Promoting quality installation of central AC (and heat pump) systems

Similar documents
What you need to know about residential furnaces, air conditioners and heat pumps if you re NOT an HVAC professional

Minnesota Multifamily Rental Characterization Study

In accordance with the Department of Labor and Industry s statute , Subd. 11,

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

Duct Design and Installation

10/26/2016. Funding. Conservation Applied Research and Development Program (CARD)

Introduction. Motor Types

In accordance with the Department of Labor and Industry s statute , Subd. 11,

Ductless and ducted mini splits- with case studies. Heat Pump and Air Condi1oning For Energy Design Conference By Mike D. Wilson- Dakota Supply Group

In the past, contractors sized heating and cooling systems GETTING HVAC RIGHT

C mon in. Ways to save are waiting for you. otpco.com/sayhitosavings

ICP Inverter Heat Pump Application Guideline

ICP Inverter Air Conditioner Application Guideline

Building America AC Installation Using CheckMe!

Improving Air Handler Efficiency in Houses

Upgrade Your Comfort

Triple E New Construction. Doug Manthey Conservation Technologies Chad Trebilcock Minnesota Power

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

Energy Management Wiring Guide

Residential Water Heating

Troubleshooting the Indoor AHU as a Standard Product

Welcome. High Performance Mechanicals for Houses That Work. Energy Design Conference - Duluth, MN. February 21 st, 2018

97.501B. Prepared by: (415) Sponsored By: Final Report. Author: Presented at: ASHRAE. Meeting SF Me!

Pacific Gas and Electric Company

What Can 13,000 Air Conditioners Tell Us?

Product Rebates INDIANA

Special Topics on Residential HVAC

Product Rebates MICHIGAN

Field Application of Advanced Residential Air Conditioning Systems

Southwest Air Conditioning

Air-Conditioning Buying Guide

Energy-Efficiency Options for Residential Water Heating

ENERGY FIT HOMES. In accordance with the Department of Labor and Industry s statute , Subd. 11,

Prepared by: (415) Prepared for: Final Report May Contributors: Annn Edminster. Me!

Combined Space and Water Heating: Making it Work

99.503A. Prepared by: (415) Drains: Power. Prepared for: ACEE. Final Report Contributors: Danny Parkerr. Me!

PACIFIC HVAC Air conditioner. Authorized Daikin Split systems & VRV contractor. Tel:

GEOTHERMAL COMFORT SYSTEMS

Technical Standards for the Air Conditioning and Heat Pump Professional BPI STANDARDS

Why Doesn t My HVAC System Work?

Field Tests of Specially Selected Air Conditioners for Hot Dry Climates

ACCA Manual J Load Calculations

Capt. Tim s s Duct Design Mythbusters. The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

2016 BUILDING ENERGY EFFICIENCY STANDARDS RESIDENTIAL HVAC ALTERATIONS

F requently A sked Q uestions

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

5 Cool Tips for Getting the Right Air Conditioning System pg. 1

Data not Dogma. John Proctor July 30, 2014

EXHIBIT 1. Washington Home Energy Savings Program Measures, Incentives, and Qualifications

Geothermal. Comfort Systems

FirstEnergy Program Overview

Geothermal Comfort Systems

Smart vs. Proprietary Thermostat Webinar Which is best for your customers? Session #1 5/3/ am CST Session #2 5/11/ pm CST

SERVICE ASSISTANT OVERVIEW FDSI Online Training

For an administrative fee of $9.97, you can get an un-locked, printable version of this book.

Energy Efficient Options for Residential Water Heating

Application Guideline

Moisture, Ventilation & Global Weirding NEHERS Webinar Series

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631)

APS Cool Control Program

Reviewing HVAC Designs for Compliance with ACCA Manual S

AND WORRY-FREE PERFORMANCE

HEATING AND COOLING REBATES

HEATING AND COOLING REBATES

INTRODUCING YORK AFFINITY VARIABLE CAPACITY RESIDENTIAL SYSTEMS

HEATING AND COOLING REBATES

How Air Conditioners Work by Marshall Brain

Otherwise, you can continue reading the file on the following pages.

When Duct Sealing Kills HVAC Equipment and Efficiency

It pays to save energy. Guide to Xcel Energy rebates, incentives and programs for residential customers in Minnesota

The Housing Assistance Council is a national nonprofit organization that helps build homes and communities

Installation Instructions

IT S ABOUT TIME FOR FRESH AIR.

YORK AFFINITY VARIABLE CAPACITY RESIDENTIAL SYSTEMS

PR SERIES SELECTION AND OPTIMIZATION GUIDE

MANUAL J/S Summary One summary sheet for each system

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

Managing HVAC in High Performance Buildings

Geothermal Comfort Systems

HVAC for Raters & Inspectors

Determining Real Time Performance of Residential AC Systems. Presented at the RESNET Conference San Antonio, TX February 28, 2006

User s Information and Installation Instructions

COLEMAN ECHELON VARIABLE CAPACITY RESIDENTIAL SYSTEMS

Understanding Head Pressure Control. Walter H Langille, M.A.Sc., P.Eng Sales Engineer KeepRite Refrigeration

Passion & Innovation: The Enertech Team. Member

An Innovative Product s Path to Market. The influence of laboratory and field evaluations on adoption and implementation

UPGRADES. [Energy Efficiency] Base Points

May 13, 2015 VIA ELECTRONIC FILING

Xc21 air conditioner up to seer Xc21

TO THE FOR PRESCRIPTIVE COMPLIANCE OF FOR RESIDENTIAL ALTERATIONS

CHAMPION MOMENTUM VARIABLE CAPACITY RESIDENTIAL SYSTEMS

COLEMAN ECHELON VARIABLE CAPACITY RESIDENTIAL SYSTEMS

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Acca Residential Load Calculation Manual Also Called Manual J

Published by the California Building Performance Contractors Association

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com

DUCT LEAKAGE (Page 1 of 3)

PACKAGED DUAL FUEL UNIT ENERGY-EFFICIENT COMPRESSOR. UP TO 14.5 SEER, 8.0 HSPF, 81% AFUE Multi-Position Installation

DUCTLESS FULL LINE CATALOG

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Transcription:

Promoting quality installation of central AC (and heat pump) systems Energy Design Conference and Expo Duluth, MN February 26, 2014 and gas furnaces

In accordance with the Department of Labor and Industry s statute 326.0981, Subd. 11, This educational offering is recognized by the Minnesota Department of Labor and Industry as satisfying 1.5 hours of credit toward Building Officials and Residential Contractors continuing education requirements. For additional continuing education approvals, please see your credit tracking card.

Topics for today What do we know about the incidence and impacts of QI issues in the Midwest? What is the current landscape of utility programs addressing QI issues? What do we most need to learn to make programs better?

Central AC systems are not plug-and-play Size Refrigerant charge Airflow Controls Duct leakage

Sizing

What s out there (in WI)? 7% 3.5+ 1.5 6% 23% 3 tons 2 tons 40% 2.5 tons 24% Source: ECW Residential Characterization Study (1999)

other infiltration 2% 5% blower heat 8% ceilings 13% internal gains 14% walls 19% windows 39% Aggregate Manual-J estimated contribution to design cooling load for 37 homes in Madison, WI

What s often missing from Manual J calculations? Shading Lo-e windows Hidden insulation Thermostat setpoint Air leakage

After-the-fact Manual J Calculations for 37 WI homes Undersized by...1 ½ ton 1 3% 1 ton 3 8% ½ ton 9 24% Appropriately sized 13 35% 86% within ½ ton Oversized by... ½ ton 10 27% 1 ton 1 3% Total 37 100%

Hourly outdoor temperature (F) Operating minutes per hour What do run-time data say about sizing? 100 60 50 90 40 80 30 20 70 10 60 midnight 6 am noon 6 pm midnight 0 Site 1019 on July 17, 2005

Relative size (based on monitored operation) 250% oversized 200% oversized 150% oversized 100% oversized 50% oversized Appropriately sized 50% undersized 39 sites, sorted from lowest to highest

Cycling for some systems looks like this On Off 0 6 12 18 24 Hour of the day On and like this for others Off

Sizing Experiment Load calcs said: 1.5 tons needed New 3-ton unit installed in 2005 New 2-ton unit installed in 2006 (same make/model) Monitoring over both summers

Daily kwh No difference in energy consumption! 20 15 3-ton 2-ton 518 ± 56 kwh 522 ± 43 kwh 10 5 0 65 70 75 80 85 Daily average outdoor temperature (F)

Sizing bottom line (from WI research) Most systems are over-sized Think twice before installing anything over 2.5 tons Many homes would be fine w/ 1.5 tons But it s difficult to size accurately Proper sizing will not likely save much energy (unless you re WAY off) save some money on installed cost help avoid indoor hurricanes (if airflow is reduced) perhaps provide better humidity control

REFRIGERANT CHARGE

Expansion Device (Fixed or Thermostatic)

Refrigerant Charge Field Test

Efficiency relative to correct charge (%) ~10% significantly undercharged ~50% somewhat undercharged ~10% overcharged ~30% OK 100 80 60 Fixed orifice expansion device older units 40 Thermostatic expansion valve (TXV) newer units 20 undercharged overcharged -40-20 0 20 40 Charge error (%)

AIRFLOW

Three types of blower motors PSC (permanent magnet split capacitor) Low cost, lower efficiency, limited airflow range, doesn t maintain airflow ECM (electronically commutated motor) Higher cost, higher efficiency, large airflow range, maintains airflow Constant Torque (aka X13 ) Not as expensive as ECM ECM efficiency Capable of large airflow range, but limited selection (set by OEM) Maintains airflow better than PSC

ECM vs. PSC airflow Tested airflow range (cfm) 1600 1400 1200 1000 800 typical cooling mode airflow range for an ECM air handler 600 400 Typically ~525 Watts per 1,000 cfm Typically ~325 Watts per 1,000 cfm 200 Measured airflow range for some individual PSC air handlers

Airflow Cfm per ton 700 PSC ECM 600 Little air conditioner w/ big furnace 500 Big air conditioner w/ little furnace 400 300 200 70 sites, sorted from lowest to highest

% change in EER Measured EER impact of changing airflow +30 +20 +10 Improved efficiency 0-10 ECM air handler PSC air handler Reduced efficiency -300-200 -100 0 +100 Change in airflow (cfm per ton)

Airflow bottom line Check airflow Especially if small AC w/ large furnace Reduce airflow if possible (to a degree) Install an ECM furnace (or maybe X13)

Tuning overall results Type of adjustment Older systems (n=21) New SEER 10-13 systems (n=10) New SEER 14+ systems (n=30) All systems (n=61) Airflow 6 (28%) 0 (0%) 14 (47%) 24 (39%) Refrigerant 15 (71%) 7 (70%) 11 (37%) 33 (54%) Coil clean 8 (38%) 0 (0%) 0 (0%) 8 (13%) Filter replacement 1 (5%) 0 (0%) 3 (10%) 4 (7%) Mean % EER improvement 3.1 ± 6.1% 13.3 ± 20.9% 4.6 ± 3.9% 5.4 ± 4.1%

Site System Description % EER improvement Adjustments (key savings contributor underlined) 41 3-ton, non-txv, non-ecm, R-22, SEER 10 68% Corrected 88% undercharge. 65 2-ton, non-txv, non-ecm, R-22, SEER 13 55% Corrected 58% undercharge. 69 1.5-ton, non-txv, non-ecm, R-22, SEER 10 31% Corrected 33% undercharge. Reduced airflow 131 cfm for 245 watt reduction in air handler power. Cleaned condenser coil. 28 2.5-ton, non-txv, ECM, R-22, SEER 10 27% Cleaned condenser. Corrected 27% undercharge. Small airflow adjustment had negligible impact. 15 2-ton, TXV, non-ecm, R410a, SEER 14 26% Reduced airflow 320 cfm for 210 watt reduction in air handler power. 64 2.5-ton, non-txv, non-ecm, R-22, SEER 10 25% Corrected 18% undercharge. 63 3-ton, non-txv, non-ecm, R-22, SEER 14 25% Corrected 37% undercharge. 34 2-ton, TXV, ECM, R410a, SEER 14 18% Reduced airflow 195 cfm, for 240 watt reduction in air handler power. Correction of 4% overcharge also improved EER slightly.

CONTROLS

Two important controls Airflow setting for Fan-on operation ECM FAR superior if set correctly! Cooling-mode fan-off delay Don t use in humid climates!

How much water is in a houseful of summer indoor air? 75 o F 50% RH How much water is stored on a 2-ton coil when it is fully saturated? About ¼ to ½ gallon 1½ gallons add ½ gallon 75 o F 67% RH

Better humidity control associated with Hours of AC operation Better (smaller) sizing = more hours of AC operation = fewer hours of uncontrolled humidity Home tightness Tighter keeps the outdoors out Auto-Fan operation (not constant fan)

Condensing Gas furnaces Orifice size and gas manifold pressure Affects firing rate Airflow and temperature rise Controls

QUALITY INSTALLATION PROGRAMS

Minnesota QI/QM programs Existing unit tune-up Typically $25 incentive Must be licensed contractor, but not necessarily registered with utility QI for new standard-efficiency unit Typically $50 incentive Typically must be registered installer QI for new high-efficiency unit Higher incentives, depending on SEER/HSPF Typically must be registered installer

Minnesota QI/QM programs, cont. Existing system tuneup Offer QI for Std. eff. system? Xcel No Yes Yes Great River Co-ops Some Some Yes MN Power No Yes Yes Interstate No No No Ottertail No No No Require QI for high-eff system? Municipals Some Some Some

Utility Number of Registered Contractors Great River 1,142 Xcel 750 Minnesota Power 154

Other notable QI programs CheckMe (Proctor Engineering Group) CoolSaver (CLEAResult) HVAC SAVE (MEAA) http://www.slideshare.net/hardinet/tom-downey-nv-energy

Current research in MN (CARD project) Market research Interviews with distributors, contractors, utilities and others Homeowner survey Field research Field tests on 120 systems Run-time monitoring of 60 systems Synthesis What does this tell us? Two facilitated meetings of interested stakeholders

Programs should emphasize installation practices that have a high incidence of issues offer good savings from getting it right contractors are willing and able to implement

What do YOU think is important to learn from this research?

Thank you! Scott Pigg spigg@ecw.org 608-210-7138