Ventilation Requirements Schedule SCHEDULE BASED ON IMC 2009

Similar documents
LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

HWC NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

University of Rochester October 17, 2008 Brooks Landing Business Center

DUKE UNIVERSITY CONSTRUCTION STANDARDS

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

A. Section Joint Sealants: Seal fixtures to walls and floors.

SECTION PLUMBING

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

DOMESTIC WATER PACKAGED BOOSTER PUMPS

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Plumbing Standards

DRAWING SCHEDULE TAB REQUIREMENTS BY EQUIPMENT TYPE TYPE OF EQUIPMENT DESCRIPTION COMPONENT TAB REQUIREMENTS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

GENERAL PLUMBING REQUIREMENTS

Mechanical Inspection Plumbing

2). Crane Co. 4). Kohler Co. 5). Universal-Rundle Corp. Revised September 29, 2017 Commercial Plumbing Fixtures

SECTION PLUMBING FIXTURES AND TRIM. A. Types of plumbing fixtures required for the project include the following:

SHOE PALACE HUNTINGTON PARK M.200

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

1. Division 22 Section "Emergency Plumbing Fixtures." 2. Division 22 Section "Drinking Fountains and Water Coolers."

GRILLE, REGISTER AND DIFFUSER SCHEDULE

A. General: comply with appropriate standards. 1. International Association of Plumbing and Mechanical Officials: IAPMO. 2. California State AB 1953.

PLUMBING FIXTURES, TRIM, AND SUPPORTS

GENERAL PLUMBING REQUIREMENTS

GENERAL PLUMBING NOTES

DESIGN AND CONSTRUCTION STANDARDS July 2011

SECTION PLUMBING SPECIALTIES

A. This Section includes the following domestic water piping specialties:

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

Willoughby Industries - Security Products

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SECTION DOMESTIC WATER PIPING SYSTEMS. 0. Pipe and pipe fittings are specified in the following sections:


PLUMBING DESIGN GUIDELINES SECTION DESIGN GUIDELINES DUVAL COUNTY PUBLIC SCHOOLS

SECTION DOMESTIC WATER PIPING SPECIALTIES

JAMES P. KISSANE, ARCHITECT

Mechanical/Plumbing Specification

Additions & Alterations to Ascension Parish Library Galvez Prairieville, Louisiana Project No. 1401

PRICE BOOK CONTENTS 010 PIPE

Plot # R019A ± 74' ± 74' ± 65' Plot # R019A LEASE OUTLINE DRAWING GROSS LEASABLE AREA ± 4,631 S.F. DEMISING FRONT WIDTH DEPTH ± 13' ± 32' Lease Line

AIRPORT PLUMBING DESIGN STANDARDS REV. 2 11/02/2015

SECTION PLUMBING FIXTURES

PRODUCTS THAT CONSERVE, REPAIR AND SAVE!

MATERIALS Traps TRAPS. No. IPC IRC Description

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION

Willoughby Industries - Security Products

TABLE OF CONTENTS DIVISION 22 - MECHANICAL

Unit # E ± 1,200 SF Width ± 20' Depth ± 60'

TABLE LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS ASHRAE Uncovered Parking Areas. Building Grounds. Walkways 10 feet wide or greater

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

GARCIA GALUSKA DESOUSA Consulting Engineers

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

Protected with TechCoat finish. For Ceramic Tile Showers Cast iron Threaded for test nipple Extra heavy (.050) strainer DRAIN CONNECTION

FEATURES. Other Fed-Flush Arrangements

GENERAL PLUMBING REQUIREMENTS

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

DeCA DESIGN CRITERIA HANDBOOK PLUMBING SYSTEMS

PARTS STOCKED REPLACEMENT FAUCET BIBB SCREWS... SCREW ASSORTMENT MISC. 3 /8" BIBB LOC SCREW 1 /2" BIBB SCREW 1 /2" BIBB LOC SCREW 3 /8" BIBB SCREW

AIRPORT PLUMBING DESIGN STANDARDS REV. 3 3/18/2016

FIRE ALARM: BY OTHERS, IF REQUIRED.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

TUBS & SURROUNDS FIBERGLASS TUB STANDARD FIBERGLASS GARDEN TUB

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Unit # H ± 2,000 SF Width ± 25' Depth ± 80'

FIRE ALARM: BY OTHERS, IF REQUIRED.

MUKWONAGO AREA SCHOOL DISTRICT CAPITAL IMPROVEMENT / MAINTENANCE STUDY

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Lasco # Description Picture Lasco # Description Picture

EQUIPMENT GUIDE LIST - CHAPTER

DIVISION 22: PLUMBING DESIGN STANDARDS TABLE OF CONTENTS

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

GENERAL PLUMBING NOTES 6. ALL RISES AND DROPS IN PIPING ARE NOT NECESSARILY SHOWN

Electrical Information

CHILD DEVELOPMENT & LITERACY CENTER H17-N104-CB SGA 17002

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

REAR. Exit 5'-9" 6'-1" 8'-3" 6'-1" Freezer Entrance Stall

Unit # 1038 ± 900 SF Width ± 15' Depth ± 60'

ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED

COMcheck Software Version Interior Lighting Compliance Certificate

Yale University Design Standards

SECTION STEAM CONDENSATE PUMPS

FRESH FROM THE KITCHEN FRESH FROM THE KITCHEN

2016 Plumbing Supplemental Plan Review List

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

WATER SUPPLY HOOK-UP DISPLAY 0-WSH-1

CLINICAL SERVICES ADMINISTRATION (214)

A. This Section includes the following emergency plumbing fixtures:

Electrical System (N) PANELBOARD "L1" VOLTAGE: 208/120 A, 3P :MAIN C/B PHASE: 3 A :BUSSING WIRE: 4 :MOUNTING

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT

PROPOSED NEW BUILDING

Paradise Marketplace. Unit # AOP +/- 1,600 SF +/- 12' +/- 11' +/- 8' 11'-7" +/- 85' +/- 74' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width.

BSD Technical Standard. Division 22: Plumbing

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D20 PLUMBING 02/18

Transcription:

Ventilation Requirements Schedule SCHEDULE BASED ON IMC 2009 occupancy Gross OccupantsOccupancy Minimum O/A Effectiveness Table 403.3. Single Zone System plumb Minimum Exhaust Actual unit operating conditions Rm. Space description classification Area per count CFM/Occ CFM/SF O/A CFM cooling heating cooling heating fixt. CFM/SF CFM/Fixt TOTAL MIN O/A > Voz conveyance No. (table 403.3) () Pz Rp= Ra= Vbz= Ez = Ez = Voz Voz count S/A Vot = (%) status equipment RTU-1 S Offices 1 Open Office Offices: office 787 5 3 7.5 0.12 116.9 1.0 0.8 116.9 146.2 0.0 0.00 0 0 900 161 10% Pass RTU-1 3.5 3 Office Offices: office 204 5 1 7.5 0.12 32.0 1.0 0.8 32.0 40.0 0.0 0.00 0 0 300 54 34% Pass ratio = 18% 2 Corridor Public: Corridor 86 0 0 0.0 0.06 5.2 1.0 0.8 5.2 6.5 0.0 0.00 0 0 200 36 454% Pass S/A = 1400 0 0% - S O/A = 250.0 Subtotals 1077 4 154.1 154 193 0.0 1400 250 Pass Pass RTU-2 Camera Lab 4 Camera Lab Offices: office 1278 5 6 7.5 0.12 198.4 1.0 0.8 198.4 248.0 0.0 0.00 0 0 1950 250 1% Pass RTU-2 5 0 0% - ratio = 13% 0 0% - S/A = 1950 0 0% - S O/A = 250 Subtotals 1278 6 198.4 198 248 0.0 1950 250 Pass Pass RTU-3 N exist bldg 5 Tool Room Offices: office 256 5 1 7.5 0.12 38.2 1.0 0.8 38.2 47.8 0.0 0.00 0 0 400 90 88% Pass RTU-3 5 6 break room eneral: break room 263 70 10 7.5 0.12 106.6 1.0 0.8 106.6 133.2 0.0 0.00 0 0 600 135 1% Pass ratio = 23% 7 Laser + Comp Offices: office 245 5 1 7.5 0.12 36.9 1.0 0.8 36.9 46.1 0.0 0.00 0 0 360 81 76% Pass S/A = 2000 8 Long Corridor Public: Corridor 269 0 0 0.0 0.06 16.1 1.0 0.8 16.1 20.2 0.0 0.00 0 0 640 144 614% Pass S O/A = 450 Subtotals 1033 12 197.8 198 247 0.0 2000 450 Pass Pass RTU-4 shaftfiber-utility 9 Utility room Offices: office 358 5 1 7.5 0.12 50.5 1.0 0.8 50.5 63.1 0.0 0.00 0 0 550 103 63% Pass RTU-3 4 10 Shaft-fiber rm Offices: office 313 5 1 7.5 0.12 45.1 1.0 0.8 45.1 56.3 0.0 0.00 0 0 450 84 50% Pass ratio = 19% 11 Restrooms Public: restrooms 425 0 0 0.0 0.12 51.0 1.0 0.8 51.0 63.8 0.0 0.00 0 0 400 75 18% Pass S/A = 1600 12 Corridor Public: Corridor 240 0 0 0.0 0.06 14.4 1.0 0.8 14.4 18.0 0.0 0.00 0 0 200 38 108% Pass S O/A = 300 Subtotals 1336 2 160.9 161 201 0.0 1600 300 Pass Pass RTU-5 Rigid Lab 13 Rigid Lab Offices: office 2652 5 13 7.5 0.12 415.7 1.0 0.8 415.7 519.7 0.0 0.00 0 0 3200 600 15% Pass RTU-6 8 0 0% - ratio = 19% 0 0% - S/A = 3200 0 0% - S O/A = 600 Subtotals 2652 13 415.7 416 520 0.0 3200 600 Pass Pass RTU-6 Flex Lab West 14 Flex Lab Offices: office 1818 5 9 7.5 0.12 285.7 1.0 0.8 285.7 357.1 0.0 0.00 0 0 3200 500 40% Pass RTU-3 8 0 0% - ratio = 16% 0 0% - S/A = 3200 0 0% - S O/A = 500 Subtotals 1818 9 285.7 286 357 0.0 3200 500 Pass Pass RTU-7 Flex Lab East 15 Flex Lab Offices: office 1835 5 9 7.5 0.12 287.7 1.0 0.8 287.7 359.6 0.0 0.00 0 0 3000 516 43% Pass RTU-3 8 16 utility rooms Public: Corridor 433 0 0 0.0 0.06 26.0 1.0 0.8 26.0 32.5 0.0 0.00 0 0 200 34 6% Pass ratio = 17% sa 0 0% - S/A = 3200 0 0% - S O/A = 550 Subtotals 2268 9 313.7 314 392 0.0 3200 550 Pass Pass 8810 Formula variables: Where: Az - Zone floor area: the net occupiable floor area of the floor space or spaces in the zone. Single Zone Systems - where occupanccy in unknown or varies throughtout the day Pz - Zone population: the number of people in the space or spaces in the zone. Rp - People outdoor air rate: the outdoor airflow rate required per person from table 403.3 Rp - Area outdoor air rate: the outdoor airflow rate required per unit area from table 403.3

LIGHT FIXTURE SCHEDULE TYPE DESCRIPTION LAMPS / MANUFACTURER TOTAL VOLTS WATT A 2 FT x 4 FT LAY-N ACRYLIC LENSED (ELECTRONIC BALLASTS) (4) F032T8 COLUMBIA LIGHTING: 110 120V. #ST824-432G-FAA19-4EU-PAF AE SAME AS TYPE-A EXCEPT (ELECTRONIC BALLSTS) (4) F032T8 COLUMBIA LIGHTING: 110 AND EMERGENCY BATTERY PACK. 120V. #ST824-432G-FAA19-4EU-PAF-EL A1 2 FT x 2 FT LAY-N ACRYLIC LENSED (ELECTRONIC BALLASTS) (2) F017T8 COLUMBIA LIGHTING: 30 120V. #ST822-217G-FAA19-EU-PAF A1E SAME AS TYPE-A1 EXCEPT (ELECTRONIC BALLSTS) (2) F017T8 COLUMBIA LIGHTING: 30 FOR EMERGENCY BATTERY PACK. 120V. #ST822-217G-FAA19-EU-PAF-EL B 2 FT x 4 FT LAY-N ACRYLIC LENSED (ELECTRONIC BALLASTS) (3) F032T8 COLUMBIA LIGHTING: 83 120V. #ST824-332G-FAA19-3EU-PAF BE SAME AS TYPE-B EXCEPT (ELECTRONIC BALLSTS) (3) F032T8 COLUMBIA LIGHTING: 83 FOR EMERGENCY BATTERY PACK. 120V. #ST824-332G-FAA19-3EU-PAF-EL B1 2 FT x 4 FT SURFACE ACRYLIC LENSED (ELECTRONIC BALLASTS) (3) F032T8 COLUMBIA LIGHTING: 83 120V. #MWW4-332-3EU B1E SAME AS TYPE-B1 EXCEPT (ELECTRONIC BALLSTS) (3) F032T8 COLUMBIA LIGHTING: 83 AND EMERGENCY BATTERY PACK. 120V. #MWW4-332-3EU-EL C 2 FT x 4 FT LAY-N ACRYLIC LENSED (1- ELECTRONIC BALLASTS) (2) F032T8 COLUMBIA LIGHTING: 57 120V. #ST824-232G-FAA19-E-PAF CE SAME AS TYPE-C EXCEPT (2-ELECTRONIC BALLSTS) (2) F032T8 COLUMBIA LIGHTING: 57 AND EMERGENCY BATTERY PACK. 120V. #ST824-232G-FAA19-E-PAF-EL D 4' STRIP (2) F032T8 COLUMBIA LIGHTING: 57 120V. #CS4-232-EU-PAF F 6" RECESSED, BLACK BAFFLE OPEN DOWNLIGHT (1) 13 W. PRECOLITE 18 QUAD TUBE 120V. #IBX13ICAT TB60 S1 6" RECESSED, BLACK BAFFLE OPEN DOWNLIGHT (1) 26 W. PRECOLITE 29 MAGNETIC BALLAST, UL- LISTED FOR DAMP LOCATION QUAD TUBE 120V. #LF6CFV26EB-6CFVCLWTB6 S2 8" RECESSED ADJUSTABLE OPEN, BLACK ALZAK, (1) 70 MH PRECOLITE 90 MAGNETIC BALLAST, UL- LISTED FOR DAMP LOCATION PAR-38 120V. #1475M7-70MHFE-WT432-B24 S3 WALL ARM OUTLET BOX, WET ENCLOSED/GASKETED, (1) 13 W. HUBBELL 18 GLOBE/GUARD - STANDARD AND TEMPERED GLASS. 13DTT 120V. #AVW21 X UNIVERSAL MOUNTING LED EXIT SIGN FACE LED DUAL-LITE LED RED LETTERS / WHITE, EMERGENCY BATTERY PACK. 120V. #LX1URWE X1 UNIVERSAL MOUNTING LED EXIT DOUBLE FACE LED DUAL-LITE LED RED LETTERS / WHITE, EMERGENCY BATTERY PACK. 120V. #LX2URWE EM EXTERIOR WALL MOUNTED EMERGENCY UNIT, DARK BRONZE (2) 6 W. HUBBELL WITH EMERGENCY BATTERY PACK XENON 6V./120V. #LSCI

MAIN DISTRIBUTION PANEL-"MDP" IC: 24,000 AMPS, RMS, SYM. MOUNTING: SURFACE SERVICE:120/208V., 3-PH, 4-W, 600A., COPPER BUS & EQUIP. GRD. MAINS: 600 AMPS, MLO C CCT A SERVES "MAIN-1" THRU "MAIN-6" KVA AMPS FRAME TRIP FEEDER / REMARKS NO. T 1 G PANEL-"M" 73.8 204.8 400A./3P. 300A. 4#350 CU.,1#3 CU.GRD.,3"C. 2 G PANEL-"A" 68.2 189.2 225A./3P. 225A. 4#4/0 CU.,1#3 CU.GRD.,2-1/2"C. 3 G PANEL-"B" 31.4 87.1 125A./3P. 125A. 4#1 CU.,1#6 CU.GRD.,2"C. 4 G EMERG. GENERATOR FOR PANEL-"E" 20.0 16.0 100A./3P. 70A. 3#6 CU.,1#8 CU.GRD.,1"C. 5 SPACE 6 SPACE LIGHTS REC GEN DATA MTRS LGST MTR COOLING HEATING KITCHEN OTHER SPARE TOTALS CONNECTED KVA 0 0 193 0 0 0 0 0 0 0 0 193.4 KVA DESIGN FACTOR 1.25 NEC 1.0 0.0 1.0 0.25 0.0 0.0 0 0.0 1.0 536.8 AMPS DESIGN KVA 0 0 193 0 0 0 0 0 0 0 0 193.4 KVA NOTES" 1. ALL BREAKERS SHALL BE SERVICE ENTRANCE RATED. 2. ELECTRICAL CONTRACTOR TO LABEL ALL BREAKERS AS MAINS. PANEL-"M" SECTION 1 OF 1 IC: 24,000 AMPS, RMS, SYM. MOUNTING: SURFACE SERVICE:120/208V., 3-PH, 4-W, 400A., COPPER BUS & EQUIP. GRD. MAINS: 300 AMPS, MLO C AMPS A AMPS C FEEDER CCT A REMARKS LOAD VOLT-AMPERES & B & LOAD VOLT-AMPERES REMARKS A CCT FEEDER NO. T A B C POLES C POLES A B C T NO. 3#6,#8G.,1"C. 1 C NEW RTU-7 5364 60/3 60/3 5364 RTU-6 C 2 3#6,#8G.,1"C. --- 3 C --- 5364 HACR HACR 5364 --- C 4 --- --- 5 C --- 5364 -- -- 5364 --- C 6 --- 3#8,#10G.,3/4"C. 7 C NEW RTU-3 3852 45/3 60/3 5364 RTU-5 C 8 3#6,#8G.,1"C. --- 9 C --- 3852 HACR HACR 5364 --- C 10 --- --- 11 C --- 3852 -- -- 5364 --- C 12 --- 13 SPACE 45/2 2912 (EXIST.) RTU-1 C 14 2#8,#10G.,3/4"C. 15 SPACE HACR 2912 --- C 16 --- 17 SPACE 60/2 4056 (EXIST.) RTU-2 C 18 2#6,#8G.,1"C. 19 SPACE HACR 4056 --- C 20 --- 21 SPACE SPACE 22 23 SPACE SPACE 24 LIGHTS REC GEN DATA MTRS LGST MTR COOLING HEATING KITCHEN OTHER SPARE TOTALS CONNECTED VA 0 0 0 0 0 0 73768 0 0 0 0 73.8 KVA DESIGN FACTOR 1.25 NEC 1.0 0.0 1.0 0.25 1.0 0.0 0 0.0 1.0 204.8 AMPS DESIGN VA 0 0 0 0 0 0 73768 0 0 0 0 73.8 KVA PANEL-"A" SECTION 1 OF 2 IC: 24,000 AMPS, RMS, SYM. MOUNTING: SURFACE SERVICE:120/208V., 3-PH, 4-W, 225A. COPPER BUS & EQUIP. GRD. MAINS: 225 AMPS, MLO C AMPS A AMPS C FEEDER CCT A REMARKS LOAD VOLT-AMPERES & B & LOAD VOLT-AMPERES REMARKS A CCT FEEDER NO. T A B C POLES C POLES A B C T NO. 2#12,#12G.,1/2"C. 1 G FIRE ALARM PNL. 200 20/1 20/1 1761 LIGHTS, EF-2 L 2 2#10,#10G.,3/4"C. 2#12,#12G.,1/2"C. 3 G SECURITY PNL. 200 20/1 20/1 1776 LIGHTS L 4 2#10,#10G.,3/4"C. 2#12,#12G.,1/2"C. 5 R RIGID LAB RECEPT. 1400 20/1 20/1 1776 LIGHTS L 6 2#10,#10G.,3/4"C. 2#12,#12G.,1/2"C. 7 R RIGID LAB RECEPT. 1080 20/1 20/1 1400 WORK BEN. RECEPT. R 8 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 9 R RIGID LAB RECEPT. 720 20/1 20/1 1400 WORK BEN. RECEPT. R 10 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 11 R RIGID LAB RECEPT. 1400 20/1 20/1 1400 WORK BEN. RECEPT. R 12 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 13 R WORK BEN. RECEPT. 1400 20/1 20/1 1400 WORK BEN. RECEPT. R 14 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 15 R WORK BEN. RECEPT. 1400 20/1 20/1 1400 WORK BEN. RECEPT. R 16 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 17 R WORK BEN. RECEPT. 1400 20/1 20/1 1400 WORK BEN. RECEPT. R 18 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 19 R RIGID LAB RECEPT. 1400 20/1 20/1 1400 SHAFT/FIBER RECEPT R 20 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 21 R RIGID LAB RECEPT. 1400 20/1 20/1 540 SHAFT/FIBER RECEPT M 22 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 23 R UTILITY RECEPT. 1080 20/1 20/1 1400 UTILITY RECEPT. M 24 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 25 R CONV. OUTLETS 540 20/1 20/1 180 RIGID LAB. RECEPT. R 26 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 27 R CONV. OUTLETS 720 20/1 20/1 900 CONV. OUTLETS R 28 2#12,#12G.,1/2"C. 2#10,#10G.,3/4"C. 29 M VENT HOOD 2110 30/1 20/1 600 EWC R 30 2#12,#12G.,1/2"C. 2#10,#10G.,3/4"C. 31 O OVEN NEW 2184 30/1 20/2 520 VACUUM SYSTEMS R 32 2#12,#12G.,1/2"C. 2#10,#10G.,3/4"C. 33 O OVEN NEW 2184 30/1 -- 520 --- R 34 --- 2#10,#10G.,3/4"C. 35 O OVEN EXISTING 1596 20/1 20/1 200 TIME CLOCK G 36 2#12,#12G.,1/2"C. 2#10,#10G.,3/4"C. 37 O OVEN EXISTING 1596 20/1 20/1 400 MONUMENT SIGN G 38 2#12,#12G.,1/2"C. 2#10,#10G.,3/4"C. 39 M OVEN EXISTING 1920 30/1 20/1 240 1ST. EXTERIOR LTS. L 40 2#12,#12G.,1/2"C. 2#10,#10G.,3/4"C. 41 R DRILL (1 HP) 1920 20/1 20/1 660 2ND. EXTERIOR LTS. L 42 2#12,#12G.,1/2"C. LIGHTS REC GEN DATA MTRS LGST MTR COOLING HEATING KITCHEN OTHER SPARE TOTALS CONNECTED VA 10861 62640 1000 0 5970 2110 0 0 0 10760 0 91.2 KVA DESIGN FACTOR 1.25 NEC 1.0 0.0 1.0 0.25 0.0 0.00 0.00 1.00 1.00 189.2 AMPS DESIGN VA 13576 36320 1000 0 5970 528 0 0 0 10760 0 68.2 KVA PANEL-"A" SECTION 2 OF 2 IC: 24,000 AMPS, RMS, SYM. MOUNTING: SURFACE SERVICE:120/208V., 3-PH, 4-W, 225A. COPPER BUS & EQUIP. GRD. MAINS: 225 AMPS, MLO C AMPS A AMPS C FEEDER CCT A REMARKS LOAD VOLT-AMPERES & B & LOAD VOLT-AMPERES REMARKS A CCT FEEDER NO. T A B C POLES C POLES A B C T NO. 2#12,#12G.,1/2"C. 43 R DATA RECEPT. 360 20/1 20/1 1172 LIGHTS L 44 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 45 R TV RECEPT. 500 20/1 20/1 888 LIGHTS L 46 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 47 R CONV. OUTLET 1080 20/1 20/1 1167 LIGHTS L 48 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 49 R DATA RECEPT. 720 20/1 20/1 1421 LIGHTS L 50 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 51 R CONV. OUTLET 1080 20/1 20/1 1400 CAMERA LAB RECEPT R 52 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 53 R MICROWAVE 1500 20/1 20/1 1080 CAMERA LAB RECEPT R 54 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 55 R COFFEE MAKE 1200 20/1 20/1 1400 WORK BEN, RECEPT. R 56 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 57 R DISPOSAL 1200 20/1 20/1 1400 WORK BEN, RECEPT. R 58 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 59 R MICROWAVE 1500 20/1 20/1 1400 WORK BEN, RECEPT. R 60 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 61 R MICROWAVE 1500 20/1 20/1 1400 WORK BEN, RECEPT. R 62 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 63 R (EXIST.) RECEPT. 900 20/1 20/1 1400 WORK BEN, RECEPT. R 64 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 65 R CM - RECEPT. 540 20/1 20/1 1400 WORK BEN, RECEPT. R 66 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 67 R CM - RECEPT. 540 20/1 20/2 1600 LASER WELD O 68 2#8,#10G.,1"C. 2#12,#12G.,1/2"C. 69 R TIME CLOCK 200 20/1 -- 1600 --- O 70 --- 2#12,#12G.,1/2"C. 71 R HAND DRYER 1500 20/1 20/1 360 RECEPT. R 72 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 73 R HAND DRYER 1500 20/1 20/1 1000 SEASONAL OUTLETS R 74 2#10,#10G.,3/4"C. 2#12,#12G.,1/2"C. 75 R HAND DRYER 1500 20/1 20/1 1000 SEASONAL OUTLETS R 76 2#10,#10G.,3/4"C. 2#12,#12G.,1/2"C. 77 R HAND DRYER 1500 20/1 20/1 1000 SEASONAL OUTLETS R 78 2#10,#10G.,3/4"C. 79 SPACE 20/1 1000 SEASONAL OUTLETS R 80 2#10,#10G.,3/4"C. 81 SPACE 20/1 200 IRRIGATION SYSTEM R 82 2#12,#12G.,1/2"C. 83 SPACE SPACE 84 EMERGENCY PANEL-"E" SECTION 1 OF 1 IC: 24,000 AMPS, RMS, SYM. MOUNTING: SURFACE SERVICE:120/208V., 3-PH, 4-W, 100A., COPPER BUS & EQUIP. GRD. MAINS: 100 AMPS, MLO C AMPS A AMPS C FEEDER CCT A REMARKS LOAD VOLT-AMPERES & B & LOAD VOLT-AMPERES REMARKS A CCT FEEDER NO. T A B C POLES C POLES A B C T NO. 2#12,#12G.,3/4"C. 1 R TEL. QUAD RECETP. 400 20/1 40/3 3396 RTU-6 C 2 3#8,#10G.,1"C. 2#12,#12G.,3/4"C. 3 R COMP. RECEPT. 540 20/1 HACR 3396 --- C 4 --- 2#12,#12G.,3/4"C. 5 R REFRIG. 500 20/1 --- 3396 --- C 6 --- 2#12,#12G.,3/4"C. 7 L REST. RM. LTS. & EF-2 655 20/1 SPACE 8 9 SPARE 20/1 SPACE 10 11 SPARE 20/1 SPACE 12 LIGHTS REC GEN DATA MTRS LGST MTR COOLING HEATING KITCHEN OTHER SPARE TOTALS CONNECTED VA 655 1440 0 0 0 0 10188 0 0 0 0 12.3 KVA DESIGN FACTOR 1.25 NEC 1.0 0.0 1.0 0.25 1.0 0.0 0 0.0 1.0 34.5 AMPS DESIGN VA 819 1440 0 0 0 0 10188 0 0 0 0 12.4 KVA PANEL-"B" SECTION 1 OF 1 IC: 24,000 AMPS, RMS, SYM. MOUNTING: SURFACE SERVICE:120/208V., 3-PH, 4-W, 125A., COPPER BUS & EQUIP. GRD. MAINS: 125 AMPS, MLO C AMPS A AMPS C FEEDER CCT A REMARKS LOAD VOLT-AMPERES & B & LOAD VOLT-AMPERES REMARKS A CCT FEEDER NO. T A B C POLES C POLES A B C T NO. 2#12,#12G.,1/2"C. 1 R WORK BEN. RECEPT. 1440 20/1 20/1 1389 LIGHTS L 2 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 3 R WORK BEN. RECEPT. 1440 20/1 20/1 999 LIGHTS L 4 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 5 R WORK BEN. RECEPT. 1440 20/1 20/1 1776 LIGHTS L 6 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 7 R WORK BEN. RECEPT. 1440 20/1 20/1 1332 LIGHTS L 8 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 9 R WORK BEN. RECEPT. 1440 20/1 20/1 776 LIGHTS, EF-3 & 4 L 10 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 11 R WORK BEN. RECEPT. 1440 20/1 20/1 540 CONV. OUTLET R 12 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 13 R WORK BEN. RECEPT. 1440 20/1 20/1 720 CONV. OUTLET R 14 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 15 R WORK BEN. RECEPT. 720 20/1 20/1 1440 WORK BEN. RECEPT. R 16 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 17 R WORK BEN. RECEPT. 720 20/1 20/1 1440 WORK BEN. RECEPT. R 18 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 19 R WORK BEN. RECEPT. 1080 20/1 20/1 1440 WORK BEN. RECEPT. R 20 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 21 R FLEX LAB RECEPT. 540 20/1 20/1 1440 WORK BEN. RECEPT. R 22 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 23 R FLEX LAB RECEPT. 540 20/1 20/1 1440 WORK BEN. RECEPT. R 24 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 25 R MC RECEPT. 540 20/1 20/1 540 FLEX LAB RECEPT. R 26 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 27 R ROOF RECEPT. 1260 20/1 20/1 180 DATA RECEPT. R 28 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 29 L ROOF LIGHTS 420 20/1 20/1 360 MC RECEPT. R 30 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 31 M COMP. AIR DRYER 1600 20/1 20/1 1500 HAND DRYER R 32 2#12,#12G.,1/2"C. 2#12,#12G.,1/2"C. 33 H WH-1 1000 20/2 20/1 1500 HAND DRYER R 34 2#12,#12G.,1/2"C. --- 35 H --- 1000 -- 20/1 1000 SPARE 36 37 SPACE SPACE 38 39 SPACE SPACE 40 41 SPACE SPACE 42 LIGHTS REC GEN DATA MTRS LGST MTR COOLING HEATING KITCHEN OTHER SPARE TOTALS CONNECTED VA 6692 28020 0 0 1600 1600 0 2000 0 0 0 38.3 KVA DESIGN FACTOR 1.25 NEC 1.0 0.0 1.0 0.25 0.0 1.0 0 0.0 1.0 87.1 AMPS DESIGN VA 8365 19010 0 0 1600 400 0 2000 0 0 0 31.4 KVA

GAS LOAD SUMMARY QUANITY DESIGNATION EQUIPMENT ITEM TOTAL OR ITEM NUMBER DESCRIPTION CFH CFH 1 RTU-1 EX ROOFTOP UNIT 90.00 90.00 1 RTU-2 EX ROOFTOP UNIT 105.00 105.00 1 RTU-3 ROOFTOP UNIT 60.00 60.00 1 RTU-4 ROOFTOP UNIT 60.00 60.00 1 RTU-5 ROOFTOP UNIT 120.00 120.00 1 RTU-6 ROOFTOP UNIT 120.00 120.00 1 RTU-7 ROOFTOP UNIT 120.00 120.00 - - 1 EMERG. GEN. EMERGENCY GENERATOR 299.00 299.00 SUBTOTAL 974.00 TOTAL GAS LOAD 974.00 SYSTEM INFORMATION OZS PER INCHES OF SQ INCH PRESSURE LEAVING METER 7 12.11 TOTAL EQUIVELANT PIPE LENGTH IN FEET 150 WATER COLUMN

ELECTRIC WATER HEATER SCHEDULE DESIGNATION MODEL MANUFACTURER STORAGE RECOVERY TEMPERATURE LEAVING ELECTRICAL CHARACTERISTICS REMARKS/SPECIAL INSTRUCTIONS NUMBER GALLONS RATE RISE WATER K.W. VOLTAGE PHASE G.P.H. TEMPERATURE WH DEN-30 A.O. SMITH 30 8 100 140 2 208 1 CONTRACTOR SHALL INSTALL EXPANSION TANK IF REQUIRED. INSTALL WATER HEATER PER MANUFACTURERS INSTRUCTIONS INSTALL THERMOSTATIC MIXING VALVE SIMILAR TO SYMMONS #410-B ON EACH FAUCET GENERAL NOTES: 1. CONTRACTOR SHALL PROVIDE DIELECTRIC UNIONS AT WATER HEATER CONNECTIONS. 2. CONTRACTOR SHALL PROVIDE BALL VALVES AT WATER HEATER CONNECTIONS. 3. CONTRACTOR SHALL PROVIDE T&P RELIEF VALVE, DRAIN VALVE AND EMERGENCY OVERFLOW DRAIN PAN FOR WATER HEATER. T & P AND OVERFLOW DRAINS 4. DISCHARGE OUTSIDE OR INTO NEAREST OPEN SIGHT DRAIN. DOMESTIC HOT WATER CIRCULATOR SCHEDULE DESIGNATION MODEL MANUFACTURER TOTAL IMPELLER & TOAL GPM PUMP ELECTRICAL CHARACTERISTICS REMARKS/SPECIAL INSTRUCTIONS NUMBER HEAD IN VOLUTE WATTAGE H.P. VOLTAGE PHASE FEET MATERIAL CP-1 UP25-64BF GRUNFOS 15 BRONZE 20 185 1/12 115 1 REFER TO INSTALLATION DETAIL DO NOT MOUNT MOTOR SHAFT IN VERTICAL POSITION GENERAL NOTES: 1. CONTRACTOR SHALL PROVIDE TIMER AND THERMOSTAT CONTROL OF PUMP, REFER TO DETAIL 2. CONTRACTOR SHALL INSTALL PUMP PER MANUFACTURERS REQUIREMENTS AND RECOMMENDATIONS. SPECIAL NOTE (NEW PLUMBING FIXTURE) CONTRACTOR SHALL EXTEND PIPING FROM NEW PLUMBING FIXTURE TO PIPING SERVING EXISTING PLUMBING FIXTURE, THEN MAKE FINAL CONNECTION. CONTRACTOR SHALL SAW CUT AND MODIFY EXISTING FLOORS, WALLS, AND CEILINGS TO INSTALL NEW PIPING. AFTER NEW PIPING IS INSTALLED AND TESTED, CONTRACTOR SHALL REPAIR FLOORS, WALLS AND CEILINGS TO MATCH ADJACENT FLOORS, WALLS, AND CEILINGS. ADA/TAS PLUMBING FIXTURES CONTRACTOR SHALL VERIFY ADA/TAS PLUMBING FIXTURE LOCATIONS AND REQUIREMENTS WITH FINAL ARCHITECTURAL CONSTRUCTION DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL ADA/TAS APPROVED PLUMBING FIXTURES SHOWN ON THE FINAL ARCHITECTURAL CONSTRUCTION CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS. CONTRACTOR SHALL INSTALL ADA/TAS APPROVED PLUMBING FIXTURES TO COMPLY THE LATEST VERSIONS OF THE ADA AND TEXAS ACCESSIBILITY STANDARDS CODES. MANUFACTURER SAN. COLD HOT DESIG. DESCRIPTION & MODEL SWR VENT WTR WTR DESCRIPTION / REMARKS NUMBER SIZE SIZE SIZE SIZE FLOOR MOUNTED AMERICAN STANDARD 4" 2" 1" - FLOOR MOUNTED DIRECT FED SIPHON JET ACTION ELONGATED BOWL VITREOUS CHINA WC WATER CLOSET MADERA #2234.015 SIPHON JET ACTION TOP SPUD BOWL, BOLT CAPS SLOAN ROYAL #111-1.6 FLUSH VALVE OLSONITE FLUSH VALVE WITH VACUUM BREAKER ANGLE STOP AND FLUSH CONNECTION. 1.5 GPF PLASTIC SEAT FLOOR MOUNTED AMERICAN STANDARD 4" 2" 1" - FLOOR MOUNTED DIRECT FED SIPHON JET ACTION ELONGATED BOWL VITREOUS CHINA WATER CLOSET MADERA #3461.001 SIPHON JET ACTION TOP SPUD BOWL, BOLT CAPS SLOAN ROYAL #111-1.6 HWC FLUSH VALVE OLSONITE FLUSH VALVE WITH VACUUM BREAKER ANGLE STOP AND FLUSH CONNECTION. 1.6 GPF PLASTIC SEAT ADA APPROVED UR LAV LAV2 KS SK-1 SK-2 EWC MS FD RD OD FCO CO WCO NFHB PLUMBING FIXTURE SCHEDULE WALL HUNG AMERICAN 2" 2" 3/4" - VITREOUS CHINA WASHOUT LOW CONSUMPTION 1.0 GALLON PER FLUSH URINAL URINAL STANDARD WITH 3/4 INCH TOP SPUD, 2 INCH FEMALE THREADED OUTLET, 3/4 INCH TOP SPUD 1.0 GPF LYNBROOK TWO WALL HANGERS MOUNTED ON STRUCTURAL STEEL SUPPORTS ANCHORED TO FLOOR. INFRA-RED #6601.012 FURNISH URINAL COMPLETE WITH SLOAN ROYAL #186-1.0 FLUSH VALVE AND ADA APPROVED FLOOR MOUNTED CAST IRON SUPPORTS SIMILAR TO JOSAM PRO-SET UPRIGHTS. CONSULT ARCHITECT'S DRAWINGS FOR MOUNTING HEIGHT COUNTERTOP AMERICAN 2" 2" 1/2" 1/2" VITREOUS CHINA, FRONT OVERFLOW WITH 8 INCH CENTER SET FAUCET COUNTERTOP LAVATORY STANDARD LAVATORY. FURNISHED COMPLETE WITH CHROME PLATED OFFSET 1 1/2 INCH P-TRAP H & CW SUPPLIES AQUALYN ANGLE STOPS WITH FLEXIBLE METAL SUPPLIES, HANDI LAV GUARD INSULATION KIT, AND ADA #0476.020 MOEN MODEL 8228 8" CENTER SET FAUCET WALL HUNG AMERICAN 2" 2" 1/2" 1/2" VITREOUS CHINA, FRONT OVERFLOW WITH 8 INCH CENTER SET FAUCET WALL HUNG LAVATORY STANDARD LAVATORY. FURNISHED COMPLETE WITH CHROME PLATED OFFSET 1 1/2 INCH P-TRAP H & CW SUPPLIES LUCERNE ANGLE STOPS WITH FLEXIBLE METAL SUPPLIES, HANDI LAV GUARD INSULATION KIT, AND ADA #0356.015 MOEN MODEL 8228 8" CENTER SET FAUCET DOUBLE BOWL JUST MFG 2" 2" 1/2" 1/2" DOUBLE COMPARTMENT 18 GAUGE STAINLESS STEEL SINK WITH THREE HOLE PUNCHING COMPARTMENT DBW-2133-A-GR-L STAINLESS STEEL SELF RIMMING SINK 5 1/2 INCHES DEEP FOR ADA. STAINLESS STEEL MOEN #8799 FAUCET 1/2 HP 115 V DISPOSAL KITCHEN SINK ADA SINGLE JUST MFG 2" 2" 1/2" 1/2" SINGLE COMPARTMENT 18 GAUGE STAINLESS STEEL SINK WITH THREE HOLE PUNCHING COMPARTMENT SL-ADA-1921-A-GR STAINLESS STEEL SELF RIMMING SINK 6 INCHES DEEP FOR ADA. STAINLESS STEEL MOEN #8799 FAUCET ADA SINGLE JUST MFG 2" 2" 1/2" 1/2" SINGLE COMPARTMENT 18 GAUGE STAINLESS STEEL SINK WITH THREE HOLE PUNCHING COMPARTMENT SL-ADA-2131-A-GR STAINLESS STEEL SELF RIMMING SINK 6 INCHES DEEP FOR ADA. STAINLESS STEEL MOEN #8799 FAUCET ADA WALL HUNG ELKAY 2" 2" 1/2" - SELF-CONTAINED, WALL HUNG ELECTRIC REFRIGERATED HI LO WATER COOLER. ELECTRIC WATER EZTL8C CHILLING CAPACITY OF 50 F DRINKING WATER, BASED UPON 80 F INLET COOLER WITH WATER AND 90 F AMBIENT LEAD FILTER SQUARE FIAT TERRAZZO TSB-100 24 INCH X 24 INCH X 12 INCH MOP SINK WITH DELTA 28T2383 FAUCET MOP SINK TSB-100 3" 2" 3/4" 3/4" FIAT NO. 898-CC MOP HANGER, NO. 832-AA HOSE WITH BRACKET WITH GUARD AND NO. 1453-BB STAINLESS STEEL STRAINER. HOSE PROVIDE ONE MSG 2424 WALL GUARD. FLOOR DRAIN WADE 3" 2" 1/4" - CAST IRON BODY, FLASHING COLLAR WITH NICKEL BRONZE ADJUSTABLE STRAINER HEAD, FOR RESTROOMS 1100 TRAP PRIMER CONNECTION, VANDALPROOF TOP,, SPEED SET OUTLET AND NO AND EXPOSED WITH TRAP PRIMER HUB ADAPTER. VERIFY ROUND OR SQUARE TOP WITH ARCHITECT AREAS CONNECTION ROOF DRAIN WADE - - - - COATED CAST IRON LEVELEZE ROOD RAIN, LARGE CAST IRON LOCKING DOME, WITH CAST IRON 3000AE-42-53 NON-PUNCTURING CLAMP RING WITH INTEGRAL GRAVEL STOP SUPPORTING RING DOME ADJUSTABLE TOP WITH WIDE ROOF FLANGE, LARGE SUMP WITH ANCHOR FLANGE AND BOTTOM OUTLET, DECK CLAMP ASSEMBLY, VANDALPROOF DOME. OVERFLOW WADE - - - - COATED CAST IRON LEVELEZE ROOD RAIN, LARGE CAST IRON LOCKING DOME, WITH CAST IRON 3000AE-SD-42-53 NON-PUNCTURING CLAMP RING WITH INTEGRAL GRAVEL STOP SUPPORTING RING DOME ADJUSTABLE TOP WITH WIDE ROOF FLANGE, LARGE SUMP WITH ANCHOR FLANGE AND BOTTOM OUTLET, DECK CLAMP ASSEMBLY, VANDALPROOF DOME. PROVIDE 2 INCH INTERNAL WATER GUARD. INTERIOR FLOOR WADE COATED CAST IRON KLEENATRON, LEVELEZE FLOOR CLEANOUT, INTEGRAL GASKETED CLEANOUT 6000STD-1 BRONZE CLEANOUT PLUG, ADJUSTABLE HOUSING WITH SCORIATED SECURED ROUND NICKALOY TOP. CONTRACTOR SHALL SELECT COVER FOR FLOOR COVERING USED REFER TO ARCHITECTURAL DRAWINGS FOR TYPE OF FLOOR COVERING. EXTERIOR WADE COATED CAST IRON KLEENATRON, LEVELEZE FLOOR CLEANOUT, INTEGRAL GASKETED CLEANOUTS 6000X-1 BRONZE CLEANOUT PLUG, ADJUSTABLE HOUSING WITH SCORIATED SECURED PROVIDE ROUND NICKALOY TOP. CONTRACTOR SHALL PROVIDE CONCRETE PAD. REFER TO DETAIL PAD WALL CLEANOUT WADE ROUND STAINLESS STEEL WALL ACCESS COVER WITH CENTER SCREW, COATED CAST TEE WITH ACCESS 8560/8480R IRON CLEANOUT TEE WITH HUB AND SPIGOT CONNECTION AND RECESSED BRONZE COVER TAPPED PLUG. PROVIDE VANDALPROOF SCREW. REFER TO WALL CLEANOUT DETAIL NON-FREEZE WADE 3/4" NON-FREEZE WALL HYDRANT SHALL BE A ENCASED "ANTI-SIPHON" AUTOMATIC HOSE BIBB MODEL 8600 DRAINING WALL HYDRANT FOR FLUSH INSTALLATION. FURNISHED COMPLETE WITH NON-FREEZE INTEGRAL BACKFLOW PREVENTOR, BRONZE CASING, ALL BRONZE INTERIOR PARTS, NON TURNING OPERATING ROD WITH FREE FLOATING COMPRESSION CLOSURE VALVE. REFER TO ARCH. DWGS WALL THICKNESS. FURNISH COMPLETE WITH KEY LOCK AND "WATER" CAST ON COVER. NOTES: 1 2 3 4 5 6 7 8 9 10 WALL HUNG PLUMBING FIXTURES SHALL BE SUPPORTED USING ADJUSTABLE CONCEALED ARM FLOOR MOUNTED SUPPORTS WITH RECTANGULAR STRUCTURAL STEEL UPRIGHTS UTILIZING HEAVY-DUTY CAST-IRON FEET BOLTED TO THE FLOOR AND CAST IRON SUPPORT HEADERS. FLOOR AND HUB DRAINS IN RESTROOMS AND MECHANICAL ROOMS, ALSO DRAINS WHICH RECEIVE HVAC CONDENSATE AND DRAINS NOT FREQUENTLY USED SHALL HAVE AN AUTOMATIC TRAP PRIMER ACTIVATED BY A DROP IN WATER PRESSURE. TRAP PRIMER SHALL BE LOCATED DIRECTLY BEHIND A 10 INCH BY 10 INCH ACCESS PANEL FLUSH WITH WALL ACCESS PANEL, LOCATED AS DIRECTED BY THE ARCHITECT. ACCESS PANEL LOCATIONS SHALL BE COORDINATED WITH ARCHITECT PRIOR TO ROUGH-IN. ARCHITECT RESERVES THE RIGHT TO RELOCATE ACCESS PANEL PRIOR TO INSTALLATION WITHOUT ADDITIONAL COST. CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS AND LOCATIONS OF ALL PLUMBING FIXTURES INCLUDING HANDICAPPED (ADA) FIXTURES. CONTRACTOR SHALL COORDINATE ADA REQUIREMENTS WITH ARCHITECT PRIOR TO INSTALLATION OF PLUMBING FIXTURE. THE PLUMBING AND ARCHITECTS DRAWINGS. CONTRACTOR SHALL PROVIDE ADA FIXTURES AS SHOWN ON BOTH FLUSH VALVE FOR THE HANDICAPPED PLUMBING FIXTURES SHALL BE INSTALLED WHERE THE HANDLE FACES INTO THE OPEN AREA WITHIN THE STALL. (TOWARDS THE CENTER OF STALL) CONTRACTOR SHALL PROVIDE FLEXIBLE MOLDED INSULATION ON P-TRAPS, WATER SUPPLIES AND VALVES SERVING ADA PLUMBING FIXTURES. CONTRACTOR SHALL PROVIDE OFFSET P-TRAPS ON ADA FIXTURES CONTRACTOR SHALL INSTALL ALL PLUMBING FIXTURES SHOWN ON THE ARCHITECTURAL, KITCHEN, PLUMBING AND OWNER FURNISHED DRAWINGS. CONTRACTOR SHALL FURNISH AND INSTALL ON EACH PLUMBING FIXTURE CHROME PLATED BRASS P-TRAP, NIPPLES WITH ESCUTCHEON, CHROME PLATED BRASS ANGLE SUPPLIES WITH ALL METAL CONSTRUCTION CHROME PLATED FLEXIBLE BRASS RISERS WITH NIPPLES AND CHROME PLATED BRASS ESCUTCHEONS WITH CAST SET SCREW. CONTRACTOR SHALL PROVIDE ALL NECESSARY FITTINGS, PIPING, SUPPORTS, ETC. TO INSTALL EACH PLUMBING FIXTURE PER MANUFACTURER'S INSTALLATION INSTRUCTIONS AND TO COMPLY WITH CITY, STATE, ADA AND TAS CODES AND STANDARDS. CONTRACTOR SHALL REFER TO HVAC DRAWINGS AND PROVIDE ALL NECESSARY WASTE, VENT AND CW PIPING, ALSO VALVES AND FITTINGS REQUIRED TO INSTALL FLOOR AND HUB DRAINS RECEIVING CONDENSATE. FLUSH VALVES SHALL BE SIMILAR TO "SLOAN ROYAL" UNLESS OTHERWISE NOTED