Operating instructions

Similar documents
Operating instructions

Operating Instructions

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user

Operating instructions

Operating instructions

Operating instructions Oil condensing boiler

VIESMANN. Operating instructions VITODENS 100-W. for the system user

/2010 US/CA

Installation and maintenance instructions

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

Installation instructions

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

Installation and maintenance instructions

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

User manual. Logano GC 124 II. Gas boiler

VIESMANN. Operating instructions VITODENS 111-W. for the system user

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

Operating instructions

Operating instructions

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

Operating instructions

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Operating instructions

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

ecotec pro Operating instructions Operating instructions For the operator GB, IE Gas-fired wall-hung high-efficiency boiler

Operating instructions

VIESMANN. Operating instructions DIGITAL TIME SWITCH. for the system user. Digital time switch for the Vitodens 100-W, type WB1B

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C

USER'S INFORMATION MANUAL

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

User s Information Manual

WHE 2.24 / WHE 2.24 FF

Installation and maintenance instructions

User s Information Manual

User s Information Manual Models: 45, ,000 Btu/hr

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

Tankless Water Heater

Service instructions. FM443 solar module. Function module. For contractors. Read carefully prior to commissioning or service

User s Information Manual

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

Installation and maintenance instructions

Installation and maintenance instructions for contractors

ecotec plus boiler user guide

Operating instructions. For the operator. Operating instructions. ecotec. Gas fired wall hung high efficiency boiler.

E-COMBI EVO E-SYSTEM EVO

GOLD. User s Information Manual. Water Boiler Series 4

Bosch 80% AFUE Gas Furnace BGS80 Model

User s Information Manual

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

User's Infomation Manual

Model BW9 Gas-Fired Direct Vent Condensing Water Boiler

Installation and Service Instructions Logano G234X

Installation and maintenance instructions

User s Information Manual

Ignition Burner Maintenance

User s Information Manual

USER'S INFORMATION MANUAL

ir-range 8G /03.15 Changes reserved.

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

Universal Fire Tube Boiler Wall Mount Models

Service Instructions. Logamax plus GB kw/100 kw. Condensing gas boiler. For the contractor

USER'S MANUAL PGE Single Package Rooftop

Residential Gas Hybrid Water Heater

Greenstar 12i system / 24i system

TO DO IF YOU SMELL GAS

User s Information Manual

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

User s Information Manual

USER'S INFORMATION MANUAL

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

Operating instructions

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

Installation and Service Instructions LoganoUS/CA GC 144 II

GB162 Concentric Horizontal Vent Kit

Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

USER'S INFORMATION MANUAL

Operating Instructions. VITODENS r 200 Series With Vitotronic 200 HO1B Controls WARNING WARNING IMPORTANT

WHAT TO DO IF YOU SMELL GAS

GOLD CGt. User s Information Manual. Natural gas-fired water boiler with tankless heater

INSTRUCTION FOR THE USER THC V E OIL BLU

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

USERS GUIDE. LOGIC+ Combi 24, 30, 35

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

USER'S INFORMATION MANUAL

User Manual for model

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Fig. 1 - Unit PGD4, PGS4, WPG4

User s Information Manual Models: ER152, ER202, ER252, ER302, and ER402

Logic+ Combi

Room-temperature (economy/night) unit TR 212 E

GWC. User s Information Manual. Gas-Fired Water Boilers. Model

USER'S INFORMATION MANUAL

Cast Iron Commercial Hot Water Or Steam Boiler

Owner s Information Manual

Greenstar 12i/24i System

User Manual for model

Transcription:

Operating instructions Gas-fired condensing boiler Logano plus GB312 For the user Please read carefully before use 7 747 009 296-01/2007 EN

Contents 1 For your safety.............................................. 3 1.1 About this manual............................................ 3 1.2 Correct use............................................... 3 1.3 Key to symbols............................................. 3 1.4 Please observe these instructions................................... 3 1.4.1 If you smell gas.......................................... 3 1.4.2 Instructions for the boiler room.................................. 4 2 Product description........................................... 5 2.1 Components on the Logano plus GB312 boiler........................... 5 2.2 Controls on the BC10.......................................... 6 3 Operating the heating system.................................... 7 3.1 Switching on the heating system................................... 7 3.1.1 Starting the heating system via the control panel and programming unit............ 7 3.2 Switching off the heating system................................... 8 3.3 Emergency measures......................................... 8 3.4 Checking the operating pressure, topping up with heating water and bleeding the system... 8 3.4.1 When do you need to check the operating pressure?...................... 8 3.4.2 Checking the operating pressure................................. 9 3.4.3 Topping up heating water and bleeding the system....................... 9 3.5 Why is regular maintenance important?.............................. 11 4 Troubleshooting............................................ 12 4.1 Recognising and rectifying faults.................................. 12 Operating pressure Use this fuel only: Design operating pressure (optimum value): bar Maximum heating system operating pressure: (standard = 3 bar) bar stamp/date/signature 2 Gas-fired condensing boiler Logano plus GB312 - Technical specifications are subject to change without prior notice.

For your safety 1 1 For your safety 1.1 About this manual These instructions contain important information for the safe and correct operation of the boiler. In the following, the Logano plus GB312 will generally be referred to as "the boiler". 1.2 Correct use The boiler may only be used for heating water for the purposes of central heating or domestic hot water (DHW), in homes or apartment buildings. 1.3 Key to symbols The following symbols are used in these instructions: WARNING! RISK TO LIFE Indicates a possible danger which can lead to serious injuries or even death if appropriate care is not taken. RISK OF INJURY/ SYSTEM DAMAGE Indicates a potentially dangerous situation which could lead to minor or moderately serious injuries or to damage to property. USER NOTE User tips for optimum utilisation and setting of the equipment, plus other useful information. Cross-references Cross-references to a specific point in the document or to other documents are marked with an arrow. WARNING! RISK TO LIFE if personnel are not qualified. Make sure that installation, initial startup and maintenance are carried out only by professional heating technicians. Appropriate qualifications are particularly necessary for work on electrical and fuel-carrying parts. 1.4.1 If you smell gas WARNING! RISK TO LIFE through the explosion of flammable gases. If you can smell gas, there is a risk of explosion. No open flames. No smoking. Do not use lighters. Prevent sparks. Do not activate any electrical switches, including telephones, plugs or electrical bells. Close the main gas shut-off valve. Open windows and doors. Warn all occupants, but do not use doorbells. Leave the building. Call your local gas supplier and heating contractor from outside the building. If necessary, notify police or fire services. If you hear gas escaping, evacuate the affected area immediately. 1.4 Please observe these instructions You will learn how to use your heating system by arranging for your local heating contractor to instruct you after installing the system and carefully reading these operating instructions. Carry out tasks on the boiler only as described in these operating instructions. Gas-fired condensing boiler Logano plus SB735 - Technical specifications are subject to change without prior notice. 3

1 For your safety 1.4.2 Instructions for the boiler room WARNING! RISK TO LIFE from poisoning. In open-flue operation, insufficient ventilation can lead to dangerous flue gas leaks. Never close or obstruct air duct or vent apertures, or reduce their size. Keep the doors of the boiler room closed. Prevent small animals from entering the boiler room and in particular the air supply apertures, e.g. by means of an air grille. The boiler must not be operated until the problem has been remedied. WARNING! RISK OF FIRE due to flammable materials or liquids. Ensure that there are no flammable materials or liquids in the immediate vicinity of the boiler. 4 Gas-fired condensing boiler Logano plus SB735 - Technical specifications are subject to change without prior notice.

Product description 2 2 Product description 2.1 Components on the Logano plus GB312 boiler The boiler is a gas-fired condensing boiler with an aluminium heat exchanger. 1 2 3 The boiler consists of the following: Control panel Frame and casing Boiler block with lagging Gas burner 8 7 6 The control panel monitors and controls all electrical components of the boiler. 5 The boiler block transfers the heat generated by the burner to the heating water. The lagging reduces energy loss. 4 The design and operation of this product conforms to European Directives and the supplementary national requirements. Its conformity is confirmed by the CE marking. You can view the Declaration of Conformity on the internet at www.buderus.de/konfo or request a copy from your local Buderus office. Fig. 1 Logano plus GB312 boiler 1 Control panel 2 Gas burner 3 Boiler front panel 4 Siphon 5 Boiler block with lagging 6 Burner control unit 7 Gas train 8 Boiler casing Logano plus GB312 gas-fired condensing boiler - Technical specifications are subject to change without prior notice. 5

2 Product description 2.2 Controls on the BC10 USER NOTE For more information on operation, see the documentation for the BC10 base controller. 2 3 4 5 6 1 12 11 10 9 8 7 Fig. 2 Pos. 1: Pos. 2: Pos. 3: Pos. 4: Pos. 5: Pos. 6: Controls on the BC10 base controller ON/OFF switch Rotary selector for DHW temperature "DHW heating" LED Status display screen Rotary selector for maximum boiler temperature during heating mode "Heat demand" LED Pos. 7: Base plate with a slot for a programming unit e.g. RC30 (behind the cover) Pos. 8: "Burner" LED (on/off) Pos. 9: Diagnostic plug Pos. 10: "Status display" button Pos. 11: "Chimney sweep" button for flue gas test and manual mode Pos. 12: "Reset" button 6 Logano plus GB312 gas-fired condensing boiler - Technical specifications are subject to change without prior notice.

Operating the heating system 3 3 Operating the heating system 3.1 Switching on the heating system Before switching on, ensure that: The operating pressure is high enough The fuel supply has been opened at the main shut-off valve The heating system emergency stop switch is switched on 3.1.1 Starting the heating system via the control panel and programming unit Set both rotary selectors on the control panel to "AUT" (automatic mode). The programming unit takes control of the panel in this setting. Switch on the ON/OFF switch (position "1"). The control panel checks the current status of the system, and the burner may start up. When the boiler detects heat demand, the start program begins and the burner fires after about 30 seconds. Heat demand arises when the central heating or DHW temperature falls below the set value. The LED below the corresponding rotary selector will light up. Fig. 3 Setting the control panel Check the following settings on the programming unit and adjust as required: Automatic operating mode Desired room temperature Desired DHW temperature Desired heating program USER NOTE Information on operation, e.g. setting the temperatures, can be found in the documentation for the programming unit. Fig. 4 Fig. 5 Switching on the heating system Programming unit (e.g. RC30, with flap open) Logano plus GB312 gas-fired condensing boiler - Technical specifications are subject to change without prior notice. 7

3 Operating the heating system 3.2 Switching off the heating system Switch off the ON/OFF switch on the control panel (position "0"). This switches off the boiler and all its components (such as the burner). Close the main fuel shut-off valve. SYSTEM DAMAGE from freezing. When the heating system is switched off, it can freeze up in cold weather. Leave the heating system permanently switched on as much as possible. Protect your heating system from freezing by draining the pipework for central heating and DHW at the lowest possible point. 3.3 Emergency measures In the event of an emergency, e.g. a fire, proceed as follows: Close the main fuel shut-off valve. Isolate the heating system from the power supply using the heating system emergency stop switch or the relevant domestic fuse. 3.4 Checking the operating pressure, topping up with heating water and bleeding the system 3.4.1 When do you need to check the operating pressure? Newly added heating water loses much of its volume in the first few days because it releases gases. This causes air pockets, and the heating system will start to rumble. With new heating systems, check the operating pressure daily at first, topping up heating water and bleeding the radiators if needed. Later, check the operating pressure monthly, topping up heating water and bleeding the radiators if needed. 8 Logano plus GB312 gas-fired condensing boiler - Technical specifications are subject to change without prior notice.

Operating the heating system 3 3.4.2 Checking the operating pressure Your heating contractor has set the red needle of the pressure gauge to the required operating pressure (at least 1 bar). You can check the design operating pressure for this heating system on page 2. Check whether the pressure gauge needle is within the green field. If the pressure gauge needle falls below the green field, top up the heating water. 3.4.3 Topping up heating water and bleeding the system 2 1 3 Ask your heating contractor to show you where the boiler fill & drain valve for topping up the heating water is located on your heating system RISK TO HEALTH from contamination of drinking water. Ask your heating contractor to show you how to fill your heating system with water. Always observe the regulations and standards applicable in your country for the prevention of contamination of drinking water (e.g. by water from heating systems). In Europe, observe standard EN1717. Fig. 6 Pressure gauge for sealed systems 1 Red needle 2 Pressure gauge needle 3 Green field SYSTEM DAMAGE through temperature stresses. Temperature stresses can cause cracks if you fill your heating system when it is hot. The boiler will leak. Only fill the heating system when it is cold (the flow temperature should be no more than 40 C). Fill the heating system slowly via the filling valve (preexisting or fitted by customer). Watch the display (pressure gauge) as you do so. Once the desired operating pressure is reached, stop the procedure. Bleed the heating system via the bleed valves on the radiators. Top up with water if the pressure drops as a result of bleeding the system. Logano plus GB312 gas-fired condensing boiler - Technical specifications are subject to change without prior notice. 9

3 Operating the heating system SYSTEM DAMAGE from frequent top-ups. If you need to top up the heating water frequently, the heating system might be damaged by corrosion or scaling, depending on the water quality. Ask your heating contractor if you can add your local water without treating it, or whether it may need to be treated first. Notify your heating contractor if you often need to top up with additional water. The right fuel This heating system requires fuel of the correct type and grade to ensure its proper operation. SYSTEM DAMAGE from the wrong fuel. Use only the fuel specified page 2. Consult your heating contractor if you want to switch over your heating system to a different fuel or operate it with a fuel with different technical specifications. Boiler room BOILER DAMAGE from contaminated combustion air. Never use chlorinated cleaning agents or halogenated hydrocarbons (such as those contained in spray cans, solvents or cleaning agents, paints and adhesives). Prevent heavy accumulations of dust. SYSTEM DAMAGE from water. In case of an acute risk of flooding, disconnect the boiler from its power supply and shut off the fuel supply before water enters the boiler room ( section 3.2, page 8). If water has entered your heating system, have it checked by a professional technician before starting it up again. Any valves, controllers and regulating equipment that have come into contact with water must be replaced by a professional technician. 10 Logano plus GB312 gas-fired condensing boiler - Technical specifications are subject to change without prior notice.

Operating the heating system 3 3.5 Why is regular maintenance important? Heating systems require regular maintenance for the following reasons: To achieve a high level of efficiency and to operate the system economically (low fuel consumption) To achieve a high level of operational reliability To maintain the cleanest possible combustion SYSTEM DAMAGE from lack of cleaning and maintenance or incorrect cleaning and maintenance. Have your heating system inspected, cleaned and serviced once a year by professional technicians. We recommend you sign a contract covering annual inspections with maintenance on an as-required basis. Logano plus GB312 gas-fired condensing boiler - Technical specifications are subject to change without prior notice. 11

4 Troubleshooting 4 Troubleshooting 4.1 Recognising and rectifying faults In case of a fault, the fault code will flash on the control panel display. The programming unit shows faults as plain text messages. A fault exists if the display flashes and indicates something other than the current boiler water temperature or an operating message. Example: "6A" = the burner will not start Press and hold down the "Reset" button for about 5 seconds to clear the fault. The display shows "re" while the reset is implemented. A reset is only possible when a fault message is flashing on the display. The fault is cleared when the display shows a normal operating message again. Should the fault recur, repeat the reset two or three times. If the fault cannot be reset: Note down the fault message and notify your heating technician. SYSTEM DAMAGE from freezing. When the heating system has been shut down due to a fault, it can freeze up in cold weather. Immediately rectify the fault and restart the heating system. If this is not possible, protect your heating system from freezing by draining the pipework for central heating and DHW at the lowest possible point. Fig. 7 Clear the fault with the "Reset" button For more information on possible faults, see the documentation for the control panels. 12 Logano plus GB312 gas-fired condensing boiler - Technical specifications are subject to change without prior notice.

Notes Logano plus GB312 gas-fired condensing boiler - Technical specifications are subject to change without prior notice. 13

Notes 14 Logano plus GB312 gas-fired condensing boiler Technical specifications are subject to change without prior notice.

Notes Logano plus GB312 gas-fired condensing boiler - Technical specifications are subject to change without prior notice. 15

Buderus Cotswold Way, Warndon, Worcester WR4 9SW Tel.: 01905 752794 Fax: 01905 753130 www.buderus-commercial.co.uk BBT Thermotechnik GmbH D-35573 Wetzlar www.heiztechnik.buderus.de info@heiztechnik.buderus.de