Operating instructions Clock thermostat

Similar documents
Modulating clock thermostat

User Instructions For TopTronic RS-30

Roth Touchline. German quality since Quick and easy user manual 1/10

BM Programming Module. For the heating engineer Installation instructions

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Instruction FH-CWP Thermostat

danfoss Heating Solutions 5

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

Floor sensor (NTC) Temp (C o ) Value (kohm) 10 o C 19,9 kohm 15 o C 15,7 kohm 20 o C 12,5 kohm 25 o C 10,0 kohm 30 o C 8,0 kohm

RF Programmable Room Thermostat User Instructions

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

installation guide installation guide electronic intelligent timer thermostat

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

Installation Manual. Electric Underfloor Heating. heatingthroughinnovation.

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

Operating Instructions

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

AUS. Devireg TM 535 Installation and user manual

Settings and Maintenance of the CombinAir

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

CS027 User Instructions

Original instructions. Thermoplus PL RU

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

INSTALLATION INSTRUCTIONS

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

Boiler controller Lambdatronic S 3200

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

Roth Touchline. German quality since User manual quick and easy guide 1/10

Digital Room Thermostat

User Manual. Dryer Controller M720

SOLO User Guide. Description. Installation. Programmable Dual Voltage Thermostat 240 V (120 V)

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

Boiler controller S-Tronic Plus

Basic Plus2 Room Thermostats Floor Heating

Operating and Installation Manual VRC 430f. Weather compensator controller with radio transmission. For the operator / for the heating engineer

Battery Powered Electronic Programmable Room Thermostat

C-Stat 17-ZW User Instructions

For the owner and the heating engineer. Operating and Installation Manual. timeswitch 140. Two-channel 5/2 or 7-day full programmer

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

Floor heating controls, radio connection 1

Watts Under Floor Multi-zone Controller User Manual

Type UDG, UCG, UTN, USG

4 in 1 Digital Thermostat Control

Digital Thermostat Models: VS30W and VS30B

Installation and user manual

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

Model: RT510RF. Installation Manual

EFET 535. Installation Manual INT INT

ESRTP4RF. RF Programmable Room Thermostat with TPI, Optimum Stop, Delayed & Optimum Start. User and Installation Instructions

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

Condensing Boiler RS100 Controller Training Program

USER S MANUAL. Wired Remote Controller MWR-WS00. System Air Conditioner ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH EΛΛHNIKA RUSSIAN

Control solutions Biofloor

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

Electronic Pellet Burner Controller NPBC-V3M

NRG Control WARNING. Energy Saving Control for Combat Warm Air and Blackheat Radiant Heating Equipment Installation, Operation and Service Manual

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

Operating Instructions Model : HC HC-N

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.

XR401. Comfort Control TCONT401AN21MA. Owner s Manual. your local dealer (distributor) For more information contact. Tyler, Texas 75711

Thank you for buying a DEVI product. With this purchase you have obtained a product of the highest quality, designed to give long lasting comfort at

Dryer Controller M720

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

Programmable Towel Radiator Manual

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

MCD User Manual

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

User manual. CTS 602 by Nilan VPL 15 VPL 15 TOP. Version: 9.02, Software-version: 2.21

Operating instructions

PROGRAMMABLE 7-DAY RF THERMOSTAT

CentaurStat 7 User Operating Instructions Central Heating Programmable Room ThermoStat

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM OD (FOR EXTERNAL USE)

Programmable Thermostat

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

Operating Instructions

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

Model: Touch-RS. 1 Touch-RS

DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

FLOW CONTROLLER TYPE S/601

Installation & User s Instructions

SCS311 / SCS317 Installation Instructions

LCF Touch (from firmware version 1.7)

EasyTronic III MANUAL SERVICE

Transcription:

Operating instructions Clock thermostat DB8 / MTC optimising controller MTC-GB v02-02

1 Table of contents OPERATING INSTRUCTIONS 1 CLOCK THERMOSTAT 1 1 TABLE OF CONTENTS 2 2 DESIGNATED USE 3 2.1 SAFETY 3 3 DESCRIPTION OF THE THERMOSTAT 3 3.1 CONCISE SPECIFICATIONS 3 3.2 TECHNICAL SPECIFICATIONS 3 4 MOUNTING AND ELECTRICAL CONNECTION 4 4.1 MOUNTING 4 4.2 ELECTRICAL CONNECTION 4 4.3 ONE HEATER ON ONE CONTROLLER 4 4.4 SEVERAL UNITS ON 1 THERMOSTAT 4 5 SETTINGS 5 5.1 LANGUAGE 5 5.2 TIME/DATE 6 5.3 TEMPERATURES 6 5.4 CLOCK PROGRAM 6 5.4.1 Deleting programmed blocks 7 5.5 HEATING PROGRAM 7 6 VENTILATION 7 7 OVERTIME TIMER 8 8 OPTIMISER 8 9 KEYBOARD LOCKING 8 9.1 UNLOCK THE DISPLAY 9 10 DISPLAY 9 11 CALIBRATING THE THERMOSTAT 9 12 DESTRATIFICATION (DELAT T REGULATION) 10 13 BACK TO FACTORY DEFAULT SETTINGS 10 14 REMOTE SENSOR 11 14.1 ELECTRICAL CONNECTION: 11 14.2 SETTING THE CONTROLLER FOR THE REMOTE SENSOR 11 14.3 AVERAGE TEMPERATURES 12 14.4 SETTING UP THE REMOTE SENSOR 12 14.5 ERRORS WITH THE REMOTE SENSOR 12 15 SOLVING AND ANALYSING FAILURES 12 16 OBTAINING EXTRA INFORMATION FROM THE CONNECTED HEATERS 12 17 INSTALLER MENU 13 18 INTERNAL BATTERY 14 19 MAINTENANCE AND SERVICE 14 19.1.1 Waste processing 14 Room thermostat DB8 / MTC 2/14

2 Designated use The Multi Therm-C clock thermostat has been designed to control room heaters that work according to the Argus bus system. This is a two-wire low voltage communication system. The thermostat is not suitable to switch 24V, 230V or other signals. It may only be used in dry rooms with slight impurities (degree of protection IP30). Before use, carefully read these operating instructions and observe them. In case the mounting and operating instructions are not observed, the manufacturer s warranty will not apply to any resulting damage. 2.1 Safety Electrical devices may only be connected by a qualified electrician. Always observe the relevant national regulations. Interferences and changes to the device will lead to cancellation of the warranty. 3 Description of the thermostat 1. Display 2. Info button to display information 1 3 5 3. Menu button to enter and exit the 4. OK button to confirm a setting 5. + and buttons to raise or lower 6. openings for the temperature sensor 2 4 5 6 3.1 Concise specifications Room thermostat with clock function Optimising controller Permanent display of the room temperature 10 different programmable time blocks Up to 8 heaters controllable Frost protection Keyboard locking Overtime program Ventilation Failure diagnosis of the devices Suppression of interference of the heater Compensation for wall influence suited for remote sensor Supplied battery, excellent for preserving data in case of power failure 3.2 Technical specifications Power supply: low-voltage current Temperature range: 0-30 degrees Celsius Controller: PI Clock: 10 programmable switch blocks Degree of protection: IP30 Room thermostat DB8 / MTC 3/14

4 Mounting and electrical connection 4.1 Mounting The clock thermostat is suitable for mounting in dry, not too dusty rooms. Place the thermostat in a room in a location where air can circulate unimpeded. Beware that in winter the low-standing sun cannot shine directly onto the thermostat. Placement above or near a device that radiates heat is also not recommended. Avoid placement on a cold outdoor wall; place the thermostat on an indoor wall free of draught. All these things have an adverse effect on the correct measurement of the room temperature and hence on the proper operation of the thermostat. By pressing the notch on the bottom of the thermostat, you can open the thermostat. The bottom plate containing the connector can be mounted on a universal wall box or directly on the wall. Be ware that the controller should not be mounted near a anennas from any internal communication network. These antennas may disturb the correct functioning of the controller. Always keep a few meters distance. 4.2 Electrical connection To connect the thermostat, always ensure that the heating device has been shut down. The thermostat receives electric power from the heating device. The connection is 2-wire low-voltage and is not phase sensitive, i.e. it does not matter how the wires are connected. Beware that the thermostat wires do not run through the same circuit as 230 volt wires and are not parallel with high-voltage current wires. If the wires are longer than 20 metres or run through an environment where there is a great deal of EMC radiation, a low-noise cord is recommended. This can, for example, be a wire with an earthed sheathing. Cable length: 0 50 m - min. 0,13 mm2 50 100 m - min. 0,25 mm2 100 250 m (max.) - min. 0,50 mm2 The given length is the maximum distance between the controller(s) and the heater(s). 4.3 One heater on one controller Standard nothing needs to be changed in the heating device. In case the thermostat does not work, check that the micro-switches S2 on the print plate in the room heater are set as shown on the right: number 1 up (ON) and the other numbers down. The switch S3 should be set to 1. In case ON S2 6 7 8 0 S3 1 several devices are connected to 1 thermostat, refer to the relevant chapter in this manual. This thermostat is only suitable for connection to heating devices specifically intended for this purpose. Never connect, for example, 24V or another voltage of another system to the thermostat. This can damage the thermostat. After making the changes inside the heater always unplug and re plug the power to the heater for the changes to become effective. Installer 4.4 Several units on 1 thermostat ON 0 1 6 7 8 Heater 1 The room thermostat can control up to 8 room heaters. Connecting them is simple, but it should be done properly. Pay attention to the following: ON 6 7 8 0 1 Heater 2 ON 0 1 Each unit must be given its own number (to be set with the micro-switch S2 in the unit). 6 7 8 Heater 3 One unit must have the S2 number 1 set on ON (this unit provides for the communication) and S3 to 1, al the other heaters should have S3 set to 0. S2 S3 Thermostat (bus) 22 C Room thermostat DB8 / MTC 4/14

Between the separate units, the numbers 4 must be connected with the numbers 4 and the number 5 with 5. They must not be connected in a cross-wise manner. The functionality of the thermostat does not change by connecting a number of room heaters. Heater 1 Heater 2 Heater 3 Heater 8 Max. 8 Heaters Communicatie bus: 2 draads; laagspanning 22 C Heater 1 Heater 2 Heater 3 beware that the thermostat wires do not run through the same circuit as 230 volt wires and are not parallel with high-voltage current wires. If the wires are longer than 20 metres or run through an environment where there is a great deal of EMC radiation, a low-noise cord is recommended. This can, for example, be a wire with an earthed sheathing. 22 C Cable length: 0 50 m - min. 0,13 mm2 50 100 m - min. 0,25 mm2 100 250 m (max.) - min. 0,50 mm2 The given length is the maximum distance between the controller(s) and the heater(s). 5 Settings 5.1 Language You can change the language of the various items of the thermostat. To change the language of the thermostat, observe the following procedure. 1. Activate the with the M button. Select and confirm with OK. 2. Select language and confirm with OK. calibration language DeltaT active 3. Select the correct language and confirm with OK. Exit the by pressing M twice. language Deutsch English Francais Room thermostat DB8 / MTC 5/14

5.2 Time/date 1. Activate the with the M button. Select and confirm with OK. 2. Select time/date and confirm with OK. 3. Change the with the + and buttons and each time confirm with OK. To exit the, press M twice. Settings Heating prog. time/date Clock program Time /date Time 14:34 Date 01-04-2006 Mo 5.3 Temperatures During the clock program, the thermostat works with 3 temperature levels in a room: Day, Night and Frost temperature. These levels can each be set from 0 to 30 degrees Celsius. This allows you to set the desired temperature quickly when programming the clock program. Comment. For the sake of ease, the names day, night and frost have been chosen. You are free to set the temperature levels at any desired time and on any desired value between 0 and 30 degrees. To set the temperatures: 1. Activate the with the M button. Select and confirm with OK. 2. Select temperatures and confirm with OK. Settings DeltaT active temperatures Heating prog 3. Set the desired temperatures from 0 to 30ºC. Confirm with OK. Exit the by pressing M twice. temperatures day 20.5ºC night frost 15.0ºC 6.0ºC 5.4 Clock program You can program 10 time blocks in the thermostat. A time block is for example: Every Monday at 7.00 day temperature; and at 17.00 night temperature. 1. Activate the with the M button. Select and confirm with OK. 2. Select clock program and confirm with OK. time/date clock program Optimiser Room thermostat DB8 / MTC 6/14

3. Go through the different programmed blocks with the + and buttons. By pressing OK you can change the selected block. Program Block 1 Mo Tu We Th Fr 07:00 day 17:00 night For days there are various options: off Mo Tu We Th Fr Sa Su Mo Tu We Thu Fr Sa Su Mo Tu And further... When the block has been filled in correctly, press OK to save the block. 5.4.1 Deleting programmed blocks When selecting day, you can also select the off option. In that case the of the block are deleted. Program Block 1 Off 5.5 Heating program This thermostat can work in different ways. Naturally, it can work automatically on the clock, but also in other ways. Cont. day The thermostat maintains the programmed day temperature; the temperature is not lowered. However, you can change the temperature manually. Cont. night The thermostat maintains the programmed night temperature; the temperature is not raised. However, you can change the temperature manually. Cont. frost The thermostat maintains the programmed frost temperature; the temperature is not raised. However, you can change the temperature manually. Clock program The thermostat maintains the clock program. You can still change the set point manually, the set point will return to its automated value at the program step of the clock. 1. Activate the with the M button. Select and confirm with OK. 2. Select time/date and confirm with OK. temperatures heating prog time/date 3. Change the with the + and buttons and each time confirm with OK. To exit the, press M twice. 6 Ventilation With some devices it is possible to control the ventilator without the heater being on. In summer this can, for example, have a cooling effect. The ventilator can be switched to 4 positions: position 1, 2, 3 and off. Setting the ventilation: 1. Activate the with the M button. With the + and buttons select ventilation and confirm with OK. Heating prog Cont. frost Clock program Cont. day overtime program ventilation Room thermostat DB8 / MTC 7/14

2. With the + and buttons select the ventilator position and confirm with OK. Exit the by pressing M. Ventilation Off 1 2 3 7 Overtime timer When the thermostat is set on the clock and you would like temporarily to maintain the temperature longer on day level, you can do so with the overtime timer. The overtime timer can be set per 15 minutes. 1. Activate the with the M button. Select overtime program and confirm with OK. overtime program ventilation 2. With the + and buttons enter a time in steps from 15 min., and confirm with OK. The time will start to count down immediately. Overtime 01:15 8 Optimiser the controller can be set in such a way that it will start the heaters earlier by means of a optimising program. The controller calcultes when the heaters should be started in order to reach the setpoint temperature at the desired time. De optimiser can be set by:t 1. Activate the with the M button. Select and confirm with OK. 2. Select Optimiser and confirm with OK. Clock program Optimiser display 3. Change the with the + and buttons and each time confirm with OK. To exit the, press M twice. Optimiser On Off After setting the optimeser it will take several days for the controller to gathered the information needded for the calulations. When the controller is confronted with sudden colder or warmer nights it wll not take this in its calculations inmediately. When the temperatures are lower for a few days it will adjust its calculations. Remark: The maximum time that the heaters will start earlier is 3 hours, and the earlier start is not overnight. 9 Keyboard locking It may be handy to secure the thermostat in whole or in part against unauthorised changing of the. There are several levels of security: Unlocked. Fully locked. Limited, with only the overtime timer. Room thermostat DB8 / MTC 8/14

Setting the : 1. Activate the with the M button. With the + and buttons select and confirm with OK. ventilation 2. With the + and buttons select the desired level and confirm with OK. Exit the by pressing M. Keyboard locking On excl. overtime On Off The locking becomes active as soon as OK is pressed. The message appears in the display as soon as a button is pressed. 9.1 Unlock the display The thermostat can be unlocked by: Pressing the M button for at least 10 seconds. 10 sec 10 Display The thermostat can arrange the display in various ways. 1. Activate the with the M button. Select and confirm with OK. 2. Select display and confirm with OK. Optimiser display calibration 3. Change the display with the + and buttons and confirm with OK. To exit the, press M twice. 14:06 Disp 1 21.5ºC 21.5ºC Disp 2 14:06 Disp 3 14:06 21.5ºC Setpoint 22.0ºC 11 Calibrating the thermostat Under unfavourable circumstances, variations can occur between the actual temperature and the displayed temperature. This may be caused by assembly to an outdoor wall, irradiation of the sun, monitors, etc. This temperature difference can be compensated for by means of a calibration function. Example: The difference between the measured value and the displayed value is 2ºC, i.e. the displayed value is 2ºC too high. The correction value is therefore -2ºC. 1. Activate the with the M button. Select and confirm with OK. Room thermostat DB8 / MTC 9/14

2. Select calibration and confirm with OK. display calibration language 3. Change the with the + and buttons and confirm with OK. To exit the, press M twice. calibration Temp. difference -2.0 12 Destratification (delat T regulation) Warm air wants to go up and stay under the ceiling of the room. The heater has the ability to push this warm air back to the ground, and spread it into the room. This is called destratification or delta T regulation. The thermostat measures the temperature on ground level and reads the temperature above in the room from the sensors on the heater. When the temperature difference between the ceiling and ground level the ventilator inside the heaters will start to push the warm air down. (factory default 12 C. When this regulation is active the heater wil also stop to burn until this temperature is leveled. The destratification can be set by: 1. Activate the with the M button. Select and confirm with OK. 2. Select deltat active and confirm with OK. Language DeltaT active Temperatures 4. Change the with the + and buttons and confirm with OK. To exit the, press M twice. DeltaT active ON Off In the special the parameters of this dela T regulations can be changed. For example the temperature difference when the fan should start and stop can be changed. See for this in the chapers from the. 13 Back to factory default In case the thermost needs to become its factory default back it can be done with: Press the OK button for 10 seconds and confrm with OK. 10 sec RESET ALL? All are lost and the default language wil show. Room thermostat DB8 / MTC 10/14

14 Remote sensor In some cases it is applicable that the temperature is measured on another place than the controller is suited. In that case a remote sensor can be plugged on the same 2 wires as the heaters and the controller. The controller then works with the temperature from the seperate remote sensor. It is also possible that the contriller takes the average between its own internal sensor and the remote sensor. 14.1 ELECTRICAL CONNECTION: The sensor should be connected according to the diagram as shown. The sensor is connected through a 2-wire low voltage communication system, the Argus Link. Maximum 8 heaters can be connected on this system. Cable length: 0 50 m - min. 0,13 mm2 50 100 m - min. 0,25 mm2 100 250 m (max.) - min. 0,50 mm2 The given length is the maximum length between the thermostats and the heaters. To connect the sensor, always ensure that the heating device has been shut down. Connect the sensor on the same wires as the clock thermostat. See Figure. Make sure the cable of the thermostat is not parallel to a 230 Volt cable. Thermostat Thermostaat Termostato Termostat 22 C 22 C Remote sensor Externe sensor Sonde distance Abstandsfüler Sensore remoto Czujnik zewnet Dalkovy senzor Nuotol. jutiklis 14.2 Setting the controller for the remote sensor The in the controller schould be canged so that it can see the remote sensor. 1. Activate the by pressing the M button and select Installer, and press OK. Menu Settings Installer overtime program 2. A security code is asked. By means of the + and buttons fill in the code 0.5.4.3. and confirm with OK. code 0.5.4.3 3. Select the option remote sensor and confirm with OK. DeltaT2 control remote sensor View mode only Room thermostat DB8 / MTC 11/14

4. Change the with the + an buttons and confirm with OK. Exit the by pressing the M button 2 times. 14.3 Average temperatures The controller can also calculate the average between its internal sensor and the remote sensor. Selecte the option Average for that. 14.4 Setting up the remote sensor The remote sensor is ready to use. When the sensor does not work correctly the in the sensor can be checked. SETTINGS By pushing the left arrow button for 5 seconds the will open. The display shows intermittent P01 - P04 and the set value. By pushing the left arrow button again, other parameters will become visible. The parameter can be shut by pushing the right button. Remote sensor used not used Average P01 calibration of the sensor. Under bad circumstances, differences between actual temperature and shown temperature can occur. This can be caused by mounting on an external wall, sunshine, monitors etc.. This temperaturedifference can be compensated by this parameter. Example: The difference between the measured value and the shown value is 2ºC, i.e. the shown value is 2ºC too high. The value to set will then be -2ºC. This can be done by pushing the + and - button. P02 Not used P03 Not used P04 Standard value for the remote sensor is 1. When this is not 1 it has to be changed. 14.5 Errors with the remote sensor In the case that te controller sees an error regarding the remote sensor it will show an error on the display. When there is no sensor found it will show error 3 When the senor is found but is not set up correctly it will show error 4 15 Solving and analysing failures When one or more heater(s) has an error message, it appears on the display of the thermostat. By pressing the Info button, you can obtain more information about the error message. With the + and buttons, you can select different heaters if connected. When, for this error message, resetting the room heater is an option, this also appears in the display. You can reset the heater by pressing OK. Thermostat Error 4 20,5 ºC Heater 1 XR NG ADJ. Error A1 (1) IGNIT ERROR Reset heater NOTE: If a room heater frequently goes on failure, do not continue to reset; this can damage it. Let a recognised examine the room heater. 16 Obtaining extra information from the connected heaters When the info button is pressed for 5 seconds a special information is showed. By pressing the + or button the status of all the connected heaters can be checked. By pressing the Info button again more information about the selected heater will appear. The information will be shown in the English language. To exit the information press the M button. Room thermostat DB8 / MTC 12/14

Info Screen 1 Heater 1 XR NG 10kW line 1: shows the discription of the connected heater STANDBY_0 line 2: shows the status of the heater Tcy Ttop 23 line 3 and 4: shows the temperatures from the Tx1 22 Tx2 22 internal sensors. Ycy = flue temperature if the sensor is fitted (optional) Ttop: temperature of the air where the heater is located. Tx1 and Tx2: Temperatures from the sensor mounted on the heatexchanger info screen 2 line 1: shows the discription of the connected heater line 2: shows the status of the heater line 3 and 4: Ion = ionisation level 0-90 Ac = actual speed or the burnerfan Sf = actual modulation level of the system fan 0-255 Mi = minimum speed of the burnerfan Ig = ignition speed of the burnerfan Ma = maximum speed of the burnerfan When no heaters are found or connected, the following display will show. Also when the connedted heaters do not have the right setting of the switches S2 and S3 the controller will show this display, because he can not communicate with the heaters. Heater 1 XR NG 10kW STANDBY_0 Ion 0 Ac 0 SF 0 Mi3480 Ig4740 Ma6000 Heater 1 N.C. 17 Installer The functioning of the heater and the controller can be changed by changing the parameters in the. 1. Activate the by pressing the M button and select Installer, and press OK. 2. A security code is asked. By means of the + and buttons fill in the code 0.5.4.3. and confirm with OK. Menu Settings Installer overtime program code 0.5.4.3 3. Select the different options available and confirm with OK. DeltaT2 control remote sensor View mode only The following options are available Delta T Hystereses (standard values UP 12 and Down 8.0) The temperature difference when the system fan turns on and off can be set here. The UP value is the temperature difference between the temperature down on the thermostat, and the temperature above at the heater, when the system fan should start the destratification. The down value is the value when the fan should stop the destratification. Heater Modes (standard value Heater full) In exceptional cases it might occur that a total modulation of the heater is not desired. This can be set with this parameter. The burner and fan work Room thermostat DB8 / MTC 13/14

Heater full (fully modulatin) Heater high (Only on high position) Heater mid (Only on middle position) Heater low(only on low position) Heater low&mid (Low and middle position) Heater mid&high (Middle and high position) Remote sensor Used Not used (standard) Average View mode only. With this option the controller can be used as a monitoring divice. The temperature control system is disabeled. The special information is available for monitoring the connected heaters. On Off (standard) Only the info button can be used. To exit the view mode the M button has to be pressed for 10 seconds (like keyboard lock) and then the from view mode in the have to be changed. DeltaT2control NOT used (standard on OFF) DeltaT2hystereses NOT used (standard values up 4 down 2) I Factor Do not change this value (standard 5 min) only change this after contacting your supplier. 18 Internal battery When the thermostat is connected to the room heater, it does not use power from the internal battery. This battery only serves to allow the internal clock to run on in case of a power failure. The programmed data always remains in memory. This means that the battery, too, will stand years of use. When the battery is empty, the clock of the thermostat will be on 00:00 after a power failure of the room heater that has number 1. If it is necessary to replace the battery: Click the top of the thermostat loose from the wall plate. Use a flat screwdriver for this and push it into the opening on the bottom of the thermostat. Carefully prise the print plate out of the top of the thermostat using a flat screwdriver. See picture. Carefully prise the print plate out of the holder (see picture). Then prise the battery out of the holder and insert a new battery. Click the thermostat back together again. Note: Do not dispose the battery in your regular household waste. Dispose it separately in accordance with national guidelines. 19 Maintenance and service Under normal use, the thermostat requires no maintenance. In a very dusty environment it may be necessary to clean the ventilation openings of the temperature sensor. Clean the device exclusively with a dry or moist lint-free cloth. Beware of moisture inside the device. 19.1.1 Waste processing At the end of the life cycle, the thermostat should be disassembled by an expert and processed in an environmentally-friendly way in accordance with the relevant national regulations. Do not dispose the battery in your regular household waste. Dispose it separately in accordance with national guidelines. Room thermostat DB8 / MTC 14/14