Sonos-SB Siren/Beacon

Similar documents
Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon

BX-MDI8 Input module for SecuriLine extended

AP200 SERIES INTELLIGENT ALARM DEVICES

AP200 SERIES INTELLIGENT ALARM DEVICES

SecuriFire SecuriLine extended board B5-DXI2

XP95 Sounder VAD Base

SecuriFire. SecuriLine Unit B6-LXI2. Technical Description. Securiton AG Alpenstrasse Zollikofen Switzerland

X10 Mini, Midi & Maxi

Mounting Instructions for Genius Hx

SOUNDER WITH BEACON FOR FIRE DETECTION PANEL

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

Optical-Audible Signal Devices

Conventional Audible Visual Range

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

Pilot devices Stacklights Signal beacons

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

VTG-32E Spatial Sounder 24Vdc EN54 part 3 approved

Conventional Fire Detection

Combi B Alarm box. Mounting instructions

EN54-23 Beacons & Sounder Beacons

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Interbases. Sinteso FDSB221, FDSB228, FDSB229

INSTRUCTION MANUAL (ATEX / IECEx)

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23

Evacuate everyone Sonos Pulse & Nexus Pulse

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Fire Signalling. Signalling Solutions

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

INSTRUCTION & SERVICE MANUAL

Xenex Conventional Fire Detection & Alarm System

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

Call stations and extensions

Explosion Proof Combination Signal db (A) / 5 Joule

Fire Signalling. Signalling Solutions

SERIES 65 ENGINEERING PRODUCT GUIDE

Product Manual Standard Asserta Sounder Range

Bulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices

Addressable Detectors & Bases

MINERVA MZX125 Digital Addressable Fire Detection System

Opal TM AV Devices. Data Sheet. Benefits

Multi Tone Alarm Sounders A

Reflective Optical Beam Smoke Detector User Guide

First Revision No. 82-NFPA [ Section No ] Submitter Information Verification. Committee Statement. 2 of /21/2013 1:03 PM

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

SecuriSens LIST Product Catalogue 2015

SP40S-D. Kingfisher Company, inc. Features: Description:

E2S Datasheet v10a

Danfoss gas detection Controller unit

DC1192 Input /Output module

Mimic display driver, LED ribbon cable

CONVENTIONAL AUDIBLE VISUAL

4) Intrinsic Safety Certification

Opal TM AV Devices. Data Sheet. Benefits

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

FCCP 200: Fume-cupboard indicator and monitor

Danfoss gas detection units

Danfoss gas detection units

CHILLGARD M-100. Refrigerant Sensor. Operating Manual. Order No.: /02

FlexSQUARE Square shaped beacons

FDA241, FDA221 Siemens ASD

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

DT8016AF4 / DT8016AF5 DUAL TEC Motion Sensor with Anti-Mask Installation Instructions

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

EXTINGUISHING AGENT RELEASE MODULE

Architectural and Engineering Specification for a. Flash / Flare

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Arteor TM LCS2 Cat. 6A UTP RJ 45 socket

Fire control panels FC360

Figure 1. Figure 2. See notes 1 and 2 below.

Intelligent addressable fire alarm control panel

MINERVA MZX125. Digital Addressable Fire Detection System

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

Quick Selection Guide Fire Systems LSN Periphery

Version 3 Controls for smoke and natural ventilation. CompactSmoke WSC 310 / WSC 320 STANDARD Smoke control panel 10-20A

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

On the job around the clock 24/7: Fire detection systems

INSTRUCTION MANUAL (ATEX)

Safety control unit 471 M41 H31. for 4 to 32 sensors, with safety and control outputs. Use. Models. + PLe according to EN ISO

Fire Signalling. Signalling Solutions

Vega Devices.

FSLIMPRO

Consultant Specification AGILE Wireless Fire Detection System

COMPACT FLAME CONTROLLER CFC 2000

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Half-Dome. the Design-Tower. Compact

Power Supply Display Module PSDM. Installation and Operation Manual

EFBW series - BiWire Ultra control panel

Interface and EOL Modules 8

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

WARNING FIRE DOOR CLOSING

ASA linear smoke detector

TX6831 Data Sheet. Features. Benefits

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

Danfoss gas detection unit Type GD Heavy Duty

Input module, input/output modules

Transcription:

Sonos-SB Siren/Beacon Audible/optical signal transmitter compliant with EN 54-3 and EN 54-23 for fire alarm systems, in red and white. Wall mounting (category W) and ceiling mounting (category C) for indoor applications, also with deep base for outdoor applications. Fig. 1 Sonos-SB The Sonos-SB audible/optical signal transmitter is compliant with EN 54-23 and serves to signal a fire alarm audibly and optically in buildings; with an additional IP65 base it can also be used outdoors. The signal transmitter can be mounted on the wall (category W) or on the ceiling (category C). It is available in a red housing with a red light and in a white housing with a white light. Sonos-SB features Housing and light colours: red and white 2 adjustable flashing speeds 6 (32) adjustable tones in 2 volume levels For indoor applications; with deep base also for outdoor applications Ceiling mounting and wall mounting versions Complies with EN 54-3 and EN 54-23 Interfaces DIP switch setting for flashing frequency, volume and tone type (X2) DIP Position Function 1-5 See belotion Tone selec- 6 ON Attenuation -8 db (A) OFF Max. volume 7 ON 1 Hz OFF 0.5 Hz 32 different tone types can be set using DIP 1-5, of which the following are approved for use in fire alarm systems. Tone DIP 1=ON 12345 Sound level @ 1 m/90 ±3 db (A) Continuous tone 970 Hz 00000 97 Alternating tone 800/970 Hz, 2 Hz 00001 98 Rising/falling tone 800-970 Hz, 1 Hz 00010 98 Alternating tone 554 Hz / 440 Hz 00101 95 Slow whoop 500-1200 HZ 00110 97 DIN 33404 1200-500 Hz, 1 Hz 01100 97 The complete table of tones can be found on page 4 of this document Terminals (X3)/(X4) Sonos-SB audible/optical signal transmitter Terminal Designation Function 1 GND (-) 2 - / L- GND (-) 3 IN+ / L+ 24 V (+) 4 OUT+ 24 V (+) 5 (5) / S Screen IP65 base Seating the signal transmitter plug connector (X1) SECURITON AG Alpenstrasse 20 CH - 3052 Zollikofen Switzerland T 811 145 en 1 / 5

Measurement value table in db (A) at maximum volume, 1 m from point of reference compliant with EN 54-3, with DIN tone. Planning: wall with white light Planning: ceiling with red light Planning Planning is to be carried out in accordance with the applicable standards and directives. The Sonos-SB is connected either via an addressable loop module or a unit of the control panel. The audible and optical features can only be actuated simultaneously they cannot be actuated separately from each other. Power can be supplied from the control panel or an external energy supply source. When it is operated on an addressable loop module, it is imperative that an external power supply is used. For each output, up to 51 (0.5 Hz) or 28 (1 Hz) Sonos-SB units can be planned, whereby the maximum line length must be taken into consideration. Transmission Horizontal Vertical Power supply 15 45 75 105 135 165 17 V 85 83 90 90 83 85 60 V 89 86 93 93 86 89 17 V 85 83 90 90 83 85 60 V 89 86 93 93 86 89 When planning the number of signal transmitters, the relevant category (mounting location) and the light colour must be taken into account. The following space coverages can be achieved in accordance with EN 54-23 by means of different variants: Category Light colour Specification Space coverage W (wall) Red W-2.4-7.5 1) 56 m 2 135 m 3 W (wall) White W-3.1-11.3 1) 127 m 2 395 m 3 C (ceiling) Red C-3-8.9 2) C-3-6.2 3) 62 m 2 38 m 2 186 m 3 114 m 3 C (ceiling) White C-3-15 2) C-3-10.6 3) 176 m 2 112 m 2 530 m 3 337 m 3 1) W-x-y = maximum mounting height-width of a square space 2) C-x-y = maximum height-diameter of a cylindrical space 3) C-x-y = converted from a cylindrical to a square surface Planning: ceiling with white light Example of number of required signal transmitters based on space size Space size (L x W) 5 x 5 m 10 x 10 m 15 x 15 m Wall, red light 1 4 4 Wall, white light 1 1 4 Ceiling, red light 1 4 9 Ceiling, white light 1 1 4 Planning: wall with red light Mounting / installation To remove the signal transmitter from the base, screw out the safety screw clockwise and remove. Drill out the mounting holes and cable entry on the IP65 base at the indicated points. Drill mounting holes (see dimensioned drawing), insert cable, and screw the base onto the mounting surface. For the wall mounting, ensure that the marking on the base (see graphic) points downward at the centre so that the signal transmitter is correctly aligned. Connect the cable to the terminal block in the base (see wiring). 2 / 5 T 811 145 en Sonos-SB

Set the DIP switch and insert the signal transmitter into base so that the two long markings face each other. Next, rotate clockwise toward the short marking and fasten the safety screw. Via BX-IOM module Dimensioned drawing (mm) Wall variant Ceiling variant Last signal transmitter First and all further ones Signal transmitters Via B5-OM8 board (SecuriFire 3000), B6-EIO unit (SecuriFire 2000) IP65 base Connection Connection of monitored signal transmitters (primary lines) for cable type 2 x 2 x 0.8 mm. Number of signal transmitters Maximum line length 1) (m) 0.5 Hz 1 Hz Total power consumption 2) (A) 0.5 Hz 1 Hz 1 798 570 0.050 0.070 2 532 347 0.075 0.115 3 399 249 0.100 0.160 4 319 195 0.125 0.205 5 266 160 0.150 0.250 6 228 135 0.175 0.295 7 199 117 0.200 0.340 8 177 104 0.250 0.385 9 160 93 0.300 0.430 10 145 84 0.350 0.475 1) Including the line length to the external power supply 2) Including EOL resistor (680 Ohm) Last signal transmitter First and all further signal transmitters Sonos-SB T 811 145 en, 25.07.2015 3 / 5 First edition: 25.07.2015 Bet The product specifications contained in this document are subject to change without prior notice. Copyright by Securiton

Table of tones Tone DIP, 1=ON 12345 970 Hz 00000 800 Hz/970 Hz @ 2 Hz 00001 800 Hz 970 Hz @ 1 Hz 00010 970 Hz 1s OFF/1s ON 00011 970 Hz, 0.5s/630 Hz, 0.5s 00100 554 Hz, 0.1s/440Hz, 0.4s (AFNOR NF S 32 001) 00101 500 1200 Hz, 3.5s/0.5s OFF (NEN 2575:2000 Dutch Slow Whoop) 00110 420 Hz 0.6s ON/0.6s OFF (Australia AS1670 Alert tone) 00111 1000 2500 Hz, 0.5s/0.5s OFF x 3/1.5s OFF (AS1670 Evacuation) 01000 550 Hz/440 Hz @ 0.5 Hz 01001 970 Hz, 0.5s ON/0.5s OFF x 3/ 1.5s OFF (ISO 8201) 01010 2850 Hz, 0.5s ON/0.5s OFF x 3/1.5s OFF (ISO 8201) 01011 1200 Hz 500 Hz @ 1 Hz (DIN 33 404) 01100 400 Hz 01101 550 Hz, 0.7s/1000 Hz, 0.33s 01110 1500 Hz 2700 Hz @ 3 Hz 01111 750 Hz 10000 2400 Hz 10001 660 Hz 10010 660 Hz 1.8s ON/1.8s OFF 10011 660 Hz 0.15s ON/0.15s OFF 10100 510 Hz, 0.25s/610 Hz, 0.25s 10101 800/1000 Hz 0.5s each (1 Hz) 10110 250 Hz 1200 Hz @ 12 Hz 10111 500 Hz 1200 Hz @ 0.33 Hz 11000 2400 Hz 2900 Hz @ 9 Hz 11001 2400 Hz 2900 Hz @ 3 Hz 11010 500 1200 Hz, 0.5s/0.5s OFF x 3/1.5s OFF (AS1670 Evacuation) 11011 800 Hz 970 Hz @ 9 Hz 11100 800 Hz 970 Hz @ 3 Hz 11101 800 Hz, 0.25s ON/1s OFF 11110 500 Hz 1200 Hz, 3.75s/0.25s OFF (AS2220) 11111 SECURITON AG Alpenstrasse 20 CH - 3052 Zollikofen Switzerland T 811 145 en 4 / 5

Article numbers / spare parts Short designation art. no. CH no. Art. no. Sonos-SB audible/optical signal transmitter wall housing, red light, flat base 30-6300009-01-01 Sonos-SB audible/optical signal transmitter wall housing, red light, deep base 30-6300009-02-01 Sonos-SB audible/optical signal transmitter wall housing, white light, flat base 30-6300009-03-01 Sonos-SB audible/optical signal transmitter wall housing, white light, deep base 30-6300009-04-01 Sonos-SB audible/optical signal transmitter ceiling housing, red light, flat base 30-6300010-01-01 Sonos-SB audible/optical signal transmitter ceiling housing, red light, deep base 30-6300010-02-01 Sonos-SB audible/optical signal transmitter ceiling housing, white light, flat base 30-6300010-03-01 Sonos-SB audible/optical signal transmitter ceiling housing, white light, deep base 30-6300010-04-01 Technical data Operating voltage 17 to 60 VDC Power consumption typically 24 V @ 0.5 Hz 25 ma @ 1 Hz 45 ma Switch-on current Category W 520 ma for 3.6 µs Category C 510 ma for 3.6 µs Flashing frequency 0.5 or 1 Hz Light colour red or white Sound level, DIN tone, typically 24 V 97 db (A) Attenuation 8 db (A) Protection type Flat base IP21C Deep base IP65 Permitted ambient temperature -10 to +55 C Dimensions (D x H) Wall, flat base 100 x 100 mm Wall, deep base 100 x 122 mm Ceiling, flat base 100 x 94 mm Ceiling, deep base 100 x 117 mm Housing Polycarbonate Connection Screw terminals, max. 2.5 mm 2 Cable entry Flat base Rear side Deep base Rear side and lateral M20 Weight Flat base 220 g Deep base 270 g VdS approval G214108, G214106 Declaration of performance (DoP) Wall, red light 0832-CPR-F0149 Wall, white light 0832-CPR-F0010 Ceiling, red light 0832-CPR-F0147 Ceiling, white light 0832-CPR-F0008 Sonos-SB T 811 145 en, 27.07.2015 Bet 5 / 5 First edition: 27.07.2015 Bet The product specifications contained in this document are subject to change without prior notice. Copyright by Securiton