Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

Similar documents
Condumax CLS16 and CLS16D

SECTION ph/orp Sensors

Operating Instructions Indumax CLS54D

Technical Information OUSBT66

Technical Information OUSAF44

Liquiline M CM42. Technical Information

Operating Instructions. Condumax CLS15/16/21. Analog sensors For conductive measurement of conductivity in liquids BA01148C/07/EN/01.

Technical Information OUSTF10

Technical Information OUSBT66

Technical Information OUSAF21

Technical Information OUSAF12

Technical Information OUSAF22

Operating Instructions Condumax CLS15/16/21

Stratos MS. Internationally recognizable icons provide operating information and draw attention to unusual operating states.

SECTION Fluorescent Dissolved Oxygen Measuring System

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

Concise catalogue Water-Industry

Indumax CLS50/CLS50D. Operating Instructions. Analog or digital sensors with Memosens protocol For inductive measurement of conductivity in liquids

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

For very low to medium/high conductivity: Where optimal performance is essential. INGOLD Leading Process Analytics

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

Personal ph, ph/orp, Conductivity Meters

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Model Q45P/R. ph/orp Monitor...

Model Q45P/R. ph/orp Monitor...

Personal ph, ph/orp, Conductivity Meters

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Effluent Monitoring. Solutions

Gas cylinder scale Model GCS-1

SECTION Free/Available Chlorine Analysis System

Druck DPI 705/DPI 705 IS Series

Dräger X-am 7000 Multi-Gas Detection

Rosemount 4500 Hygienic Pressure Transmitter. Start

Dräger X-am 5000 Multi-Gas Detection

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Dräger X-am 5000 Multi-Gas Detection

Personal ph, ph/orp, Conductivity Meters PH71/PH72/SC72

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Transmitter Series. Intelligent Transmitter Series Tailor the Measurement to Your Needs INGOLD

Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications

WIDE SEARCH AREA HAND-HELD METAL DETECTION SET

NEW GENERATION COMPACT HAND HELD METAL DETECTION SET

GasAlertMicroClip X3 Specifications

Inductive Conductivity

USER MANUAL USB Multi-Function Datalogger Model RHT35

Dräger Polytron 7000 Fixed gas detector

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET FEATURES

Dissolved Oxygen Measurement liquisys M COM 223 / 253

PD140N NEW GENERATION COMPACT HAND HELD METAL DETECTION SET. Threat Detection through Electromagnetics. NIJ Compliant.

Ultrasonic Level Measurement nivopuls FDU 10 S

OPTISENS TUR 2000 Technical Datasheet

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Turbimax CUE21 / CUE22

Our Extended Personal Electronic Dosimeter (PED) Family

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Figure 1 DirectLine DL423 Sensor. Description, continued

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET

Free Chlorine Measuring System

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

Dissolved Oxygen Measurement liquisys S COM 223 / 253

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Micro/Ultra Filtration System StamoClean CAT 430

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

Dräger X-am 5000 Multi-Gas Detector

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Operating Instructions Liquiline CM442/CM444/CM448

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Internet. Climate rating definitions. Customer service.

Constant climate chambers

Food safety can be measured. Check limit values, ensure quality, comply with HACCP with measuring instruments from Testo.

Technical Information OUSTF10

Key benefits. Why Condair CP3?

Huminator II. Precision Humidity Generator. ww.testo.in

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

CO warning instruments and gas spillage detectors

AS950 PORTABLE SAMPLERS

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

PURSense Sanitary Flange Conductivity Sensors

Level Measurement Continuous level measurement Ultrasonic transmitters

Portable central unit for several parameters

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

Model 144H. Product Data Sheet , Rev DB February Content

Steam and Water Analysers

Rosemount 372. HF Resistant ph sensor. Quick Start Guide LIQ-QSG-372 Rev. C June 2017

Temperature Measurement Transmitters for field mounting

Chlorine / Chlorine Dioxide Measurement liquisys S CCM 223 / 253

Dräger X-zone 5500 Area Monitoring

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

Rosemount 4500 Hygienic Pressure Transmitter

Smart Sensors and Analytical Instruments Honeywell Solutions for Analytical Measurement and Control

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Figure 1 DirectLine DL423 Sensor. Description, continued

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Transcription:

TI01198C/07/EN/03.16 71326008 Products Solutions Services Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291 Portable multiparameter device for Memosens ph, conductivity and oxygen sensors. Measuring device for hazardous and non-hazardous areas Application Liquiline To Go is a portable multiparameter handheld for ph, ORP, conductivity and oxygen measurement. The outstanding features of the device include: Operation in hazardous areas to Zone 0 (CYM291) Use of digital Memosens sensors The robust, high-performance polymer housing stands for excellent shock resistance and dimensional stability even with intensive impact from moisture. Your benefits Reliability and flexibility Easy commissioning Memosens: plug & play lab-calibrated sensors Waterproof and robust housing with IP66/67 protection Safety Active indication of cable disconnect CYM291 Ex Approvals: IECEx, ATEX

Function and system design Liquiline To Go CYM290 and Liquiline To Go Ex CYM291 are portable multiparameter measuring devices for the use of analog (CYM290 only) and digital sensors. The device automatically detects when a Memosens sensor is connected and switches to the appropriate measured variable. By simply plugging in a new Memosens sensor, the device can measure conductivity, the ph value and oxygen. Operation is simple and intuitive, and supported by info text and help. Liquiline To Go CYM290 QVGA TFT illuminated display Liquiline To Go Ex CYM291 LCD STN 7-segment display with 3 lines and icons 1 4 2 3 1 Liquiline To Go functions 1 Connections 2 Display 3 Keypad 4 Holder for ph sensors A0024765 2 Endress+Hauser

Communication and data processing Liquiline To Go CYM290 and CYM291 automatically detects when a Memosens sensor is connected and switches to the appropriate measured variable. Memosens is indicated on the display. Only one sensor can be connected to the measuring device at the time. Liquiline To Go CYM290 has a phsocket according to DIN 19262 for analog ph sensors. Dependability Reliability Maintainability Integrity Memosens technology digitizes the measured values in the sensor and transmits the data to the transmitter using a non-contact connection that is free from potential interference. The result: Automatic error message if sensor fails or connection between sensor and transmitter is interrupted Immediate error detection increases measuring point availability Easy handling Sensors with Memosens technology have an integrated electronics unit that stores calibration data and other information (e.g. total operating hours and operating hours under extreme measuring conditions). Once the sensor has been connected, the sensor data are transferred automatically to the transmitter and used to calculate the current measured value. As the calibration data are stored in the sensor, the sensor can be calibrated and adjusted independently of the measuring point. The result: Easy calibration in the measuring lab under optimum external conditions increases the quality of the calibration. Pre-calibrated sensors can be replaced quickly and easily, resulting in a dramatic increase in the availability of the measuring point. Maintenance intervals can be defined based on all stored sensor load and calibration data and predictive maintenance is possible. The sensor history can be documented on external data carriers and in evaluation programs. Thus, the current application of the sensors can be made to depend on their previous history. With inductive transmission of the measured value using a non-contact connection, Memosens guarantees maximum process safety and offers the following benefits: All problems caused by moisture are eliminated. Plug-in connection remains free from corrosion Measured value distortion from moisture is not possible. The plug-in system can even be connected under water. The transmitter is galvanically decoupled from the medium. EMC safety is guaranteed by screening measures for the digital transmission of measured values. Endress+Hauser 3

Input Measured variables Measuring range Types of input Documentation of the connected sensor Documentation of the connected sensor Connections From right to left 1x micro USB-B for battery-free operation 1x M8 socket, 4-pin, for Memosens laboratory cable 2x socket, Ø 4 mm, for separate temperature sensor 1x socket: CYM290: DIN 19 262 for analog PH sensors CYM291: M12 8-pin Memosens cable 2 CYM290 connections A0024762 3 CYM291 connections A0024763 Temperature inputs Sensor inputs 2 x Ø 4 mm for integrated or separate temperature sensor Measuring ranges Temperature sensor NTC30: -20 to +120 C (-4 to 248 F) Temperature sensor Pt1000: -40 to +250 C(-40 to 482 F) Measuring cycle Approx. 1s Measured error 123 < 0.2 K (Tamb = 23 C); TK < 25 ppm/k 1) according to DIN EN 60746-1, at rated operating conditions 2) ± 1 digit 3) plus sensor error Cable specification M8 socket, 4-pin, for Memosens laboratory cable CYK20 4 Endress+Hauser

Power supply Supply voltage Batteries: 4x AA (Mignon) alkaline or 4x NiMH rechargeable batteries Service time of up to 500 h Performance characteristics Repeatability Documentation of the connected sensor Setting up the device Options A0024707 Protective cover The front of the device is protected by a cover. To operate the device, the protective cover can be folded back completely and locked in place. Hook A fold-out hook is located on the back of the device, allowing you to suspend it. This means your hands are free for the actual measurement. The nameplate is located under the hook. Stand The protective cover and hook can be joined to form a stand, allowing the convenient and ergonomic operation of the device in the lab or on a desktop. Endress+Hauser 5

Environment Ambient temperature range Storage temperature Degree of protection Electromagnetic compatibility Relative humidity Liquiline To Go CYM290-10 to +55 C (+14 to +130 F) Liquiline To Go CYM291-10 to +40 C (+14 to +104 F) T3 Duracell MN1500-10 to +50 C (+14... +122 F) T4 Energizer E91, Power One 4106 and Panasonic Pro Power LR6-25 to +70 C (-13 to +158 F) IP66/67 with pressure compensation DIN EN 61326-1 (general requirements) Interference emission: Class B (residential environments) Interference immunity: Class A (industrial environments) DIN EN 61326-2-3 (special requirements for transmitters) 0 to 95 %, condensation permitted for short periods Mechanical construction Dimensions Approx. (132 x 156 x 30) mm 132.3 (5.20) 129.7 (5.11) 30.5 (1.20) 29.3 (1.15) 158.5 (6.24) 155.6 (6.13) 4 Dimensions in mm/inch A0030659 Weight Materials Approx. 500 g (1.1 lbs) PA12 GF30 (silver-gray RAL 7001) + TPE (black) 6 Endress+Hauser

Operability Operating concept Display Software Clear menu navigation with graphic symbols and detailed plain-text operating instructions Languages German, English, French, Spanish, Italian, Portuguese, Russian Displayable data: Manufacturer, sensor type, serial number, zero point, slope, date of calibration Status indicators For battery charge state, data logger Keypad [on/off ], [meas], [enter], 2 soft keys with context-dependent functions Messages Displays all the error and device messages currently pending as well as complementary help text. MemoLog (Memosens only) Individually displays the calibration protocols saved. You have the option of deleting individual entries or all entries. The following is displayed: Sensor type Manufacturer Calibration date Serial number Zero point Slope Utilization data Measuring point (TAG) Certificates and approvals mark Ex approval Declaration of Conformity The product meets the requirements of the harmonized European standards. As such, it complies with the legal specifications of the EU directives. The manufacturer confirms successful testing of the product by affixing to it the mark. IECEx Ex ia IIC T4/T3 Ga ATEX II 1 G Ex ia IIC T4/T3 Ga Endress+Hauser 7

Ordering information Product page Product Configurator www.endress.com/cym290 www.endress.com/cym291 On the product page there is a "Configuration" button to the right of the product image. 1. Click this button. The Configurator opens in a separate window. 2. Select all the options to configure the device in line with your requirements. In this way, you receive a valid and complete order code for the device. 3. Export the order code as a PDF or Excel file. To do so, click the appropriate button on the right above the selection window. For many products you also have the option of downloading CAD or 2D drawings of the selected product version. To do so, click the "CAD" tab and select the desired file type using dropdown lists. Scope of delivery The scope of delivery comprises: Measuring device including 4 batteries (AA) and pre-mounted holder Carry strap Data storage medium with detailed operating instructions USB cable, 1.5 m Safety instructions Brief Operating Instructions in multiple languages 8 Endress+Hauser

Accessories The following are the most important accessories available at the time this documentation was issued. For accessories not listed here, please contact your service or sales office. Kits Carrying case Suitable for the safe transportation of the Liquiline To Go CYM290 and CYM291 Order No. 71296856 5 Liquiline To Go carrying case Adapter sleeves Sleeves for PG adapter 6 pieces in the set Order No. 71279016 Sensor holder / Watering cap Watertight 5 pieces in the set Order No. 71281544 Sensor cable Memosens laboratory cable CYK20 For digital sensors with Memosens technology Product Configurator on the product page: www.endress.com/cyk20 Memosens laboratory cable ATEX CYK20 For digital sensors with Memosens technology in the hazardous area Product Configurator on the product page: www.endress.com/cyk20 Order version: BAB1C2 Memosens laboratory cable IECEx CYK20 For digital sensors with Memosens technology in the IECEx area Product Configurator on the product page: www.endress.com/cyk20 Order version: IABIC2 Endress+Hauser 9

Sensors ORP sensors Orbisint CPS11D ph electrode for process technology Optional SIL version for connecting to SIL transmitter With dirt-repellent PTFE diaphragm Product Configurator on the product page: www.endress.com/cps11d Technical Information TI00028C Orbisint CPS12D ORP sensor for process technology Product Configurator on the product page: www.endress.com/cps12d Technical Information TI00367C Memosens CPS16D Combined ph/orp sensor for process technology With dirt-repellent PTFE diaphragm With Memosens technology Product Configurator on the product page: www.endress.com/cps16d Technical Information TI00503C Memosens CPS31D ph electrode with gel-filled reference system with ceramic diaphragm Product Configurator on the product page: www.endress.com/cps31d Technical Information TI00030C Ceraliquid CPS41D ph electrode with ceramic junction and KCl liquid electrolyte Product Configurator on the product page: www.endress.com/cps41d Technical Information TI00079C Ceraliquid CPS42D ORP electrode with ceramic junction and KCl liquid electrolyte Product Configurator on the product page: www.endress.com/cps42d Technical Information TI00373C Ceragel CPS71D ph electrode with reference system including ion trap Product Configurator on the product page: www.endress.com/cps71d Technical Information TI00245C Ceragel CPS72D ORP electrode with reference system including ion trap Product Configurator on the product page: www.endress.com/cps72d Technical Information TI00374C Memosens CPS76D Combined ph/orp sensor for process technology Hygienic and sterile applications With Memosens technology Product Configurator on the product page: www.endress.com/cps76d Technical Information TI00506C Orbipore CPS91D ph electrode with open aperture for media with high dirt load Product Configurator on the product page: www.endress.com/cps91d Technical Information TI00375C 10 Endress+Hauser

Orbipore CPS92D ORP electrode with open aperture for media with high dirt load Product Configurator on the product page: www.endress.com/cps92d Technical Information TI00435C Memosens CPS96D Combined ph/orp sensor for chemical processes With poison-resistant reference with ion trap With Memosens technology Product Configurator on the product page: www.endress.com/cps96d Technical Information TI00507C Ceramax CPS341D ph electrode with ph-sensitive enamel Meets highest demands of measuring accuracy, pressure, temperature, sterility and durability Product Configurator on the product page: www.endress.com/cps341d Technical Information TI00468C Orbipac CPF81D Compact ph sensor for installation or immersion operation In industrial water and wastewater Product Configurator on the product page: www.endress.com/cpf81d Technical Information TI00191C Orbipac CPF82D Compact ORP sensor for installation or immersion operation in process water and wastewater Product Configurator on the product page: www.endress.com/cpf82d Technical Information TI00191C ph ISFET sensors Tophit CPS441D Sterilizable ISFET sensor for low-conductivity media Liquid KCl electrolyte Product Configurator on the product page: www.endress.com/cps441d Technical Information TI00352C Orbipac CPS51 ph electrode including and excluding integrated NTC temperature sensor For handheld and laboratory measuring devices Fixed cable 1.5 m / DIN plug Order code CPS51 excluding temperature sensor : 1EK2FDA Order code CPS51 including temperature sensor : 7EK2FDA Technical Information TI031C Orbipac CPS52 ORP combined electrode For handheld and laboratory measuring devices Standard plug-in head Order code CPS52: OPK2FDA Can be connected via a standard electrode plug-in head or a DIN connecting plug Technical Information TI031C Tophit CPS471D Sterilizable and autoclavable ISFET sensor for food and pharmaceutics, process engineering Water treatment and biotechnology Product Configurator on the product page: www.endress.com/cps471d Technical Information TI00283C Endress+Hauser 11

Tophit CPS491D ISFET sensor with open aperture for media with high dirt load Product Configurator on the product page: www.endress.com/cps491d Technical Information TI00377C Conductivity sensors with conductive measurement of conductivity Condumax CLS15D Conductive conductivity sensor For pure water applications, ultrapure water applications and Ex applications Product Configurator on the product page: www.endress.com/cls15d Technical Information TI00109C Condumax CLS16D Hygienic, conductive conductivity sensor For pure water applications, ultrapure water applications and Ex applications With EHEDG and 3A approval Product Configurator on the product page: www.endress.com/cls16d Technical Information TI00227C Condumax CLS21D Two-electrode sensor in plug-in head version version Product Configurator on the product page: www.endress.com/cls21d Technical Information TI00085C Oxygen sensors Oxymax COS22D Sterilizable sensor for dissolved oxygen With Memosens technology or as an analog sensor Product Configurator on the product page: www.endress.com/cos22d Technical Information TI00446C Buffer solutions (ph) Conductivity calibration solutions High-quality buffer solutions from Endress+Hauser - CPY20 The secondary buffer solutions have been referenced to primary reference material of the PTB (German Federal Physico-technical Institute) or to standard reference material of NIST (National Institute of Standards and Technology) according to DIN 19266 by a laboratory accredited by the DAkkS (German accreditation body) according to DIN 17025. Product Configurator on the product page: www.endress.com/cpy20 Conductivity calibration solutions CLY11 Precision solutions referenced to SRM (Standard Reference Material) by NIST for qualified calibration of conductivity measuring systems in accordance with ISO 9000 CLY11-A, 74 μs/cm (reference temperature 25 C (77 F)), 500 ml (16.9 fl.oz) Order No. 50081902 CLY11-B, 149.6 μs/cm (reference temperature 25 C (77 F)), 500 ml (16.9 fl.oz) Order No. 50081903 CLY11-C, 1.406 ms/cm (reference temperature 25 C (77 F)), 500 ml (16.9 fl.oz) Order No. 50081904 CLY11-D, 12.64 ms/cm (reference temperature 25 C (77 F)), 500 ml (16.9 fl.oz) Order No. 50081905 CLY11-E, 107.00 ms/cm (reference temperature 25 C (77 F)), 500 ml (16.9 fl.oz) Order No. 50081906 Technical Information TI00162C 12 Endress+Hauser

www.addresses.endress.com