SOLAR POWER PLANT AUTOMATIO

Similar documents
[ [ ADMIN PANEL USER GUIDE

Technical Manual

CITY OF WHITEHORSE SERVICING STANDARDS MANUAL SECTION 2 - CONSTRUCTION DESIGN CRITERIA SUB-SECTION 2.A SCADA STANDARDS.

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

Dr. Anton Poeltl, ABB PPHV, 5/19/2014 Condition Monitoring Approach Sensors, Methods, Data. ABB Month DD, YYYY Slide 1

Panel Mounted Fault Annunciator Series

Installer Certification Expiration. Terms

COMPANY PROFILE Electrical & Instrumentation Contractor

Intelligent alarm management

RAYCHEM NGC-30 COMPONENTS

RADIOLOGICAL SURVEILLANCE & ALARM MANAGEMENT SYSTEMS

Exaquantum/ARA Alarm Reporting and Analysis

Products and Portfolio 01 Relay Panels Control Panels Special Panels

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

Installation Summary - Dairy Plant

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Substation Monitoring System

Annunciator Unit SACO 16 D1. Product Guide

910 Series Single-point heat-tracing control system

CONTROL SYSTEMS Combustion Control Burner Management Control Balance of Plant Equipment Control Supervisory Control and Data Acquisition

Distribution Control Center Operator Training

For Complete Fire and Gas Solutions

Annunciator unit. Application

Contents. Preface. Chapter 2 Faults, types and effects The development of simple distribution systems Faults-types and their effects 7

1U ULTRA Compact System

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

Panel Mounted Fault Annunciator Series

Siemens Relay Ref Manual

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

GasGard 100 Control System

Automation Access Control

PROMATIC WDC Heating controllers Energy under control

ADAC. Advanced Deaerator Control

Compact Product Suite Compact HMI 6.0 Overview ABB

Analog Annunciator Unit SACO 16 A3. Product Guide

Schneider Electric solutions for the PV market. Denis Koch Strategy Director / Renewables January 2011

EE034: Electrical Maintenance for Engineers & Technicians

Batt-Safe Battery String Monitoring System

EZT-570S Touch Screen Controller The Next Generation Controller with Smartphone Technology

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

Product Guide Low Voltage Switchboard & Switchgear

REMOTE MONITORING AND ALARM SYSTEM

Design. Innovations in Integrated Control Systems

Ground Fault Protection Improvement Study

ADVANCED MONITORING AND DIAGNOSTIC SYSTEMS FOR INDUSTRIAL GAS TURBINES

Energy Commander Paralleling Switchgear

GE Energy Digital Energy. Zenith Energy Commander Paralleling Switchgear

Installation and Maintenance Manual for Dimako NERM Panels REV 4. NERM Reference Manual NERM Panels 1 of 7

EcoView Energy Management System

SIPROTEC Products and Solutions for Protection Systems

Dual-point heat-tracing control system

EQUIPMENT VIBRATION REPORT

Samsung SDS BMS Ver.2.0. Technical Specification

COST-EFFECTIVE SCADA SYSTEMS

FireNET Plus Wiring Instructions

DCS-100. intelligent damper control & monitoring system

Application Sheet Chilled/heated ceiling (4 pipe) with 6-way valve on analog output

Ridley Terminals Canada. Site HMI Station. In Central Office. Prepared by: Wayne Leung Controls Specialist. QCA Systems Limited

DELOMATIC 400, DM-400 HYDRO

4100U City and Relay Cards Installation Instructions

Remote fiber testing to improve SLA s

ASCO PowerQuest Power Monitoring and Control Systems

Enhanced FOUNDATION Fieldbus Physical Layer Diagnostics with the DeltaV System

Common Customer Challenges

Spectron LSN (Life Safety Network) Suggested Specifications

MODBUS MESSAGING to the S5 BATTERY VALIDATION SYSTEM

Products and systems

Monitoring of Electrical Equipment Failure Indicators and Alarming

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

ESP TECHNOLOGIES LIMITED

Heating and D.h.w. Controller RVL482 Basic Documentation

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

KEY FEATURES EASY ACCESS. Through web browser for both clients and administrators CLIENT MONITORING. Not dependent on access to site network

CONTROL SYSTEM D ESIGN, E NGINEERING & C ONSTRUCTION.

Life Cycle Considerations for Microprocessor Relays

DigiTrace NGC-family

Billion Watts Technologies. Professional Solar Monitoring & Management System

REA 105 Arc Protection Module. Operator s Manual

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Moulded case circuit brakers

C&I SYSTEM DIAGNOSTICS WITH SELF MONITORING AND REPORTING TECHNOLOGY (SMART)

DeltaV Analyze. Introduction. Benefits. Continuous automated DeltaV System alarm system performance monitoring

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

EnergyMaster. ENEC Monitoring System. An on-site supervision and remote monitoring solution

PRELIMINARY EDITION

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

Item/clause/Page no. Description as per tender. To be read as

Engineering Guideline. pac- Carriers Type Universal

Energy Management. Eos-Array. Launch Package 09. Michele Brena March, 2009

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

Control system. cabinet

SECTION : CAMPUS CENTRAL METERING SYSTEM DESIGN

wireless. web-based. worthy of the name RACO.

TR 0603mc U Solar Controller

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Transcription:

SOLAR POWER PLANT AUTOMATIO ON Submitted by:- I-Logicon Control Automation Pvt Ltd, Bangalore.

CONTENTS: 1. Abstract 2. SCADA and Reporting System Architecture 3. SCADA Components 4. Reporting System. 5. SCADA Screen shots. 6. Reporting Format Screen shots.

1. ABSTRACT: Supervisory control and data acquisition (SCADA) systems are used in Solar power plants for monitoring, control, remote communication purpose. The ingredientss of SCADA system in solar power plants is introduced in this manual. solar plant does not have any moving parts, as a result we need live and historical details about the plant, using a plant scada system that monitors all the critical field devices such as inverters, weather station, mfm, smb, lt/ht panel. All this combined to provide a live and plant comprehensive view of the entire solar plant with continuous alert system, viewed from anywhere (at site/corporate office) - on PC/Mobile. I-logicon Scada provides continuous 24x7 SCADA monitoring of: Power generation at plant, sub-plant, string level Energy exported to the Grid Environment ambient temperature, irradiation & wind speed Equipment Health Monitoring - inverters, grid equipment and modules (helping O&M field and remote staff, and owners) Detailed Reports and Graphs in near real time for effective O&M and Remote Monitoring Plant Performance - generation performance, uptime & efficiency, helping O&M and Plant Owners.

2. SCADA & REPORTING ARCHITECTURE :

3. SCADA Components : 25 Display Features : 1) Real time monitoring of plant data 2) Alarms and events with history 3) Real time and Historical Trend (SMBs and Inverters) Remote Monitoring Software: Features: 1) Remote Scada client through secure VPN network. Reporting System Locally and Remote view the Reports.

SCADA Screens OVER VIEW Here all the plant parameters can be monitored.which includes SMB data, Inverter data, LT & HT panel breaker status data, HT panel Relays, MFM and Annunciator data. Complete Plant Overview includes data collection from RTU 1, RTU 2 and Data Concentration Unit. 1) LT panel and HT panel Breaker status 2) SMB data include string current, total string current, Power 3) Inverter data include AC / DC parameters, inverter status.

4) Weather monitoring station monitoring includes Radiation, Accumulated radiation daily, Humidity, Ambient Temperature, Module Temperature etc. 5) Aux Panel Monitoring includes auxiliary consumption. 6) HT panel Incomer Relay data, Outgoing relay data, Incomer MFM s and Annunciator alarms and trip status. 7) CO2 suppression system and Fire Alarm status. 8) Alarm Banner Includes Most recent alarm. 9) Navigation to all the below mentioning pages are available in the overview screen. INVERTER TREND Inverter trend include Real time and Historical trending of Inverter data. Historical trend data available for a period of one week.

SMB TREND Smb trend includes Realtime and Historical Trending of SMB data.historical Trend values are available upto a period of one week. SMB LEVEL DATA

INVERTER DATA

MULTIFUNCTION METER 1) There are two sets of energy m meters at Incomer 1 and Incomer 2 at HT panel.

ABT ENRGY METERS 1) There are Two sets of Secure meters for both Outgoing feeders and each set of Secure meters contains Main and Check meters for redundancy.

WEATHER MONITORING STATION

INCOMER PROTECTION RELAY 1) There are two Protection relays monitoring at Incomer 1 and Incomer 2. 2) Alarm and indications based on fault.

OUTGOING 1 PROTECTION RELAY 1) Siemens Siprotec 7SD61 Relay parameters 2) Alarms based on fault

OUTGOING 2 PROTECTION RELAY 1) ABB REF615 Relay parameters 2) Alarms based on fault

ANNUNCIATOR 1) Incomer 1 and Incomer 2 Annunciators data. 2) Alarms and indications based on the annunciation window status.

MFM AUXILIARY PANEL

ALARM SUMMARY Alarms will be available in the alarm summary. Latest alarms will show in alarm banner available at the bottom of overview screen. Historical alarms are available for a period of 1 week. Alarm and log viewer is using for viewing old alarms.

4. Report Formats. Daily Energy Generation Report Weekly Energy Generation Report

Monthly Energy Generation Report THANK YOU