Astro Express 2 - Hot Water Delivery System

Similar documents
ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM

ASTRO 2 SERIES HOT WATER RE-CIRCULATION SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

ASTRO 2 SERIES HOT WATER RE-CIRCULATION SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

Installation and operating instructions. E.2 Series high efficiency circulator

E.2 series high efficiency circulator. Installation and operating instructions

Astro 2 circulator models. Installation and operating instructions

instant hot water no waiting & no waste benefits Hot water recirculation solutions Astro hwr

dualarm Vertical In-Line Pumps

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

569, 570, 571, 572 Series

569, 570, 571, 572 Series

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

Installation and Operating Instructions

INSTANT HOT WATER RECIRCULATING SYSTEM

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

SCHWAN INSTALLATION GUIDE

Installation Instructions

Installation Instructions

Autocirc Instant Hot Water Pump Model: ACT E10 INSTRUCTION MANUAL REVISION A

Installation Instructions

Comfort Series Instant Hot Water System

INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL A REVISION A. Series e 3-4/e 3-6 Instant Hot Water Recirculating Systems

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Installation & Operating Guide

Refrigerator. Installation Guide. Free Standing Appliance

Clean & Clear. Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Installation Instructions

MODEL 6430T, 6460 & 6460T POTATO PEELER

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

568X, 587X, 588X Series

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

INSTANT HOT WATER DISPENSER

Installation Instructions 30 French Door Built-in Wall Ovens

INSTALLATION, OPERATION & MAINTENANCE MANUAL BERG TEMPERATURE CONTROL UNIT

SuperKlean Washdown Products

Two Tier Illumifalls Patio Pond

Plumbing. ECM High-Efficiency Hot Water Recirculation System. Instant hot water for existing plumbing systems; no dedicated return line needed

Chilipepper CP9000. Installation Instructions READ BEFORE INSTALLING:

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Installation Instructions

489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

! WARNING. Before using product, read and understand instructions.

INSTALLATION INSTRUCTIONS

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

en-us Use and Care Manual, Installation Instructions Washer WAT28400UC

Installation Instructions

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS

Dishwasher. Installation manual DW60M9990AP

Dishwasher Installation Manual

Installation & Operating Guide

SCHWAN INSTALLATION GUIDE

Seal-less Centrifugal Canned Motor Pumps For Instant Hot Water Recirculating Systems

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

Important Safeguards (For your safety, please follow the instructions below.) Specification. Warning. Thermal mixing valve faucet.

Floating Pond Pump System 1/2, 3/4 & 1 HP 230V Models FPS05021, FPS07021, FPS10021

360 Series Waste & Overflow System. Installation Manual and User Guide

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 1000-P FAN SERIES (PNEUMATIC CONTROL) SERIES 1000-H FAN SERIES (HYDRAULIC CONTROL) GEN 2

16 OUTDOOR MISTING FAN

! WARNING. Before using product, read and understand instructions.

Installation Manual PS-225 & PS-275

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

Instructions. Certifications Chrome 2-handle Chrome 3-handle 10-B83-WCH-AD Chrome 3-handle 10-B82-WCH-AD Chrome 2-handle

FSW300 Series Flow Switch

OWNERS GUIDE TO INSTALLATION AND OPERATION

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL

MILLA ELECTRIC FIREPLACE

Water Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

Installation Instructions Air Pump

Installation Instructions

QuickStat-TC Installation & Operation Manual

Installation Instructions

Installation & Operation

Installation and Operating Instructions

Installation Manual PS-200 & PS-201

SS1095 Ice Maker.

Food Waste Disposer Instruction Manual

LC Series - Light Commercial Pump Station Installation and Operation Manual

Instruction Manual. Bell & Gossett ecocirc wireless Potable Hot Water Recirculation Kit

PENGUIN SERIES HSC PUMPS INTRODUCTION

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

Nilfisk Model VHS255 Drum Top Vacuum

T874 Multistage Thermostat and Q674 Subbase

Autotrol Performa FA Valve

Important Safeguards (For your safety, please follow the instructions below.) Specification. Warning. Thermal mixing valve faucet.

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Transcription:

FILE NO.: 10.817 DATE: Apr. 4, 2011 SUPERSEDES: 10.817 DATE: Feb. 24, 2010 INSTALLATION AND OPERATING INSTRUCTIONS Astro Express 2 - Hot Water Delivery System TYPICAL APPLICATIONS The Armstrong Astro Express 2 hot water delivery system ensures that users have hot water at the tap when you need it, while helping to conserve water. It s easy to install, and does not require special return piping to the water heater. Equipped with a high performance circulator and adjustable flowrate injection valve, the Astro Express 2 system is a one-size-fits-all solution for virtually any residential installation. The Astro Express 2 is the ideal solution for existing home retrofit where recirculation system return line installation is impractical, or new home construction where dedicated hot water return line installation is cost prohibitive. HOW IT WORKS Armstrong Astro Express 2 hot water delivery systems consist of a circulator for water heater mounting, and a valve for under-sink mounting. In operation, the timer activated circulator creates differential pressure across the Astro Express LF valve. When the water at the hot water faucet cools below the Astro Express LF valve low temperature setpoint, the valve opens, allowing the cooled water to be injected into the cold water line. When the water reaches the valve high temperature setpoint, the valve closes. The valve is equipped with a pressure independent flowrate adjustment to maintain the desired temperature balance. Additionally, the valve is equipped with a check valve to prevent cold water backflow when the hot water faucet is opened. INSTALLATION WARNING: Installation should only be completed by qualified personnel, in accordance with all applicable codes, and following generally accepted installation practices. Ensure the hot and cold water supply is turned off before installation, to avoid personal injury or damage to property. Read and understand these instructions thoroughly before beginning the installation. CAUTION: Prior to installation flush all piping of any foreign material to prevent pump blockage and prevent damage. Page 1 of 5

PROCEDURE 1. Timer installation and wiring. WARNING: Electrical shock hazard - Verify that the electrical rating of the device matches the values shown on the nameplate of the circulator. All electrical work should be performed by a qualified electrician in accordance with the latest edition of the National Electric Code, local codes and regulations. Failure to follow these instructions could result in serious injury, death and/or property damage. Note: Numerical component designations included in Steps a through j refer to circulator and timer components shown in Fig. 1. a. Unfasten the mounting screw (4A) and remove the terminal box cover (3). b. Unfasten the mounting screw (4B) on the timer box cover (10) and detach it from the base (8). c. Remove the original conductor (7A) from the circulator terminal box (2) d. Fasten the connection adaptor (7B) to the circulator terminal box (2) e. Fasten the threaded fitting (6) to the connection adaptor (7B) f. Fasten the lock nut (5A) on the end of the threaded fitting (6) and insert the timer box (8) g. Fasten the lock nut (5B) onto the end of the threaded fitting (6) so the timer box (8) is in between and securely attached. h. Connect timer lead wires (black, white and green) to the terminal box (as shown in Fig. 2). i. Re-attach the timer box cover (10) using the mounting screw (4B). Insure that all lead wires are inside the timer assembly. j. Close the terminal box cover (3) by fastening the mounting screw (4A). TIMER Green Ground Screw in timer box GREEN GREEN G Fig. 1 Astro 2 Series circulator and 24-Hour Timer assembly drawing Fig. 2 Astro 2 Series circulator and 24-Hour Timer wiring diagram 2. To mount the Astro Express 2 circulator: a) Turn off water supply. (If necessary, drain the hot water distribution pipes and partially empty the water heater.) b) Disconnect the hot water distribution pipe from the water heater outlet. c) Connect the Astro Express 2 circulator inlet to the water heater outlet nipple. d) Connect the distribution pipe to the circulator outlet. Page 2 of 5

3. Ensure the following conditions are met: a) The circulator shaft is horizontal. b) The clock/timer face is accessible for viewing and adjustment. c) The direction of water flow matches the arrow on the circulator casing. d) The piping is sufficiently rigid to support the system in operation. e) Neither the clock/timer nor black terminal box is under the circulator. 4. If the arrow on the circulator casing is not pointing away from the hot water heater, see ROTATING THE CIRCULATOR CASING. 5. To mount the Astro Express LF valve: a) Select the faucet to be controlled, typically the furthest faucet from the hot water heater. (For multi-branch hot water piping runs, a valve may be required at the end of each branch for maximum effectiveness.) b) Disconnect the hot and cold supply pipes from the faucet. c) Connect the hot and cold water supply to the Astro Express LF valve 1/2" threaded inlets. (Stainless steel flex hose recommended.) d) Connect the hot and cold Astro Express LF valve 3/8" threaded outlets to the faucet. (Stainless steel flex hose recommended.) e) Secure the valve to the wall under the sink, using the plastic wall anchor and screw. 6. Check the installation for leaks: a) Ensure the faucet is closed. b) Turn on the water supply. c) Open the hot and cold water supply valves. d) Open the faucet hot and cold taps to purge all air from the system. Close the faucet. e) Inspect the circulator and valve connections for leakage. If a leak exists, close hot and cold supply valves until leaks are corrected. 7. To connect power to the circulator: a) Verify that the timer s manual over-ride switch is in the OFF position. b) Plug the power cord into a standard 115 Vac household electrical receptacle. c) To perform and initial system test, see OPERATION. ROTATING THE CIRCULATOR CASING Prior to connecting the system to the hot water piping, if alternate orientation of either the circulator discharge or clock timer is required, proceed as follows: 1. Remove the four hex socket head screws that hold the casing to the circulator. 2. Gently pull the casing from the circulator body, taking care not to damage the gasket or impeller. 3. Rotate the casing as required to meet circulator discharge and clock timer orientation requirements. 4. Tighten the four hex socket head screws evenly; ensuring the gasket seals the mating surfaces. 5. To verify the circulator shaft still spins freely: a) Remove the plug from the end of circulator with a slotted screwdriver. b) Insert the screwdriver in the slot in the end of the shaft. c) Ensure the shaft turns freely and smoothly in both directions. d) Replace the plug and gently tighten. Page 3 of 5

OPERATION CAUTION: Never operate the system dry or permanent damage may occur to the circulator. Never shut off the water supply or restrict flow in any way while the circulator is operating. 1. Verify water is present at the circulator. 2. Verify the power cord is plugged into an appropriate household electrical receptacle. 3. To continuously run the circulator or test for initial operation, set the manual override switch to the ON position and verify the circulator operates smoothly and quietly. 4. To prevent circulator operation, such as for extended periods that the residence will be vacated, set the manual over ride switch to the OFF position. 5. For normal automatic operation, set the clock/timer as required and move the manual override switch to the AUTO position. SETTING THE CLOCK/TIMER 1. Rotate the dial in a clockwise direction until both the time shown, and the appropriate AM or PM indicator, correspond to the current time of day. (This adjustment is required for initial operation, following a power interruption, to adjust for daylight savings time, or for periodic time correction.) 2. Remove the clear plastic cover from the dial. 3. The outer ring of the dial has an adjustable tab for each 15 minute time interval of a 24 hour day. To enable circulator operation for a specific time interval, slide the corresponding interval tab to the outer position. All tabs positioned toward the center of the dial disable circulator operation for those time intervals. 4. Verify the manual override switch is in the AUTO position. 5. Replace the clear plastic cover on the dial. For maximum energy savings, set the timer to: a) Activate the circulator at least ½ hour before initial hot water demand for the day is anticipated. b) Deactivate the circulator when the anticipated hot water demand for the day ends. SETTING THE VALVE The Astro Express LF valve is factory set to suit most applications. The valve may be easily adjusted to suit application conditions and personal preferences. Switch Positions ON AUTO OFF Current Time Interval Tabs (15 minutes each) Dial AM/PM Indicators Flowrate Adjustment Screw 1. To increase the water temperature at the hot-water tap, turn the flowrate adjustment counter clock-wise one or two increments. 2. To decrease the water temperature at the cold-water tap, turn the flowrate adjustment clock-wise one or two increments. 3. To completely stop flow through the valve, turn the valve completely closed by turning the flowrate adjustment fully clockwise. If necessary to achieve the desired water temperature control, set the circulator timer to cycle the circulator on/off during the anticipated hot water demand period, in combination with valve adjustment. Allow ample time (at least several hours) after valve or timer adjustment, for the system temperature to stabilize, prior to evaluating the result of the adjustment. Page 4 of 5

TECHNICAL DATA ASTRO EXPRESS 2 CIRCULATOR Astro 220SSU Max. Power Consumption 43W, 0.36A Max. Head 4.5 ft (1.4 m) Max. Flow 9.5 GPM (0.60 L/s) Default Operating Speed Speed 3 Power Requirements 120 Vac, 60 Hz Power Connection 5.0 ft (1.5 m) power cord, molded duplex plug with ground Environment Indoor use only Max. Working Pressure 150 psi (1034 kpa) Ambient Temperature 39 F (4 C) to 104 F (40 ) Max. Water Temperature 230 F (110 C) Clock Timer 12-hour analog clock with AM/PM indication Timer Settings Individual toggles for each 15 minute interval over 24 hours 3 position slide switch, on/off/auto Pump Casing Stainless steel with 1-1/4" NPSM union threads Impeller Polyether Imide (PEI) Shaft Ceramic Bearings / Seal Ceramic Union Tailpieces Brass, 3/4" FPT (two) and 3/4" MPT (one) Union Gaskets EPDM (two) Approvals listed ASTRO EXPRESS LF VALVE Housing Internal Components Connections Environment Flowrate Adjustment Max. Working Pressure Max. Water Temperature Mounting Forged Eco brass* with Noryl cap Stainless steel and plastic with EPDM o-rings Threaded, 1/2" hot & cold inlets, 3/8" hot & cold outlets Indoor use only 0 100%, multi-turn slotted screw 100 psi (689 kpa) 140 F (60 C) Plastic wall anchor with screw *Complies with section 116875 at the California Health and Safety Code and Vermont Act 193 (Lead content of wetted surface is 0.25% or less.) REPLACEMENT PARTS PART DESCRIPTION ITEM NUMBER Part Description Item Number Astro 220SSU-T 110223-244 3/4" FPT Union Lead Free* Hardware Kit 810120-324 3/4" MPT Union Lead Free* Tailpiece 810120-346 24-hour Timer 810123-130 Timer Cover 110123-031 Astro Express LF Valve 561100 LF-001 S. A. Armstrong Limited Armstrong Pumps Inc. Armstrong Holden Brooke Pullen 23 Bertrand Avenue 93 East Avenue Wenlock Way Toronto, Ontario North Tonawanda, New York Manchester Canada, M1L 2P3 U.S.A. 14120-6594 United Kingdom, M12 5JL T: 416-755-2291 T: 716-693-8813 T: +44 (0) 161 223 2223 F: 416-759-9101 F: 716-693-8970 F: +44 (0) 161 220 9660 S.A. Armstrong Limited 2011 For Armstrong locations worldwide, please visit www.armstrongintegrated.com Page 5 of 5