BROWNSVILLE VOLUNTEER FIRE DEPARTMENT

Similar documents
Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

STONY HILL RURAL FIRE DEPARTMENT OPERATING GUIDELINES

Cumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07

STANDARD OPERATING PROCEDURES RESPONDING TO EMERGENCIES DEPARTMENT RESPONSE PROCEDURES EFFECTIVE: AUGUST 2007

Outline. Standards of Coverage. ICS Features 2/12/2016 ICS

Structural Firefighting Policy

Travis County Emergency Services District #1 Standard Operating Guidelines

Field Operations Guide (FOG) Effective Date: December 1, 2003 Last Revision Date: November 1, 2015

SUBJECT FIRE OPERATIONS GUIDELINE (F.O.G.) #F510 Issued: 1/2014 Last Revision: 1/2014 Pages: 9 By Order Of: J.S. Thompson, Fire Chief

I. It shall be the responsibility of the department officers to implement this operating guideline.

Enactment Date: Rapid Intervention Team and RIT Officer

Truro Police Department. Fire Emergencies. Policy Number: OPS-9.02 Effective Date: June 1, 2000 REFERENCE:

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 High Rise On Scene Revised

MATRIX TO DETERMINE YOUR PRESENT POSITION IN MEETING N.F.P.A. 1720

THESE ARE THE OPERATING PROCEDURES OF THE BRENTWOOD FIRE DEPARTMENT

INTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

SPEARFISH FIRE DEPARTMENT POLICIES AND PROCEDURES

ADVANCED EXTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

Elko County Human Resources Employment Opportunity Announcement

Communications Committee SUBJECT: Dispatching System SUPERSEDES:

9S / 9E Inspection Worksheets. The fire department should complete the following sheets prior to inspection date

217 Commercial Avenue Aspinwall, PA Station 1: (412) Fax: (412)

San Ramon Valley Fire Protection District GREEN SHEET

FIREFIGHTER II MANIPULATIVE SKILL OBJECTIVES

Essentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)

Radio Communications Guideline

Guidelines for Media at Emergency Incidents

COUNTY OF BERGEN DEPARTMENT OF PUBLIC SAFETY LAW AND PUBLIC SAFETY INSTITUTE POLICE, FIRE & EMS ACADEMIES 281 Campgaw Road Mahwah, N.J.

Rapid Intervention Team

Operations Manual. Whitehall Volunteer Fire Company Inc.

Operational Guideline

VOLUSIA COUNTY FIRE CHIEFS ASSOCIATION MODEL OPERATING GUIDELINE

University of Maryland FIRE EVACUATION PLAN NATIONAL DENTAL MUSEUM POLICE FIRE MEDICAL EMERGENCY Anyone discovering excessive heat,

CHAPTER 05 - OFFICE OF STATE FIRE MARSHAL SUBCHAPTER 05A - FIRE AND RESCUE SECTION.0900 PUBLIC PROTECTION CLASSIFICATIONS FOR FIRE DISTRICTS

SOUTHERN AFRICAN EMERGENCY SERVICES INSTITUTE NPC Registration No. 2014/162285/08. Fire Fighter 1 - NFPA 1001, 2008

AMADOR FIRE PROTECTION DISTRICT

Mulch fires, trash can fires, or other fire outside a building should be reported by the following methods:

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

Additional Materials: Instructor s PowerPoint, Question Files

Emergency Planning and Preparedness

AIRPORT FIRE FIGHTER ID#: STANDARD:

BYLAW 5542 *******************************************************************************

HOLLY HILL FIRE DEPARTMENT

NATIONAL FIRE PROTECTION ASSOCIATION Fourth Survey of the Needs of the U. S. Fire Service

FIREFIGHTER II: FIRE DEPARTMENT COMMUNICATIONS COMMUNICATIONS: SKILL SHEET #2 Define and Demonstrate Fire Department Radio Procedure

DOD FIRE SERVICE CERTIFICATION SYSTEM LESSON PLAN 7. Fire Alarm and Communication

FEMS Board Executive Committee Agenda 3/2/2015

Travis County Emergency Services District #1 Standard Operating Guidelines

ATTIC FIRES. Part 3 HEAVY SMOKE SHOWING

6. INCOMING EMERGENCY CALLS, ALARMS AND INCIDENT DISPATCH

3330 N Clayton. C - Side Date: 11/18/2017 Time: 21:48 Incident Number: Address: 3330 N Clayton

Westbury Fire Department: Hose Company 2 Drill 7/24/14 Thinking Beyond the Obvious or the Norm

TACTICAL GUIDELINES. To provide guidelines to aid the decision making process for personnel during emergency/nonemergency

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

To provide guidelines to aid the decision making process for personnel during emergency/non-emergency incidents.

1.7 SECTORS, GROUPS AND DIVISIONS

CHAPTER 1 ADMINISTRATION AND ORGANIZATION

Career Fire Fighter Dies From Injuries Sustained In Fall From Apparatus - Massachusetts

Assignment Sheet Apply the NIMS-ICS Model to an Emergency Scene

Centers for Regional Excellence. Downriver Fire Authority. Organization Committee Objective. Operations Committee Report 2007

AMADOR FIRE PROTECTION DISTRICT

OPERATIONAL GUIDELINES FIRE/RESCUE MANUAL

EASTERN ARIZONA COLLEGE Fire Department Operations II

FIREFIGHTER II: FIRE DEPARTMENT COMMUNICATIONS COMMUNICATIONS: SKILL SHEET #2 Define and Demonstrate Fire Department Radio Procedure

TITLE: Offensive and Defensive Operations

FREDERICK COUNTY / WINCHESTER FIRE AND RESCUE DEPARTMENTS BASIC FIRE ACADEMY #15 CERTIFICATION COURSE SEPTEMBER 2015 APRIL 2016

Township Of Jackson, Fire District 3, Station 55 Standard Operating Guidelines FIRE GROUND STRATEGY

SAGINAW FIRE DEPARTMENT SAFER

Austin Independent School District Police Department Policy and Procedure Manual

!!!!! Program Checklist

Contra Costa County Fire District Station # 69. Battalion 7. November Your station responded to 129 Emergency Calls. Response breakdown

University of Maryland FIRE EVACUATION PLAN Columbus Center POLICE FIRE MEDICAL EMERGENCY - 911

GLOSSARY OF FIRE PROTECTION TERMS

Dutchess Community College. Emergency Action Plan. Conklin Hall College Residence

Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition.

KAMLOOPS FIRE RESCUE OPERATIONAL GUIDELINE. Eff. October 1 st, To ensure understanding of scene locations and designations

Development and Use of Interdivisional Box Alarm Cards

BUILDING SECURITY and EVACUATION RELATED POLICIES: REVIEWED: AS NEEDED

RAMBLER PARK FIRE SAFETY INFORMATION

Fire Department Orientation / Organization

Whitestown Fire Department Standard Operating Procedure

Death in the line of duty

I. INTRODUCTION. A. Purpose: To provide procedures and guidelines for personnel responding to and operating at working structure fire incidents.

Pro Board Assessment Methodology Matrices for NFPA 1001

Death in the line of duty

Required Materials For complete material(s) information, refer to

Emergency Preparedness Guide

VISITOR SAFETY AND ORIENTATION BOOKLET

FIRE PROTECTION BUREAU ACCREDITATION AND CERTIFICATION PO Box Olympia WA (360) FAX: (360) AIRPORT FIREFIGHTER

DUNCAN STUDENT CENTER. Emergency Action Plan

Fire ground electrocution

FIREFIGHTER 1 COMPETENCY EVALUATION

Service Business Plan

GUIDELINES FOR DEVELOPMENT OF A FIRE DEPARTMENT OPERATIONAL MANUAL REVISED JUNE 2009

WELCOME TO THE YUKON FIRE SERVICE

Business Emergency Plan

Technician I Kyle Wilson Line of Duty Death April 16, Marsh Overlook Structure Fire Investigative Report

Where There's Smoke. Warrant Article 4 - New Fire Station

Fire Evacuation Plan Health Sciences & Human Services Library. UMB POLICE or

2012 SunTrust Center ERT Annual Review. 919 East Main St. Richmond, VA

Transcription:

BROWNSVILLE VOLUNTEER FIRE DEPARTMENT USTANDARD OPERATING GUIDELINES U TABLE OF CONTENTS 100 - PROTECTIVE CLOTHING AND PERSONAL SAFETY 200 - DISPATCH 300 - DRIVER OPERATIONS 400 - APPARATUS RESPONSE/ASSIGNMENT PROCEDURES 500 - COMMUNICATIONS 600 - WATER SUPPLY 700 - INCIDENT COMMAND 800 - FIREGROUND PROCEDURE 900 - MUTUAL AID 1000 - SEARCH AND RESCUE 1100 - SEVERE WEATHER 1200 EMERGENCY MEDICAL SERVICE 1300 VEHICLE EXTRICATION The policy of The Brownsville Volunteer Fire Department is to apply the Provisions of these standard operating guidelines to all members without regard to sex, race, color, religious creed or national origin. The provisions of these standard operating guidelines will be interpreted so that all masculine terms shall include all feminine terms and all feminine terms shall include all of the masculine terms. 1 4/14/2014

100 PROTECTIVE CLOTHING AND PERSONAL SAFETY 101 - Anyone on the fire ground must be in full protective clothing: bunker pants, coat, boots, helmet, nomex hood, and leather gloves. On a wildland fires, nomex pants, shirt or (coveralls), hard hat, leather gloves, and leather boots shall be worn. Web gear and fire shelter will be available at all times. Leather Boots are the responsibility of the firefighter. 102 - All personnel on the fire scene will be issued complete bunker and wildland gear and will be responsible to have same at the scene. 103 - No firefighter shall enter a hazardous environment without full protective clothing and selfcontained breathing apparatus. This includes ventilation, attack, rescue and overhaul. 104 - It is the policy of the Brownsville Volunteer Fire Department that no firefighter shall be permitted to operate any department vehicle or to actively participate at an incident while under the influence of any intoxicant. 105 - No firefighter shall enter a hazardous environment without knowledge of hazardous materials within. 106 - Non-certified firefighters will not be involved on interior operations unless ordered by command and will be accompanied by certified firefighters. 200 DISPATCH 201 - All fires shall constitute a full alarm. 202 - Alarm procedure: 1. Deadwood fire control will tone pagers. 2. Incident information will be available at the station. 3. Each unit will advise Deadwood fire control they are enroute (10-8) 4. No self-dispatching will be permitted. 203 - When the first unit arrives on scene give Deadwood fire control a complete size up and request additional resources as needed. 204 - All fire and emergency calls will be paged by Deadwood Fire Control or by an officer from the Brownsville Fire Station. 300 DRIVER OPERATIONS PERSONAL VEHICLES (POV) 301 When responding to an alarm all traffic laws will be obeyed. 2 4/14/2014

302 - When responding to an alarm private vehicle headlights should be lighted and all occupants of the vehicle should wear seat belts. 303 - When responding to an alarm, firefighters in a private vehicle shall not pass other firefighter vehicles or fire apparatus except with discretion or if flagged by lead vehicle operator. 304 - Firefighters arriving at an incident in private vehicles, unless involved in the initial attack, should report to incident command. 305 - Private vehicles should not use four way flashers when responding to an alarm. Their use makes it impossible to signal a turn. 306 - Private vehicles must be parked clear of the incident; i.e. one block away, side streets, etc. UFIRE APPARATUS 319 When responding to an alarm all traffic laws will be obeyed. 320 - It is the policy of the Brownsville volunteer fire department that emergency personnel only shall ride in fire apparatus when responding to an alarm. Children and spouses shall not ride in the apparatus during an alarm except in extreme circumstances. 321 - Each fire apparatus should have a minimum of 2 personal before responding to an incident unless command otherwise instructs. 322 - Full personnel protective clothing will accompany personnel when taking apparatus out of station for non-emergency purposes. 323 - Personnel shall have proper DEPARTMENT training and certification prior to operating fire apparatus. 324 - Apparatus responding to an alarm must sound all audible warning signals or display warning lights. 325 - Apparatus responding to an alarm shall not pass other responding apparatus except under unusual circumstances, and then only with the permission of the lead apparatus. 326 - Passengers shall operate radios, lights, sirens and air horns. 327 - Everyone helps to get the apparatus in a ready condition after an incident. 328 - Identified fire department members appointed by the chief will be responsible for the readiness of the fire apparatus. 3 4/14/2014

401 - USTRUCTURE FIRES U 400 APPARATUS RESPONSE / ASSIGNMENT PROCEDURES A. All trucks will respond. B: Position truck according to preplan or as follows when conditions permit. ENGINE 3: To accessible location TENDER 1: Dump port-a-tanks and start water shuttle operation. 402 - UWILDLAND FIRES U A. Trucks responding will be identified by the IC. 403 - UVEHICLE FIRESU A. Trucks responding will be identified by the IC. B. Trucks should remain 100 feet from vehicle. 404 - UKNOWN HAZARDOUS MATERIALS A. Truck Responding Will be identified by the IC. All other trucks are to be Staged according to the IC. B. No personal vehicles are to be at the scene. Personal shall stand by at the Fire hall for assignments. 500 COMMUNICATIONS 501 - All radios operate on Lawrence County Fire until given the command to do otherwise. 502 - Command will designate a simplex tactical channel as soon as possible to clear the incident from the Lawrence County Fire channel. 503 - Command will be established and incident command will communicate with Deadwood fire control. 504 - Plain English will be used. 505 - When making call, announce unit or person being called first and caller second and on what channel being used. 506 - All orders given by command will be repeated on radio by receiver. 507 - Each attack, rescue and ventilation team will have a radio. 4 4/14/2014

508 - Radios will be used with discretion. Names of victims will not be transmitted. 509 Call for Emergency Radio Traffic ALL UNNESSARY RADIO TRAFFIC STOP. This would include a Mayday. 600 WATER SUPPLY 601 - Out of town fires, use water shuttling from water points to fire. 602 - Use of mutual aid will be determined by command. 700 INCIDENT COMMAND 701 - Chhain of CommandU Chief Asst. chief Captains Firefighters Trainee firefighters Support Personnel 702 - Senior person on first arriving truck will be the incident commander of such incident until relieved by a superior officer. USOMEONE MUST BE IN CHARGE 703 - ICS will be used and incident commander will be called command. 704 - Command will transmit an initial report upon arrival at the scene. This report should include building description, condition (smoke, flame, nothing showing), confirmed life hazards (person trapped), and command location. 705 - Command is responsible for the following tasks: 1. Assume an effective command position. 2. Transmit an initial radio report. 3. Make a complete initial size up of the situation including a 360 walk around. 4. Implement a plan of attack and assign specific resources and tasks. 706 - IC will call the State Fire Marshall for any structure fire, or if deemed necessary. 707 - Safety officer or anyone qualified on the fire ground will have the power to stop all unsafe operations. 707 - Anyone may call the Mayday in the event of immediate danger to anyone on the scene. 5 4/14/2014

800 FIRE GROUND PROCEDURE 801 - Personnel responding in trucks to fire scene shall stay with that truck until relieved by command. 802 - Driver shall be responsible for pumping apparatus until relieved. 803 - An initial attack requires a minimum of one 1 1/2 line with a pump pressure of 125 psi. 804 - Attack lines up to 1 1/2 require a minimum of two firefighters on each line, and lines larger than 1 1/2 require a minimum of three firefighters on each line. 805 - All nozzles on all lines must be set at maximum gallonage following an incident. Nozzlemen may adjust gallonage settings as the incident dictates. 806 - Hose is to be laid as to best maintain a clear roadway for additional apparatus. 807 - Interior search pattern shall be to the right and shall proceed in a counter clockwise manner. Team leaders must report to the incident commander when the search is complete. 808 - If ladders are required, buildings must be laddered in two places for a means of entrance and exit by attack and rescue crews. 809 - Fireground personnel will be warned of a possible collapse of structure by one long air horn blast of at least 15 seconds by all on-scene apparatus and supplemented by radio from command. Personal are to leave the danger area immediately, abandoning equipment if necessary. Personnel are to report to a safety officer. Safety officers must ensure that all personnel have exited to safety and report to command. 810 - No firefighter shall enter a structure for firefighting, salvage or overhaul operations except under the control of a safety officer. Firefighters should, if possible, use the same exit as used for entry. If this is not possible, firefighters should report promptly upon exiting to the safety officer. 900 MUTUAL AID 901 - Men and equipment shall be dispatched by chief or senior officer. 902 - Chief or senior officer will determine what trucks can respond. 903 - Names of men responding will be noted by officer in charge at fire station. 904 - Crews responding to a mutual aid call shall report to officer in charge of incident. 905 - Members shall work in pairs at the fire scene if possible. 906 - Members shall take orders from command. 6 4/14/2014

1000 SEARCH AND RESCUE 1001 - For searches - Meet at fire station to organize. Incident command will give assignments. 1100 SEVERE WEATHER 1101 - Spotters will meet at fire station to organize. Incident command will give assignments. 1200 Emergency Medical Service 1201 - Responders should complete a First Responder class for Emergency Medical Service. 1202 - Body Substance Isolation (BSI) equipment must be worn during any EMS call where there is a risk of exposure from unknown body substances. 1203 - Any exposure must be reported and preventative measures taken immediately to reduce the risk of contamination to the responder. 1300 Vehicle Extrication 1301 - Scene safety shall be the priority for responding personal. 1302 - Full personal protective equipment will be worn during emergency operations. 1303 - Responders should attend extrication training and be familiar with the rescue equipment. 7 4/14/2014