VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

Similar documents
VENTILATION FAN WITH LIGHT AND HEATER

VENTILATION FAN / LED LIGHT

HUMIDITY SENSING BATH FAN

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

VENTILATION FAN WITH BLUETOOTH SPEAKER

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Installation Instructions Exhaust Fan With Light

READ AND SAVE THESE INSTRUCTIONS

e Heater/Exhaust Fan/Light User s Guide

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

INSTALLATION MANUAL AND USER GUIDE

breeze easytm model # F100-1W

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

INSTALLATION MANUAL AND USER GUIDE

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Bathroom Exhaust Fan

Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

Please Read and Save These Instructions Safety Information

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

READ AND SAVE THESE INSTRUCTIONS

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

Easy installation in both new construction and retrofit

Easy installation in both new construction and retrofit

Bathroom Exhaust Fan/Fluorescent Light Combination

Bathroom Exhaust Fan/Fluorescent Light Combination

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

FLCH4R Garage and Utility Electric Heater

Integrated Ventilation System

ELECTRIC STOVE HEATER Models: FS2213B

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

Insulated Ventilators. Operating Instructions & Parts Manual

ELECTRIC FLAT PANEL FIREPLACE HEATER

OWNER S MANUAL. Wall Hanging Mode. Pedestal Mode ELECTRIC FLAT PANEL FIREPLACE HEATER. Model Number: EFW-XB60B WARNING CAUTION

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

Installation & Maintenance Instructions

Humidity and Thermostat control box for Attic Fan

Installation Instructions Preference Wall Mount Range Hood

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

PLEASE READ AND SAVE THESE INSTRUCTIONS

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

Wall Hanging Mode. Pedestal Mode

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

User s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

CONTENTS WIRING DIAGRAM

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

SF180 Installation Instructions

24 & 30 Quiet Design Oscillating Wall Mount Fan

Installation Instructions Remote Blowers

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

READ AND SAVE THESE INSTRUCTIONS COOKING ONLY.! WARNING

IMPORTANT INSTRUCTIONS READ & SAVE

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

RP, GP, XP Pro Series Installation Instructions

60In. Ceiling Fan. Owner s Manual

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

INSTALLATION INSTRUCTIONS FOR WHOLE HOUSE FANS

READ AND SAVE THESE INSTRUCTIONS

OWNER S MANUAL ELECTRIC FLAT PANEL FIREPLACE. AC V 60Hz. Model# : /60 - Built-in & Wall Mounted Electric Fireplace WARNING CAUTION

WS-5530SS WS-5536SS WS-5542SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

COM-PAK COM-PAK TWIN. Com-Pak/Com-Pak Twin Heater. Owner s Guide. tested to UL standards PERFECTLY SIMPLE WARMTH FOR ANY ROOM

User s Manual WS-68N30SS WS-68N36SS WS-68N42SS

IMPORTANT INSTRUCTIONS

IMPORTANT INSTRUCTIONS READ & SAVE

Easy installation. T080LP ENERGY STAR Lo Profile Ventilation Fan INSTALLATION GUIDE

Turin LED Ceiling Fan

User s Manual WS-5830SS WS-5836SS WS-5842SS

IMPORTANT INSTRUCTIONS READ & SAVE

MaxLite LED Vapor Tight Linear Fixture

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

Please Read and Save These Instructions.

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

CVS Model Inline Multi-Port Ventilators


Flat Wall Mounted / Free stand Electric Fireplace. Model Numbers: S OWNER S MANUAL. Wall Hanging Mode. Freestanding Mode AC 120V / 60HZ 1500W

READ AND SAVE THESE INSTRUCTIONS

IMPORTANT INSTRUCTIONS READ & SAVE

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

Transcription:

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED TABLE OF CONTENTS Package Contents Important Instructions Preparation Assembly Instructions Wiring Instructions Operating Instructions Care and Maintenance Dimensions Product Specification Troubleshooting Warranty 2 3 4 5 9 9 10 11 11 12 12 READ AND SAVE THESE INSTRUCTIONS Address: 46101 Fremont Boulevard, Fremont, CA 94538 US Toll Free Number: 1-888-979-9889 www.deltabreez.com

PACKAGE CONTENTS PART DESCRIPTION QTY 1 1 Fan Body 1 2 Duct Connector 1 3 Grille 1 2 HARDWARE CONTENTS (Images are not shown in actual scale) A 4 Suspension Bracket 3 B 8 Wood Screw (Ø 4 x 25 ) C 1 Short Machine Screw ( M4 x 5 ) 2

IMPORTANT INSTRUCTIONS When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: Read all instructions before installing or using this heater. Extreme caution is necessary when heater fan is used by or near unattended children, and / or persons with disabilities or limitations. Do not operate heater if it malfunctions. Disconnect power at service panel and have heater inspected by reputable electrician before reusing. Do not use outdoors. To disconnect heater, turn controls to OFF switch. Then, turn off the power to the heater circuit at the main disconnect panel. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock of fire, or damage the heater. To prevent a possible fire, do not block air intakes or exhaust in any manner. A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable vapors or liquids are used or stored. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons. SAVE THESE INSTRUCTIONS Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product. Follow all local safety and electrical codes as well as NEC (National Electrical Code) and OSHA (Occupational Safety and Health Act). This unit must be properly grounded. Always disconnect the power supply prior to servicing the fan, motor or junction box. Do not bend or kink the power wires. Protect from sharp edges, oil, grease, hot surfaces, chemicals or other objects. Do not install over a tub or mount in a shower stall enclosure. Do not use to exhaust hazardous or explosive vapors. Do not install in a cooking area. Do not install this fan vertically in a wall. Use this unit in the manner intended by the manufacturer. If you have any questions, please call the manufacturer. Installation work must be carried out by a qualified person(s) in accordance with all local and safety codes including the rules for fire-rated construction. For use in non-fire rated installations only. Sufficient air supply is required for proper combustion and the exhaustion of gases through the chimney (flue) of fuel burning equipment to prevent back-drafting. See the standards of NFPA (National Fire Protection Association) and ASHRAE (American Society for Heating Refrigeration and Air Conditioning Engineers) and the local building code authorities. Exercise care to not damage existing wiring when cutting or drilling into walls or ceilings. Fans should always be vented to the exterior and in compliance with local codes. Do not use this fan with any solid state control device such as a dimmer switch. Solid-state controls may cause harmonic distortion, which can cause a motor humming noise. Prior to service or cleaning this unit, shut off power supply at the panel and lock to prevent the power from being turned on. If the panel cannot be locked, clearly mark the panel with a warning tag to prevent the power from being turned on. Do not install in a ceiling with insulation greater than R40. (This is required for installations in Canada only.) Duct work should be installed in a straight line with minimal bends. Duct work size must be a minimum of the discharge and should not be reduced. Reducing the duct size can increase fan noise. This ventilating bath fan is intended for residential use only in 1-2 family dwellings. Never place a switch where it can be reached from a tub or shower. Make sure that the electric service supply voltage is AC 120 V, 60 Hz. Always disconnect the power source before working on or near the unit. This unit is designed and tested to be a supplemental heater for use with a timer or a switch. It is not intended to be used as a primary source of heat, or controlled by a thermostat. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc., off power unit. Provide a separate 20 AMP circuit. This product is designed for ceiling installation only. Do not mount this product in a wall. Install in ceiling only, at least 6 in. from any wall. For greatest efficiency, adjust heater grille directly toward tub or shower area. Avoid directing toward walls or windows. Do not install less than 8 ft. (2.4 m) from the floor. 3

PREPARATION Tools Required for Assembly (not included): Hammer, Flathead Screwdriver, Wire Nuts, Nails, Duct Tape, Phillips Head Screwdriver, Utility Knife Helpful Tools (not included): Electric Drill, Drill Bits WARNING: Turn off electricity at breaker box before beginning installation. Carefully remove unit from carton. Before installation, provide inspection and future maintenance access at a location that will not interfere with installation work. Check area above installation location to be sure that wiring can run to the planned location and that duct work can be run. Make sure the area is sufficient for proper ventilation. You may need the help of a second person to install this fan: one person on the attic side and one on the room side. Note: Installations may vary depending on how the previous bath fan was installed. Supplies necessary for the installation of your bath fan are not all included. However, most are available at your local home improvement or hardware store. Proper insulation around the fan to minimize building heat loss and gain. Locate unit away from heating or cooling sources. The fan will operate most efficiently when located where the shortest possible duct run and minimum number of elbows will be needed. Use a roof cap or wall cap that has a built-in damper to reduce backdrafts. External timer/dimmer switch can be used please contact Delta Breez customer service and consult with a licensed electrician for compatibility. WARNING: Remove ceiling section using dimensions provided below. Be careful to cut hole exactly. If hole is too big, the fan grille will not hide it. DIMENSION REQUIREMENTS Housing Dimension (L) Housing Dimension (W) Housing Dimension (H) 15 1/2 in. 9 1/2 in. 7 1/2 in. 4

ASSEMBLY INSTRUCTIONS Unpacking Carefully remove unit from carton. Remove the foam in the housing. Refer to the Package Contents list on page 2 to verify that all parts are present. Installing the unit Installing the fan body in an existing building requires an accessible area (attic or crawl space) above the planned installation location and existing duct and wiring. CAUTION: Check area above installation location to ensure that: Duct work can be run and the area is sufficient for proper ventilation. Wiring can be run to the planned location. No wiring or other obstructions can interfere with installation. WARNING: To reduce the risk of fire, do not store or use gasoine or other flammable vapors and liquids in the vicinity of the heater BEFORE INSTALLATION 1. Attach the duct connector from the housing inside, and secure using the short machine screw. Hardware C Short Machine Screw Insert tab into slot in housing C Short Machine Screw 2 1 5

ASSEMBLY INSTRUCTIONS INSTALLATION 1. Mounting the fan body between the joists 1-1 a. Insert suspension brackets A to the duct side and back of the fan body 1, depending on the distance between the joists. b. Insert the fan body 1 between joists. Make sure the fan body is level and perpendicular with the joist, and flush with ceiling surface. c. Allow for thickness of the ceiling board used in your application. Fan body 1 should be flush with ceiling board. d. Secure the suspension brackets to joists with the wood screws B. e. Remove tap before connecting the duct as shown in Figure 1-2. A A Hardware A Suspensin Bracket B 1-2 B Wood Screw 6

ASSEMBLY INSTRUCTIONS 2. Connecting the duct 2-1 CAUTION: All ducting must comply with local and national building codes. a. Insert the duct into the duct connector and tape all duct work connections to make them secure and air tight. b. Do not install the unit where ducts are configured as shown in Figure 2-2. Install the duct with a gradient of 1-2 to the outside. 2-2 Minimum 18 in. 3. Remove the fan junction box cover a. Using wire nuts (not supplied), connect house wires to fan wires b as shown in the wiring diagram on page 9. Wire connections are as follows: black to live switch wire, white to neutral, green to ground. Reattach fan junction box cover c. 3-1 7

ASSEMBLY INSTRUCTIONS 4. Completing the Installation 4-1 a. Check the plug from the fan into the receptacle marked Vent. Check the plug from the heating unit into the receptacle marked Heat. VENT LIGHT HEAT b. Plug the Light Connector into the receptacle marked Light. 4-2 3. Attach grille 2 by pinching mounting springs a and insert into narrow rectangular slots in fan body. 4-1 Slots Spring a 8

WIRING INSTRUCTIONS CAUTION: Make sure power is switched off at service panel before starting installation. All electrical connections must be made in accordance with local codes, ordinances, or national electrical code. If you are unfamiliar with methods of installing electrical wiring, secure the services of a qualified electrician. WARNING: This unit must be wired on a separate 20 amp circuit. If your house wires do not match these colors, you must determine what each house wire represents before connecting and you may need to consult an electrical contractor to determine this safely. 1. Follow all local electrical and safety codes. 2. Never place a switch where it can be reached from a tub shower. 3. Using wire nuts (not included), connect house power wires to fan wires. 4. 12 AWG is the smallest conductor that may be used for branch-circuit wiring. Each power wire (light, fan, heater) must have its own switch to operate independently. 5. For supply connections, use wire rated for at least 90ºC. See wiring diagram for wire size. OPERATING INSTRUCTIONS WARNING: This unit must be properly installed before it is used. Follow instructions for cleaning, user-maintenance and operations recommended by the manufacturer, such as lubrication or non lubrication. Any other servicing should be performed by an authorized service representative. 1. Turn on the light switch to turn on the LED light. 2. Turn on the vent. switch to operate the fan mode. 3. Turn on the heat switch to operate the heater mode. 4. Adjust heater grille blade to provide heat in the desired direction. 40 9

CARE AND MAINTENANCE See safety information before proceeding. Routine maintenance should be done at least once a year. Never use solvents, thinner or harsh chemicals when cleaning the fan. Do not allow water to enter the motor, heater and LED module. Do not immerse metal parts in water. 1 Do not immerse resin parts in water over 140º Fahrenheit. Turn off power source. Review all safety precautions. Spring Slots 1. Squeeze springs and pull down. a 2. Remove grille 2. 2 3. Remove dust and dirt from fan body 1 and filter 3 with a vacuum cleaner. 3 3 Vacuum cleaner 10

DIMENSIONS 4" 9 1 2 " 12" 9 1 3 " 2 1 2 " 18 7 8 " 1 1 5 " 7 1 2 " 15 1 4 " 4" Unit: Inches PRODUCT SPECIFICATIONS Model No. Air flow @ 0.1 in. WG Noise Voltage Hertz Power Consumption Duct Diameter Weight Main Light Output TYPE IC INHERENTLY PROTECTED. THERMALLY PROTECTED L. SPECIFICATIONS RAD110LED 110 CFM 0.7 Sones 120V 60Hz 1650W 4 in. 14.8 lbs. 850 Lumens 11

TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION The fan is not turning on The fan seems louder than it should The fan is not clearing the room The light is not turning on The heater is not heating than it should 1. Power off 2. Faulty switch 3. Faulty wire connection 1. CFM is too great 2. Damper not working properly or damaged 3. Bend in duct too close to fan discharge 4. Fan discharge reduced to fit smaller duct 5. Fan body not securely attached 1. Insufficient intake airfow within room 2. Insufficient CFM 1. Power off 2. Faulty switch 3. Faulty wire connection 1. Faulty switch 2. Faulty wire connection 3. Filter is not clean 1. Make sure power supply is on. 2. Test or replace switch. 3. Check wire in switch box. 1. Be sure CFM rating on the fan matches the size of your room. 2. Be sure damper is opening and closing properly. If the damper has become damaged, please call Customer Service. 3. Be sure you do not have any sharp bends in duct closer than 18 in. to the fan discharge. 4. Use recommended size ducting to reduce fan noise. 5. Be sure the fan is securely attached to your ceiling joists. 1. Be sure a door or window is slightly ajar or opened to allow airflow. The fan is not able to draw air out of the room without enough airflow to draw in from. 2. Be sure the CFM rating on the fan matches the requirements for your room size. 1. Make sure power supply is on. 2. Test or replace switch. 3. Check wire in switch box. 1. Test or replace switch. 2. Check wire in switch box. 3. Remove dust from filter. WARRANTY DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY Delta Electronics Inc. ( Delta Electronics ) warrants to the original consumer purchaser in the USA that the Breez ventilation fan products will be free from defects in material or workmanship. This warranty is limited to three (3) years from the original date of purchase. Limitations and Exclusions 1. During the warranty period, a replacement for any defective product will be supplied free of charge for installation by the consumer. The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting, repair, removal, and installation service. 2. All returns of defective parts or products must include the product model number, and must be made through an authorized Delta Electronics distributor. Authorized returns must be shipped prepaid. Repaired or replacement products will be shipped by Delta Electronics F.O.B. shipping point. 3. Delta Electronics shall not be liable for any indirect, incidental, consequential, punitive, or special damages arising out of or in connection with products use or performance, regardless of the form of action whether in contract, tort (including negligence), strict product liability or otherwise. 4. This warranty does not extend to fluorescent lamp starters and tubes. 5. The warranty does not cover if user does not comply with manufacturer s installation manual. 6. To qualify for warranty service, you must notify Delta Electronics at the address or telephone number below. 7. Delta Electronics shall have no liability to the original owner-user with respect to any defect caused by abuse, misuse, neglect, improper transportation or storage, improper testing, improper installation, improper operation, improper use, improper maintenance, improper repair, improper alteration, improper modification, tempering or accident of products or parts thereof, or unusual deterioration or degradation of products or parts thereof due to a physical environment beyond the requirements of products' specifications. Address: 46101 Fremont Boulevard, Fremont, CA 94538 US Toll Free Number: 1-888-979-9889 www.deltabreez.com 5016234000 12