TM-3100 Series Room Temperature Sensor

Similar documents
HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance

A99B Series Temperature Sensors

W43A Humidistat. Features and Benefits

ER65 - Mini Rack Controller Electronic Refrigeration Line

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

TEC1100 Series Thermostats

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

ER52 - Evaporator Controller

Series A36 3- and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

Johnson Controls Fan Coil Units and Direct Digital Controls

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications

TEC2100 Series Networked Thermostats

Surface-Mounted NS Series Network Sensors without LCD

Series A28 Two stage Thermostats. Feature and Benefits

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

WT-4000 Series Pneumatic-to-Direct Digital Control (DDC)

TEC210x-2 Series Networked Thermostats

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

P266 Series Single-Phase Condenser Fan Speed Control

ACT2-CS Convenience Store Controller

NS Series Network Sensors

Facility Explorer One-to-One Wireless Room Sensing System

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Vertical Wallbox-Mounted or Surface-Mounted NS Series Network Sensors with LCD

Location Requirements

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

T500 Series Non-Programmable Thermostats

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

GCS Multipoint Carbon Dioxide Gas Concentration Sampler

GETTING STARTED GUIDE NI AI, ±29.4 mv/v, 24 Bit, 10 ks/s/ch Simultaneous, 350 Ω Quarter-Bridge Completion

F261 Series Fluid Flow Switches

GETTING STARTED GUIDE NI AI/8 AO/4 DIO, 0 V to 5 V, 12 Bit, 20 ks/s Aggregate

Room Temperature Sensors

Room Temperature Controller

A19, A28 Series Thermostats for Agricultural Buildings

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

CD-Px Series Duct Mount CO 2 Transmitters

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

MR3CCUHV Temperature/Defrost Control

A-4400 Series Refrigerated Air Dryers for Pneumatic Control Systems

Metasys System Extended Architecture Smoke Control UL 864 UUKL Compliance

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

DMFPM-2R MULTIFUNCTIONAL

Installation Guide

NS Series Network Sensors

QPM21 Series Duct CO 2 and Air Quality Sensors

Pre-programmed room controller with communication

RSMFM-2R MULTIFUNCTIONAL

Room controller. RC is a room controller from the Regio Mini series intended to control heating and cooling in a single zone.

Weekly Testing of Dedicated Smoke Control Dampers - Metasys System Extended Architecture

RLD-H10P Refrigerant Leak Detector

RLD-H10G Refrigerant Leak Detectors

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Weekly Testing of Dedicated Stairwell Pressurization Fans- Metasys System Extended Architecture Code No. LIT

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

I ntroduction. Series F61. Liquid Flow Switches. Feature and Benefits

TC-9102 Applications

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Pre-programmed room controller with communication and hidden setpoint

Room controllers with manual forced ventilation function

NS Series Network Sensors

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

Powers TM Controls ET 134 Line Voltage Room Thermostats

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

Room Temperature Sensors

FTW04. Application. Types Available. Security Advice Caution. Surface mounting room sensor for relative humidity and temperature.

Series F61. Liquid Flow Switches. Feature and Benefits. T-body and Pipe-insert types available

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Duct Air Quality Sensors

M7100 Pressure Transducer

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

TEC Networked Multi-Stage Thermostat

INSTRUCTIONS REHAU SILENT DIAL THERMOSTAT #

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

QFM21... Duct sensors. Symaro. for relative humidity and temperature

GREEN LEAF PROGRAMMABLE THERMOSTAT FOR ELECTRICAL FLOOR HEATING INSTALLATION INSTRUCTIONS. EN-RaychemGreenLeaf-IM-EU0209 THERMAL BUILDING SOLUTIONS

for relative humidity and temperature

Room thermostat with 24-hour time switch and large LCD

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

GETTING STARTED GUIDE. NI 9212 and TB TC, ±78 mv, 24 Bit, 95 S/s/ch Simultaneous, Isothermal Terminal Block

ETAF Series VDC Fan output LCD Fan Coil Thermostat

Pre-programmed room controller with communication

Installation & User Instructions

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

Sensor unit MC2 with analog output for Freon gases and refrigerants

Bionics Instrument. Alarm Handling. Gas Alarm Systems

Proliphix Thermostat Installation Guide. Release 2.0

Room air quality sensors

Transcription:

PB_TM-3100_12 2009 TM-3100 Series Room Temperature Sensor The Johnson Controls TM-3100 Series Room Temperature Sensor provide passive sensing of temperature in HVAC application. The TM-3100 is equipped with a Pt1000 Class A sensing element and provides an output proportional signal to the measured ambient temperature. The TM-3100 Series Room Temperature Sensor is designed for use with the Facility Explorer Series and with the Field Equipment Controller Series. TM-3140-0000 Modern and attractive cover which snaps onto a plug-in mounting base Blends in with room decor. Easy installation. Terminals located on mounting base. Easy wiring and commissioning. All models available with or without Occupancy override button Covers a large number of applications in public buildings and hotels

2 PB_TM-3100_12 2009 Ordering Codes Room Temperature Sensor Ordering Codes Fan Speed Override Occupancy Button Temperature Setpoint Dial Scale Built-in Sensing Element TM-3140-0000 - - - Pt1000 Accessories Ordering Codes TM-1100-8931 TM-9100-8900 Description Plastic Surface Mounting Base - White Special tool for opening enclosure Installation The TM-3100 Series Room Temperature Sensor is designed for wall mounting in the room to be controlled. It should be placed where the temperature is representative of the general room conditions. Cold or warm air draughts, radiant heat and direct sunlight should be avoided. The installation of electrical wiring must conform to local codes and should be carried out by authorized personnel only. Users should ensure that all Johnson Controls products are used safely and without risk to health or property. Remove the base of the module from the cover by inserting the point of the special TM tool into the small hole at the center top of the cover. While pressing down gently, prise the base away from the cover. As the two parts separate, remove the tool and continue to pull the cover away from the base until the cover is free. To reassemble the room command module, place the cover over the lower edge of the base and push the upper part of the cover until it clicks firmly in place. Mounting Dimensions Removing cover form the base TM-3140-0000 dimensions (in mm)

PB_TM-3100_12 2009 3 Direct Surface Mounting Mount the module base on the wall to cover the electrical outlet and secure with at least two screws. Surface Mounting with Mounting Kit (TM-1100-8931) 1. Remove one of the notches (A) with a suitable tool. 2. Mark the position of the holes (B) on the wall and drill holes 5 mm in diameter. Insert plastic plugs into holes. 3. Position and fix the mounting base to the wall using the two long screws (C) provided in the kit. 4. Fix the base of the TM-3100 to the mounting base using the two short screws (D) provided in the kit. Module Base (Dimensions in mm) Surface Mounting Base (Dimensions in mm)

4 PB_TM-3100_12 2009 Wiring Before connecting or disconnecting any wires, ensure that all power supplies have been switched off and all wires are potential-free to prevent equipment damage and avoid electrical shock. Terminations are made on the terminal blocks in the base of the module, which accept up to 1.5 mm 2 wires. Follow the wiring diagrams shown in the figures below. All wiring to the module is at extra low (safe) voltage and must be separated from power line voltage wiring. Do not run wiring close to transformers or high frequency generating equipment. Complete and verify all wiring connections before applying power to the controller to which the module is connected. TM-3100 Room Temperature Sensor Resistance vs Temperature Table The Pt1000 models are equipped with a resistive Pt1000 element according to EN 60751. At 0 C the resistance value is 1000 W. The accuracy is according to Class A. Temperature in C Resistance in W 0 1000 5 1020 10 1039 15 1058 20 1078 25 1097 30 1117 35 1136 40 1155 45 1175 50 1194 20 Pt1000 Sensor To Controller Max 50 m 21 Common (Min. 0.8 mm diameter wire) TM-3140-0000 Wiring

PB_ER54 & ER55_11 2009 5 Technical Specifications Product TM-3140-0000 Ambient Operating Conditions 0 to 50 C 10 to 90% RH, non condensing Ambient Storage Conditions -20 to 70 C 10 to 90% RH, non condensing Terminations Terminal block in base for 1 x 1.5 mm² (maximum) cable Temperature Sensor Resistive Pt1000 (1000 Ω at 0 C) Accuracy EN 60751, class A Mounting Direct surface mount, plastic base for surface mount with wiring conduits Materials Enclosure Base ABS+PC; self extinguishing HB UL 94 Colours Enclosure Base RAL9016 (GE86280 ) Protection Class Enclosure IP30 (EN 60529) Dimensions (H x W x S) 80 mm x 80 mm x 32 mm Shipping Weight 0.15 kg Conformity EMC Directive 2004/108/EC EN-61000-6-3 EN-61000-6-2 The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Building Efficiency Headquarters: Milwaukee, Wisconsin, USA Branch Officies: Principal Cities World-wide Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2010 Johnson Controls, Inc. Published in Europe www.johnsoncontrols.com