LZP-2 ZONE CONTROL PANEL

Similar documents
Safety & Installation Instructions

Safety & Installation Instructions

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

Model 1750A/ 1770A Dehumidifier Installation Instructions

TZ-4 TotalZone Zone Control Panel

H32 Uni- Zone Model H32

SmartZone TM System Manual

Digi-Zone Model MDP3 Ver.04

Installation and Operation Manual

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

Installation Instructions

Safety & Installation Instructions

Model 8120 and 8126 Safety & Installation Instructions

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Safety, Installation, and Operation Manual

Installation & Operation Instructions

Heat Pump Defrost Board Replacement Kit

Digi-Zone. Installation and Operating Instructions. Model MDP3. Controlling Your Comfort Room By Room

B24 SERVICE UNIT INFORMATION B24 SERIES ADD-ON BLOWER ECB24 SERIES ELECTRIC HEAT

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Installation & Operation Instructions

WARNING IMPORTANT. iharmony Zoning System CONTROLS KITS AND ACCESSORIES. Installation Instructions for the iharmony Zoning System (10C16)

Smart Temp. Model

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Table of Contents. Discharge Air Upper Limit and Differential Temp General Information... 8

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Zoning System Design Manual

T-32-TS Touchscreen Thermostat. Installation Manual

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

T8600D Chronotherm IV Deluxe Programmable Thermostats

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

Model 1870 & 1870W Dehumidifier Installation Instructions

Specifications and Performance

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Installation Instructions

INSTALLATION AND OPERATION MANUAL ANALOG ELECTRONIC CONTROLS VAV TERMINAL UNITS

Specifications and Performance

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

Model DEHXXCDA1070 & DEHXXCDA1095 Dehumidifier Installation Instructions

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

Installation Instructions Owner s Manual

Operator: Save these instructions for future use!

Installation, Operation and Service Manual

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3011C Non-Programmable Thermostat. Table of Contents. L3011C Thermostat

Safety and Installation Instructions Model 1700

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

Water Source Heat Pump Module Technical Guide

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

Commercial Touchscreen Thermostat

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Bulletin (Jan 2011) And User s Guide

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities

INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

Emerson Blue Easy Set 1H/1C

FAN POWERED VAV TERMINALS

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

L SERIES UNITS 504,520M. 10/2001 Supersedes 504,413M

S1-CVD070T01A / S1-CVD095T01A Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION

ATP21W02 CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS REMOVING OLD THERMOSTAT 2 THERMOSTAT DETAILS

Zone Control Panels. ZoZ one Product Catalog Page 3 ED3 SMZ4SW SMZAC SMZ3SW JTZHP

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

Installer Guide. WARNING Important Safety Information. 1 Specifications

INSTALLATION INSTRUCTIONS

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

Deluxe Programmable Thermostats

USERS INFORMATION MANUAL

I N STALL AT ION & O PERATIO N MANUAL TA 1/ TA 2 CONTROLLER. Redefine your comfort zone.

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation and Operation. Tracer ZN521 Zone Controller CNT-SVX07C-EN

INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH MC97AE-1

ELECTRONIC COMMUNICATING THERMOSTAT

No fan function in heat mode. Fan ON continuously. Indicates incorrect room temperature

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

R11C R12C R21C R22C/H R23C/H R24C/H

OWNER'S MANUAL T0140. Contents Page #

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

I/O ZONE 560/583 USERS GUIDE

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

Transcription:

2004 Lennox Industries Inc. Dallas, Texas, USA ZONING SYSTEM 504,926M 5/2004 Litho U.S.A. LZP-2 ZONE CONTROL PANEL INSTALLATION INSTRUCTIONS FOR ZONE CONTROL PANELS USED WITH LENNOX HEATING AND COOLING EQUIPMENT Shipping & Packing List Package 1 of 1 contains the following: (1) Model LZP-2 Zone Control Panel (1) Model 88K38 Temperature Sensor (1) Installation Instructions (1) Owners Manual (1) Warranty Card Required Components (ordered separately): 24 VAC Transformer The size of the transformer needed is determined by the total power requirements for the control panel, thermostats and dampers. The control panel and thermostats together require 10VA. The dampers require 10VA each. The size of the transformer will depend on the greatest number of dampers that could be energized at any given time. NOTE When power closed/spring open dampers are used, at least one zone s dampers will not be energized during a call for heating or cooling. TABLE 1 TRANSFORMERS Part Number Size Voltage Description 10P17 40VA 120/208/240V-24V 10P87 50VA 120/208/240V-24V 12P61 75VA 120/208/240V-24V 83P74 4" Square Electrical Box Thermostats single-stage, electronic, 24-volt heat/cool thermostats which include a C (24VAC common) terminal. Do not use mechanical or power robbing thermostats. Dampers 2 or 3-wire, 24-volt dampers required. 2-wire, power closed/spring open preferred. FIGURE 1 LENNOX MODEL LZP-2 CONTROL PANEL LAYOUT Page 1

Application Two zones Single-stage electric or gas furnace Single-stage air conditioner Multi-stage equipment can be used provided that it stages on it s own internal controls Not applicable to heat pump systems Features Adjustable high and low discharge air temperature limits ON/OFF duct air purge control LED indicators for outputs Time Delay Override 2 or 3-wire damper compatibility Installation The above illustration shows a typical two zone control system. WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Install the control panel indoors only. Do not install the control panel where the temperature will exceed 140 F or will drop below 32 F. Do not install the control panel on foundation walls, HVAC equipment or duct system where moisture may condense on the enclosure. Do not install the control panel in a room where it will be exposed to elevated humidity levels such as a laundry room. 1. Remove the cover. Replace the cover when installation is complete. 2. There are eight slots on the base of the enclosure (see Figure 2). 3. Use #8 screws (field supplied) to install the base. CAUTION Electrostatic discharge can damage the control. Touch a grounded metal object before touching the circuit board, and then only touch the circuit board on the edges when handling. W G Y RC RH R C DAS EQUIP. 24VAC J1 K3 J3 J4 D1 D3 D5 W G Y K1 RV1 C5 D13 D14 D12 R17 K4 Q1 C8 D15 R20 D17 C10 U2 RV4 RV5 TDO Y1 F1 SPARE FUSE U6 C12 F2 C16 C15 MAIN FUSE RV6 GAS R43 R44 C18 R45 PURGE LENNOX LZP-2 HT-160 X3785 REV. 1 CL-45 SW1 C9 C7 R19 ELECT. 140 40 R18 U3 R21 NoPURGE 24VDC TP4 D11 C1 R37 C19 U1 C3 R38 C20 GND NORMAL FLASHING R10 U4 R39 C21 5VDC D7 C13 R40 C22 U5 D4 D8 D9 D20 R30 R7 R12 R11 D18 R35 R46 R1 R8 D22 D10 R22 D19 R23 D23 R36 R41 R42 R47 R2 C6 D2 K2 R28 K5 R13 C4 C14 C17 C2 C11 R14 R24 R31 R3 D6 D21 R15 R4 R25 R32 R16 R5 R26 R33 R9 R29 R6 RV2 R27 R34 RV7 RV8 RV3 D16 D24 ZONE 1 J2 DamperZ1 ZONE 2 J5 DamperZ2 Y G R NO NC C W Y G R NO NC C W (8) Mounting Slots FIGURE 2 CONTROL PANEL AND ENCLOSURE BASE Page 2

Installation (continued) 4. Install and Wire the Discharge Air Temperature Sensor CAUTION As with any mechanical equipment, personal injury can result from contact with sharp sheet metal edges. Be careful when you handle this equipment. CAUTION Before attempting to perform any service or maintenance, turn the electrical power to unit OFF at disconnect switch. 15" D/3 W D FRONT The tip of the sensor must be located in a region of fully mixed supply of air before the take-offs (not in a dead air space) in order for the system to work correctly. a. Wire discharge air temperature probe to control panel using thermostat wire. Note that the temperature sensor is not polarity sensitive. b. Be sure that the tip of the sensor is located at least 15 inches downstream from the leaving air side of the evaporator in the discharge plenum, and 1/3 of the depth (D/3) of the plenum (D) from the front of the plenum (the front is the side with the furnace or CB access doors), and centered side to side. Move the adjustable bracket along the length of the discharge air sensor to achieve proper sensor tip location (tip of sensor to be located at W 2). The sensor can be inserted from any side of the plenum, as long as the tip of the sensor is in the correct position. See Figure 3. FIGURE 3 DISCHARGE AIR SENSOR LOCATION IMPORTANT: The discharge air sensor is required. If a short or open circuit is detected between the Plenum Sensor terminals, the control panel will only respond to Zone 1 and the dampers will stay in the open position. Page 3

Installation (continued) 5. Install the required transformer selected from Table 1 DO NOT USE the HVAC equipment transformer to power the control panel. Refer to the instructions provided with the transformer. 18 AWG thermostat wire minimum recommended. Sizing the Transformer: The system requires approximately 10 VA for the control panel and thermostats and 10 VA for each damper. The size of the transformer will depend on the greatest number of dampers that could be energized at any given time (at least one zone s dampers will not be energized during a heating or cooling call when using power close, spring open dampers). The size of the transformer must not exceed 75VA. If the value is greater than 75VA, some dampers will need to be powered by a separate transformer refer to Field Wiring Damper Diagram 2 on page 6. For instance, if you have 3 dampers, then you would require 10VA for the system, 20VA (10VA X 2) for the dampers for a total of 30VA, so catalog number 10P17 would be an adequate transformer size at 40VA. TABLE 1 TRANSFORMERS Part Number Size Voltage Description 10P17 40VA 120/208/240V-24V 10P87 50VA 120/208/240V-24V 12P61 75VA 120/208/240V-24V 83P74 4" Square Electrical Box The transformers listed in this chart include a plate mount for a 4" square electrical box. 6. Install the thermostats. Refer to the instructions provided with the thermostat. Any 24-volt electronic thermostat with a C (24 VAC common) terminal can be used. Power robbing thermostats can cause unintended operation DO NOT use mechanical or power robbing thermostats. Table 2 lists the required terminals and recommended Lennox thermostats: 18 AWG thermostat wire minimum recommended. TABLE 2 THERMOSTAT REQUIREMENTS Recommended Type Terminals Thermostat HEAT/COOL R, C, W, Y, G Thermostat Terminal R C W Y G SignatureStat 1H/1C (51M26) Elite 1H/1C (49M55) Function 24 VAC Hot 24 VAC Common Heat Cool Fan 7. Install the dampers. Refer to the instructions provided with the damper. 18 AWG thermostat wire minimum recommended. Page 4

Bypass Damper Sizing When fewer than the maximum number of zones are calling for heating or cooling, an excess volume of air is delivered, and because of the excess air, an excess amount of static pressure is produced as well. Zone systems often require a bypass duct to relieve this pressure. A properly sized barometric bypass damper must be installed in the bypass duct which is run between the supply and return air duct systems (see Figure 4). The barometric damper and the bypass duct must be sized to accommodate the excess static pressure from the supply duct. The bypass tap in the return air duct must be at least 6 ft. from the furnace /air handler to ensure that the hot or cold air coming off of the plenum has time to mix with the return air before it passes through the air handler again. The provided discharge air sensor will prevent any damage to the equipment from overheating or coil freeze-up by interrupting the HVAC equipment. The bypass damper and duct should be sized to handle the excess pressure created when the smallest zone is operating alone (worst case). To size the bypass damper, subtract the total air volume capacity of the smallest zone from the total air volume of the system. Example: Total System air volume: 2000 cfm Air volume of smallest zone: 600 cfm Bypass requirement: 2000-600 = 1400 cfm In this example, the bypass duct should be sized to handle the 1400 cfm excess pressure created when only the smallest zone has a demand. For bypass damper air volume capacities, see Table 3. Round TABLE 3 Rectangular 8 in. dia. 400 cfm 12 x 8 1000 cfm 10 in. dia. 750 cfm 12 x 10 1200 cfm 12 in. dia. 1200 cfm 12 x 12 1400 cfm 14 in. dia. 1800 cfm 20 x 8 1600 cfm 16 in. dia. 2400 cfm 20 x 10 2000 cfm 20 x 12 3000 cfm Refer to the parts and supplies catalog for information on available barometric bypass dampers. ZONE 1 THERMOSTAT ZONE 1 BYPASS DAMPER BYPASS DUCT ZONE DAMPER SUPPLY AIR HEATING/ COOLING UNIT RETURN AIR ZONE DAMPER DISCHARGE AIR SENSOR 6 ft. (1.8 m) ZONE 2 THERMOSTAT ZONE 2 TRANSFORMER FOR DAMPERS, PANEL AND THERMOSTATS ZONE CONTROL PANEL FIGURE 4 BYPASS DAMPER INSTALLATION Page 5

Field Wiring DIAGRAM 1 FIELD WIRING DIAGRAM 2 DAMPER WIRING WITH SEPARATE TRANSFORMER Page 6

Pin Jumper Settings (see Figure 5) DISCHARGE AIR SENSOR HT-140/160: This jumper controls the temperature at which the heating equipment will cut out to prevent overheating. For a high limit temperature of 140 F, move the jumper to the 140 position. For a high limit temperature of 160 F, leave the jumper in the 160 position. FIGURE 5 PIN JUMPER SETTINGS ELECTRIC/GAS: If electric heat is to be used, move the jumper to the ELECT position. This will turn on the fan (G output terminal) with a heat call (W output terminal). If the jumper is in the GAS position, it is assumed that the heating equipment will control the fan operation. NO PURGE / PURGE: If the NO PURGE / PURGE jumper is moved to the PURGE purge position, the G terminal will remain energized for a one minute purge delay following the completion of a cooling call. If the jumper is moved to the NO PURGE position, the G terminal will de-energize immediately following the completion of a cooling call. The NO PURGE setting is designed for use with systems where the furnace or air handler has a built in fan purge. The NO PURGE damper hold time is longer than the PURGE setting due to the Lennox furnaces installer settable maximum blower off delay of 3 minutes. The following chart details the zone panel outputs and damper hold times when a heating or cooling call is satisfied: IMPORTANT: The temperature sensor is required. If a short or open circuit is detected between the Discharge Air Sensor (DAS) terminals, the control panel will only respond to Zone 1 and the dampers will not close. DISCHARGE AIR SENSOR CL-45/40: This jumper controls the temperature at which the cooling equipment will cut out to prevent freezing the indoor coil. For a low limit temperature of 45 F, leave the jumper in the 45 position. For a low limit temperature of 40 F, move the jumper to the 40 position. To maintain optimum operation, it is recommended to leave this setting at 45. Jumper Settings Mode Purge No Purge Output Damper Hold Time Output Damper Hold Time Heat/Cool Cooling G 1 1 minute No G, 3-1/2 minutes Gas Heating No G 1 minute No G, 3-1/2 minutes Heat/Cool Cooling G 1 1 minute No G, 3-1/2 minutes Elect. Heating G 1 1 minute No G, 3-1/2 minutes 1 The G terminal will remain energized for 1 minute. LEDs POWER Blinks during normal operation. Starts to blink approximately 6 seconds after power up. G, Y and W Lights when respective equipment outputs are energized. The W LED will flash if the heating high temperature limit has been reached. The Y LED will flash if the cooling low temperature limit has been reached. ZONE 1 Damper and ZONE 2 Damper Lights when the Normally Open (NO) damper terminal for that zone is energized (i.e. LEDs show which zones are NOT receiving conditioning when the HVAC equipment is operating). Page 7

Sequence of Operation A Time Delay Override (TDO) button is available on the control panel to speed up the internal timer by a factor of 60 for system checkout. One second of holding down the button relates to one minute of speed up time in the control. HEATING AND COOLING EQUIPMENT OPERATION Heating Operation When a zone makes a call for Heat, the W output terminal will energize. The G terminal will also energize if the ELECTRIC/GAS jumper is in the ELECT position. The W terminal de-energizes when (1) all zones stop calling for Heat, (2) the call has exceeded the heat/cool changeover time limit while a cooling call exists or (3) the call is interrupted by the high limit setting. When the W terminal is de-energized, a minimum off time delay of 4 minutes must elapse before it can be energized again. Fan Purge Time Delay If the ELECTRIC/GAS jumper is in the ELECT position and the PURGE/NO PURGE jumper is in the PURGE position, the G terminal will remain energized for one minute after the W terminal is de-energized. The NO PURGE setting is the preferred purge control setting for Lennox equipment. Lennox equipment includes controls which sequence the indoor fan off after a call for heat has been satisfied. If the ELECTRIC/GAS jumper is set in the GAS position, the G terminal does not turn on during purge regardless of the position of the PURGE or NO PURGE switch. Lennox furnaces will control the purge though the furnace control board cool down feature. The cool down time is often adjustable at the furnace control board up to 3.5 minutes. NO PURGE is the preferred method of purge when this zone panel is applied to Lennox equipment. Cooling Operation When a zone makes a call for Cooling, the Y and G terminals will energize. The Y terminal de-energizes when (1) all zones stop calling for Cooling, (2) the call has exceeded the heat/cool changeover time limit while a heat call exists or (3) the call is interrupted by the low limit temperature setting. When the Y terminal is deenergized, a minimum off time delay of 4 minutes must elapse before it can be energized again. Fan Purge Time Delay If the PURGE/NO PURGE jumper is in the PURGE position, the G terminal will remain energized for one minute after the Y terminal is de-energized. If the jumper is in the NO PURGE position, the G terminal will de-energize immediately. Heat/Cool Changeover: When a call for heating or cooling exists and an opposing call is made from another zone, a 20 minute timer is activated. If the original call is not satisfied within that 20-minute time period, the call will be interrupted, turning the equipment off and allowing for the normal fan purge cycle and minimum equipment off time. The opposing call will then be answered. After 20 minutes, if the original call still exists, the opposing call will be interrupted and the original call can once again be recognized. High/Low Limit Temperature: The high/low limit temperature settings are designed to prevent the heat exchanger from overheating or the cooling coil from freezing. The temperature sensor in the supply duct senses the discharge air temperature and interrupts the heating/cooling equipment (depending on the Heat and Cool temperatures set on the control panel) before overheating/freezing occurs. When a heating/cooling call is interrupted by the high/low temperature limit, the zone control panel turns the equipment off and energizes the G terminal (if not already energized). The W or Y LED on the control panel will flash during a high/low limit temperature interrupt. Once the temperature drops/rises 10 F and the minimum off time has expired, the equipment is turned back on if the call for conditioning still exists. The Heating/Cooling LED will stop flashing. IMPORTANT: Should a short or open circuit be detected across the DAS terminals, the zone system will respond only to Zone 1 and the dampers will not energize. Page 8

Sequence of Operation (continued) CONTINUOUS FAN OPERATION A call for Fan from any zone will initiate the G equipment output terminal. The normally open (NO) damper terminal at all zones not calling for continuous fan will be energized. DAMPER OPERATION The NO output will be energized and the NC output will be de-energized for any zone not calling for heating or cooling while the equipment output is energized and during the damper purge time delay. During equipment operation or during the damper purge time delay, should all zones stop calling for heating or cooling, the damper terminals will remain in the position they were in before all zones stopped calling. Damper Purge Time Delay When the Purge/No Purge jumper is at No Purge, the damper purge time delay is 3.5 minutes and begins when the equipment output(s) turn off. NO PURGE is the preferred method of purge control for Lennox furnaces and air conditioners. When the jumper is at Purge, the damper purge time delay is one (1) minute. Page 9

Troubleshooting DETECTING HVAC SYSTEM PROBLEMS Symptom Possible Solution Pressure switch open. Consult condensing unit manual for possible cause. Compressor is off due to internal overload protector. Consult condensing unit manual for possible cause. Condensing unit receiving signal but will not turn on. Condenser control board anti short cycle timer is not yet expired. Most anti short cycle timers are 5 minutes or less, if the unit does not start after 5 minutes consult the condensing unit manual for possible causes. Furnace tripped the primary limit, but the zone panel does not indicate that the discharge air limit has been exceeded. Air handler receiving signal but will not turn on. A high static condition exists. Move the sensor further down stream to sense air that has mixed more thoroughly. Be sure not to place the senor past the take offs. High static pressure must be corrected. Bypass tap is too close to inlet of air handler. Adjust bypass tap in the return air duct so that is further away from the furnace. This will give the air more of a chance to be tempered with room return air before entering the air handler again. Limit on furnace open. Check position of DAS in the plenum and move further down stream if possible. High static condition must be corrected. DAS limit jumper needs to be moved to a lower setting. Trouble shoot air handler see air handler documentation. Page 10

Troubleshooting (continued) DETECTING HEATING, COOLING AND FAN PROBLEMS Symptom Possible Solution Nothing comes on. Heat will not come on. Cooling will not come on. Fan will not come on. Dampers do not position on a call for heating, cooling or fan. Heat, cooling or fan will not come on when the Zone 2 thermostat is calling. Fan immediately comes on with heat call. After a cool call, the fan stops then starts right away only to stop a short while later. Fan is running but no heat, and W LED is blinking. Fan is running but no cooling, and Y LED is blinking. Both the Y and W LEDs are blinking. Page 11 No power to control panel. Green Normal Flashing LED should be blinking, if not apply power to 24VAC inputs of control panel. Check fuse. Single transformer system. Install jumper between RC and RH at HVAC Equipment outputs of control panel. Interlock switch on furnace is open close access doors. Thermostat is not calling for heat. Check voltage at the thermostat W input on the control panel. Zone 2 calling while open or short at DAS inputs is causing control panel to respond only to Zone 1. Thermostat is power robbing or mechanical. Only use line powered electronic thermostat with a C terminal. Single transformer system. Install jumper between RC and RH at HVAC equipment outputs of control panel. Thermostat is not calling for cooling. Check voltage at the thermostat Y input on the control panel. Thermostat could be invoking a timed off delay. Zone 2 calling while open or short at DAS inputs is causing control panel to respond only to Zone 1. Zone panel could be invoking a timed off delay. Thermostat is power robbing or mechanical. Only use line powered electronic thermostat with a C terminal. Check if G is energized at the zone panel. Check if G is energized at the thermostat. Check if G is energized at the air handler. System requires the Discharge Air sensor. If DAS is not installed, only Zone 1 calls will be recognized and dampers will not operate. Disconnect power to the control panel, install the DAS and restore power to the control panel. ELECT/GAS jumper set to ELECT change setting to GAS. HVAC system has built in duct purge. Set PURGE/NO PURGE jumper on control panel to NO PURGE. Discharge air temperature exceeds set limit. Allow discharge air to cool 10 below set limit and allow timed off delay to expire. Discharge air temperature dropped below set limit. Allow discharge air to warm 10 above set limit and allow timed off delay to expire. An open or short in the DAS sensor has been detected. Install or repair the sensor.

Troubleshooting (continued) DETECTING DAMPER PROBLEMS Symptom Possible Solution DAS shorted or open causing the panel to only respond to zone 1 inputs while not closing any dampers. Damper opens when it should be closed. Damper wired incorrectly. Spring open power close dampers should be connected between NO and C terminals. DAS shorted or open causing the panel to only respond Damper will not close. to zone 1 inputs while not closing any dampers. Damper motor faulty. CHECKING THERMOSTAT VOLTAGES Using a digital voltmeter (DVM) measure the AC voltage supplied at the R and C terminals of the Thermostat inputs on the control panel for the zone in question. This voltage should be same as the voltage supplied to the control panel 24VAC terminals. Make a call for heat, cooling or fan. Measure the voltage across the terminal that should be energized (i.e. W for heat, Y for cooling, etc.) and the C terminal. This should be the same voltage as there is between the R and C terminals. Measure the voltage across a terminal that should NOT be energized and the C terminal; this voltage should be zero. DISCHARGE AIR SENSOR CHECKOUT The discharge air sensor is a temperature dependent resistor; the higher the temperature, the lower the resistance. In order to confirm the sensor is working, both sensor leads must be disconnected from the zone panel board. Using a digital voltmeter (DVM) set to read resistance, touch the leads from the sensor to the probes of the DVM. Take care not to create a parallel resistance path through your body by touching both probes with your fingers or a faulty reading will be obtained. At 77F, the resistance of the sensor will be 10K ohm. If the sensor is cooler than 77F, the resistance will be higher, if it is warmer, the resistance will be lower. After reading the resistance at room temperature, warm the tip of the sensor by holding it in the palm of your hand, and take another resistance reading. This reading should be noticeable lower than the room temperature reading. Temperature ( F) Resistance (ohms) 65 13476 70 11884 75 10501 80 9298 85 8249 90 7333 The zone panel is well equipped to monitor the operation of the probe and determine if a failure has occurred. The probe should be considered an integral (but replaceable) part of the zone panel. The zone panel will indicate if the probe is operating improperly and needs to be replaced. B2203458 10006259 Page 12