Exposed Wood in Fire Resistive Applications

Similar documents
FULL-SCALE FIRE TESTS OF A TWO-STORY CROSS-LAMINATED TIMBER STRUCTURE

Copyright 2018 American Wood Council 1

CLT Adhesive Tests in Support of Mass Timber Buildings

PERFORMANCE OF CLT ASSEMBLIES IN FIRE

Compartment Fire Testing of a Two-Story Mass Timber Building

Fire Resistance of Timber Structures

Evaluation on Combustion Characteristics of Finishing Materials for Exterior Walls

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

Fire Risk and CODE Compliance For Fabric Wrapped Acoustic Panels

Presented by: Bill Lauzon, PE Lauzon Life Safety Consulting, LLC Web: Lauzon-LSC.com

Appendix A: US Fire Statistics Tables

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Establishing the Risk Basis of Building Size Limits

2012 NC Building Code Chapter 2, 602.4, , , Chapter 35 Cross-Laminated Timber. ( Item B-1)

Mid Rise Timber Framing. Click here to start

IBC Committee Responsibility Matrix January 2017

6/9/ :58 PM. First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

VILLAGE OF DOWNERS GROVE Report for the Village Council Meeting

Canadian Code Requirements - Fire NBC Division A and Division B (Part 3)

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

F, T, L and W Ratings - What are the Code & Testing Requirements?

Performance Metrics for First Responder Locating/Tracking Technologies

NFPA 285 THE BURNING QUESTION

Reporting of Fire Incidents in Heavy Timber Structures

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

SHAPING A BETTER WORLD. Innovations in Buildings and Fire Safety Provisions Pierre Gaston and Neil Hitchen - Arup Friday 12 th October

H gh-p led Combust ble Storage. Application Guide 2009 Edition

Sprinklers in Wood-Frame Construction:

High-Rise Residential Building using Cross-Laminated Timber Charlotte 9 th Street Tower- United States Case Study

Ch. 54 GROUP B EDUCATIONAL 34 CHAPTER 54. GROUP B EDUCATIONAL OCCUPANCY GROUP

Materials Testing by Gregory Havel

This document is a preview generated by EVS

American Fire Sprinkler Association. An Introduction to the IBC and IFC

Fire Performance of Translucent Systems

Part 3 BUILDING CODE MYTHS & INTERPRETATIONS

Major Changes to the 2010 National Construction Codes Contractor s Breakfast January 2014

ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC # TESTED: MARCH 27, 2009

How design fires can be used in fire hazard analysis

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

PA 256 of 2011 Michigan Fireworks Safety Act What We Need To Know

Michigan Fireworks. Mike Evans Instructor # 2062 Program approval # A, 1S, 1T

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

Glenwood Springs Fire Protection District Amendments to the 2009 International Fire Code

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

ERRATA TO THE 2000 INTERNATIONAL FIRE CODE. Fourth Printing, January 2002 Updated March 29, 2002

FIRE-RESISTANCE-RATED CONSTRUCTION A Primer on IBC Chapter 7

Report on Public Input June 2014 NFPA 101

ANALYSIS OF SMOKE MOVEMENT IN A BUILDING VIA ELEVATOR SHAFTS

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

By: Russell Bainbridge March 18th, 2016 FPE 596

Managing Fire Safety in Occupied Buildings FM Ireland Fire Safety Theatre

Schedule of Accreditation

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss

Technical Supplement 14D. Geosynthetics in Stream Restoration. (210 VI NEH, August 2007)

Essentials of Fire Fighting 6 th Edition Firefighter I

Fire-Rated Glazing Changes in 2012 International Building Code (IBC)

UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

Oklahoma. 265: Incorporated national codes and standards The following national codes and standards are incorporated by reference:

Ohio Department of Health NFPA 2012 Life Safety Code Tips Sheet

Webinar November 12, 2014

Building Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1

Special Occupancy Requirements

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

COSTCO, SAN FRANCISCO A PRESCRIPTIVE AND PERFORMANCE BASED ANALYSIS OF FIRE PROTECTION SYSTEMS AND DESIGN

Common Building Code Misinterpretations

Union Mission: Restaurant/ Office/ Dorm. Index: Union Mission: Restaurant/ Office/ Dorm. Codes and Project Information:

For the Florida Building Commission And the Fire Code Advisory Council

Laboratories and Hazardous Materials. Company Overview

The Science Behind Water Mist Protection of Typical Building Hazards

Combustible Dust Hazards: Awareness & Safeguarding. Forest Industry Task Force on Mill Safety May 2012

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Public Comment No. 2-NFPA [ Section No ]

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

Building Description Applicable Codes & Standards Prescriptive Requirements. Performance Based Design

FUNDERMAX GMBH FIRE TEST REPORT

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

FM Approval Standard For Cavity Walls And Rainscreens

The Residences at Christina Landing Wilmington, DE

UNDERSTANDING SAFETY CABINETS

Air Moving Systems. Fire Safety Inspection and Testing of. NBSIR jan «1933. Washington, DC General Services Administration

Sprinklers in Combustible Concealed Spaces

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

Firefighting operations on multi-tiered vehicle stacking buildings F5-13 GD


Above Ground Fuel Tank Requirements

CHAPTER 5: EXHAUST SYSTEMS

FIRE PROTECTION AND SAFETY ANALYSIS FOR AN OFFICE HIGH RISE BUILDING. Fabio Mazza June 2016

Human Factors - Egress Analysis for High Hazard Occupancies. Presented by: Michael J. Klemenz, PE, SFPE

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: FIRE RETARDANT WOOD TREATMENT REPORT HOLDER:

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

Preview of the MA Building Code (780 CMR) 9 th edition

Loss Prevention Standards

Plan Submittal Checklist

Transcription:

Please add relevant logo here Exposed Wood in Fire Resistive Applications David Barber, Arup Disclaimer: This presentation was developed by a third party and is not funded by WoodWorks or the Softwood Lumber Board.

Content Why wood? IBC requirements Fire fundamentals Fire testing Applications to code compliant buildings Summary USDA: www.tallwoodbuildingcompetition.org

Why wood? Sustainability Aesthetics, innovation Changing technology Efficient construction Prefabrication A differentiator

Current approach CLT Glulam NLT Structural composite lumber (LVL, LSL, PSL)

What is a Fire Resistance Rating? Structural resistance Integrity Insulation (from CLT Handbook, US Edition )

What is Interior Finish Flammability? Classification for flame spread and smoke development ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials ( Steiner tunnel ) From Nordic

Wood Construction and the NYCBC Combustible construction Type III, IV, V Non-combustible construction Type I, II Wood is combustible construction Code compliant use in Types III, IV, V

Wood Construction and the NYCBC Type IIIA: Up to 6 stories (B and R uses) 1 hrfrr load bearing frame 2hr FRR load bearing external walls Type IV (heavy timber): As for Type IIIA Type V: Low rise, limited area, few restrictions

Wood Construction and the NYCBC Types III, IV, V wood can be exposed

What Does a Type IV HT Building Look Like? Up to 6 floors, with sprinklers Wood beams, columns, floors, roof permitted Exterior walls are noncombustible, or FRT wood Code sets minimum dimensions for members 10 Duratherm Presentation

AModern Type IV Building Up to 6 floors, with sprinklers Exposed wood Use of steel or concrete, where appropriate (hybrid construction) Glulam beams, columns; CLT floors and walls 11

Mass timber and fire - fundamentals

Combustibility - Just another engineering problem? APA

All materials are vulnerable to fire:

Wood - Fire fundamentals Schaffer, 1966, Forest Products Laboratory

Wood -Fire fundamentals 1hr exposure = 1.8in/hr 2hrs exposure = 1.58in/hr 90 minute FRR fire test on 270mm x 415mm glulam beam (from APA)

Wood -Fire fundamentals Calculating an FRR NYCBC 721.6 What is the area (b x d) needed? What additional wood cover is required, for an FRR (B x D) The difference (B b) is the sacrificial char layer TR-10 Fig 1-2

Wood Fire guidance FRR of wood NDS Chapter 16 Method explained in detail in TR-10 NDS is a compliant methodology for determining exposed wood FRR Includes method for CLT

Fire Testing

22

23

24

25

Hasburgh, FPL FPInnovations 26 FPInnovations FPInnovations

Exposed Timber Accounting for the added fuel Fire testing to date: Canada FPInnovations and NRC Switzerland ETH Sweden SP UK University of Edinburgh and Arup Australia University of Queensland US Fire Protection Research Foundation 27 US ICC double story compartment University of Edinburgh and Arup

What is the fire? NRC, Canada

29 Real building fire testing Fire Protection Research Foundation

30

31

Real building fire testing ICC Tests

Image from: Zelinka, Samuel L.; Hasburgh, Laura E.; Bourne, Keith J.; Tucholski, David R.; Ouellette, Jason P. (In press). Compartment fire testing of a two-story cross laminated timber (CLT) building. General Technical Report FPL-GTR-247. Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory.

Image from: Zelinka, Samuel L.; Hasburgh, Laura E.; Bourne, Keith J.; Tucholski, David R.; Ouellette, Jason P. (In press). Compartment fire testing of a two-story cross laminated timber (CLT) building. General Technical Report FPL-GTR-247. Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory.

Image from: Zelinka, Samuel L.; Hasburgh, Laura E.; Bourne, Keith J.; Tucholski, David R.; Ouellette, Jason P. (In press). Compartment fire testing of a two-story cross laminated timber (CLT) building. General Technical Report FPL-GTR-247. Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory.

Images from: Zelinka, Samuel L.; Hasburgh, Laura E.; Bourne, Keith J.; Tucholski, David R.; Ouellette, Jason P. (In press). Compartment fire testing of a two-story cross laminated timber (CLT) building. General Technical Report FPL-GTR-247. Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory.

What does the test data show? Fire self-extinguishing (Test 3) Fire re-growth (Test 1) 39 Carleton University CLT compartment fire tests

What does the test data show? Fire self-extinguishing (Test 3) Fire re-growth (Test 5) 40 FPRF fire tests 1-3 and 1-5 (one wall exposed)

CLT performance in fire Char fall off does not consistently occur Associated with certain adhesives Occurs well after 1hr of endurance E119 test, CLT floor after 2hrs, with char fall-off E119 test, CLT floor after 2hrs, with no char fall-off 41

Fire fundamentals: CLT

CLT performance in fire β= 1.5 /hr β= 3.0 /hr β= 1.5 /hr β= 3.0 /hr β= 1.5 /hr 1 1 Char fall off results in increased char rate at adhesive lines

CLT performance in fire A lot of fire testing has occurred CLT char fall-off is not new. Char fall off is caused primarily by adhesive type Char fall-off has a number of impacts, but they are predictable Char rate methodology developed for CLT Handbook and NDS, includes char fall-off Char fall off occurs outside the necessary fire endurance time frame for Type III, IV and V construction 44 New adhesives being used that have been proven to prevent char fall-off (issue identified, now being resolved) University of Edinburgh and Arup

What about mass timber connections? CLT panel to panel connections - resolved through testing Bearing condition matters Glulam beam to column shear connections: - No off-the-shelf solutions 45

Mass timber connections Can be expressed where no fire rating is required Where exposed and need a 1 hrfrr: Concealed steel plates Concealed bolts or dowels Design to conceal the whole connection Some connections will need detailed analysis

Glulam Connection Fire Testing Beam 1 = 8.75 x 18 (222mm x 457mm) Beam 2 & 3 = 10.75 x 24 (273mm x 610mm) Column = 15 square (381mm) CLT = 5ply 6.7 (170mm) thick Beam 1 = Loaded to 4,700 lbs (21kN) Beam 2 & 3 = Loaded to 20,000 lbs (90kN) 47

Beam 1 = Ricon 290 Beam 2 = 2 x Ricon 200

Beam 3 = Megant 430

Proven Fire Rated Glulam Beam Column Connections (ASTM E119) TEST BEAM CONNECTOR FRR 1 8.75 x 18 (222mm x 457mm) 2 10.75 x 24 (273mm x 610mm) 3 10.75 x 24 (273mm x 610mm) 1 x Ricon 290 1 hr 2 x Ricon 200 1.5hr Megant 430 1.5hr Test reports issued see ReThink Wood website Partners: Softwood Lumber Board Arup MyTiCon 57 DR Johnson

Exposed Wood? Not all authorities are supportive of exposed wood Sometimes an alternative materials submission is required to support use Significant variance in interpretation of the NYCBC and IBC with regard to Type IV Significant fire testing has been undertaken Fire testing can be used to support projects

Questions? David Barber Arup david.barber@arup.com