GO TOGETHER WITH CONSILIUM SUPERIOR ROLLING STOCK SAFETY SOLUTIONS

Similar documents
designed for rail 5000 Series

Fire protection for rolling stock. Innovative solutions from Siemens Building Technologies. Answers for infrastructure and cities.

Evolution Analogue Addressable Fire System

Evolution Product Range

Touch Screen 1 loop Addressable Fire Alarm Panel

Consultant Specification AGILE Wireless Fire Detection System

HART XL High Sensitivity Smoke Detection

Modular Fire Panel 5000 Series Just as flexible as your plans

Different types of Fire Alarm System

Just as flexible as your plans The Bosch Modular Fire Panel 5000 Series

Solution F2. Fire Alarm Control Panels one step ahead.

For Complete Fire and Gas Solutions

ON-TRACK FOR TAILORED FIRE PROTECTION. Future-proof fire protection solutions for rail vehicles

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

F&G detection system for LNG plants

SUPREMATouch. Modular Fire & Gas Detection System

Intelligent addressable fire alarm control panel

SUPREMATouch. Modular Fire & Gas Detection System

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Dräger REGARD -1 Control System

HART XL High Sensitivity Smoke Detection

Quick Selection Guide Fire Systems LSN Periphery

FAAST. Fire Alarm Aspirating Sensing Technology

MINERVA MZX125 Digital Addressable Fire Detection System

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Fire alarm system EBL512 G3

Fire Detection systems. UniVario industrial fire detectors for every job

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

FOGTEC Rail Systems. Rolling Stock Applications. Fire Protection Solutions from one source. Leading in Fire Protection

WG Buried Cable Perimeter Detection System

FAAST. Fire Alarm Aspirating Sensing Technology

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

INPUT / OUTPUT MINI MODULES

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

COMPANY PROFILE Technoswitch with its headquarters, manufacturing and training facilities in Johannesburg, has been supplying and providing technical

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

FAAST. Fire Alarm Aspiration Sensing Technology

Fire Protection Systems For Railway Vehicles WE ARE ENSURING FIRE SAFETY

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

CODESEC FIRE ALARM SYSTEMS. security technologies

Flexible Air-sampling Smoke Detection

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

Vigilant MX4428 Fire Alarm System

Dräger Flame 2100 Flame Detection

2004 AUSTRALIAN STANDARDS UPDATE

Protect your people, assets and environment while ensuring operational performance.

Fire detection and alarm

FDOOT241-A9-Ex Multisensor fire detector

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

AUTROSAFE. An interactive fire detection system for larger vessels

Dependable Solutions for Gas Detection

Availability, Reliability, False Alarm Resistance Best Practice in Fire Alarm Systems. FIRE PROTECTION OF ROLLING STOCK 2 rd March 2017

The Amerex Advantage - Quality Experienced Innovation Made in the USA

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

Industrial Grade Gas Detection

How can you minimize consequential damages in case of a fire?

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

MSA Fixed Gas & Flame Detection for the Automotive Industry

Building Technologies

TX7100. Intelligent Addressable Optical Smoke Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Addressable Loop Powered Visual Alarm Devices

Industrial Grade Gas Detection Detecting The Difference

intelligent fire alarm ID60series panels

Cerberus FIT conventional system

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

UniVario Industrial Fire Detectors Versatile in Application

EXTINGUISHING SYSTEM DETECTION AND CONTROL

YOUR PARTNER IN FIRE & GAS DETECTION

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Basic Vehicle Fire Protection Manual

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

Intelligent Earliest Warning Aspirating Fire Detector

Aspir A ation spir P R O D U C T S

Fire and Gas Monitoring Panel ST7-HV

On the job around the clock 24/7: Fire detection systems

MINERVA MZX125. Digital Addressable Fire Detection System

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

CerberusTM. PRO intelligent protection. A comprehensive fire protection system. Answers for infrastructure.

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Dräger Flame 2500 Flame Detection

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL

Product Range. Talentum - Why use our Flame Detectors? Product Support. Warranty.

OFFSHORE SUPPORT VESSELS 2014

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Cerberus PRO enjoy protecting A comprehensive fire protection system

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

Dräger REGARD -1 Control System

ID50series. intelligent fire alarm panels

Installation, Operating and Maintenance Manual

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

LaserFOCUS VLF-250 Engineering Specification

Sita200plus. 200detectors. Single loop analogue addressable System

Analogue addressable devices

Corporate Expertise. From the global experts in quality, technology and total cost of ownership of fire detectors.

Why Hart XL Aspirating Smoke Detection?

Transcription:

GO TOGETHER WITH CONSILIUM SUPERIOR ROLLING STOCK SAFETY SOLUTIONS When Safety Matters

GO TOGETHER WITH CONSILIUM FOR A SAFER JOURNEY Consilium is a global niche company that develops, manufactures, markets products and systems that are used to protect people, material values and the environment. Consilium s entire offering is based on delivering high-quality applications to customers, who need to protect complex environments with high material values and large numbers of people. Our vision is for customers to make Consilium their first choice - When Safety Matters. Consilium supplies fire detection and protection systems to all different segments within Rolling Stock, from ultra-high speed trains to trams and locomotives. In our portfolio we also deliver fire protections systems to trucks and buses. We aim to lead the development for our customer s best interest and also focusing on innovation, we have therefore developed a first class system that is SIL 2 and RAMS approved superior Rolling Stock safety solutions. Your trustworthy partner As a worldwide market leader, Consilium deliver long experience, in-depth knowledge of safety solutions within Rolling Stock. We give you the ticket to go together with Consilium throughout the years as your partner. Long term relationship Consilium s systems are flexible, module based, tailor made and proven in use and we support our customer throughout the whole train s life cycle. Our global support network With a global market organisation, Consilium can offer its customers local installations, local services and support wherever in the world whenever and wherever you need it. Consilium today protects over 16 000 train cars around the world 24/7/365 NEW LAWS, LEGISLATIONS AND STANDARDS New standards One of the latest news for the European market is the release of the EN 45545-1 to-7 standards Fire protection on railway vehicles. These standards covers fire protection aspects from the requirements of fire properties of materials, to the overall design of the vehicles. This release, together with the standard EN 50553 Requirements for running capability in case of fire on board rolling stock, supports in setting the requirements when operating trains in tunnels or on elevated structures. It should be noted, that the directive and standards only specifies that it supports the safe evacuation of passengers and staff and not the protection of the investments in vehicles, infrastructure and operation nor the environment. Protecting the environment Even if the protection of passengers and staff comes first, all train manufacturers and operators do what is practically possible to have a total protection of the full investment and environment. Preventing fire by implementing a proper fire protection system, can be the investment with the biggest impact on the protection of the environment. RAMS AND SIL RAMS The European standards EN 50126, EN 50128 and EN 50129 known as RAMS, are becoming increasingly important within the railway industry, focusing on life cycle cost and safety. These standards are the basis for qualified modern assessment of Reliability, Availability, Maintainability and Safety (RAMS). Focusing on RAMS, Consilium has implemented RAMS processes throughout its organisation, meeting the modern requirements of the railway industries. New products have been developed according to the RAMS standards with the highest Reliability, Availability, Maintainability and Safety in mind offering train manufacturers a fire detection system with a low life cycle cost and a high safety integrity level. Safety Integrity Level (SIL) SIL is defined as a relative level of risk-reduction provided by a safety function or to specify a target level of risk reduction. The technical progression in the railway industry, including unmanned operating rolling stock, puts a higher demand on the safety function in case of fire. SIL analyses are designed to verify that the measures and operational rules are sufficient for achieving a prescribed SIL, ensuring risk reduction. Consilium s products comply with the harmonized standard EN 50128 and EN 50129 referring to the Safety Integrity Level, offer safety functions up to SIL 2. When Safety Matters SIL 2 IEC 61508/EN 50126/28/29 RAMS EN50126/EN50128/EN50129 2 3

MODULES OVERVIEW CONTROL MODULES The control unit is the main part of the system containing all functionality for detection, alarm, controls and the main operator interface. The control unit communicates with other interface modules on a redundant bus system. The system can also be connected, and controlled directly through the TCMS via high-speed interfaces such as Ethernet 10/100 or RS485. Control modules Repeater model Interface modules SIL modules SIL 2 The following parameters can e.g. be downloaded and configured: Number of detectors and other loop units Sensor sensitivity and alarm delay Number of operator interfaces and indication units Digital output/input functionality Multiple language control Explanatory text, which can be assigned to each detector. The text is displayed on the operator interface at alarm or fault. It is also possible to define texts for digital inputs and outputs CM 2.2 RM 4.3 Loop MX CS - Loop M CM 2.2 CM 4.3 CM 4.3 Bus Isolator M CS - Safety M Relay M 8 DIN-rail mounted control module, easily integrated with other modules. Small design, perfect for installtion in narrow spaces as well as in refurbishment projects. Offers the same functions as a full size fire alarm system. Large colour graphical display with full compliance with the European Fire Alarm Standard EN 54. The central unit is delivered in a cabinet, for both flush and surface mount installation. Suitable when communication with train control and montoring system (TCMS) is limited. I/O M 70 and I/O M 700 REPEATER MODULE The repeater module is used when information wants to be shared to other parts of the train, such as staff room or other staff accessed areas. Charger M RM 4.3 The RM 4.3 is a repeater panel with a 4.3 graphical colour display used to indicate system status. The unit is connected to the redundant backbone bus or Ethernet and can therefore be independently mounted remotely from the central unit. RM 4.3 can be used in a CM 2.2 or a CM 4.3 system solution. Surge Prot M 4 5

INTERFACE MODULES The interface modules are used to build up the different need of interfaces. The different modules are developed to support different functions in the system and are added on to meet the customers needs and requirements. Modules can be added on later for future expansions. Charger M The Charger M module provides redundant power to the system through the redundant backbone bus and also supervises the external power sources. The Charger M has a built in intelligent battery charger for handling of backup battery power source of the system. Loop Mx I/O M 70 and I/O M 700 The Loop Mx module includes one addressable detector loop interface handling up to 254 addressable detectors and/or other loop units. Module activity can easily be monitored on the fault and alarm indicators on the front panel as well as on the display of the control unit. Up to 64 Loop Mx modules can be connected to one central unit. The loop interfaces are using FSK modulation which is extremely robust making cable lengths up to 3000 m possible, with no specific cable requirements. The cable with its detectors and other loop units are continuously monitored for possible faults and disturbances providing the highest possible safety. The I/O M 70 and I/O M 700 modules are two types of I/O modules with eight identical and individually programmable input/output channels. I/O M 70 and I/O M 700 is used as digital input and output modules for monitoring and control of external devices. Such as alarm devices, fire barriers, extinguishing and suppression systems, doors and custom made mimic repeater panels, HVAC etc. Maximum output current per channel is 70 ma for I/O M 70 and 700 ma for I/O M 700 and it s possible to bridge up to 2100 ma. Bus Isolator M SIL MODULES The Charger M is equipped with a supervised high current optically isolated output with a maximum of 8 Ampere. The Bus Isolator M module divides the redundant system backbone bus into electrically isolated segments. Its dual functionality isolates communication and basic backup signals between the distributed system parts creating effective EMC isolation from the surrounding environment. Bus Isolator M is mandatory when extracting the system backbone bus using separate power sources for the different segments in order to preventing interference caused by ground currents or other equipment. Consilium SIL fire detection system offers a platform with a safety function complying with up to SIL level 2. All loop units and detectors have built in short circuit isolators and Built-In Self-Test (BIST) in the detectors to improve the reliability of the system. The solution supports both redundant and single loop setup. All loop units are addressable to give individual fire and fault localization on a detailed level for easy maintenance. The SIL fire detection system is possible to integrate with the standard system using other modules in the platform to create the optimal system. Relay M 8 The Relay M 8 module contains eight individually programmable relays. Each one of these relays provides a potential free change-over-contact capable of a 5A resistive load. Use Relay M 8 for control units such as sirens, doors, flash lights, alarms and HVAC or where general dry contacts are required. CS-Loop M SIL 2 The CS-Loop M module includes one addressable loop interface handling in general up to 150 addressable detectors or other loop units. The loop interface are using FSK modulation which is extremely robust making cable lengths up to 2000 meters possible, with no specific cable requirements. CS-Loop M supports both redundant and single loop configuration for maximum safety. Surge Prot M CS-Safety M SIL 2 The Surge prot M module unit is a terminal board with four major functions: Surge protection for power inputs Terminal board for CM 4.3 Electronic short circuit protected for power outputs Provides power to the backbone bus The module is designed to be used where there are no requirements for electrical isolation between devices. The CS-Safety M module is an interface module and data collector for systems with more than one CS-Loop M offering centralized outputs for fire, fault and disablements. The module offers a SIL 2 classed protocol that can be run on RS485 or Ethernet. CS-Safety M supports both single and redundant setup with redundant data sharing with TCMS. 6 7

ADDRESSABLE LOOP UNITS Consilium s detectors and I/O units from the well-established fire alarm product range for rail, marine and industrial applications in harsh environments can be connected to the fire detection loop. In addition to this, the communication interface of the loop units is based on Frequency Shift Keying (FSK) modulation, which has proven outstanding performance in harsh electrical environments. Combined smoke/heat detector EV-PP Address unit IC 10 The Consilium EV-PP is designed to give early warning in case of heat and/or smoke. Both heat and smoke alarm can be generated individually. At the same time, EV-PP offers a high protection against unwanted alarms. The detector has one configurable I/O for local control. The IC 10 is an address unit for fire detector loops. It has been designed for use in damp spaces. This unit allows the connection of different types of devices with closing digital function to the fire alarm system, for example high temperature heat detector as LHD cable. IC 10 includes one input. IR flame detector with addressable base This IR detector is a triple frequency infra-red flame detector using the latest technology. The detector is made for detection of smokeless combustible liquid and gas fires, as well as smoke-forming open fire involving carbonaceous materials as contained in wood, plastics, gases, oil products etc. The detector is using intelligent signal processing and custom algorithms, achieving excellent detection reliability while maintaining the highest immunity to interference radiation and sunlight. IR detector s is suitable for harsh environments such as engine compartments or environments with high IP demands. The IR detector is used with an IP67 Addressable base to connect it to the detector loop. Manual call point MCP-A MCP-A is an addressable manual call point available in different housings offering ingress protection for different environments. The unit provides the required system functionality for passenger activated emergency alert. LED on the front of the call point indicates the fire alarm being activated. The MCP-A provides optional built-in double sided short-circuit isolation. Dual smoke detector EV-DP Address unit IC 44 The unique Consilium EV-DP is a detector with a dual wavelength optical chamber. Two light sources with different wavelengths are used which gives the detector a reliable reaction to different kinds of smoke, making it insensitive to unwanted alarms caused by for example water steam. The addressable I/O control unit IC 44 is designed to control and monitor external devices, sush as fire doors, watermist, aerosols, HVAC etc. The control unit is connected to a loop in the same way as other fire alarm loop units and can be used in damp spaces. The IC 44 includes four inputs and four relay outputs. Aspiration detector ASP-02 The aspiration box is used to sample and analyze the presence of smoke by using a built in fan which continuously gathers air samples into the detection chamber via the pipe network. ASP-02 uses one pipe per box to give a precise position of the alarm. The fan inside the aspiration box is continuously supervised in order to give fault indication in case of any disturbance caused in the aspiration box. ASP-02 is very suitable for use in areas with limited space or where the detector can be exposed to mechanical damage, tough environmental conditions or vandalism. The robust design, light weight and small size make it very attractive for railway applications. Short circuit isolator NMI-SCI NMI-SCI is a double isolating short circuit isolator. A pair of short circuit isolator electrically isolates a short circuit occurring on the loop giving full availability and function to the unaffected loop despite the short circuit. The short circuit is indicated on the unit and on the control panel. NMI-SCI is installed on the loop between detectors and loop units, where short circuits or disturbances on the loop can be expected, for example at the interconnection between the vehicles in the train creating safety sectioning of the train set.the short circuit isolator is mandatory for redundant loop configurations. 8 9

SIL ADDRESSABLE LOOP UNITS SIL 2 NON ADDRESSABLE DEVICES Combined multi-function smoke/heat detector CS-PYH The CS-PYH is designed to give early warning in case of heat and/or smoke and offers a high protection against unwanted alarms. The CS-PYH offers a variety of functions to be optimized for the installed environment. One configurable in/output is provided for local indication and data input, for devices and systems such as suppression, extinguishing as well as fire barriers and local. In the range of detectors there are also non addressable types which can be connected to conventional lines, addressable IO s or used as stand alone. CS-ASP The aspiration box is used to sample and analyze the presence of smoke by using a built in fan which continuously gathers air samples into the detection chamber via the pipe network. CS-ASP-03 uses one pipe per box to give a precise position of the alarm. The flow inside the aspiration box is continuously supervised in order to give fault indication in case of any disturbance caused in the aspiration flow. CS-ASP-03 is very suitable for use in areas with limited space or where the detector can be exposed to mechanical damage, tough environmental conditions or vandalism. The robust design, light weight and small size make it very attractive for railway applications. Thermal detector HC100 The Consilium HC100 is an II I G EEx ia IIC T5 intrinsically Safe conventional heat detector. The detector is designed for use in areas with high explosion risk. HC100 has a high resistance against humidity and vibrations and is suitable for location in harsh environments. Input interface loop unit CS-IC10-SS The CS-IC10-SS is a unit for various integration of safety inputs. It has been designed for use in damp spaces. This unit allows the connection of different types of devices with closing digital function to the fire alarm system, for example high temperature heat detector such as LHD cable or sprinkler indication. Smoke detector EVC-PY-DA The Consilium EVC-PY-DA with contamination supervision is an intelligent conventional smoke detector with a monitoring circuit that continuously checks and adjusts the sensitivity for optimum functionality during the entire life of the detector. When the detector no longer can compensate for the contamination, a service alarm is generated. Input/output interface loop unit CS-IC22 Manual call point CS-MCP The CS-IC22 is an input and output unit for various integration of safety I/O. It has been designed for use in damp spaces. This unit allows the connection of different types of devices with closing digital function to the fire alarm system, for example high temperature heat detector such as LHD cable or sprinkler indication as well as controlled safety relays for external control. The CS-IC22 is designed to control and monitor external devices, such as fire doors, fire dampers, sprinklers, hatches etc. The unit also gives support for fire, fault and disablements on individual level. The CS-MCP is a manual call point existing in different models to fit the specific environment. The unit provides the required system functionality for passenger activated emergency alert. A LED on the front of the call point indicates the fire alarm being activated. Line heat detector cable (LHD) Steel conductors Protective tape Outer jacket Heat sensitive polymer Consilium s line heat detector cable detects heat conditions anywhere along its length. The cable is available in a range of alarm temperatures and is suitable for a fire detection in areas such as traction units, electrical cabinets etc. 10 11

Aspiration detectors Modules Universal detectors Address units Displays Cables Fire extinguishing aerosols 12 13

ACCESSORIES Apart from the fire protection system there are different accessories required in order to support the required functions or to protect the products. Sounder beacon EMC cage EMC-1 The sounder beacon is a compact combination of a high output sounder and flash for areas requiring both audible and visual indication of alarms. The unit will sound and flash at the same time at activation. The sounder can be set to different sounds and has a built in volume control. The EMC-1 EMC Cage protects the detector from extreme electromagnetic fields and is necessary in environments with significant electrical interference, being out of range specified in standards. The EMC cage also protects the detector from damage such as vandalism. Sounder Protection cage DPC-1 The sounder is a compact high output sounder. The sounder can be set to different sounds and has a built in volume control. Consilium s protection cage DPC-1 is used to protect detectors from being damaged in rough environments or in areas where vandalism may occur. Sounder SUM-3 The sounder SUM-3 is a small buzzer with a sound pressure of 80 db(a) which easily snaps on to the detector base plate. The sounder is activated automatically on fire detection but can also be controlled independently from the control unit. It can be used in sleeping cabins or in other areas where a sounder is needed. Dust filter The Consilium dust filter is developed to protect detectors situated in extremely rough and dusty areas and environments. The filter prolongs the life-time of the detector and reduces the risk of false alarms due to contamination. The filter is attached to the detector by simple means and can easily be replaced when needed. 14 15

LASER ASPIRATION DETECTOR INTEGRATED SUPPRESSION AND FIRE FIGHTING The Consilium LASP detectors are a very early warning smoke detectors. The LASP provide the earliest warning of a potential fire and buys the user time to investigate, intervene and potentially avoid disruption in addition to the damage, downtime and cost of a suppression release. Consilium offers two models: LASP-250 works in areas with up to 25 m of aspiration pipe. LASP-500 works in areas with up to 50 m of aspiration pipe. The detector works by continually drawing air into sampling holes in a pipe network. The air is filtered and passed into a detection chamber where light scattering technology detects the presence of very small amounts of smoke. Detector status information is communicated on the detector display and via relays. The LASP systems can be installed and used together with other type of Consilium detectors to give full protection of a train. The ultrasonic flow sensing used in the detector provides a direct reading of the sampling pipe flow rate. The high pressure water mist system controls, suppress and extinguishes fires by discharging a fine water mist at high velocity. The water mist is created by the system when it activates: it pushes the plain, potable water at high pressure through specially designed, patented sprinklers and spray heads. The water mist is discharged at high velocity by high-pressure pumps or accumulators. Water mist uses three mechanisms to fight fire: cooling, radiant heat blocking and local oxygen inerting. Traditional sprinkler systems use wetting as their main mechanism, and therefore use very large amounts of water. A high pressure solution uses water much more efficiently: it uses up to 90% less water than traditional sprinkler systems for the same application with equivalent or better performance. Consilium can support a safe activation of the water mist system. FIRE EXTINGUISHING AEROSOLS Extinguishing principle When activated, the aerosol fire extinguisher sets off a chemical reaction whereby, nitrogen, water and potassium connections are build. The aerosol released from the extinguisher fights and extinguishes fire not by suffocation (depletion of oxygen) nor by cooling, but by stopping the chemical combustionreaction at molecular level (by binding free radicals) without depleting the oxygen content. Benefits of aerosols More efficient than all other conventional agents The extinguishing agent is in non-pressurized, stainless steel containers The extinguishing agent is environmental friendly The extinguishing agent is non-corrosive; it does not damage other objects Not harmful for people, animals or plants They require a negligible level of maintenance compared to any other conventional systems Electrical wires Outer liner Solid bound compound Isolation layer Oxidation layer Inner liner Cooling layer Discharge orifice Extinguishing aerosol The water unit can be placed either on the roof or underneath the car. 16 17

FIRE PROTECTION EXAMPLES Example 2 - Redundancy Block diagram The block diagrams show different kinds of configuration examples, describing a train set with four cars. Each car is equipped with smoke/heat detectors and distributed I/O units in typical installations. Central unit CM-2,2 is used in all examples but CM-4,3 can of course be used in the same way or in combination. Communication with the train control and monitoring system can be done over RS485, RS422, digital I/O or Ethernet in all examples. The setups below are just examples as the concept promotes customer specified system design. The modules can be used in several other ways to control and monitor other systems onboard. The back bone bus is used for communication between modules and stretched central segments. It includes redundant RS485 channels, redundant 24 VDC power line and the X-Fire signal. X-Fire is a signal in the back bone bus used for transmitting the central alarm status. The signal is only used when a module in a managed mode losses communication with its control unit. This signal is used to ensure that the fire detection system can deliver an alarm signal even if the system processor is down. Please note that all our applications are SIL 2 compliant. The redundancy system contains of two central units sharing one common loop. Both central units are activated, sharing information. If one central unit is lost, the other will take over the whole system. Therefore no information will be lost, meeting the requirements for running capability. This system configuration requires the use of our internal serial bus for internal communication. Example 1 - Standard Example 3 - Stretched system The first example shows a system solution with one central unit in the complete train set located in the driving car where the TCMS is located. A closed loop (return loop) ensures that all detectors can be accessed even if one connector between the cars has been damaged. This set up takes advantage of our internal serial bus, enabling stretching the system through the train and use communication modules locally in each car. In the example one I/O 700 module is used. These modules are used to control and monitor external functions such as fire doors, exit lights, extinguishing systems, shut down HVAC system etc. 18 19

Example 4 - Flexible system Example 6 - Independent suppression system Each car has its own independent fire detection system and communicates with the TCMS directly. If one control unit is lost in one of the cars, the other central units will take over the loop communication in the car and start reporting to the TCMS. This setup requires our internal serial bus between our controllers. Each car has its own independent fire detection and extinguishing system. Each central unit communicates with the TCMS directly. In case of fire, the control unit will by intelligent decision activate the extinguishing system. The system can be activated in different zones or in the complete car depending on the fire. The system will also monitor the status of water, gas, pressure etc. Example 5- Multi system Example 7 - Centralized suppression system Each car has its own independent fire detection system and communicates with the TCMS directly or via the master central unit. This configuration is preferred in an existing TCP/ IP network to reduce cabling. This shows a redundancy with an extra I/O 700 module to control a centralized extinguishing system. In case of fire the control unit will by intelligent decision activate the extinguishing system. The system can be activated in different zones or in the complete car depending on the fire. The system will also monitor the status of water, gas, pressure etc. 20 21

Example 8 - Laser aspiration system This shows a standard system with a local laser aspiration detectors in each car. The laser aspiration detectors provide a very early warning of potential fire and buy the user time to investigate, intervene and potentially minimize damage and downtime. The local laser aspiration detectors communicate via the IC44 address unit on the closed detector loop. Example 9 - Redundant sub loop system This shows redundancy with a local I/O on the redundant detection loop. With the local I/O on the sub loop is possible to control and monitor external functions such as fire doors, exit lights, extinguishing systems, shut down HVAC system. etc. 22 23

GO TOGETHER WITH CONSILIUM Our fire detection and protection systems give the train industry around the world the confidence for safer journeys every day. In fact, Consilium today protects over 16 000 train cars all over the world. As your partner, we offer our long experience, in-depth knowledge and global support network to you whenever and wherever you need it. Consilium Marine & Safety AB Transport Safety Division P.O. Box 8763 SE-402 76 Gothenburg, Sweden +46 (0)31-710 77 00 sales.transport@consilium.se www.consilium.se B004.1602.6