEL MM800. Important: Installation and Operation Manual

Clean. Easy. COMPLIANT.

etell Intelligent Controls Advanced Air Quality Controls for Dust Collection Systems

Contractor Safety. Workplace Safety & Environmental Division

MIST MAX MODEL MM2400. Important: Installation and Operation Manual

Metalworking Vacuum Cleaners One Type Does Not Fit All As the metalworking industry becomes more specialized so does the equipment that cleans it.

Ventilation Engineering Analysis. Schust Engineering Project #1845

A Quality & Bankers Quality Door

Electronic Air Cleaner Model Number CSC1000 OWNER S MANUAL. Installation Operation Basic Service Guide Technical Repair Guide Repair Parts

SUBJECT: Effective Date: Procedure Number:

Cutting equipment continues to evolve

HIGH VACUUM - WET MIX DUST COLLECTOR

HumidiPack,HumidiPackPlus and HumidiPackPlus CF Steam Humidifier Systems

M17 HIGH-PERFORMING, VERSATILE BATTERY SWEEPER-SCRUBBER. Effectively clean in just one pass with exceptional sweeping and scrubbing performance.

M17 HIGH-PERFORMING, VERSATILE BATTERY SWEEPER-SCRUBBER. Effectively clean in just one pass with exceptional sweeping and scrubbing performance.

Comfort, Energy & Health Solutions

general brochure

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

Progressive Safety Services LLC 1

Manual Parts Washer. Operating Instructions & Warranty Information

DOWNDRAFT TABLE SERIES SCT

CI2600 PRO-SERIES WOOD INSERT BEST LINEAR STYLING - CI2600 LATEST IN WOOD BURNING TECHNOLOGY SPECIFICATIONS

Machine Protection Door

HLR 1000E Technical Specifications

DUST COLLECTORS & DOWNDRAFT TABLES. A division of BLOWERS

Heat Recovery Ventilators models:

lectronic Air Cleaner

Owner s Manual. Solar-Breeze Robotic Pool Cleaner

TRION Air Purification systems

Dust Collection Tips to Keep Free-From Foods Safe from Cross-Contamination


CARE GUIDANCE. Local Exhaust Ventilation (LEV) Systems for High Temperature Insulation Wool (HTIW) LEVEL 2 RECOMMENDATIONS ON BEST PRACTICE

USER S MANUAL. Wired Remote Controller MWR-WS00. System Air Conditioner ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH EΛΛHNIKA RUSSIAN

Robotic Solutions. Clean Air Solutions for Robotic Welding & Cutting

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

User Manual. Model: FSL200 Laser Fume Extractor

Supplying Clean Air to Industry

CABINET PARTS For Model: KSSO36FMX01 (Etched Aluminum)

NewlyDesignedfor MaximumPerformance

Design Considerations for Abrasive Blast Rooms & Recovery Systems

SELF-SUFFICIENT AIR CARE FOR NEARLY MAINTENANCE-FREE VENTILATION IVEC ULTRA. Clean Air. Only Smarter.

DUST AND FUME COLLECTOR FOR THERMAL CUTTING AND WELDING APPLICATIONS

Introduction Airflow and filtration area General design practices Cleaning system

VIFB Coil Technical Guide

CABINET PARTS For Model: JS42CXFXDB00 (Etched Aluminum)

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Cyclone Dust Collection & Separation INSTALLATION & OPERATION MANUAL

BHA Powerwave Acoustic Cleaning Systems Powerful cleaning to help increase performance

Fume Hood Safety TYPES OF FUME HOODS

Are Your Kitchen Hood Filters Compliant?

DUST COLLECTORS. OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

CABINET PARTS For Model: KBLC36FMS02 (Stainless Steel)

Lead Safety for Renovation, Repair, and Painting. Requirements in the EPA RRP Rule:

F200E Charged-Media Air Cleaner

Eliminator Series. SE400E and SE800E ELECTRONIC AIR PURIFICATION SYSTEM. Electrostatic Precipitators for Commercial Applications

INSTY-PAC EXTERNAL MOUNT WELDED MULTIPLE TUBE ASSEMBLY

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

Volts 115 Wiring Diagram Owner's Guide Eng/Spn Owner's Guide French

INSTY-PAC INTERNAL MOUNT WELDED MULTIPLE TUBE ASSEMBLY

VIFB Coil Technical Guide

P23 MELT CONFINED SPACE LOG

READ AND SAVE THESE INSTRUCTIONS

ABLOY DOOR CLOSERS Exactly the right choice

The reference in sandblasting. SANDBLASTING CABINETS M SERIE pressure TYPE. general brochure

IT S ABOUT TIME FOR FRESH AIR.

FAN SEPARATOR. Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream.

High Performance Door Albany RP2000. ASSA ABLOY Entrance Systems

INSTALLATION AND OPERATIONS MANUAL

c SAFETY CONSIDERATIONS FOR USING POWDER COATINGS

airblastechtips Technical Tips for the Surface Treatment Industry

Plug-n-Play (PNP) CARTRIDGE DUST COLLECTORS.

Winnipeg Fire Department Fire Prevention Branch

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

TABLE OF CONTENTS HOW AIRBORNE CONTAMINATION IS REMOVED 3 DIMENSIONS 4 SPECIFICATIONS 6 PLANNING THE INSTALLATION 7 ASSEMBLY & INSTALLATION 10

the ultimate drying technology

Chilled Water DOAS Fan Powered Terminal Units

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

DUST COLLECTION TRAINING. Revision 2013

Zoning System Design Manual

Module 7. Control of Smoke & Highlights of Code Requirements

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Hot Work Permit. Can this job be avoided? Is there a safer alternative? Permit No.:

ISO INTERNATIONAL STANDARD. Ships and marine technology Fire-extinguishing systems for protection of galley cooking equipment

HYBRID SERIES FURNACES. napoleonheatingandcooling.com

F150E Media Air Cleaner

Transcription:

THE SLAGGER Automated self-cleaning cutting table that increases arc-on time by drastically reducing cleaning downtime.

THE SLAGGER SELF-CLEANING CUTTING TABLE THE SLAGGER BLADE CLEANING MECHANISM Cleaning takes minutes and should be done once per day or shift for best results. THE SLAGGER BLADE Shown moving under a swinging zone divider during the cleaning cycle. THE SLAGGER BLADE Shown pushing slag into Slag Bucket. (Optional) The Slagger Video

OPTIONAL TABLE EQUIPMENT REMOVABLE SLAT TRAY ASSEMBLY Fabricated structure with slats and built-in shields for damper doors allowing slats to be replaced quickly in modules, rather than individually. Drawings available for users to make replacements. Optional designs include standard slats for drilling applications. SLAG BUCKET Fits into a pit located in the floor at the front of the table where slag is deposited at the end of the cleaning cycle. There is one bucket for each Slagger Blade. When the bucket is full, integral lifting eyes can be used to remove and empty the bucket. When not in use, the Slag Bucket and pit is covered by a pneumatically operated door. (Optional) SLAG SCOOP Rests on the floor and is hooked to the front of the table. Slag is pushed into the Slag Scoop at the end of the cleaning cycle and when the scoop is full, integral lifting eyes are used to remove and empty the scoop. (Optional) SLAT RETAINERS Bolted on retainers prevent slats or slat trays from lifting when using a magnet for material handling. TABLE SUPPLIED COMPLETE BY MESSER Includes all components to assemble table complete. SLAGGER TABLE DESIGN PACKAGE BY MESSER INCLUDES: Table side and duct walls. Frame and pneumatic door. Drawings to fabricate all internal table components, slats or slat trays to complete the table. UNIQUE ZONED AND DUCTED TABLE The Slagger includes a zoned downdraft table with mechanically operated damper doors actuated by a cam on the end truck of the machine. The damper doors automatically open as the machine passes over the zone where cutting is occurring. INCREASED EFFICIENCY Zones are automatically activated. Only 50% of any one zone needs to be covered for effective smoke removal and reduced material handling. Covered area must be located near the duct side of the table for best smoke removal. Pass-through zone dividers allow automatic cleaning of slag. Engineered dust collection system provides effective smoke removal for cleaner operation. Illustration of smoke exiting table through side duct

DAMPER DOORS FOR SMOKE AND DUST REMOVAL DAMPER DOORS Actuated by a mechanical cam on the cutting machine. DAMPER DOOR OPEN Inside table view of open damper door after mechanical cam actuation. DAMPER DOOR CLOSED Inside table view of closed damper door without mechanical cam actuation. DUST COLLECTORS Dust collectors are available for use with The Slagger. Smoke is drawn from the table to a cartridge type smoke and dust collector. The size of the dust collector and fan are based on table width and types of cutting torches. On/off functions are automatically controlled by the Global Control or manual switches. Smoke and dust collectors provide a cleaner and safer working environment. SPARK TRAP Placed in the ductwork between the table and the collector capturing hot, heavy particles from the air stream. The particles settle, preventing them from traveling to the collector. Dust Collector CONNECTING DUCTWORK Connects the table, spark trap, and dust collector. Supplied by customer is standard, by Messer is optional. CARTRIDGE STYLE DUST COLLECTOR Fan, filter cartridges, electrical and pneumatic controls automatically clean the cartridges in one unit. Spark Trap Connecting Ductwork Typical Installation

STANDARD TABLE FEATURES THE SLAGGER CUTTING TABLE The Slagger is a patented cutting table developed at Messer Cutting Systems with a leading metal fabrication company. The Slagger automates the removal of slag produced from plasma, oxyfuel and laser cutting. No need to manually clean the table as the Slagger Blade does all the work in minutes. The Slagger Blade is propelled with a positive rack and pinion drive. To clean the table, the operator runs the cutting machine into its park position, which sets the safety circuit. The Slagger drive is then turned on, moving the blade forward with the slag ahead of it. Utilizing a unique design, the Slagger Blade opens and passes under each of the downdraft zone swinging dividers automatically as it passes along. Once the Slagger has passed, the swinging divider returns to its vertical position to restore smoke removal airflow. When the Slagger Blade reaches the end of the table, the slag is pushed outside of the table for disposal. COMPONENTS The Slagger cutting table is a complete package with all the necessary components included to meet your cutting needs. TABLE FRAME AND SUPPORT SURFACE Maximum workpiece thickness for the standard table is 4 (100mm). Tables for thicker material are available. Standard table sizes are available to meet the specific requirements of the cutting machine. THE SLAGGER BLADE Each table is divided into lengthwise bays by the side wall and duct modules. The Slagger Blade runs within each lengthwise bay. Each Slagger Blade unit travels the entire length of the table and pushes slag and small parts out of the table and into a collection area or an optional Slag Bucket or Slag Scoop. AUTOMATIC TABLE CLEANING AND SMALL PARTS RETRIEVAL Table cleaning time reduced up to 95% compared to a water table. Eliminate the need to stop cutting for long periods to remove slag. Small parts that fall through are retrieved during the cleaning cycle without having to reach into the table. Retrieval efficiency is dependent upon part size. The Slagger cleaning time for an average size 12 x 50 (3.7m x 15.25m) cutting table is five minutes, compared to one or two shifts with a conventional water cutting table of the same size. Production is increased and costs are decreased by reduced cleaning time and low labor requirements.

A THE SLAGGER TABLE MEASUREMENTS A Table Width B Table Length * Please contact Messer Cutting Systems for larger table lengths. 7-4 to 24-4 10-8 to 200-0 4-0 B 5-4 Messer Cutting Systems reserves the right to make changes in equipment or specifications at any time without notice. Slagger is a registered trademark of Missouri Valley Steel, a division of Owen Industries. 2017 Messer Cutting Systems Messer Cutting Systems, Inc. W141 N9427 Fountain Boulevard Menomonee Falls, WI 53051 Tel. +1 262-255-5520 Fax +1 262-255-5170 E-mail: sales@messercutting.com www.messer-cs.com Español www.messer-cs.com/mx/us/