Customized, End-to-End Facility Monitoring

Similar documents
Intelligent alarm management

Compact Product Suite Compact HMI 6.0 Overview ABB

ABB Ability System 800xA Alarm Management

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

Getting Started with Live Exceptions

Architectural and Engineering Specification for a Security Management System. StarNet 2

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

ONYXWORKS AND FIRSTVISION. Version 4

Monitor Alarms and Events

Monitor Alarms and Events

DeltaV Operate. Product Data Sheet DeltaV Operate December 2006 Page 1. Introduction. Benefits

Making the Most of Alarms

D-Link Central Management System

DeltaV Live. Introduction. Benefits. Modern, built-for-purpose operations experience

EnergyMaster. ENEC Monitoring System. An on-site supervision and remote monitoring solution

ALCATEL-LUCENT OPENTOUCH NOTIFICATION SERVICE IMPROVE REAL-TIME SITUATIONAL AWARENESS AND PERSONAL SAFETY

ALERiTY. Mass notification. Integrated IP-based network solutions

Avigilon Control Center 5 System Integration Guide

Software Solutions FOR THE TELECOMMUNICATIONS INDUSTRY CTS ALARM SOLUTION

DeltaV Operate. DeltaV Operate. Introduction. DeltaV Product Data Sheet. Robust and secure plant operations

Facility Commander Complete, Integrated Command and Control

A new view on building protection. Cerberus DMS makes building protection smarter, easier and more flexible. Answers for infrastructure.

Remote fiber testing to improve SLA s

Product Brief for Alarm Analytics V9.3 October 2013

Increase your awareness with

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

Oracle Communications Performance Intelligence Center

Driving simplicity. Facility and security management in a single interface

CAN unit for Analog Sensors

GMS GRAPHICAL MANAGEMENT SYSTEM

Effective Alarm Management for Dynamic and Vessel Control Systems

Ovation Alarm Management System

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

Simplex Panel Interface Guide

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

Welcome to a world where technology flows through the heart of your business environment. Welcome to CDC

P2000 and Metasys System Integration

LYNX CE CENTRAL CONTROL FOR OSMAC. General Specifications

Building Technologies

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

Vykon. Security. Integrated Access Control. Web enabled security management built on the Niagara Framework

I/A Series A 2 Software FoxAlert Alarm Manager

Managing Network Alarms and Events

2015 Honeywell Users Group Europe, Middle East and Africa. Incident Response at your Fingertips Adrian Fielding, Honeywell

Redefining Security for the Modern Facility

Application of OPC in the Intelligent Building System Integration

1 Introduction Data transmission Compatibility IPS Analytics configuration... 3

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

Remote / Network Control for Rack Cabinet Access - DL Series

Complexity made simple

Compact HMI Overview

AmpLight Lighting Management System

WHITE PAPER FEBRUARY Oracle Retail: Optimize Performance and Reduce Business Risk

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0

Exaquantum/ARA Alarm Reporting and Analysis

Product Brief for Alarm Analytics V9.2 April 2010

Software Solutions FOR THE TELECOMMUNICATIONS INDUSTRY CTS ALARM SOLUTION

Avigilon Control Center System Integration Guide

Innovative Security Solutions That Increase Force Protection Effectiveness

Surveillance Solution

Milestone XProtect Alarm Matrix Integration 1.0

Organize your security with PSIM + software

Universal Monitoring System. TrapServer Description

For Complete Fire and Gas Solutions

University. NewVoice. San Francisco Paris Geneva Zurich Linz Mainz Shanghai Brisbane Hong Kong São Paulo Dubai

GasGard 100 Control System

Setting up and Managing Alarms in McAfee ESM 10.x

Perimeter Product Overview. Effective protection for your business

Continuous, real-time detection, alarming and analysis of partial discharge events

Datasheet Crowd Management

TPS Virtualization and Future Virtual Developments Paul Hodge, Honeywell

Chapter. Configuring NICE NiceVision. Version build 10. Configuring Third-Party Programs. SightLogix, Inc

Raytec Avigilon Integration User Guide Integrating Raytec Network Illuminators with Avigilon Control Center Document Revision 2.0

System Galaxy Quick Guide

Using ANM Mobile CHAPTER

Organize your security with PSIM + software

Options Specification

Facility Commander Wnx

Notice... 1 Trademarks... 1 US Patent Numbers... 1 Technical Services Contact Information... 2 Document Conventions... 2 Warranty...

Am I safe working in this building?

Batt-Safe Battery String Monitoring System

COMMERCIAL BUILDING SOLUTION

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Ademco Vista Alarm Panel

Andover ContinuumTM. SNMP Alarming

ARCHITECTURAL AND ENGINEERING SPECIFICATION

Itron Water Loss Management Solutions. Advanced Digital Leak Detection Overview Session

Rosenberger Intergrated Operation and Maintenance Center for all repeaters(2g/3g/lte) following CMCC and TMN specification.

DeltaV Analyze. Introduction. Benefits. Continuous automated DeltaV System alarm system performance monitoring

Typical applications include the vibration detector. Detection of vibrations and shocks

LYNX SE CENTRAL CONTROL FOR NETWORK GDC. General Specifications

How the People Counter Works. Enhanced Safety, Security and Building Automation, and Improved Marketing Intelligence. 3D MLI Sensor Technology

PotterNet Fire & Facility Supervising Station

Table of Contents. i-vu CCN Standard 4.2

ASCO PowerQuest Critical Power Management System

Web Services are based on Apache and Tomcat servers. The html/jsp (tags, beans) are fully customisable and extendable.

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

Getting Started with SPECTRUM for Operators

LightSweep. Lighting Control System

Transcription:

Datasheet icontrol Customized, End-to-End Facility Monitoring Stay in control with customizable monitoring and interfaces. A highly adaptable television signal and network monitoring system, icontrol from Grass Valley, a Belden Brand, is compatible with multiple advanced electronic supervision technologies, including Monitoring by Exception. It offers electronic probing with macroblock detection, lip sync error and content mismatch detection using video/audio fingerprints. Leveraging SNMP and monitoring rich visual and acoustic monitoring, it enables highly customized monitoring and control systems for broadcasters and pay TV operators, including advanced, end-to-end Network Management Systems. Intelligent Alarm Management icontrol s Advanced Alarm Management enables operators to work together to identify and resolve facility faults to minimize the MTTR. icontrol offers Advanced Alarm Management to help operators deal effectively with the large volumes of alarms that can be generated in large facilities. Multiple users can work together in a co-ordinated manner to troubleshoot complex networks and multiple alarms. Operators have access to more than just the overall status of their television facilities. Individual signals and device status can be isolated, including detailed video and audio parameters, router crosspoints, GPI contact closure and SNMP-enabled third-party systems. Each element can be monitored separately, or in combination with others. Groups of alarms and events can be managed as incidents, with related events automatically correlated and grouped under a single umbrella. For instance, a typical signal fault on an upstream satellite receiver will impact all downstream devices on the same signal path. However, rather than dealing with multiple alarms, such as IRD errors, video proc-amp errors, audio processor errors and signal probe errors, the operator can now respond and analyze the fault as a single entry in the Incident Manager. Automated and Guided Response to Alarms icontrol s auto-pilot capability provides automatic reaction to alarms, and can also guide an operator through complex diagnostics. It s based on Scripted Macros which can be easily created to control specific automated responses. For instance, in the event of failure of the transmission stream, a backup signal path can be instantly brought into effect. This minimizes disruption while essential maintenance work is undertaken. Broadcast Facility Monitoring with icontrol The Grass Valley, a Belden Brand, icontrol system is ideal for monitoring broadcast facilities, including highly distributed multichannel operations. With its rich graphical interface, third-party control integration, and automated responses, the system enables operators to control multiple channels in a highly effective manner. Customized Views with icontrol Monitoring of multiple signals across multiple locations is more effective using icontrol. With icontrol, monitoring of multiple signals is easier. Users have the ability to create custom views of complex video networks, allowing operators to easily perform the following tasks: Recognize the status of multiple signals and devices Understand the consequences of a fault React rapidly if their intervention is required Access to either summary information or detailed levels is quick and efficient. Operators can click on key areas of icontrol pages to drill-down to more detailed views of the network topology. icontrol can be used to create custom views of: A national or regional network with interactive geographical map views Summary views of multiple signals inside a station or facility Signal flow diagrams, depicting the detailed status of channels as they get processed and distributed across multiple devices Detailed schematics representing the interconnection of signal acquisition, processing, routing and transmission Physical views of equipment, such as rack elevations, representing the status of Grass Valley and SNMPenabled third-party devices 1

icontrol Customized, End-to-End Facility Monitoring Intelligent alarm management icontrol Web s Advanced Alarm Management enables operators to work together to identify and resolve facility faults to minimize the MTTR. icontrol Web offers Advanced Alarm Management to help operators deal effectively with the large volumes of alarms that can be generated in large facilities. Multiple users can work together in a co-ordinated manner to troubleshoot complex networks and multiple alarms. Operators have access to more than just the overall status of their television facilities. Individual signals and device status can be isolated, including detailed video and audio parameters, router crosspoints, GPI contact closure and SNMP-enabled third-party systems. Each element can be monitored separately, or in combination with others. Groups of alarms and events can be managed as incidents, with related events automatically correlated and grouped under a single umbrella. For instance, a typical signal fault on an upstream satellite receiver will impact all downstream devices on the same signal path. However, rather than dealing with multiple alarms, such as IRD errors, video proc-amp errors, audio processor errors and signal probe errors, the operator can now respond and analyze the fault as a single entry in the Incident Manager. Expanded alarm priority: minor, major and critical. Alarms can also be disabled based on user s operational role. Allows alarms to be scheduled, to prevent generation of unnecessary alerts Alarms can be scheduled as one-time events, or on a recurring mode Alarms can be manually snoozed for specific periods to time Status of a snoozed alarm will automatically revert to its normal status after the specified interval Log viewer displays clear and concise description of alarms Description now matches exactly with labels used in icontrol navigatior 2

KALEIDO-MX icontrol Customized, End-to-End Facility Monitoring Automated and guided response to alarms icontrol Web s auto-pilot capability provides automatic reaction to alarms, and can also guide an operator through complex diagnostics. It s based on Scripted Macros which can be easily created to control specific automated responses. For instance, in the event of failure of the transmission stream, a backup signal path can be instantly brought into effect. This minimizes disruption while essential maintenance work is undertaken. Automated response to alarms is provided by the scripted macros auto-pilot function Alarm generation icontrol SNMP Change multiviewer layout Control router Control signal processor SNMP SET/GET command or trap E-mail or GPI icontrol Web client software Programmable alarm reactions icontrol website Alarm Alarm filters (scheduled or slaved to automation) Alarm filtering Logical Logical Logical alarm profiling Dynamic alarm profiling 3

icontrol Customized, End-to-End Facility Monitoring Broadcast facility monitoring with icontrol The Grass Valley icontrol system is ideal for monitoring broadcast facilities, including highly distributed multichannel operations. With its rich graphical interface, third-party control integration, and automated responses, the system enables operators to control multiple channels in a highly effective manner. Multisite infrastructure monitoring End-to-end facility signal path monitoring Multiformat video monitoring Multichannel audio monitoring Internal signal validity and external status reporting Device alarm management Integrated Grass Valley and third-party control applications Feed quality control Network Operations Center monitoring with icontrol icontrol represents the most advanced, end-to-end facility monitoring for television service providers (cable/satellite/iptv). For large facilities, icontrol offers the ability to monitor thousands of devices effectively using customized, self-building facility views and intelligent alarm management. Operators can monitor a large number of television channels highly effectively using Monitoring by Exception to focus their attention, and achieve a rapid MTTR in the event of a failure in the facility. 4

icontrol Customized, End-to-End Facility Monitoring Customized views with icontrol Monitoring of multiple signals across multiple locations is more effective using icontrol With icontrol, monitoring of multiple signals is easier. Users have the ability to create custom views of complex video networks, allowing operators to easily perform the following tasks: Access to either summary information or detailed levels is quick and efficient. Operators can click on key areas of icontrol pages to drill-down to more detailed views of the network topology. Recognize the status of multiple signals and devices icontrol can be used to create custom views of: Understand the consequences of a fault A national or regional network with interactive geographical map views React rapidly if their intervention is required Summary views of multiple signals inside a station or facility Signal flow diagrams, depicting the detailed status of channels as they get processed and distributed across multiple devices Detailed schematics representing the interconnection of signal acquisition, processing, routing and transmission Physical views of equipment, such as rack elevations, representing the status of Grass Valley and SNMP-enabled third-party devices Pick and choose from the ever expanding library of widgets, which drag-and-drop to the user interface to create accurate depictions of a TV network icontrol Website Creator provides an extensive library of widgets to allow quick creation and editing of a high quality user interface. Widgets are available for all key devices and functions. Geographic View provides instant access to distributed television infrastructures Fort Myers Jacksonville Tallahassee Operators can easily monitor a station or network at an overview level, and then drill down through Geographical, Operational and Maintenance Views to reach the appropriate control level, and quickly respond to any error conditions. 5

icontrol Customized, End-to-End Facility Monitoring icontrol performance reporting and analysis with icontrol Report Signal and system performance reports for multichannel television systems icontrol keeps operators of multichannel television systems aware of channel performance over time. Providing a variety of powerful reports and using multiple forms of visual graphs, icontrol helps operators assess the performance of complex signal distribution networks by highlighting which channels perform best and which ones require their attention. For added convenience, icontrol performance reports can be embedded in icontrol s top quality user interface or be automatically e-mailed to selected recipients. KEY FEATURES Selectable video and audio and other quality metrics Users can easily define which criteria contribute to reports, allowing them to focus on the most relevant channel performance information Selection can be made among the wide list of video and audio metrics supported by icontrol, including video freeze, video black, audio loss and silence. Also supported are macro-block detection and lip sync errors, as well as transport stream and IP video errors With icontrol SNMP, performance reporting can be achieved on device and infrastructure performance Reporting on trends to help improve service quality icontrol performance reporting helps reduce the Mean Time to Repair by clearly distinguishing valid signals from the ones that continuously contribute to fault and invalid service quality Reports can focus on error counts or fault durations Charts can display trend over different time intervals: minutes, hours, days and weeks, etc. Performance ranking can be based on a selectable quantity of entries Helps operators focus on issues and trends before they become critical situations Advanced and flexible report generation and distribution Reports can be viewed in icontrol or can be forwarded via e-mail to user-defined lists of recipients Automatic report generation can be set for daily, weekly or monthly basis Comprehensive graphs using visual forms Direct access to charts from icontrol Navigator or icontrol Context specific report can be embedded directly in icontrol s powerful user interface Choice of bar, line, column, pie and other forms of charts for effective representation icontrol performance reports can be embedded directly in icontrol s rich, context-specific user interface Reports can summarize performance based on a wide range of metrics, using multiple forms of graphs for effective representation ORDERING IC-REPORT-001 icontrol Interactive Report Generator Includes data formatting, summarization and chart builder IC-BASE-EDITION-V3 icontrol Base Edition including: 1 RU Dell PowerEdge R330 application server, icontrol Navigator application, GSM alarm management service and Densité card management service IC-BASE-EDITION-ENT-V3 icontrol Base Edition including: 1 RU Enterprise-Grade Dell PowerEdge R330 application server with redundant power supplies and disk drive with RAID controller, icontrol Navigator application, GSM alarm management service and Densité card management service 6

icontrol Customized, End-to-End Facility Monitoring Network Operations Center Monitoring with icontrol icontrol represents the most advanced, end-to-end facility monitoring for television service providers (cable/satellite/iptv). For large facilities, icontrol offers the ability to monitor thousands of devices effectively using customized, self-building facility views and intelligent alarm management. Operators can monitor a large number of television channels highly effectively using Monitoring by Exception to focus their attention, and achieve a rapid MTTR in the event of a failure in the facility. icontrol Performance Reporting and Analysis with icontrol Report Signal and system performance reports for multichannel television systems The Grass Valley, a Belden Brand, icontrol keeps operators of multichannel television systems aware of channel performance over time. Providing a variety of powerful reports and using multiple forms of visual graphs, icontrol helps operators assess the performance of complex signal distribution networks by highlighting which channels perform best and which ones require their attention. For added convenience, icontrol performance reports can be embedded in icontrol s top quality user interface or be automatically e-mailed to selected recipients. Selectable video and audio and other quality metrics Users can easily define which criteria contribute to reports, allowing them to focus on the most relevant channel performance information Selection can be made among the wide list of video and audio metrics supported by icontrol, including video freeze, video black, audio loss and silence. Also supported are macro-block detection and lip sync errors, as well as transport stream and IP video errors With icontrol SNMP, performance reporting can be achieved on device and infrastructure performance Reporting on trends to help improve service quality icontrol performance reporting helps reduce the Mean Time to Repair by clearly distinguishing valid signals from the ones that continuously contribute to fault and invalid service quality Reports can focus on error counts or fault durations Charts can display trend over different time intervals: minutes, hours, days and weeks, etc. Performance ranking can be based on a selectable quantity of entries Helps operators focus on issues and trends before they become critical situations Advanced and flexible report generation and distribution Reports can be viewed in icontrol or can be forwarded via e-mail to userdefined lists of recipients Automatic report generation can be set for daily, weekly or monthly basis Comprehensive graphs using visual forms Direct access to charts from icontrol Navigator or icontrol Context specific report can be embedded directly in icontrol s powerful user interface Choice of bar, line, column, pie and other forms of charts for effective representation KEY FEATURES End-to-end monitoring icontrol is the most complete end-to-end, signal and facility monitoring system for broadcasters and television service providers All the elements involved in the production, processing and playout of television signals can be controlled from a single, integrated GUI Top quality user interface Highly graphical views, with full motion and high quality streaming video, allow operators to quickly identify and respond to alarms, and thereby reduce the Mean Time to Repair (MTTR) System is geared towards simplifying operations so that a single user can control more channels or a broader range of monitoring tasks Interface can be configured with multiple levels appropriate to different tasks: Geographic View provides multisite viewing Operational View offers a closer view of a facility Maintenance Views provide even closer device and signal level monitoring Full scalability Easily scales from small projects, with a few signals in a single room, to the largest systems with hundreds of services across multiple locations. Monitoring by Exception allows operators to focus their attention on television channels with alarm conditions, without distraction from correctly functioning channels SNMP monitoring plus embedded applications High level of control and monitoring of Grass Valley and third-party devices by combining SNMP control protocols with feedback from full motion and high-quality streaming video With its SNMP Manager functions, icontrol interfaces to all SNMPenabled devices, and users can establish their own SNMP interfaces A higher level of control of third-party devices is achieved by embedding their native applications in the GUI, and these can be automatically presented by device alarms to speed up response times Network Management System (NMS) By correlating information from multiple signals and systems, icontrol offers advanced alarm management which helps operators deal with the large volumes of alarms generated in large facilities Multiple events can be managed as a whole, with related alarms automatically grouped under a single umbrella Multiple users can work together in a coordinated manner to troubleshoot complex networks and multiple alarms Auto-pilot capability Auto-pilot capability, driven by Scripted Macros, can guide operators through complex diagnostics, and can provide automatic reaction to failures. For instance, in the event of a failure of the transmission stream, a backup signal path can be activated ORDERING IC-WEB icontrol Web software, (requires IC-BASE-Edition) Includes: ability to script autopilot functions, ability to embed third-party Windows IC-BASE-EDITION-V3 icontrol Base Edition including: 1 RU Dell PowerEdge R330 application server, icontrol Navigator application, GSM alarm management service and Densité card management service IC-BASE-EDITION-ENT-V3 icontrol Base Edition including: 1 RU Enterprise-Grade Dell Power- Edge R330 application server with redundant power supplies and disk drive with RAID controller, icontrol Navigator application, GSM alarm management service and Densité card management service IC-SNMP-MANAGER SNMP manager software IC-SNMP-DRIVER-CREATOR IC-ROUTER-CLIENT IC-REPORT-001 IC-FINGERPRINT Related Products RCP-200 EDGEVISION HCP-1801 HLP-1801 icontrol SNMP driver creator software icontrol router control software icontrol interactive report generator icontrol Fingerprint license for lip sync error and content mismatch detection Advanced remote control panel Edge signal monitoring device HD/SD-SDI digital video control probe with embedded audio 2 input HD/SD-SDI probe with fingerprint generation GVB-1-0058B-EN-DS WWW.GRASSVALLEY.COM Join the Conversation at GrassValleyLive on Facebook, Twitter, YouTube and Grass Valley - A Belden Brand on LinkedIn. Belden, Belden Sending All The Right Signals and the Belden logo are trademarks or registered trademarks of Belden Inc. or its affiliated companies in the United States and other jurisdictions. Grass Valley, Densité and icontrol are trademarks or registered trademarks of Grass Valley. Belden Inc., Grass Valley and other parties may also have trademark rights in other terms used herein. Copyright 2014, 2016 Grass Valley Canada. All rights reserved. Specifications subject to change without notice. 7