Evolution Product Range

Similar documents
Salsmästaregatan 21 P.O. Box 8763 SE Gothenburg

Touch Screen 1 loop Addressable Fire Alarm Panel

Evolution Analogue Addressable Fire System

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

Consultant Specification AGILE Wireless Fire Detection System

evolution EV-H ANALOGUE ADDRESSABLE HEAT SENSOR INSTRUCTION MANUAL LPCB REF: 041h/01&02 and 842c/03&04

GO TOGETHER WITH CONSILIUM SUPERIOR ROLLING STOCK SAFETY SOLUTIONS

NITTAN. EVOLUTION April 2009 EVC-DP Conventional Dual Optical Detector TECHNICAL DATASHEET. Part Numbers and Product Order Codes:Part Number

AU MX Digital Loop Card Installation Instructions

Sita200plus. 200detectors. Single loop analogue addressable System

Wireless Fire & Security Solutions. Fire Product Showcase

Automatisk Branddetekterings- og Alarm-system Automatic Fire Detection and Alarm System

Solution F2. Fire Alarm Control Panels one step ahead.

Wireless Fire & Security Solutions. Fire Product Showcase

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Intelligent Addressable Fire Alarm System

System 800 Addressable Fire Detection & Alarm System

NAM-AS3 LOOP POWERED INPUT MODULE INSTALLATION & TECHNICAL MANUAL

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

CODESEC FIRE ALARM SYSTEMS. security technologies

Product Guide MAN7030-2

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

MINERVA MZX125 Digital Addressable Fire Detection System

SOUNDER CONTROL MODULE SCM-AS4

Instruction Manual EVA-PY

Conventional Fire Alarm System 2014 V1.2

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Cerberus FIT conventional system

Intelligent addressable fire alarm control panel

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

Product Catalogue. Version 4

Emergi-Lite Orbis detectors

Loop units. a wide range covering your basic fire detection needs

Wireless Fire Solutions

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

850 and 830 Series. Generation 6

Salwico CS4000. Fire detection system solutions for demanding customers. Fully addressable Built-in saftey Extended redundancy function

Intelligent Security & Fire Ltd

850 Series Fire Detectors - Generation 6

INTELLIGENT FIRE TECHNOLOGY

MINERVA MZX125. Digital Addressable Fire Detection System

Analogue addressable devices

Synova TM product catalog.

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

850 and 830 Series. Fire Detectors - Generation 6

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

MINERVA MX. 800 Series Ancillary Equipment

Quick Selection Guide Fire Systems LSN Periphery

OPERATION AND ALARM PANELS

830 Series. Fire Detectors - Generation 6

Vega Devices.

>WIRELESS> ALARM SYSTEM CR200

arm wire free solutions nurse call personal security fire alarms

Addressable and Conventional Fire Protection

The complete conventional fire warning system

Automatic Fire Alarm System

ZITON RADIO LOOP MODULE

Type Product Certificate Remarks

Basic Fire Alarm SystemTraining. Arman Alnasar

Instruction Manual EVA-DPH

1) This manual covers 4400, 5400 and 6400 fire alarm systems. The differences are described in the appropriate sections.

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

Scope. Warning sounders except specific requirements. Intercom Systems for Emergency Purposes. Sound Systems for Emergency Purposes

Fire alarm systems. detect. Fire fighting security systems

Analogue Detectors. Series 200 plus

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

Fire protection for rolling stock. Innovative solutions from Siemens Building Technologies. Answers for infrastructure and cities.

850 and 830 Series. Generation 6

Availability, Reliability, False Alarm Resistance Best Practice in Fire Alarm Systems. FIRE PROTECTION OF ROLLING STOCK 2 rd March 2017

Welcome to Morley IAS Fire Systems

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

INSTALLATION & MAINTENANCE of FIRE ALARM SYSTEMS

IGD.CO.UK

Conventional Audible Visual Range

TRIPLE WAVEBAND INFRARED FLAME DETECTOR

APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

Vigilant MX4428 Fire Alarm System

FEC400 Series. Installation Manual

830 Series Fire Detectors

Who we are? Spanish fire alarm systems manufacturer. Engineering team with more than 20 years of experience in the fire detection field.

FireClass. Introducing a new class of fire detection

5000 INSTALLATION GUIDE

Type approval testing of miscellaneous smoke and heat detectors for marine applications

Certificate of Conformity Certificate num. Registration date Version Valid until

EFBW series - BiWire Ultra control panel

Standard detectors. General information. Product Sheet Detec on

Fire detection and alarm

The EN54 Part 2 and 4 Fire System

Installation, Operating and Maintenance Manual

OH110, OP110, HI110 Automatic fire detectors

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

GST Headquarters. GST Production Base

OH720, OP720, HI720, HI722

Fire Product Catalog

XP95/Series 90 Test Set

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

Transcription:

Evolution Product Range World Leading Fire Detection Products from the NITTAN group

Analogue Products Smoke / Heat / Flame Sensors CN-P Optical Smoke Detector CN-PH Optical Smoke and Heat Detector Optical smoke and Heat sensors (A1R) in one housing CN-DP Dual Optical Smoke Detector Dual Optical Technology reduces False Alarms CN-DPH Dual Optical Smoke/Heat Detector Dual Optical Technology reduces False Alarms Heat Detector (A2R) EEPROM Addressed (Programmer) 2

Smoke / Heat / Flame Sensors CN-H-A1R Optical Heat Detector Differential Heat detector 54 C CN-H-CS Optical Heat Detector Static response Heat detector 84 C CN-ps-DSCI Optical Smoke Detector with Sounder and SCI Built in Sounder and Dual Line SCI Detection products mechanically compatible to products over 20 years old 3

Analogue Products MCP s / Isolators/ I/O Devices UB-6 Universal base EVC/CN Detectors Low Profile STB-4SE High Profile base EVC/CN Detectors Wide options of installation types MCP-A Manual Call Point IP24 (With Isolator) DIP Switch Addressed MCp-A IP67 Manual Call Point Waterproof (With Isolator) DIP Switch Addressed CN-BI Base with SCI Suitable for conventional and addressable detector EEPROM Addressed (Programmer) 4 CN-AIOI Control and Indication Unit Conventional detector interface DIP Switch Addressed 2A@24Vp Relay contacts Housing IP67

Alarm Devices / Tools CN-SB Base Combined Sounder and Beacon with integral Base and SCI (With SCI) CN-sb Combined Sounder and Beacon (With SCI) CN-Programmer Addressing tool Address Programmer for Evolution range Battery operated SE-3000+ Loop tester Evolution loop start up tool Diagnose a loop without access to panel Battery operated 5

Conventional Products EVC-P Optical Smoke Detector EVC-DP Dual Optical Smoke Detector Dual Optical Technology reduces False Alarms Wide Operational Voltage Range (16v-28v) EVC-H-A2S Optical Heat Detector Differential Heat detector 54 C EVC-H-CS Optical Heat Detector Static response Heat detector 84 C EVC-IR Flame Detector Infra Red Wide Operational Voltage Range (10v-30v) Dual Band IR Flame Detector 6

Detection products mechanically compatible to products over 20 years old UB-6 Universal Base EVC/CN Detectors Low Profile STB-4SE High Profile Base EVC/CN Detectors Wide options of installions types MCP-CO Conventional Manual Call Point IP24 MCP-C IP67 Conventional Manual Call Point Waterproof Waterproof 7

CN System AB CN System AB is a joint-venture between Consilium AB (Sweden) and Nittan Ltd. (Japan), both world market leaders within their own niches (Fire Detection Systems and Fire Detectors). CN System AB distributes EN-54 and CPD approved Fire Detection Systems (supplied by Consilium AB) and highly advanced Fire Detectors (supplied by Nittan Group) on OEM-basis. CN System Offices For specific inquiries about our products, services or company, please contact the office nearest to you. SWEDEN CN System AB Phone: +46 31 28 59 40 Email sales: sales@cnsystem.se Email service: service@cnsystem.se NORWAY CN System Norway AS Phone: +47 22 30 90 15 Email sales: sales@cnsystem.no Email service: service@cnsystem.no CN System AB Södra Långebergsgatan 34 SE-421 32 Västra Frölunda Sweden Phone: +46 31 28 59 40 Fax: +46 31 28 85 95 www.cnsystem.se