CARETAKER PLUS: MOST FREQUESNTLY ASKED QUESTIONS. Which sensor programming group should I use for a wireless freeze sensor?

Similar documents
COMMANDER 2000: MOST FREQUENTLY ASKED QUESTIONS

ITI Caretaker Basic Commands

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

Congratulations! This manual consists of four sections: SECTION 1 introduces you to the components of your CareTaker system.

Watchguard WGAP864 User Manual

Concord 4 User Manual

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

SuperBus Hardwire Output Module (HOM) Document Number: Rev. D March 1999

Safewatch Pro 3000 System Manual

Contents. Glossary

AXI LED USER MANUAL (REV. 1.0)

All-In-One Wireless Security System V1.0. Model #: MG-6060

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Area Systems While the alarm bell or siren is sounding, enter your user code. The system silences the alarm bell or siren.

Technical Manuals Online! A B C DEF GHI JKL POWER 9 0 COMMAND YZ. User's Guide

Version 1.03 January-2002 USER S MANUAL

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

IDS816 User Manual H Issued January 2009

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

System Introduction. 1.1 Specifications

Installation Instructions

DSC PowerSeries NEO Quick Start Guide

XRSuper6. User s Guide

User s Manual. System Information... 3 Using the Touchpad Buttons... 3 General Operation... 4 Using Systems with Keyswitches... 4

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Rev C December Part Numbers: R Concord. User Instructions

Silencing an Alarm All/Perimeter and Home/Away Systems. Area Systems. What to do when a trouble tone is sounding

TABLE OF CONTENTS TABLE OF CONTENTS 1

BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice.

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

U ser's Guide PC6010

2000 Series. Program Entry Guide. Control Panels

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

DESTINY OWNER S MANUAL

3 User s settings. 3.3 Internal clock setting

Simon XTi Quick Operation Guide

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Control/Communicator

Silencing an Alarm. When the alarm siren is sounding, enter your user code or present your card to a keypad during the Status List display.

Destiny Destiny Owners Manual

L900 series USER MANUAL

System Introduction. 1.1 Specifications S E C T I O N 1

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Control/Communicator Installation Manual

JA-63 Profi User manual

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Silencing an Alarm All/Perimeter Home/Away Systems Area Systems

Fire Command Center. XR2400F User s Guide

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD

VISTA-50P VISTA-50PUL

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

D1265. User's Guide. Touchscreen Keypad

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

ELECTRONICS LINE S TECHNICAL SUPPORT DEPARTMENT: (972)

P Zone Expandable Hybrid Security System

CC408. Quick Reference Guide Solution 880

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

User's Manual VISTA-40 N7003V1 6/97

AdvisorOne Quick Operation Guide

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

RE6100 Series Helix Security and Automation Platform

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

HILLS Series LCD Code Pad User Manual

**** **** A B ARMED FIRE FIRE C D READY OFF AWAY STAY 2 3 MAXIMUM TEST BYPASS PULL INSTANT CODE CHIME. First Alert READY. * 0 # Professional

Simon XT User Manual R-11 and R-11-CN P/N REV B ISS 13JAN11

ALARM SYSTEM USER S MANUAL Rev

Wireless Security System

SECURITY SYSTEM NOTES

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

XTL/XTLN/XTLN-WiFi USER GUIDE

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

Silencing an Alarm. When the alarm siren is sounding, enter your user code or present your card to a keypad during the Status List display.

User s Information Guide R2A

X64 Wireless Training

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

JA-63 PROFI Alarm System MGK55402

XTL Series USER GUIDE

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

Model 17A00 Expansion Enclosure

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

Digiplex LED Keypads User s Manual

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002

LCD and 16-Zone LED Keypads. User s Manual

NetworX NX-8V2. LED Keypad User Manual

WLS900 Wireless Security System. Table of Contents. Your installing company is, Name: Address: Phone: Your monitoring station is, Name: Phone:

Technical Manuals Online! - Enter Code Power NO DELAY. Stay. Away. Away A. Stay. Off. Off. Status. ALARM - Both Flashing

Transcription:

CARETAKER PLUS: MOST FREQUESNTLY ASKED QUESTIONS Which sensor programming group should I use for a wireless freeze sensor? Group 29 (Auxiliary Environmental) is the sensor group for freeze or water sensors. It is a 24-hour, Instant, Auxiliary Interior siren type, is active in all protection levels, and reports to the central station. How do Entry/Exit Delay sensor programming groups 10, 11, and 12 work together? Groups 10, 11, and 12 are Entry/Exit Delay sensor groups with the following differences: Sensors programmed to Group 10 can have separate entry and delay times (programmable from 8 to 88 seconds). Sensors programmed to Group 11 have the same entry and exit delay times (programmable from 1 to 8 minutes). Sensors programmed to Group 12 have the same entry and exit delay times and are twice the delay times programmed for group 11. How do the delays cascade or affect each other? Delays affect each other differently depending on whether they are on entry or exit: On entry, delays cascade down (the lesser time remaining of the zone group already open or the next delay zone activated). On exit, programmed delays cascade up (the greater time remaining of the group you already have open or the next delay zone activated). For example, let s assume an overhead garage door is assigned to Group 11 and both of its entry and exit delays are programmed for 1 minute. A garage-to-house service door is assigned to Group 10 and both of its entry and exit delays are programmed for 32 seconds. Opening the overhead garage door upon entry (from outside) will start its 1 minute timer counting down. When the service door is opened, the time remaining on the overhead door 1 minute timer or the service door 32 second delay timer, whichever time is less, becomes the entry delay time remaining. Opening the service door upon exit (from inside) will start its 32 second delay timer counting down. When the overhead door is opened, whatever time remaining on the service door 32 second delay timer is canceled and the overhead door 1 minute delay timer is started.

Why doesn t pressing the BYPASS button allow the system to arm when it is protesting an open sensor programmed to Group 26? For personal safety reasons, sensors programmed to Group 26 (24-hour Fire sensors) cannot be bypassed or ignored. What are the four types of 4/2 format reports that can be sent to the central station? The four types of 4/2 format reports that can be sent to the central station are: Alarms, Cancels, Troubles, and Restorals. How do the STATUS, BYPASS, COMMAND, and FIRE buttons work differently in the program mode of operation? In the program mode of operation the STATUS button Scrolls backwards through the displayed list. It can also can be used to erase incorrect entries and allow you to re-enter the correct entry. BYPASS button COMMAND button Scrolls forward through the displayed list. Enters program sub menus and also enters keyed-in or displayed data into the panel memory. FIRE button Exits from the displayed sub menu back to the main menu. Does turning on the Touchpad Quiet feature affect all of the system s alphanumeric touchpads? Turning on the Touchpad Quiet feature affects only the touchpad from which it is being set. Touchpad Quiet can be set at selected touchpads. Why run a Customer Sensor Test after completing the installation? A Customer Sensor Test is run after completing the installation to quickly verify that the installed sensors are all transmitting to the panel, the backup battery is OK, and to instruct the customer how to do a sensor test themselves.

Why should I use Dealer Sensor Test to test the system during installation? The Dealer Sensor Test is used to determine if sensors are transmitting and if sensor locations are acceptable before being permanently installed. An actual wireless signal strength-to-noise test is performed. What does the optional Feature Expansion Module (FEM) provide? The optional Feature Expansion Module (FEM) provides increased voice volume on alarm. a special switched DC power supply for resettable hardwire smoke detectors. interface for an optional Energy Saver Module (ESM). How does the optional Energy Saver Module (ESM) work? The optional ESM works like a switch that takes control the heating or air conditioning away from the thermostat and allows the premises to heat up or cool down beyond the normal thermostat comfort levels. Thus saving energy when no one is home. Does it matter where I locate and mount the ESM? Yes, it does matter where the ESM is located. It should be mounted as close to the existing thermostat as possible so that they both ìseeî the same temperatures at the same time. How many optional Energy Saver Modules (ESMs) can be used in a system and why? Only one ESM is allowed per system. There are no capabilities to program high- and lowtemperature settings for multiple ESMs. What is a Buddy system? A buddy system is two or more neighboring ITI SX-V or Learn Mode systems within wireless range of each other that will communicate with the central station should there be a phone failure on one of the systems.

How do I wire, program, and learn a buddy transmitter? In general, the buddy transmitter is a SX-V or Learn Mode wireless door/window sensor with its external contact terminals wired to the local panels fail to communicate and ground terminals and then learned into the neighboring panels memory. To wire, and program a Learn Mode buddy transmitter: 1. Connect the external contact + terminal to the panel terminal 20 (FTC) and the external contact terminal to panel terminal 11 (Gnd). 2. Learn the Learn Mode transmitter into the neighboring panel memory while the transmitter is in the alarm state. Do this by shorting the transmitter external contacts (panel software version 2.0) or leaving the external contact terminals open (panel software version 1.0) and then tripping the transmitter tamper switch. Select a sensor group such as 02 (24- hour fixed panic). What should I measure between terminals 24 (Brown) and 25 (Gray) with the phone line disconnected from the panel and why? You should measure 18 to 20VDC between terminals 24 (Brown) and 25 (Gray) with the panel power on and the phone line disconnected from the panel. This is sufficient voltage to power the local phones and allow for local system phone operation even with a phone line failure (no incoming phone voltage). Do all versions of panel software allow the use of an Interrogator? No. Only panel software version 2.0 or later supports the use of an interrogator. How do I know what software version the panel has and how do I get new software? The software version number is labeled on the large (64-pin) integrated circuit located near the center of the panel circuit board. You can obtain a software upgrade kit by contacting ITI Order Entry or Customer Service and ordering ITI part number 15-187. What should I check when the system displays or announces a battery failure?

If the system displays or announces System Battery Failure check the panel backup battery (a low battery will measure 5.6VDC or less) and/or backup battery charging voltage (should measure 6.8VDC with the battery disconnected). If no charging voltage exists, check for a blown (open) pancake (automatic resetting) or barrel (replaceable) shaped fuse on the circuit board in series with the battery lead. If the system displays or announces Sn nn Low Battery check the specific wireless sensor battery. What are the typical voltage readings from terminal 11(Gnd) to terminals 10 (+DC In), 12 (CCS), and 13 (AC) when the line carrier type of AC power transformer is plugged in and the panel power switch is on and off? You should measure the following: Terminals On Voltage Off Voltage 11-10 9-12VDC 12-13.5VDC 11-12 5VDC 5VDC 11-13 5VAC 5VAC