operation manual SAUNA-VII (07/05) page 1 of 14 SAUNA- Plus VII

Similar documents
Action shower Fog Rain

Operation manual SOL-TEC - SL

Operation manual Action Shower Tropica

WDT Service Instruction GRANUDOS 45/100 (V62PB-04-06) page 1 of 1. Series No...Customer...Date of delivery. Operating instructions GRANUDOS 45/100-PB

HX-30/40 and HX-30/40 S Glass and Dishwashers

Owner s Manual RD432-0 Chemical Controller

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

WHY CHOOSE AN EXTREME DUTY MULTI VAC INDUSTRIAL VACUUM SYSTEM?

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

WDT Operating Instruction GRANUDOS 45/100-S41 (11/05) page 1 of 1. Series No...Customer...Date of delivery. Operating instructions GRANUDOS 45/100-S4

OPERATION AND INSTRUCTION MANUAL NORCLEAN POWERED EDDY CURRENT VACUUM RECOVERY SYSTEM WITH WATER TRAP OPTION

RA 701 B Batterie assembling. As at: 01/15/10 Time:21:19

Operating Instructions SUPERSTAR E-6000 / F2 for 1 1/2, 2 and VAC

AUC Cell Washer. User Manual

FAULT FINDING. Water Gas Cassette Toilet FAULT FINDING

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Next Generation Corona Discharge Installation & Operation Manual

Glass and Dishwashers AMX / AUX Series

Digital 7 Square Plate Magnetic Stirrer

FD 430 Envelope Sealer

Hand pump JP-02. Hand pump JP-02 for acids, alkalies and water-based chemicals. depending on lever position. The telescopic suction tube is adjustable

M790 ph/orp Controller. Owner s Manual

SG 4/4 Service Manual

3. Thermal switch (70 o C thermostat) with a 3 m connection cable

DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS

INDEX I.- FINAL TEST FOR PRODUCT SAFETY 3 II.- REPLACEMENT PROCEDURES 3 III.- TROUBLE SHOOTING CHART 5 IV.- WIRING DIAGRAM 6 V.- ELECTRICAL RATING 6

Slim Line Service Manual

OWNERS' GUIDE PRECISION WATER SYSTEMS WATER DISTILLER. Water Systems FOR MODELS: PWS MANUFACTURED BY:

CONTROLS INSTRUCTIONS MANUAL ENGLISH

HD Kompakt Service Manual

CAUTION UM120W (RIGHT TANK) FOR WATER BORNE PAINTS ONLY UM120W (RIGHT TANK) SECTION IS NOT DESIGNED FOR USE WITH SOLVENT BASED PAINT

INSTRUCTIONS MANUAL CONTROLS. Description Power Rating Remarks Steamer. Description Power Rating Remarks Control

VIKING RANGE CORPORATION, P.O. DRAWER 956, GREENWOOD, MS USA

2 INSTALLATION OPERATION TECHNICAL SPECIFICATIONS COMPONENTS FUNCTIONS REPAIR Series TS14/TDS14/PL138

NEPTUN I Sole cleaning unit Art.-No.:

Spare parts list ( ) SGV 6/5

D3000. Installation & Setup Guide

Glass and Dishwashers AMX / AUX Series

DEMA 830 Laundry Master TM Installation Instructions

VC-1, VC-1-SL, VC-2-L, VC-2-SL

B 80 W Bp. Register and win! /13

AEM EASY DRUM M A N U A L

Micro/Ultra Filtration System StamoClean CAT 430

User Manual. MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S

Vacmobile 20/2. Instruction manual OPERATION & SERVICE

OPERATING INSTRUCTIONS. Cafitesse

INSTALLATION & SERVICE BOOKLET. Juice Machine - Postmix JM 6 JM 7

Propane Heater REMKO PGM 30 REMKO PGM 60

Installation and Setup

SERVICE MANUAL MULTI DECK 60 HOT MERCHANDISER MULTI DECK 100 HOT MERCHANDISER MULTI DECK 120 HOT MERCHANDISER CLASSIC DECK HOT MERCHANDISER

Spare Parts List. Universal Utensil Washer FV V / 460V / 60HZ 3P / MIKE 2

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

s l it l on for Infrared Heaters

Installation and servicing instructions

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

PRO 2000i LOW LEVEL DEPOSITOR

SERVICE MANUAL. Kleenmaid SMART oven OMFHS6010

PORTABLE ROLLER OVEN Part No CONTENTS DESCRIPTION

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

Operating Instructions. PowerFill. Automatic Granulate Conveyor for perfectmelt SE

Bona DCS70/Portable DCS Manual and safety instruction

B 40 C Bp B 40 W Bp. Register and win! /13

Effective october 14, 2014

SERVICE MANUAL DISHWASHERS DIVA ACCESSIBILITY DISHWASHERS

MANUAL SWEEPER GUIDE. Model 920. Please make sure you read the instruction manual below and clear the operation before you use this sweeper.

new new Industrial plugs and sockets

Parts and Service Manual

Assembly- and Usermanual. Rainmaker. Code No GB. Edition: 09/2007

E35 CONVECTION OVEN SERVICE MANUAL

Service Documentation Market Release 7/84. Braun Kitchen machine KM 32 B 4209 with lamp

MJC Cartridge Filter Unit Operation & Maintenance

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

Installation & Operation Instructions Nr _EN_Manual

Models Series Series

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

1. Plug electric cord to appropriate 110V 220V electrical outlet. Push the off/on switch to fill position.

Tornado Operations & Maintenance Manual

KEEP FOR FUTURE REFERENCE 1 SCFM NOMINAL AIRFLOW SINGLE VACUUM SYSTEM DC-VOLTAGE POWER SYSTEM WITH MANUAL VALVE

Bona Portable DCS Manual and safety instructions

Thermostatic valve bodies

LIMITED LIFETIME WARRANTY

SELF-PRIMING JET PUMPS

JUNEAU JUN. 08/51193/0 Issue 0

AquaReef Cube. Inspiring Excellence in Fish Keeping!

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

Scrubber User Manual

Service Manual. Rev.1.0 February 2015 SG-30 P 5510 M

SAFIRE 1600D, 1800D and 2100D Diesel / fuel oil heaters USAGE, INSTALLATION AND MAINTENANCE

COS-101 NON SELF FLUSHING COMBI REPLACEMENT PARTS LIST

DC200 Digital Dispenser Operating Manual

Salt Spray Cabinet. Manual. Model Ref.: VF7705 (500 liter) VF7710 (1000 liter)

Rota- Station and Plus Instructions

OPERATION AND MAINTENANCE MANUAL DETERGENT PERISTALTIC PUMPS RINSE AID PERISTALTIC PUMPS

aquaphyll TM QUAD Wall Mounted Chemical Dispensing System

Model: 3508H 3508L 3508M. Part List US-English

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL AUTOBOOSTER IMPORTANT SAFETY INFORMATION

OWNER S MANUAL. How to install, operate and maintain your. EcoWater Systems Automatic Sediment Filter. EcoWater Systems Poland

Shop. Item Information. Rotavapor R-300 B-305, SJ24/40, C, P+G, WB, 110V. Send item information. Show item in shop. Add item to cart.

Transcription:

operation manual SAUNA-VII (07/05) page 1 of 14 SAUNA- Plus VII Table of contents page 1. Function... 2 2. Technical Data... 3 2.2 The controller... 3 2.2.1 Cycle - pause in minutes... 3 2.2.2 Splash quantity... 3 2.2.3 Programme and test switch... 4 2.2.4 Indications of the controller... 4 2.2.5 Main switch... 5 2.2.6 Pre-indication of the splash... 5 2.2.7 Adjustment of the dosing... 5 3. The dosing pump... 6 3.1 Changing the hose set... 6 3.2 Dosing valve... 7 3.3 Fragrance canister... 7 4 Installation / Taking the unit into operation... 7 4.1 Installation... 7 4.2 Electrical connection... 8 4.3 Splash sprinkler... 9 5 Maintenance... 10 5.1 Changing the canister... 10 5.3 Checking the dosing valve... 10 5.4 Cleaning the splash sprinkler... 10 5.5 Cleaning the protection filter... 10 5.6 Checking the press switch... 11 5.7 Trouble shooting... 11 6 Wiring diagramme... 12 6. Spare parts list... 13 6.1 Pump and controller... 13 7.2 Water part... 14

operation manual SAUNA-VII (07/05) page 2 of 14 1. Function The splash automatic SAUNA-Plus VI doses the splash full automatically to the sauna oven. The dosing cycle, the intensity of the splash (quantity of water) and the arome-intensity (quantity of fragrance) are adjusted individual by 3 rotary knobs. knob for fragrance knob for water rotary knob for cycle 10 to 60 minutes programme and test switch pilot lamps LED 1 2 3 4 5 6 7 8 9 For the dosing the solenoid valve (4) opens and the splash water flows to the Sauna-oven. The water is accumulated at the diaphragm that is installed behind the pressure switch (5). A certain pressure is built up. If this pressure gets higher than 1,2 bar the fragrance dosing released, the dosing pump (8) doses the adjusted fragrance quantity over the dosing valve (9) into the water that streams to the oven. A a result it is ensured that the fragrance concentrate is only dosed when there s pressure in the water tubing. Additionally the installed security combination (non-return valve + blower) (3) ensures that no splash water is sucked back into the supply tubing when there s a sudden pressure loss (according to DIN 1988). A locker ball valve ½ (1) and a fine filter (2) are switched in in front of the solenoid valve. Attention! For the prevention of a flooding of the Sauna-room the Sauna-Plus has necessarily to be locked electrical with the Sauna-oven. The internal time delay of app. 30 minutes prevents the first splash onto the cold oven. If necessary the time delay can be switched-off (e.g. at an external start of the splash).

operation manual SAUNA-VII (07/05) page 3 of 14 2. Technical Data The unit consists of: - water connection ½ female thread (app. 150l per hour) - solenoid valve ½ - peristaltic pump 12-24VDC for fragrance - controller with connector for ore-indiation of the splash 230VAC - connector for push-button or external start device - voltage supply 230VAC 1,25A - splash sprinkler 3/8 female thread - measures 44x41x17 cm - fragrance: up to 15 ml pro Aufguss - water consumption: up tp 800 ml per splash at adjustment 100% - cycle time: 10-60 Minuten options - tube cutter (if the splash tubing does not fall) - enlargement for the splash sprinkler - connections for PTFE hose 6x1 - push-button for external control - clock-timer 2.2 The controller 2.2.1 Cycle - pause in minutes The cycle time (time from splash to splash) is adjustable from 10 to 60 minutes. After the lapse of the cycle time the times for the dosing of water and fragrance run accordingly. The operation time of the fragrance dosing is limited to the opening time of the solenoid valve by the pressure switch. If the unit is operated externally (e.g. by push-button) the pause time is according to a locking time in which no further splash can be started. Splash quantity The dosing times are adjustable by the rotary knobs from 0 to 20 seconds. During this time the max. quantity that is dosed is 0.8l water with 15ml of fragrance. Attention: fragrance can only be dosed into flowing water!!!

operation manual SAUNA-VII (07/05) page 4 of 14 Programme and test switch The programme and test switch is to choose the operation programmes and to test all functions of the SAUNA-Plus-VII: - operation: controlled internally with cycle and splash quantity - operation with push-button: start of the splash by external pushbutton and adjustment splash quantity cycle/pause is according to locking time - operation with clock timer: start of the splash according to exactly adjusted time and according to the adjustment of the splash quantity - T-splash: a splash is started, afterwards the operation LED blinks, the controller waits for a readjustment - T-pump: test of the fragrance pump for 20 seconds, afterwards the operation LED blinks, the controller waits for a readjustment - T-valve: test of the solenoid valve for 20 seconds, afterwards the operation LED blinks, the controller waits for a readjustment - T-pressure: test of the pressure switch (see 5.6) - T-indication: test of the pre-indication for 20 seconds, afterwards the operation LED blinks, the controller waits for a readjustment Indications of the controller The operating state and the function sequence is indicated by three LED s at the controller. green operation is activated shines at standard opearation or if test function blinks at a disfunction or after the lapse of a test programme yellow splash indication shines according to the adjusted preindication time of the splash (see 2.2.6) yellow splash shines during the splash

operation manual SAUNA-VII (07/05) page 5 of 14 2.2.5 Main switch You find the illuminated main switch (for switching the unit on & off) on the left side of the controller housing. 2.2.6 Pre-indication of the splash A pilot lamp that indicates the coming splash can be connected to the controller. The lead time can be adjusted to 0 30 60 or 120 seconds (see wiring diagramme). 2.2.7 Adjustment of the dosing The cycle time (time from splash to splash) is adjusted by the left rotary knob from 10 60 minutes. After the lapse of the cycle time the times for the dosing of water and fragrance run accordingly. The dosing times are adjustable by the rotary knobs from 0 to 20 seconds. During this time the max. quantity that is dosed is 0.8l water with 15ml of fragrance.

operation manual SAUNA-VII (07/05) page 6 of 14 Attention! If you switch the unit on the first splash always starts with a delay of 30 minutes (set up ex works). This switch-on delay can be switched-off manually (see wiring diagramme). The fragrance dosing is only unlocked if water flows through the unit. 3. The dosing pump For the fragrance dosing a peristaltic pump that conveys smallest dosing quantities is used, even when there are gas- or air bubbles in the suction tube. Revolving rolls push the dosing hose against a walling whereby the the liquid in the hose is pressed out in front of the rolls and sucked back behind them. It is extraordinary safe in its function an in addition to this very easy to handle (see mounting). Fragrance concentrates are extremely aggressive. The used dosing hose is resistant against the most concentrates that are common in trade. Lifetimes from some months to some years are possible. But there are also concentrates against which the hose in not resistant. So we are not able to provide a warranty in this case! 3.1 Changing the hose set pump housing safety disc hose set hose holder suction side pressure side Remove the transparent pump cover and the yellow roller cover. To change the hose set the suction and pressure connections have to be pulled forward. Turn the roller to the right and pull out the pump hose over the cut out at the roller. On reassembly reverse this process. At the installation act contrariwise.

operation manual SAUNA-VII (07/05) page 7 of 14 3.2 Dosing valve A back pression of water resp. a emptying of the dosing tube is prevented safely by the use of a spring-loaded non-return valve. The valve body is completely manufactured of stainless steal, hose connection 4x1 mm male thread 3/8. 3.3 Fragrance canister The SAUNA-Plus VII is delivered to be mounted on the wall, the fragrance canister (volume 1.5 l) is pre-mounted at the mounting plate. 4 Installation / Taking the unit into operation 4.1 Installation output for the preindication of the splash security device according to DIN 1988 water supply cold ½ options clock timer Push-button for external start of the splash splash tubing - should be installed falling splash sprinkler grommet 3/8 thread power socket 230V/AC interlocked with the oven walling

operation manual SAUNA-VII (07/05) page 8 of 14 The dosing unit SAUNA PLUS VI is delivered in a state ready for operation. It has to be mounted on place that is accessable easily and a bit higher than the oven. The installed security device according to DIN 1988 is useable for non-toxical fragrances for sauna splashs. A second pre-condition is a free outlet. If the tubing tends upwards to the oven a more significant security device (tube cutter) has to be installed. If demanded the tube cutter (article no. 14872) can also be pre-installed ex works. The connection for the water supply at the ball valve is ½, for the splash tubing 3/8". The fragrance canister has to be filled and the suction tube has to be hung into it so that its end reaches the bottom of the canister.the roller of the pump is packed seprately for transport and stock-taking to prevent a deformation of the dosing hose. Insert the roller before taking the unit into operation (see 3.1). 4.2 Electrical connection To prevent that there is a dosing off-time of the sauna operation time, the electric connection (power socket 230V) has to be locked by the controller for the sauna oven. The first splash comes after app. 30 minutes after the overplugging of the voltage.

operation manual SAUNA-VII (07/05) page 9 of 14 4.3 Splash sprinkler The scope of delivery includes a splash sprinkler made of stainless steel (16) to distribute the water drops over the stones of the oven. Connection for splash tubing is 3/8 female thread. Longer splash tubings are deliverable on demand. To prevent a back flowing if there s a longer splash tubing it is possible to install a weak spring loaded non-return valve before the oven. If a non-return valve is installed a tube cutter is absolutely necessary! Option: For the assembly and safe fixing of the splash sprinkler, we offer a grommet with two threads 3/8 made of stainless steel. About 10-15cm over the oven, a app. 18mm hole is drilled into the sauna wall. Furthermore, the wall holder with the rosette is pushed inside. The rosette is fixed together with the delivered V4A screws on the sauna wall. Now the splash sprinkler can be screwed-on over the sauna stones. Use only teflon band for sealing to keep the cleaning of the sprinkler simply. wall holder option splash sprinkler scope of delivery

operation manual SAUNA-VII (07/05) page 10 of 14 5 Maintenance 5.1 Changing the canister Release the canister lid from the empty canister and refill it. Make sure not to overfill it. 5.2 Checking/ changing the dosing hose (see 3.1) The hose set of the pump is exposed to a mechanical anch chemical wear. For this reason the pump hose has always to be checked when the fragrance is refilled. This is unavoidable to recognize damages in time and to change the pump set. In general, the pump set has to be changed every year. In case of aggressive fragrances, it hast to be changed more often. 5.3 Checking the dosing valve Some fragrance concentrates lead to disposals in the dosing tube and in the dosing valve. In this case water may be pressed back at the splash, especially if the dosing hose is already damaged. For this reason check the dosing valve half a year, resp. when there s a need to check it. For this purpose release the dosing hose and screw out the dosing valve. If you blow through the valve from the screw-in side it has to be hermetically sealed. If this is not the case flush it with water from the connection side. If this leads to no success insert a new valve. 5.4 Cleaning the splash sprinkler After a certain operation time the splash sprinkler fossilises inevitably. For the cleaning screw off the sprinkler and clean it mechanically with weak acid. If you screw it up again Use only teflon band for sealing to keep the cleaning of the sprinkler simply. 5.5 Cleaning the protection filter Depending on the contamination of the fresh water, the filter has to be cleaned in the supply. This is especially necessary shortly after the startup as there can occur some impurities in the pipeline and in the water. Therefore lock the ball valve, screw off the sealing plug of the filter, pull out the filter element and clean it up by flowing water. Install it again afterwards. Pay attention that the sealing is not damaged.

operation manual SAUNA-VII (07/05) page 11 of 14 5.6 Checking the press switch Adjust the programme switch to T-pressure. The splash indication LED shines for five seconds with a delay of 2 seconds. Afterwards, the solenoid valve is switched on and water flows to the oven. The LED splash shines. After the lapse of the test programme, the LED operation blinks. The controller waits for a new adjustment. If a LED blinks during the checking procedure, the pressure switch is adjusted wrongly or it is defect. The test is stopped immediately. 5.7 Trouble shooting Fault: LED splash report blinks: LED splash blinks: Solution: - turn the adjustment screw a half rotation to the right and repeat test - change the pressure switch - water pressure too low, open valves and clean filter - turn the adjustment screw a half rotation to the left and repeat test - change the pressure switch no fragrance dosing no aroma in the Steam Room? - Fragrance canister empty? - Does the pump run? Test function (see above). - Check the function of the pump: Pull the suction hose of the pump out of the fragrance canister does a air bubble appear in the hose? Is it aspirated? If yes, the suction function of the pump works. Is the roller of the pump rotating? Consider: If the water pressure is low the pressure switch locks the fragrance dosing. This is to ensure that fragrance oil is not dosed onto the oven without water. - Check the pump hose on cracks, deformation. - Check the roller of the pump on tracks of wear, springs broken, is the hose mounted correct? - Check the dosing valve (blocked, clotted?) Remove the dosing tube from the valve by opening the cap nut of the hose connection (Pay attention that no fragrance splashes out as the hose is on pressure). Switch-on the pump. If fragrance is pressed out of the tube the pump works properly. Unscrew the dosing valve of the steam tube and make the same test. If no fragrance is pressed out of the dosing valve it is blocked. no spalsh? - Is the unit switched on? Does the LED operation at the controller shine? Check the fuses! - Is the splash sprinkler fossil? - Check the supply pressure if the pressure is too low the pressure switch will switch off the unit

operation manual SAUNA-VII (07/05) page 12 of 14 - Open all ball valves. - Clean filter (central filter in technical room?) - Test every single function/ component with the test switch. 6 Wiring diagramme

operation manual SAUNA-VII (07/05) page 13 of 14 6. Spare parts list Pump and controller The peristaltic pumo Sa transparent pump cover retaining washer holder roller pump hosuing felt sealing diaphragm motor mounting screw electrical connection Identification Article no. Fragrance pump lid for pump housing.... 14259 safety disc for roller Sa.... 13633 roller acid pump.... 12609 acid pump housing.... 14140 grommet felt.... 14166 grommet felt EPDM.. 12709 pump motor 13557 mounting screws.... 17067 hose holder with dosing hose... 13358 dosing hose with hose clamp... 12782 Control housing ABS with imprint.... 16878 knob for control board.... 11031 valve plate sauna Plus VII... 17009 seesaw switch... 12764 protection 315 ma... 11493 protection 1,25 A....11361

operation manual SAUNA-VII (07/05) page 14 of 14 7.2 Water part ball valve ½ filter ½ messing protection group solenoid valve sipon pipe PE 4x1 lid for canister canister pressure switch with cap tube VA 2 T-Stück dosing valve 3/8 für fragrance flexible pressure tubing PTFE 4x1 Identification Article no. ball valve ½ MS... 10423 oblique sitting filter ½ MS.... 11479 protection group.... 11465 solenoid valve Va ¼.... 15072 solenoid valve connector... 13082 dosing tube PE 4x1... 12064 lid for canister... 13420 canister 1550 ml...13418 pressure switch ½... 11336 protection cap for pressure switch...11337 dosing tube sauna 1/4"-3/8" V4a... 16865 dosing valve for fragrance 3/8"... 15108 dosing tube PTFE di 4x1mm... 10432