technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

Similar documents
technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

Air Conditioners. Technical Data FBQ-C

technical data air conditioning systems Indoor Units FBQ-C7VEB

technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

technical data air conditioning systems Indoor Units FCQ-C8VEB

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

4-WAY BLOW CEILING MOUNTED CASSETTE Daikin air conditioners for shops, restaurants and offices

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

Daikin air conditioners for shops, restaurant and offices

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

EEDEN technical data ERHQ AA. Altherma. Altherma

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

Air conditioners, heating & cooling for shops,restaurants and offices

Daikin air conditioners for your home, shops, restaurants and offices

TABLE OF CONTENTS RMXS-E8V1B

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

Air Conditioners. Technical Data FTXS-G

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

Air conditioners, heating & cooling for the retailmarket and offices

TABLE OF CONTENTS ERSQ-AAY1

technical data air conditioning systems RZQ B8W1B Split Sky Air

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

w w w. d a i k i n. e u ATXS-E

EEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air

EEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air

AIR CONDITIONERS, HEATING & COOLING for your home

technical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air

Air Conditioning Technical Data RZAG-MV1

MOV75984_EPCE02-18 Page 1 8-OCT-02 S Y S T E M S

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

EEDEN technical data EKRTR. Altherma. Altherma

Remote control infrared ARC433B76 ARC433A8 ARC433B69

for small rooms in multi application

Daikin air conditioners for your home

Air Conditioning Technical Data RZASG-MV1

Air Conditioners Technical Data

EEDEN technical data ERHQ AA

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F

for your home FLXS-B Flexi type unit air to air heat pumps

Air Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B

TABLE OF CONTENTS ERHQ BAV3

Daikin air conditioners for your home

Air Conditioning. Technical Data EEDEN AZQS-BV1

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

Air Conditioners Heating & Cooling

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB

PRELIMINARY. w w w. d a i k i n e u r o p e. c o m FDQ-B

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

Air Conditioners Heating & Cooling

Fully Flat Cassette Design & Genius in one

Air Conditioners Technical Data

Daikin air conditioners for your home

Daikin air conditioners for shops, restaurants and offices

technical data air conditioning systems RZQ C7Y1B Split Sky Air

Air Conditioners Heating & Cooling

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

Air Conditioning. Technical Data. Ceiling suspended unit EEDEN AHQ-C

Air Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C

Air Conditioning. Technical Data EEDEN RXS-F8

Air Conditioners Heating & Cooling

for the retail market, hotels, restaurants and offices

Air Conditioners. Technical Data RZQG-L

SiE Service Manual. Split System Air Conditioners SkyAir R-407C Super Inverter 70 D Series. [Applied Models] SkyAir : Inverter Heat Pump

Air Conditioner SVC MANUAL(Exploded View)

DESIGN & TECHNICAL MANUAL

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

Concealed ceiling units

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

Air Conditioners Heating & Cooling

technical data Fan coil unit FWB small duct unit

Daikin air conditioners for shops, restaurants and offices

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

Digital Inverter 4 series 8 & 10HP

DESIGN & TECHNICAL MANUAL

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

Air Conditioners Heating & Cooling

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Fan Coil Units. Technical Data FWC-BT/BF

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTX-J3

Air Conditioning Technical Data AZAS-MY1

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V.

Air Conditioners Technical Data

for your home FTYN-GX FT(Y)N-F

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

DESIGN & TECHNICAL MANUAL

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW

Transcription:

technical data FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) air conditioning systems Split Sky Air

Split - Sky Air ISO400 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO900 standard. ISO900 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin Europe N.V. participates in the Eurovent Certification Programme for Air Conditioners (AC), Liquid Chilling Packages (LCP) and Fan Coil Units (FC); the certified data of certified models are listed in the Eurovent Directory. Specifications are subject to change without prior notice. Zandvoordestraat 300 B - 8400 Ostend Belgium Internet: http://www.daikineurope.com EEDE05-/2 05/2005 Prepared in Belgium by Goekint Graphics

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 TABLE OF CONTENTS FHYCP-B7 Features... 2 2 Specifications... 3 Nominal capacity, capacity steps and nominal input Technical specifications 3 Dimensional drawings... 8 4 Piping diagrams... 9 5 Wiring diagrams... 0 6 Sound level... Sound level data Sound pressure spectrum 7 Air flow patterns & branch duct connections... 3 Air flow patterns duct connections 8 Accessories... 24 Standard accessories Optional accessories 9 Control systems... 27 0 Center of gravity... 28 Safety device settings... 28 2 Installation... 29 For capacity tables, please refer to part II: outdoor units Split - Sky Air Indoor Units

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 Features + Leaves maximum floor and wall space for furniture, decoration and fittings + Fits flush into each ceiling + Can be installed in both new and existing buildings + Extremely quiet in operation both indoors and outdoors + Air can be discharged in any of four directions + Possibility of using or 2 branches for better air distribution + Possibility to shut off or 2 flaps for easy installation in corners + Air flow distribution for ceilling heights up to 4.2m without loss of capacity + For equal distribution in larger rooms, up to 4 indoor units can be connected to outdoor. They are operated from remote control. + Up to 5 indoor units can be connected to Multi outdoor unit. All indoor units are individually controllable with remote control and do not need to be installed in the same room. They operate simultaneously within the same cooling or heating mode. + The wired remote control has following features: - A real time clock - A schedule timer: Á Possibility to program a weekly schedule timer. Á Possibility to program 5 actions for each day of the week. - Limit operation (min./max.): room temperature is controlled within adjustable upper and lower limits. This can be activated manually or by schedule timer. - Home leave (frost protection): during absence, the indoor temperature can be maintained at a certain level. This function can also switch the unit ON/OFF. 2 3 r 8 q x Optional Optional Optional Heat pump 6 5 ) ( 6 4 2 steps FHYCP35-7 2 Split - Sky Air Indoor Units

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 2 Specifications NOMINAL CAPACITY and NOMINAL INPUT For indoor units only: INDOOR UNITS FHYCP35B7V FHYCP45B7V FHYCP60B7V NOMINAL INPUT Cooling kw 0.4 0.6 Heating kw 0.4 0.6 2 For combination indoor + outdoor units (air cooled): INDOOR UNITS FHYCP35B7V FHYCP45B7V FHYCP60B7V OUTDOOR UNITS - - - CAPACITY (3) Cooling kw NOMINAL INPUT Cooling kw EER Twin/triple/double twin application only: RP-L7/B7 ENERGY LABEL ANNUAL ENERGY CONSUMPTION Cooling Cooling kwh For combination indoor + outdoor units (air cooled): INDOOR UNITS FHYCP35B7V FHYCP45B7V FHYCP60B7V OUTDOOR UNITS - - - CAPACITY (3) Cooling kw Heating kw NOMINAL INPUT Cooling kw EER COP ENERGY LABEL ANNUAL ENERGY CONSUMPTION Heating Cooling Heating Cooling kw kwh Twin/triple/double twin application only: RYP-L7 NOMINAL CAPACITY and NOMINAL INPUT For indoor units only: INDOOR UNITS FHYCP7B7V FHYCP00B7V FHYCP25B7V NOMINAL INPUT Cooling kw 0.6 0.204 0.238 Heating kw 0.6 0.204 0.238 For combination indoor + outdoor units (air cooled): INDOOR UNITS FHYCP7B7V FHYCP00B7V FHYCP25B7V OUTDOOR UNITS RP7L7V/W-RP7B7T RP00L7V/W-RP00B7T RP25L7W-RP25B7T CAPACITY (3) Cooling kw 7.0 0.00 2.20 NOMINAL INPUT Cooling kw 2.72/2.66/2.58 3.83/3.56/3.55 4.56/4.58 EER 2.6/2.67/2.75 2.67/2.69/2.76 2.69/2.66 ENERGY LABEL Cooling D/D/D D/D/D D/D ANNUAL ENERGY CONSUMPTION Cooling kwh,360/,330/,290,875/,860/,80 2,265/2,290 For combination indoor + outdoor units (air cooled): INDOOR UNITS FHYCP7B7V FHYCP00B7V FHYCP25B7V OUTDOOR UNITS RYP7L7V/W RYP00L7V/W RYP25L7W CAPACITY (3) Cooling kw 7.0 0.00 2.20 Heating kw 8.00.20 4.60 NOMINAL INPUT Cooling kw 2.72/2.66 3.83/3.56 4.56 Heating kw 2.85/2.80 3.75/3.66 5.06 EER 2.6/2.67 2.6/2.8 2.68 COP 2.8/2.86 2.99/3.06 2.89 ENERGY LABEL Cooling D/D D/D D Heating D/D D/D D ANNUAL ENERGY CONSUMPTION Cooling kwh,360/,330,95/,780 2,280 Split - Sky Air Indoor Units 3

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 2 Specifications 2 TECHNICAL SPECIFICATIONS For indoor units only: INDOOR UNITS FHYCP35B7V FHYCP45B7V FHYCP60B7V DIMENSIONS Unit H mm 230 W mm 840 D mm 840 Decoration panel H mm 40 W mm 950 D mm 950 WEIGHT Unit kg 23 Decoration panel kg 5 MATERIAL Unit Galvanised steel plate COLOUR Decoration panel White SOUND LEVEL Sound pressure (cooling/heating) () FAN high db(a) 3 33 low db(a) 27 28 Sound power (2) db(a) 48 50 Air flow rate (cooling/heating) high m 3 /min 4/4 5/5 8/8 low m 3 /min 0/0 / 4/4 Speed steps 2 steps Type Sirocco fan Qty x motor output W x 45 Drive Direct drive HEAT EXCHANGER Type Cross fin coil J7 Hi-XA tubes Rows x stages x fin pitch mm 2x8x.5 Face area m 2 0.33 AIR FILTER Resin net (with mold resistant) PIPING CONNECTIONS liquid (flare) mm φ6.4 φ9.5 gas (flare) mm φ2.7 φ5.90 drain I.D. mm φ25 drain O.D. mm φ32 INSULATION MATERIAL Heat insulation Both liquid and gas pipes Sound absorbing insulation Foamed polyethylene For outdoor units only: Pair application See chapters RP-L7/B7, RYP-L7 4 Split - Sky Air Indoor Units

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 2 Specifications TECHNICAL SPECIFICATIONS For indoor units only: INDOOR UNITS FHYCP7B7V FHYCP00B7V FHYCP25B7V DIMENSIONS Unit H mm 230 288 W mm 840 D mm 840 Decoration panel H mm 40 W mm 950 D mm 950 WEIGHT Unit kg 23 27 Decoration panel kg 5 MATERIAL Unit Galvanised steel plate COLOUR Decoration panel White SOUND LEVEL Sound pressure (cooling/heating) () FAN high db(a) 33 37 40 low db(a) 28 32 35 Sound power db(a) 50 53 56 Air flow rate (cooling/heating) high m 3 /min 8/8 28/28 3/3 low m 3 /min 4/4 2/2 24/24 Speed steps 2 steps Type Sirocco fan Qty x motor output W x 45 x 90 Drive Direct drive HEAT EXCHANGER Type Cross fin coil J7 Hi-XA tubes Rows x stages x fin pitch mm 2x8x.5 2x2x.5 Face area m 2 0.33 0.497 AIR FILTER Resin net (with mold resistant) PIPING CONNECTIONS liquid (flare) mm φ9.5 gas (flare) mm φ5.90 φ9.0 drain I.D. mm φ25 drain O.D. mm φ32 INSULATION MATERIAL Heat insulation Both liquid and gas pipes Sound absorbing insulation Foamed polyethylene 2 For outdoor units only: Pair application See chapters RP-L7/B7, RYP-L7 Split - Sky Air Indoor Units 5

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 2 Specifications 2 ELECTRICAL SPECIFICATIONS For indoor units only: FHYCP35B7V FHYCP45B7V FHYCP60B7V CURRENT Nominal running current cooling/heating A See chapters RP-L7/B7, RYP-L7 Max. running current cooling/heating A See chapters RP-L7/B7, RYP-L7 For combination indoor units + outdoor units: FHYCP35B7V FHYCP45B7V FHYCP60B7V - - - CURRENT Nominal running current cooling A Maximum running current cooling A Twin/triple/double twin application only: RP-L7/B7 Starting current cooling A For combination indoor units + outdoor units: FHYCP35B7V FHYCP45B7V FHYCP60B7V - - - CURRENT Nominal running current cooling/heating A Maximum running current cooling/heating A Twin/triple/double twin application only: RYP-L7 Starting current cooling/heating A For indoor units only: FHYCP35B7V FHYCP45B7V FHYCP60B7V POWER SUPPLY V V V NOMINAL DISTRIBUTION Phase SYSTEM VOLTAGE Frequency Hz 50 50 50 Voltage V 230 230 230 NOTES Nominal cooling capacities are based on: indoor temperature 27 CDB/9 CWB * outdoor temperature 35 CDB * refrigerant piping length: 7.5m * level difference: 0m. 2 Nominal heating capacities are based on: indoor temperature: 20 CDB * outdoor temperature: 7 CDB/6 CWB * refrigerant piping length: 7.5m * level difference 0m. 3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 4 The sound pressure level is measured at.5m distance from the unit. It is a relative value, depending on the distance and acoustic environment. For measuring conditions: please refer to item 6 of this chapter. 5 The sound power level is an absolute value indicating the power which a sound source generates. 6 Energy label: scale from A (most efficient) to G (less efficient). 7 Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions). 6 Split - Sky Air Indoor Units

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 2 Specifications ELECTRICAL SPECIFICATIONS For indoor units only: FHYCP7B7V FHYCP00B7V FHYCP25B7V CURRENT Nominal running current cooling/heating A See chapters RP-L7/B7, RYP-L7 Maximum running current cooling/heating A See chapters RP-L7/B7, RYP-L7 2 For combination indoor units + outdoor units: FHYCP7B7V FHYCP00B7V FHYCP25B7V RP7L7V/W-RP7B7T RP00L7V/W-RP00B7T RP25L7W-RP25B7T CURRENT Nominal running current cooling A Maximum running current cooling A See chapter RP-L7/B7 Starting current cooling A Note: FHYCP35-45-60BV: Twin/triple/double twin application only For combination indoor units + outdoor units: FHYCP7B7V FHYCP00B7V FHYCP25B7V RYP7L7V/W RYP00L7V/W RYP25L7W CURRENT Nominal running current cooling/heating A Maximum running current cooling/heating A See chapter RYP-L7 Starting current cooling/heating A Note: FHYCP35-45-60BV: Twin/triple/double twin application only For indoor units only: FHYCP7B7V FHYCP00B7V FHYCP25B7V POWER SUPPLY V V V NOMINAL DISTRIBUTION Phase SYSTEM VOLTAGE Frequency Hz 50 50 50 Voltage V 230 230 230 3TW2292-2B NOTES Nominal cooling capacities are based on: indoor temperature 27 CDB/9 CWB * outdoor temperature 35 CDB * refrigerant piping length: 7.5m * level difference: 0m. 2 Nominal heating capacities are based on: indoor temperature: 20 CDB * outdoor temperature: 7 CDB/6 CWB * refrigerant piping length: 7.5m * level difference 0m. 3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. 4 The sound pressure level is measured at.5m distance from the unit. It is a relative value, depending on the distance and acoustic environment. For measuring conditions: please refer to item 6 of this chapter. 5 The sound power level is an absolute value indicating the power which a sound source generates. 6 Energy label: scale from A (most efficient) to G (less efficient). 7 Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions). Split - Sky Air Indoor Units 7

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 3 Dimensional drawings 3 FHYCP35-7B7 Model A B FHYCP35B 6.35 2.70 FHYCP45B 6.35 5.90 FHYCP60B, FHYCP7B 9.52 5.90 Note 3 Prepared hole view C For fresh air intake kit connection (direct installation type) 860 890 (Ceiling opening) 680 Suspension position 300 or less view B Prepared hole duct connection Prepared hole 780 (Suspension position) 860 890 (Ceiling opening) 500 mm or more duct connection view D 500 mm or more Adjustable(0 550) view A 500 mm or more Prepared hole 500 mm or more Required installation space Hanging bolt duct connection 000 mm or more Required service space When the discharge grill is closed, the required space is 200mm or more Note:. Location of unit s name plate Main body: bell mouth inside the suction grille. Decoration panel: panel inner frame inside the suction grille. 2. When installing an optional accessory, refer to the installation drawings. + For fresh air intake kit - inspection port is necessary + For high efficiency filter unit - inspection port is not necessary. + For branch duct chamber - inspection port is not necessary. 3. In case of using an infrared remote control, this position will be a signal receiver. Refer to the drawing of infrared remote control in detail 4. When it may exceed 30 C and RH 80% in the ceiling or fresh air is inducted into the ceiling, an additional insulation (Thickness 0mm or more of glasswool or polyethylene form) is required. Liquid pipe connection JA Flare connection 2 Gas pipe connectionjb Flare connection 3 Drain pipe connection VP25 (O.D. J 32, I.D. J 25) 4 Power supply connection 5 Transmission wiring connection 6 Air discharge grille 7 Air suction grille 8 Water supply intake 9 Corner decoration cover 3TW22834-B 0 Drain hose O.D.J32 FHYCP00-25B7 Model A B FHYCP00,25 9.52 9.0 Note 3 Prepared hole view C For fresh air intake kit connection (direct installation type) 300 or less 860 890 (Ceiling opening) 680 Suspension position view B Prepared hole duct connection Prepared hole 780 (Suspension position) 860 890 (Ceiling opening) 500 mm or more duct connection view D 500 mm or more view A Adjustable(0 550) Prepared hole duct connection Prepared hole 500 mm or more 500 mm or more Required installation space Hanging bolt duct connection 000 mm or more Required service space When the discharge grill is closed, the required space is 200mm or more Note:. Location of unit s name plate Main body: bell mouth inside the suction grille. Decoration panel: panel inner frame inside the suction grille. 2. When installing an optional accessory, refer to the installation drawings. + For fresh air intake kit - inspection port is necessary + For high efficiency filter unit - inspection port is not necessary. + For branch duct chamber - inspection port is not necessary. 3. In case of using an infrared remote control, this position will be a signal receiver. Refer to the drawing of infrared remote control in detail 4. When it may exceed 30 C and RH 80% in the ceiling or fresh air is inducted into the ceiling, an additional insulation (Thickness 0mm or more of glasswool or polyethylene form) is required. Liquid pipe connection JA Flare connection 2 Gas pipe connectionjb Flare connection 3 Drain pipe connection VP25 (O.D. J 32, I.D. J 25) 4 Power supply connection 5 Transmission wiring connection 6 Air discharge grille 7 Air suction grille 8 Water supply intake 9 Corner decoration cover 3TW22874-A 0 Drain hose O.D.J32 8 Split - Sky Air Indoor Units

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 4 Piping diagrams FHYCP35-25B7 Heat exchanger Cooling Heating Refrigerant flow Refrigerant pipe connection port diameters Model Gas Liquid FHYCP35B J2.70 J6.35 FHYCP45B J5.90 J6.35 FHYCP60B, FHYCP7B J5.90 J9.52 FHYCP00B, FHYCP25B J9.0 J9.52 4 Liquid pipe connection port Filter Gas pipe connection port O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe 3TW20435-J Split - Sky Air Indoor Units 9

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 5 Wiring diagrams 5 FHYCP35-25B7 Notes. Use copper conductors only. 2. When using the central remote control, see manual for connection to the unit. 3. X24A is connected when the remote control kit is used. 4. The infrared remote control model varies according to the combination system. See technical data and catalogues before connecting. Outdoor Indoor Norm. emerg. Wired remote control g Field wiring D Terminal F : Connector h : Wire clamp b : Protective earth (screw) Colours BLK: Black / WHT: White / RED: Red / YLW: Yellow Switch box Note 3 Receiver / display unit Outdoor unit Infrared remote control Simultaneous operation system Master Slave Remote On/Off Forced off Fan operation Terminals for operation indicator compressor operation Adapter for wiring 33H AP CR HAP HBP MA M2F M3P QF RT R2T Float switch Printed circuit board Capacitor (M2F) Light emitting diode (service monitor green) Light emitting diode (service monitor green) Motor (swing flap) Motor (indoor fan) Motor (drain pump) Thermo switch (M2F embedded) Thermistor (air) Thermistor (coil) RyP Magnetic relay (M3P) SS Selector switch (emergency) TR Transformer (220-240V/22V) XM Terminal strip (power) X2M Terminal strip (control) = Phase control circuit RC Signal receiver circuit (power) TC Signal transmission circuit (power) Wired remote control SS Selector switch (main/sub) Receiver / display unit (attached to infrared remote control) A2P,A3P Printed circuit board BS Push button (on/off) HP Light emitting diode (on-red) H2P Light emitting diode (timer-green) H3P Light emitting diode (filter sign-red) H4P Light emitting diode (defrost-orange) SS Selector switch (main/sub) SS2 Selector switch (wireless address set) Adapter for wiring RyC,RyF Magnetic relay Connector for optional parts X30A Connector (interface adapter for sky air series) X33A Connector (adapter for wiring) X35A Connector (group control adapter) 3TW22926- NOTES Line voltage wiring Control circuit wiring 2 All wiring, components and materials to be produced on the site must comply with the applicable local and national codes. 3 Use copper conductors only. 4 See wiring diagrams for details. 5 Install fuse and mainswitch for safety. 6 All field wiring and components must be provided by a licensed electrician. 7 The unit shall be grounded in compilance with the applicable local and national codes. 8 Wiring shown are general points-of-connection guides only and are not intended for or to include all details for a specific installation. 9 Never share a common power supply with other equipment. V, Model Power supply 50Hz 220V-240V W, Model Power supply 3N 50Hz 380V-45V T, Model Power supply 50Hz 230V Main switch Main switch Main switch Fuse Fuse Fuse H05VV U4G 4D00992A 0 Split - Sky Air Indoor Units

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 6 Sound level 6- Sound level data Heat pump Model H (cooling/heating) 230V 50Hz L (cooling/heating) Sound pressure level Measuring location Sound power level (H) (cooling/heating) FHYCP35B7 3/3 27/27 48/48 FHYCP45B7 3/3 27/27 Unit 48/48 FHYCP60B7 33/33 28/28 50/50 FHYCP7B7 33/33 28/28 50/50 Microphone FHYCP00B7 37/37 32/32 53/53 FHYCP25B7 40/40 35/35 56/56 6 6- Split - Sky Air Indoor Units

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 6 Sound levels 6 6-2 6-2 Sound pressure spectrum FHYCP35-45 FHYCP60-7 FHYCP00 FHYCP25 Sound pressure level (db) Sound pressure level (db) Sound pressure level (db) Sound pressure level (db) 3TW22837- Octave band center frequency (Hz) 3TW22857- Octave band center frequency (Hz) 3TW22877- Octave band center frequency (Hz) 3TW22887- Octave band center frequency (Hz) NOTES Data is valid at free field condition and nominal operation condition (230V, air discharge in 4 directions). 2 The operation noise differs with the operation and ambient conditions. 3 db(a) = A-weighted sound pressure level (A-scale according to IEC) 4 Reference acoustic pressure 0dB = 20Pa Legend High speed Low speed 2 Split - Sky Air Indoor Units

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 7 Air flow patterns & branch duct connections 7- Air flow patterns FHYCP35B7 Heating - air velocity distribution 4-way discharge, air flow direction: down 7 7- FHYCP35B7 Heating - air temperature distribution 4-way discharge, air flow direction: down 4D0246 Split - Sky Air Indoor Units 3

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 7 Air flow patterns & branch duct connections 7 7-7- Air flow patterns FHYCP45B7 Heating - air velocity distribution 4-way discharge, air flow direction: down FHYCP45B7 Heating - air temperature distribution 4-way discharge, air flow direction: down 4D0247 4 Split - Sky Air Indoor Units

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 7 Air flow patterns & branch duct connections 7- Air flow patterns FHYCP60-7B7 Heating - air velocity distribution 4-way discharge, air flow direction: down 7 7- FHYCP60-7B7 Heating - air temperature distribution 4-way discharge, air flow direction: down 4D0248 Split - Sky Air Indoor Units 5

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 7 Air flow patterns & branch duct connections 7 7-7- Air flow patterns FHYCP00B7 Heating - air velocity distribution 4-way discharge, air flow direction: down FHYCP00B7 Heating - air temperature distribution 4-way discharge, air flow direction: down 4D0249 6 Split - Sky Air Indoor Units

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 7 Air flow patterns & branch duct connections 7- Air flow patterns FHYCP25B7 Heating - air velocity distribution 4-way discharge, air flow direction: down 7 7- FHYCP25B7 Heating - air temperature distribution 4-way discharge, air flow direction: down 4D02420 Split - Sky Air Indoor Units 7

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 7 Air flow patterns & branch duct connections 7 7-2 7-2 duct connections FHYCP-B7 branch duct - 3 way blow Discharge grill: K-DGSC4B (connection: diameter 50mm) Flexible duct K-FDK54B (connection: diameter 50mm, length: 4m) Air volume:,5-2,0 m 3 /min duct Pipe connections branch duct connected (position ) branch duct connected (position 3) branch duct connected (position 2 or 4) Outside static pressure (Pa) Outside static pressure (Pa) Outside static pressure (Pa) Air volume m 3 /min Air volume m 3 /min Air volume m 3 /min 3TW22839-7 8 Split - Sky Air Indoor Units

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 7 Air flow patterns & branch duct connections 7-2 duct connections FHYCP-B7 branch duct - 2 way blow 7 7-2 Discharge grill: K-DGSC4B (connection: diameter 50mm) Flexible duct K-FDK54B (connection: diameter 50mm, length: 4m) Air volume: 2,0-3,0 m 3 /min duct connected (position or 3) - branch closed (position 4) duct connected (position 2) - branch closed (position 4) Outside static pressure (Pa) Outside static pressure (Pa) Air volume m 3 /min Air volume m 3 /min 3TW22839-8 Split - Sky Air Indoor Units 9

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 7 Air flow patterns & branch duct connections 7 7-2 7-2 duct connections FHYCP-B7 2 branch duct - 2 way blow Discharge grill: K-DGSC4B (connection: diameter 50mm) Flexible duct K-FDK54B (connection: diameter 50mm, length: 4m) Air volume: 4,0-5,0 m 3 /min 2 branch ducts connected (position and 4) 2 branch ducts connected (position 3 and 4) 2 branch ducts connected (position 2 and 4) Outside static pressure (Pa) Outside static pressure (Pa) Outside static pressure (Pa) Air volume m 3 /min Air volume m 3 /min Air volume m 3 /min 3TW22839-9 20 Split - Sky Air Indoor Units

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 7 Air flow patterns & branch duct connections 7-2 duct connections FHYCP-B7 branch duct - 3 way blow Discharge grill: K-DGSC4B (connection: diameter 200mm) Flexible duct: K-FDK54B (connection: diameter 200mm, length: 6m) Air volume: 5,0-7,0 m 3 /min 7 7-2 duct Pipe connections branch duct connected (position ) branch duct connected (position 3) branch duct connected (position 2 or 4) Outside static pressure (Pa) Outside static pressure (Pa) Outside static pressure (Pa) Air volume m 3 /min Air volume m 3 /min Air volume m 3 /min 3TW22879-7 Split - Sky Air Indoor Units 2

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 7 Air flow patterns & branch duct connections 7 7-2 7-2 duct connections FHYCP-B7 branch duct - 2 way blow Discharge grill: K-DGSC4B (connection: diameter 200mm) Flexible duct: K-FDK54B (connection: diameter 200mm, length: 6m) Air volume: 7,0-0,0 m 3 /min duct connected (position, 2 or 3) - branch closed (position 4) Outside static pressure (Pa) Air volume m 3 /min 3TW22879-8 22 Split - Sky Air Indoor Units

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 7 Air flow patterns & branch duct connections 7-2 duct connections FHYCP-B7 2 branch duct - 2 way blow Discharge grill: K-DGSC4B (connection: diameter 200mm) Flexible duct: K-FDK54B (connection: diameter 200mm, length: 6m) Air volume: 9,0-,0 m 3 /min 7 7-2 2 branch ducts connected (4 and or 4 and 2 or 4 and 3) Outside static pressure (Pa) Air volume m 3 /min 3TW22879-9 Split - Sky Air Indoor Units 23

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 8 Accessories 8 8-8- Standard accessories Check if the following accessories are included with your unit. Also used as packing material Clamp pc. Paper pattern for installation pc. Drain hose pc. Screws M5 For paper pattern for installation 4 pcs. Washer for hanging bracket 8 pcs. Sealing 2 pcs. Insulation for fitting of each Other: installation manual, operation manual For gas pipe For liquid pipe 24 Split - Sky Air Indoor Units

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 8 Accessories 8-2 Optional accessories Options Item Model FHYCP35 FHYCP45 FHYCP60 FHYCP7 FHYCP00 FHYCP25 Decoration panel BYC25K7WB Filter related High efficiency filter 65% Colorimetric method KAFJ556K80 KAFJ556K60 High efficiency filter 90% Colorimetric method KAFJ557K80 KAFJ557K60 Replacement high effiency filter 65% Colorimetric method KAFJ552K80 KAFJ552K60 Replacement high effiency filter 90% Colorimetric method KAFJ553K80 KAFJ553K60 Filter chamber KDDFJ55K60 Replacement long-life filter Non-woven type KAFJ55K60 Ultra-long life filter KAFJ55K60 Replacement ultra long-life filter KAFJ55K60H Fresh air intake kit Chamber type Without T-shape and fan KDDJ55B60 With T-shape, and fan KDDJ55B60F With T-shape, without fan KDDJ55B6OK Direct installation type KDDJ55X60 Sealing member of air discharge outlet KDBHJ55B60 Panel spacer KDBJ55K60W duct chamber KDJ55B80 KDJ55B60 Chamber connection kit KKSJ55K60 8 8-2 Control systems Item Model FHYCP35 FHYCP45 FHYCP60 FHYCP7 FHYCP00 FHYCP25 Remote control Infrared Heat pump BRC7C52W Cooling only BRC7C53W Wired BRCD527 Wiring adapter (hour meter) * EKRPB2 Wiring adaptor for electrical appendices *2 KRPB57 Wiring adaptor for electrical appendices *2 KRP4A53 Remote sensor KRCS0- Installation box for adapter PCB KRPC98 Central remote control DCS302C5 Electrical box with earth terminal (3 blocks) KJB3A Unified ON/OFF control DCS30B5 Electrical box with earth terminal (2 blocks) KJB22A Noise filter (for electromagnetic interface use only) KEK26- Schedule timer DST30B5 Interface adapter for Sky Air series DTA02A52 Remote ON/OFF, forced OFF EKRORO * Possibility to connect an hour meter. This part should not be installed inside the equipment. *2 Installation box for adapter PCB (KRPC93) is necessary. 3TW22839-6B Split - Sky Air Indoor Units 25

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 8 Accessories 8 8-2 8-2 Optional accessories Specifications EKRORO Wire specifications Connector (White) connect to indoor PCB (X40A) White connect to on/off switch AWG24 0.22mm 2 White Operating method ON* Switch Unit Input Remote control Standard setting: forced off Alternative setting: on/off OFF ON OFF ON OFF ON OFF * Input ON = closed contact. Forced off Input on stops operation + disables control Input off enables control On/off operation Input off on: starts operation, remote control is still enabled. Input on off: stops operation, remote control is still enabled. Selection of FORCED OFF and ON/OFF operation Setting Mode NO First code NO Second code NO Forced off 2 (22) 0 On/off operation 02 4TW2394-26 Split - Sky Air Indoor Units

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 9 Control systems 9- Wired remote control BRCD527 9 9-5 x 0 (Round end slit) 6.5 x 9 (Round end slit) Cover closed 5 x 7 (Round end slit) HoleJ5 Cover open 3TW2365-2 Split - Sky Air Indoor Units 27

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 0 Center of gravity 0 Model A B FHYCP35-7B7 230 90 FHYCP00-25B7 288 20 4TW22839-2A Safety device settings FHYCP-B7 Model Safety devices 35 45 60 7 00 25 Fan motor thermal protector ( C) OFF: 30±5 ON: 80±20 OFF: 30±5 ON: 80±20 OFF: 30±5 ON: 80±20 OFF: 30±5 ON: 80±20 OFF: 30±5 ON: 80±20 Drain pump fuse ( C) 45 45 45 45 45 45 OFF: 30±5 ON: 80±20 3TW2283-3A 28 Split - Sky Air Indoor Units

4-Way Blow Ceiling Mounted Cassette R-407C FHYCP7-25B7 2 Installation FHYCP-B7 2 Number Description Indoor unit 2 Outdoor unit 3 Wired remote control 4 Inlet air 5 Discharged air 6 Refrigerant piping, connection electric wire 7 Drain pipe Ground wire 8 Wire to ground from the outdoor unit to prevent electrical shocks. 9 Air filter Split - Sky Air Indoor Units 29