u n i v e r s a l c o m f o r t Precision air-handling cabinets CIATRONIC System Ultimate precision air-conditioning NA 05.93 C
> > CIATRONIC System Precision air- > CIAT, European leader in air-conditioning CIAT's unique expertise is backed up by over 70 years experience, including 30 years in computer cabinets. With 9 production sites around the world and representatives in more than 70 countries, CIAT is a choice partner. Our air-handling division already has over 150,000 appliances in service in Europe. Backed up by this experience and our R&D potential, we offer solutions that satisfy the specific requirements of precision air-conditioning. > AT THE FOREFRONT of technology CIAT's European research centre, based at Culoz in France, spearheads its development and production efforts, creating the latest technologies in order to guarantee optimum heating and ventilation performance. Our test laboratory has gained world-wide recognition for its leading edge studies on fluids and energy optimisation. CIAT's production quality and its management of the logistics chain from supplier to final client are managed by supply chain software that optimises production time. For our clients, this industrial production also guarantees constant quality of both our products and the information provided. > A PARTNER in your precision Our know-how focuses specifically on satisfying the most stringent demands for temperature and humidity control. Our patented CIAT regulation PLCs, air-control systems that adapt air flows to thermal loads in premises, and high filtration devices provide the highest performances on the market.
handling > EXPERTISE in high security To protect your installations, we offer you the highest security thanks to full control from design to installation. CIAT's worldwide sales network distributes our products and ensures their maintenance, providing acknowledged reliability. Safety and troubleshooting devices are standard in our cabinets, in both the air-conditioning and cooling parts. The regulation automatons make it possible to switch from rotation, emergency and assistance modes between cabinets via a communication bus. > > REFERENCES in High - Tech Telecommunications SFR, France Télécom, LD Com, Belgacom, P&T Luxembourg Information Systems IBM, Michelin, Total Mobilcom, T System, Algeria Télécom, Télécom Nepal Ministry of Finance, Alcatel, Process engineering / Metrics / Storage of sensitive products Emin Leydier, Canal +, Stade de France, Musée du Petit Palais
>CIATRONIC System The range r Micro 2000 Performance and simplicity Flow rate: 1 000 to 2 000 m 3 /h Output: 5 to 10 kw > Temperature and humidity control > Chilled water or direct air expansion > More compact > Short delivery times > Optimisation of cost / performance ratio Company computer room
performanc ormance Magister 2 Expair Performance and efficiency Flow rate: 2 000 to 12 000 m 3 /h Output: 10 to 50 kw > Temperature and humidity control > Chilled water or direct air expansion > Numerous options > Competitiveness > Delivery within 3 weeks Computer room, telephone premises (unbundling, BBC) Electric premises Sensitive storage Exacting performance Flow rate: 3 000 to 22 000 m 3 /h Output: 10 to 90 kw > Temperature and humidity control > Chilled water or direct air expansion with air or water > Numerous adaptations, options and air flows > High energy efficiency > Low sound level > High efficiency filtration > Maximum security for your premises Data Center Computer rooms Electric premises Telephone exchanges Industrial applications Metrology
1 > Easy integration on site < >Micro 2000 Perf erformanc ormance e and simplicity Centrifugal fan with direct drive and manual variation for flow/pressure adaptation to air handling network Optimal compactness Communicative control between cabinets and possible connection to CTM (MODBUS / JBUS / LON) 3 > Easy installation and maintenance Connection: - hose kit for hydraulic connection - access to front panel - preloaded external units (direct expansion model) - easy access to connections Handling: aluminium frame and low weight, as compressors are in the external unit Easy extraction of filters 5 > Simplicity and efficiency Associated CONDENCIAT CL condensation units High quality design and finishing High energy output - SCROLL compressor and R410A fluid - speed variation card to adapt the fan to the condenser exchange requirement Installation: external unit capable of being offset by 50 metres from the internal unit > Chilled water models (EG) > Direct air expansion (DDA)
>Expair ormance e and efficiency Performanc 2 > Fast availability Essential components managed in stock: - panels - batteries / coils - condensation units - humidifiers - filters - electric batteries 4 > Competitiveness and performance Temperature and humidity control Rationalisation of components Double wall panel for better acoustic damping (fire resistance MO) Wide range of options Chilled water, direct expansion and air cooled condensation models > Chilled water models (EG) > Direct air expansion (DDA)
> Chilled water models (CW) > Direct air expansion (DXA) > Direct water expansion (DXW)
>Magister 2 Perf erformanc ormance e and exigencye 1 > Energy saving > SCROLL compression technology for R410A fluid for maximum energy efficiency (high EER) > Installation of the modular deep coil battery to minimise the system effect > Plug fan ventilators for better air handling efficiency linked with motor EC for optimal electric output > Automatic control: the automaton controls fan speed according to the load in the premises 2 > Easier handling and maintenance > Housing rigidity, rigid housing, front access > Direct coupling between the fan and motor > Filtration mounted on rails to facilitate handling > Communication of controls provides feedback and monitoring of the building 3 > Safety for your installations > Rotation / Backup / Auxiliary function between units > Communication with MODBUS / JBUS / LON protocol for real-time information > Double wall insulation with compressed 25 mm thick rock wool: fire resistance MO CIAT synergy: air or water cooled condenser manufactured by CIAT for perfect control of the entire unit 4 > Adaptation and precision Temperature and humidity control > Acoustic level reduced by - A double wall insulation - Air flow adjusted to cooling demand - Optimised aeraulics: reduced system effect air speed less than 2.5 m/s > Design and compact: fits perfectly in its environment > Continuous air filtration > Set point stability thanks to the use of control automatons (PI or PID) and regulation valve (progressive)
Everything you need to know about the >Technological choices / Design / Options APPLICATION Tertiary, computer room Data Center industry, telecom PERFORMANCE Model MICRO 2000 EXPAIR MAGISTER 2 Power range (kw) 5 to 10 10 to 45 10 to 90 Flow rate range (m 3 /h) 1000 to 2000 2000 to 12000 3000 to 22000 Number of models possible * chilled water 1 4 10 * direct expansion 3 8 22 FILTRATION Filtration efficiency G4 G4 / F7 G4 / F7 or G4 + F7 COOLING COIL Coil frame Galvanized steel Galvanized steel Galvanized steel or Stainless steel Condensate drain pan Galvanized steel Galvanized steel Aluminium / Stainless steel FAN HUMIDITY CONTROL (option) HEATING COIL (option) CONFIGURATION CONTROL CONSTRUCTION REFRIGERANT CIRCUIT OPTIONS Fan Direct drive electric centrifugal fan Direct drive electric plug fan Flow/pressure adjustment Humidifier Humidifier control Voltage variator Electrode Progressive Dehumidification Option Hot water coil Not available Option Electric battery regulation Stainless steel shielded element Electric battery regulation 1 stage 2 stages or TRIAC Speed variator (EC motor) or mechanical adjustment Assemblies available 1 or 3 1 / 3 / 4 or 5 1 / 3 or 5 Chilled water models (EG / CW) Direct air expansion model (DDA / DXA) Direct water expansion model (DXW) Control Water coil controlled by progressive 3-way valves Cabinet linked to a CIAT Condenciat type condensation unit (compressor outside cabinet) Not available CIAT μair connect Water coil controlled by progressive 2 or 3-way valves Not available CIAT μair connect CAREL pco3 Cabinet linked to a cooled condenser CIAT AIRIAL type air (compressor inside cabinet) Water-cooled condenser inside unit CIAT μair connect CAREL pco3 Protocole MODBUS / JBUS MODBUS / JBUS / LON MODBUS / JBUS / LON Rotation/backup/auxiliary YES YES YES Display text text text Filter clogging control standard standard standard Air flow control standard standard standard Water leak control option option option Low limit control on discharge Option option option Frame Panel Galvanised steel jacket + oven painting Double wall with compressed rock wool (fire resistance MO) Aluminium frame Double wall with compressed rock wool (fire resistance MO) Self-supporting or aluminium frame depending on size Double wall with compressed rock wool (fire resistance MO) Fluid compressor R410A R410A R410A Compressor technology SCROLL SCROLL SCROLL Adjustable support frame YES YES YES Discharge plenum YES YES YES Air intake motorised damper NO YES YES
CIATRONIC System Assembl sembly y / Air flow w direction Return air at top Micro 2000 Expair Magister 2 Air discharge at bottom Recycling at front Air discharge at top Micro 2000 Expair Magister 2 Air discharge at top Air discharge at top Expair Expair Magister 2 CW Return air at rear Return air at bottom Chilled water MICRO EXPAIR MAGISTER 2 Models EG 2000 EG 4000 EG 6000 EG 8000 EG 12000 CW12 CW18 CW24 CW30 CW35 CW45 CW61 CW70 CW80 CW90 Total output (kw) 8,4 18,1 26 36,2 54 12,1 18,4 24,2 30,5 34,7 44,6 60,9 69,5 80,3 87,4 Air flow (m 3 /h) 2000 4000 6000 8000 12000 3000 4500 6000 7500 8400 11000 15000 16800 19400 21500 Direct expansion MICRO EXPAIR Models DD 2000 CL20 DD 2000 CL28 DD 4000 CL 35 DD 4000 CL50 DD 6000 CL65 DD 6000 CL75 DD 8000 2XCL50 DD 8000 2XCL65 DD 12000 2XCL65 DD 12000 2XCL75 Total output (kw) 6,8 8,7 11,4 15,6 19,3 23,9 30,8 36,3 38,8 48,1 Air flow (m 3 /h) 1400 2200 3000 4000 5000 6000 7000 8000 10000 12000 Number circuits 1 1 1 1 1 1 2 2 2 2 Direct expansion MAGISTER 2 Models DX 12 DX 18 DX 23 DX29 DX 34 DX 35 DX 45 DX 46 DX 57 DX 67 DX 90 Total output (kw) 11,3 17,8 22,3 28,2 32,2 34,9 43,2 43,5 56 64 91 Air flow (m 3 /h) 3150 4700 6300 7850 8400 8400 11000 11000 15700 16800 23000 Number circuits 1 1 1 1 1 2 2 1 2 2 2
Climrack série CR > Optimise your data centres Very high capacity to size ratio: up to 18 kw per rack. Modular when adding new racks to a data centre. CLIMRACK is available fitted to 47U racks. > Increase your energy efficiency Hot air is conditioned at its source. The water temperatures are selected to ensure that no condensation forms, meaning that 100% of the heat energy produced can be dedicated to cooling. High water temperatures ensure that free cooling facilities are quickly cost effective. > Technical specifications Rack equipped with self-cont ontained cooling c system Return air temperature / humidity 33 C / 10g/kg dry air 33 C / 10g/kg dry air 37 C / 10g/kg dry air 37 C / 10g/kg dry air Water temperature conditions ( C) 13 / 18 14 / 19 13 / 18 14 / 19 Capacity (kw) 14 13 Water flow rate (m³/h) 2.4 2.24 3.09 2.93 > Safeguard your data centre Continuous fan operation ensures uniform temperatures in racks and in the room: no hot or cold spots. Use of halogen-free cables. Electronic fan speed control module. 18 17 Supply air temperature / humidity 22.5 C / 10g/kg dry air 23.2 C / 10g/kg dry air 23.5 C / 10g/kg dry air 24.2 C / 10g/kg dry air Pressure drop (mwc) 2.13 1.87 3.39 3.06 "CIAT also offers optimised energy solutions" Climrack Hydrociat water chiller ITEX plate heat exchanger Vextra dry cooler This document is non-contractual. As part of its policy of continual product improvement, CIAT reserves the right to make any technical modification it feels appropriate without prior notification. Head office & Factories Avenue Jean Falconnier - B.P. 14 01350 - Culoz - France Tel.: +33 (0)4 79 42 42 42 - Fax: +33 (0)4 79 42 42 10 e-mail: info@ciat.fr - www.ciat.com Compagnie Industrielle d Applications Thermiques - S.A. with a registered capital of 26 000 000 - R.C.S. Belley B 545 620 114