Sysmac Library for NJ/NX Machine Automation Controller SYSMAC-XR007 Temperature Control Library Improve product quality and reduce cycle time with optimal temperature control. 1 2 3 Uneven heating of a hotplate causes differences in product temperature. This reduces the yield. In PID control, it takes time to increase the temperature while avoiding overshooting. Placing objects (disturbance) lowers the heater temperature, which results in poor product quality. It takes time to raise the temperature again after the disturbance in PID control. Temperature Control Library offers solution! The Temperature Uniformity Filter Function Block reduces in-furnace temperature variations or maintains different heater temperatures. The Direct Manipulated Variable Control Function Block quickly raises the temperature while reducing overshooting or reduces the drop in temperature to stabilize the heater temperature immediately. Four types of temperature control Temperature uniformity Temperature gradient Reduces temperature variations Controls temperature distribution Temperature Uniformity Filter Function Block Rapid temperature increase Disturbance suppression Quickly increases temperature while reducing overshooting Reduces temperature fluctuations caused by disturbance to stabilize temperature immediately Direct Manipulated Variable Control Function Block
System configuration NJ/NX Machine Automation Controller NX Analog Input Unit NX Digital Output Unit Temperature sensors Objects Temperature Uniformity Filter Function Block Calculates the set points corrected for each separate heater using the set points and process values. Direct Manipulated Variable Control Function Block Directly manipulates the manipulated variable to follow the set point. This increases the performance of following the set point. Hotplate Applications Temperature uniformity/temperature gradient Process value The temperature of where an object is placed drops. This causes differences in the hotplate temperature. As the chemical reaction time of objects varies depending on temperature, the yield is reduced. Temperature uniformity/gradient can be achieved by controlling temperatures based on the set points corrected by the Temperature Uniformity Filter Function Block. Set point 1 Set point 2 Process values Temperature Uniformity Filter Function Block Corrected set point Corrected set point PIDAT instruction PIDAT instruction Process value Temperature varies depending on heater. Manipulated variable Manipulated variable 1 2 Temperature uniformity Reduces temperature variations and makes surface temperature uniform Temperature gradient Controls temperatures to produce a specified temperature distribution Temperature variations are reduced by temperature uniformity.
Rapid temperature increase Reduce the time to raise the temperature of a reflow oven without overshooting to Improve productivity. PID control can avoid overshooting, but it takes time to increase the temperature. The Direct Manipulated Variable Control Function Block controls manipulated variables when the temperature is increased. Then the control is changed to PID control. This control enables a rapid temperature increase while suppressing the overshooting. Time to reach the set point Control using the Direct Manipulated Variable Control Function Block PID control Disturbance suppression Disturbance, such as placing products on a packaging machine, lowers the heater temperature, resulting in heat sealing error. Once disturbance occurs, it takes some time before the heater temperature is stabilized. The Direct Manipulated Variable Control Function Block controls manipulated variables when packaging starts. Then the control is changed to PID control. This control reduces the drop in temperature to stabilize the heater temperature immediately. Film Product Set point Heat sealing Start packaging Sealing error Sealing errors occur below this temperature Stop packaging Without disturbance suppression With disturbance suppression using Direct Manipulated Variable Control Function Block
Compatible Models Name Machine Automation Controller NJ/NX CPU Unit Model NX701-/ NJ101- NJ501-/ NJ301- SYSMAC-SE2 Version Version 1.10 or later Version 1.02 or later Version 1.14 or higher Function Block (FB) Specifications Name FB name Description Temperature Uniformity Filter TempUniformityFilter Calculates the set points suitable for each separate heater. Direct Manipulated Variable Control DirectPowerControl Directly manipulates the manipulated variable to follow the set point in temperature control. You can use it to increase the performance of following the set point. Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products. EtherCAT is registered trademark and patented technology, licensed by Beckho Automation GmbH, Germany. Other company names and product names in this document are the trademarks or registered trademarks of their respective companies. Note: Do not use this document to operate the Unit.
OMRON AUTOMATION AND SAFETY THE AMERICAS HEADQUARTERS Chicago, IL USA 847.843.7900 800.556.6766 www.omron247.com OMRON CANADA, INC. HEAD OFFICE Toronto, ON, Canada 416.286.6465 866.986.6766 www.omron247.com OMRON ELECTRONICS DE MEXICO HEAD OFFICE México DF 52.55.59.01.43.00 01-800-226-6766 mela@omron.com OMRON ELECTRONICS DE MEXICO SALES OFFICE Apodaca, N.L. 52.81.11.56.99.20 01-800-226-6766 mela@omron.com OMRON ARGENTINA SALES OFFICE Cono Sur 54.11.4783.5300 OMRON CHILE SALES OFFICE Santiago 56.9.9917.3920 OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 OMRON ELETRÔNICA DO BRASIL LTDA HEAD OFFICE São Paulo, SP, Brasil 55.11.2101.6300 www.omron.com.br OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. +31 (0) 23 568 13 00 www.industrial.omron.eu Authorized Distributor: Automation Control Systems Machine Automation Controllers (MAC) Programmable Controllers (PLC) Operator interfaces (HMI) Distributed I/O Software Drives & Motion Controls Servo & AC Drives Motion Controllers & Encoders Temperature & Process Controllers Single and Multi-loop Controllers Sensors & Vision Proximity Sensors Photoelectric Sensors Fiber-Optic Sensors Amplified Photomicrosensors Measurement Sensors Ultrasonic Sensors Vision Sensors Industrial Components RFID/Code Readers Relays Pushbuttons & Indicators Limit and Basic Switches Timers Counters Metering Devices Power Supplies Safety Laser Scanners Safety Mats Edges and Bumpers Programmable Safety Controllers Light Curtains Safety Relays Safety Interlock Switches P100-E1-01 11/15 Note: Specifications are subject to change. 2015 Omron Electronics LLC Printed in U.S.A. Printed on recycled paper.