GreenJet Transfer Fans

Similar documents
GreenPark. GreenJet Throw Performance

Plenum Fans. Model HPA. Direct Drive

Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety

Electric Duct Heaters. IDHB & IDHC Series

Tunnel Transit Dampers. Heavy Duty Tunnel Transit Life Safety

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

Introduction to Fans. The Basics of Fan Principles and Terminology

Indirect Gas-Fired Make-Up Air

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

Modular Supply Make-Up Air Unit

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

Direct Gas-Fired Make-Up Air

SMOKE CONTROL - NEW DIRECTIONS

incorporating Contractors guide to car park ventilation A no-nonsense guide to the safe ventilation of underground and covered car parks

Energy Recovery with Cooling and Heating

Fan Selection. and Energy Savings

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Tunnel Axial Flow Fan

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Myth & Reality of Basement Ventilation

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

Selecting the Correct Fan

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

Understanding Fan System Effects

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Life Safety Dampers Selection and Application Manual

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Energy Recovery Ventilators

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Technical Information

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

Fans: Features and Analysis

Industrial Fans & Blowers

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

High Performance Vane Axial Fans

Glossary of Terms Laboratory & Fume Exhaust Fans

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Installation, Operation and Maintenance Manual

DACC Health Sciences Building Air Handler Assessment/Study

2015 MECHANICAL CODE REQUIREMENTS

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Underground carpark ventilation

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

Home Performance Energy Audit Report

Outside Air Requirements... SOLVED!

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Home Performance Energy Audit Report

Gas-Fired Unit Heaters Commercial & Industrial

Energy Recovery with Cooling and Heating Model ERCH

AXIAL & JET FANS FOR TUNNEL VENTILATION

CALIFORNIA MECHANICAL CODE OVERVIEW OF 2016 UPDATES CHANGES AND RAMIFICATIONS

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

A. Codes and Standards that are Standard at the University:

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

TUNNEL FANS STANDARD AND HOT SMOKE

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

It's simple... we move more air for less! The Kelley FUSION fan circulates the greatest volume of air while consuming the least amount of energy.

Modular Heating & Ventilating Unit Model IGX-HV

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

SECTION AIR DUCT ACCESSORIES

Optiline Fan Array. The optimum number of fans for every application. The Optimum in Sound Energy Size Redundancy Reliability.

CAT-SIUH-2000(3) SUPERSEDES CAT-SIUH-98(2) SARAVEL INDUSTRIAL UNIT HEATERS

Smoke detection in hazardous areas:

1.1 This section applies to air handling units for HVAC Systems.

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

CONTENTS. B. System Design and Performance Requirements

Featuring Vent Lights and Premium Grilles

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

Home Performance Energy Audit Report

Work In Shirt-Sleeve Comfort When It s Doggone Cold

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Gil Rossmiller. In the construction industry for over 30 years. ICC IRC Plumbing & Mechanical Code Development Committee

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

SECTION (15833) - HVAC POWER VENTILATORS

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SECTION AIR HANDLING UNIT

technical specification smoke venting systems

Installation, Operation and Maintenance Manual

B. System Design and Performance Requirements

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

ADVANCING HVLS technology through controls and energy efficiency

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

Catalog Destiny Indoor Air Handler. Models Horizontal Configuration. Vertical Configuration

48TM GAS HEATING/ELECTRIC COOLING UNITS

MECHANICAL VENTILATION

APPLICATION, INSTALLATION, AND MAINTENANCE MANUAL CA2XRT, CA3XRT, CA4XRT

Direct Gas-Fired Make-Up Air Models DGK, DG and DGX

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

DESCRIPTION OF TECHNOLOGY

LUH HORIZONTAL FAN-FORCED UNIT HEATER

Car Park Ventilation 1

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

Fan Performance and Selection. Overview

Transcription:

GreenJet Transfer Fans Model GJX High Performance Axial Transfer Fan April 2018

GreenJet As cars park in an underground parking structure, carbon monoxide (CO) and other noxious fumes are emitted into the atmosphere. There is a need for an efficient ventilation system to remove these toxins, circulate fresh air into the car park, and assist firefighters with smoke control in the case of a fire emergency. The GreenJet model GJX includes a range of performances to accommodate your needs for parking garage ventilation. While ducted ventilation has been the standard for many years, innovation in technology has shifted systems toward ductless designs. Ductless designs use transfer fans to dilute and remove contaminants and control the smoke. In addition, these systems provide greater control and operational savings. Improved Exhaust Effectiveness with GreenJet Ducted System Fresh air intended to replace contaminated exhaust is removed along with contaminates through each duct. The illustration below shows ducts closer to the supply air remove much of the fresh air, leaving mostly toxic air at the farthest duct, causing a hazardous condition. Ductless with GreenJet Transfer Fans GreenJet transfer fans push fresh supply air through the parking area towards the exhaust fan(s). This removes a higher proportion of contaminated air and replaces it with clean air. Supply Air Exhaust Air Supply Air Exhaust Air Carbon Monoxide (CO) Contaminate Concentration Level Low Medium High Advantages: Simplified Design: Eliminates the need and expense of designing a duct system. Lower Construction Cost: GreenJet fans require less height against the ceiling than a ducted system. This means the required height of each level is less, reducing excavation and lowering overall construction cost. Lower Installation Cost: A typical GreenJet system results in less installation time. Improved Operational Costs: Eliminating ductwork reduces the system static pressure and allows for smaller supply and exhaust fans to run using less power. The use of third-party exhaust sensors allows for demand-based ventilation. Reduced Maintenance: GreenJet fans are more accessible for maintenance than traditional systems, and eliminate duct cleaning. Enhanced Safety: GreenJet fans are more efficient at removing noxious fumes and clearing smoke, resulting in a safer environment. UL/cUL 705 Listed Power Ventilator File No. E40001 UL/cUL Power Ventilator for Smoke Control Systems File No. MH17511 AMCA licensed air performance may be found in Greenheck s Computer Aided Product Selection program (CAPS). 2

Construction and Installation GreenJet model GJX is a low profile, quiet fan suspended from the ceiling. Construction features include: Durable steel casing with Permatector coating for corrosive environments Mounting brackets flush with the top of the silencers for no additional height Airfoil propellers move large volumes of air with high efficiency in a small diameter fan Sound absorbing inlet and outlet silencers with perforated inner liner for maximum sound reduction Aerodynamic inlet design improving performance efficiency. Inlet and Outlet Silencers Flush Mounting Brackets Inlet and Outlet Guard Casing When installed ceiling hung, GreenJet moves the air towards the exhaust area by effectively creating a continuous flow, avoiding the creation of stagnant zones where air may become trapped. Ductless Garage Ventilation: Supply Transfer Exhaust Typical installation and operation of ductless, enclosed parking garage HVAC systems consist of supply fans, GJX GreenJet fans, and exhaust fans. Under normal conditions, fresh air is introduced into the garage through entrance/exit ramps and through a dedicated supply fan. The GreenJet model GJX fans are positioned to direct air from one end of the garage to the other, supplying fresh air to the structure while also mixing and pushing contaminated air towards the point of exhaust (typically on the end opposite the supply). An exhaust fan removes the contaminated air from the garage. A timer, occupancy monitor, or demand-based control system can operate the entire system. The GJX fans are available with Smoke Control certification for integration into a smoke exhaust control system. GJX is intended to provide emergency responders a clear path for better and more effective access. Exhaust Fan GJX GreenJet 3

Design Layout Fan Placement and Velocity Profiles Successful operation requires the correct fan quantities, placement, and direction of the transfer fans. Discharge velocity profiles is a tool to provide a starting point for initial fan placement. GreenJet velocity profiles are available for integration in an AutoCAD layout. The images below show the use of Computational Fluid Dynamics (CFD) to develop a 200 fpm velocity profile and integration into a design layout. Car park layout with GJX velocity profiles added giving initial placement locations. CFD velocity profile for a GJX-41 showing 200 fpm throw of 110 ft (33 m). CFD Analysis There are different CFD analyses often used in parking garages: Velocity analysis provides information on air movement but not the effect on contaminate removal. CO analysis provides the effectiveness in removing contaminants from the parking garage. Smoke removal analysis shows how quickly and effectively smoke is removed from the source point. Natural airflow paths from supply to exhaust locations exist within a building structure. Integrating transfer fans moves air outside of these pathways. An analysis on CO levels illustrates the impact of the GJX GreenJet fan installation on a parking garage. Without Jet Fans With Jet Fans 4

System Integration and Payback Integration of GreenJet model GJX fans into Demand-Based Application A demand-based system is controlled using sensors that measure parts per million (ppm) of contaminants and sends information to the the facilities controller to increase or decrease speed based on actual conditions. The image below shows how the GJX GreenJet is integrated into this application. A VFD can be used with multiple GJX fans in a zone for lower controller costs. Energy Saving with Demand-Based Ventilation There are two methods for controlling parking ventilation systems; an On / Off system where the ventilation is on a timer or occupancy sensor, or demand-based with sensors changing the ventilation rate with contaminate levels. Simplified Example: Control Method Operation Ventilation Rate* (cfm per ft² of garage floor) Operating Time (hours) Daily Operating Volume (ft³ per ft² of garage floor) On / Off Full 0.75 12 540 Demand-Based Full 0.75 2 (average) Reduced 0.15 10 180 *Full flow uses a 0.75 cfm/ft² (ASHRAE 62.1-2013) ventilation rate per square foot for garage area and reduced flow using 0.15 cfm/ft² (California Title 24). In this example, a demand-based method results in a 66% reduction in the ventilation requirement and related energy savings. Five times the difference in prescribed ventilation rates between systems with and systems without air quality monitoring and control. 5

Performance and Dimensional Data Fan Size GJX-31-160-0634 GJX-31-160-0625 GJX-36-160-0627 GJX-36-160-0622 GJX-41-160-0623 GJX-41-160-0616 *Air density = 0.075 lb./ft 3 **Throw distance for 200 ft/min Airflow cfm (m³/hr) 2,640 (4,485) 2,250 (3,823) 4,070 (6,915) 3,620 (6,150) 6,010 (10,211) 5,050 (8,580) Thrust lbs (N)* 5.6 (24.9) 4.1 (18.2) 9.9 (44.0) 7.8 (34.7) 16.6 (73.8) 11.7 (52.0) Throw ft (m)** 85 (25.9) 75 (22.9) 100 (30.5) 90 (27.4) 115 (35.1) 105 (32.0) Power Bhp (kw) 1.26 (0.94) 0.74 (.55) 1.94 (1.45) 1.48 (1.1) 2.94 (2.19) 1.95 (1.45) Motor Size HP (kw) 1.50 (1.1) 0.75 (0.56) 2.00 (1.5) 1.50 (1.1) 3.00 (2.2) 2.00 (1.5) Motor Speed dba Inlet @ 5 ft 3500 71 3500 69 3500 73 3500 74 3500 77 3500 78 The performance shown is not AMCA licensed as it includes losses from appurtenances (accessories) in the airstream. Licensed data may be found in Greenheck s Computer Aided Product Selection program (CAPS). Dimensional Data AIRFLOW DIRECTION Silencer C I Silencer Junction Box Fan Dia. F H D E B A B G Size (cm) 31 36 41 A B C D E F G H I 17.01 (432) 17.01 (432) 20.00 (508) 24.49 (622) 28.50 (724) 32.52 (826) Dimensions shown in inches (millimeters). *Weight includes largest motor for size. 14.80 (376) 14.80 (376) 17.81 (452) 12.24 (311) 14.25 (362) 16.26 (413) 16.18 (411) 18.19 (462) 20.20 (513) 10.28 (261) 12.28 (312) 14.29 (363) 10.04 (255) 11.02 (280) 12.05 (306) 8.31 (211) 9.29 (236) 10.31 (262) 0.47 (12) 0.47 (12) 0.47 (12) Weight* lbs. (kg) 143 (65) 152 (69) 170 (77) Model Number Code GJX - 31 - L - 160-06 25 - M 20 - X Fan Size (cm) 31, 36, 41 Casing Hub Size Number of Blades Blade Pitch Fan RPM M = 3500 Certification None X - UL/cUL 705 Listed (Electrical) HTUL - UL/cUL HT Listed (Emergency Smoke Control) Motor Horsepower 7 = ¾ 15 = 1½ 10 = 1 20 = 2 30 = 3 6

Certifications & Additional Products for Car Park Ventilation Emergency High Temperature Smoke Removal The GreenJet model GJX is UL Listed for Smoke Control. It is high temperature performance tested and rated for design time used in emergency heat and smoke exhaust applications. Emergency Temperature Options: 150 C / 5 Hours (302 F / 5 Hours) - per British Standard 7346 (Components for smoke control systems) 260 C / 4 Hours (500 F / 4 Hours) - per Industrial Risk Insurers (North America) UL/cUL Power Ventilator for Smoke Control Systems File No. MH17511 Life Safety Dampers Life safety dampers are intended to protect openings in walls, ceilings, floors and/or partitions to prevent the spread of fire and/or smoke. These are necessary in multi-level car parks with common shafts to prevent the spread of smoke from one floor to another. Fire dampers are required by all building codes to maintain the required fire resistance ratings of walls, partitions and floors when penetrated by air ducts and transfer openings. These products were tested and classified in accordance with UL Standard 555. Smoke Dampers have two applications: 1. These may be applied in a passive smoke control system where they simply close and prevent the circulation of air and smoke through a duct or a ventilation opening in a smoke barrier. 2. These may be applied as part of an engineered smoke control system designed to control the spread of smoke using walls and floors as barriers and using the building s HVAC system and/or dedicated fans to create pressure differences. These products are tested and classified in accordance with UL Standard 555S. Combination Fire Smoke Dampers perform the function of both a fire damper and a smoke damper. Building layouts and designs often combine fire and smoke rated partitions and barriers requiring the installation of both a fire damper and smoke damper at the same location. These products are tested and classified in accordance with both UL 555 and UL 555S. Supply and Exhaust Fans Greenheck s high performance fans are ideal for air ventilation in commercial, industrial or institutional buildings. Design and construction are well suited for indoor or outdoor applications and can be easily installed in ducted or non-ducted systems. Fans are designed to reduce operating costs with improved efficiency. AMCA Licensed Performance UL/cUL Listed for Electrical 705 UL/cUL Listed for Power Ventilators for Smoke Control Systems Spark resistant construction 7

Design and Selection Support Enjoy Greenheck s extraordinary service, before, during and after the sale. Greenheck offers added value to our wide selection of top performing, energy-efficient products by providing several unique Greenheck service programs. Our Quick Delivery Program ensures shipment of our in-stock products within 24 hours of placing your order. Our Quick Build made-to-order products can be produced in 1-3- 5-10-15- or 25 day production cycles, depending upon their complexity. Greenheck s free Computer Aided Product Selection program (CAPS), rated by many as the best in the industry, helps you conveniently and efficiently select the right products for the challenge at hand. Greenheck has been Green for a long time! Our energy-saving products and ongoing corporate commitment to sustainability can help you qualify for LEED credits. Our 3D service allows you to download at no charge, lightweight, easy-to-use AutoDesk Revit 3D drawings for many of our ventilation products. Find out more about these special Greenheck services at greenheck.com Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. Prepared to Support Green Building Efforts P.O. Box 410 Schofield, WI 54476-0410 Phone (715) 359-6171 greenheck.com 00.LAB.1020 R1 4-2018 RG Copyright 2018 Greenheck Fan Corp.