RES-210 (-211, -220, -221) / RES-420

Similar documents
RESISTRON. Replacing RES-102/RES-420. Replacement Instructions. Comparison of RES-102 / RES-420. Dimensions. Temperature indication (actual value)

RESISTRON RES-408. Operating Instructions. Important features

RESISTRON RESM-5. Operating Instructions. Important features

FlameGard 5 MSIR HART

RPM1600 Series Room Pressure Monitors

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

FlameGard 5 UV/IR HART

Operating Manual UV Monitor UVT 18

FIL-SPL Flow-through heater for central heating USER MANUAL

S F IT 6" / 8"HES. Quick Installation Guide. franklinwater.eu

SCAN200E USER S MANUAL

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

CU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB

ELECTRONIC HUMIDISTAT: H270

ETO 2 - Controller for ice and snow melting

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

SCHMIDT LED Measured Value Display MD Instructions for Use

Deltapilot S FMB70. Functional Safety Manual. Level and Pressure Measurement with Output Signal ma

Mark 25 Ultrapure Water Conductivity Analyzer

CONTROL DEVICE SLIDETRONIC HD

Dry Contact Probe DCP (#30008)

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

MultiFix Central unit

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

ELECTRONIC HUMIDISTAT: H200

INSTALLATION & USER MANUAL

Reciprocating Chiller

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

INSTRUCTION MANUAL. Software Revision Card 3.2 DOCUMENT SES-KS E REV. 3

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Oxygen & Carbon Dioxide Analyser

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

EST User Manual. (Please read this manual carefully before using)

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

OVEN INDUSTRIES, INC.

Instructions for the fan motor control system, SILVER C

Model B-350Touch Control Panel Operating Instructions

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

Stand Alone DYNAGARD SP Operation Manual

7. ON/OFF Controller (CZ-ANC2)

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

RTD TEMPERATURE SENSING SYSTEM

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

ACS-30-EU-VIA-DU-20-MOD

Installation & operating manual. Swimming pool water. UV disinfection device UV10+

READ AND SAVE THESE INSTRUCTIONS

Memcom Emergency Telephone

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

2704 Controller Melt Pressure Controller

Control box FSTronic DES-FS

OUMAN EH-800 Heating controller USER MANUAL

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

MultiFix Central unit

Platinum Touch/Rotem One Touch

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

Electronic Emergency Telegraph. TG-1 and TG-1A

Pioneer-R16 Gas Monitor Operator s Manual

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

Ventilation control for SupraBox COMFORT 800 to 5000

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

TEMPERATURE CONTROLLER (STANDARD MODEL)

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

Operating Manual Hand-held Measuring Device GMH 3690 GL. for Gaseous Oxygen and Temperature with Alarm Function

JDDT1 - Single Stage Digital Thermostat

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Introduction. OM-THA2

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Dohse Aquaristik GmbH & Co. KG. T-Control Pro. Item no Status: 03/2013. Dohse Aquaristik GmbH & Co. KG

BWAC Steuerung. Kochendwasser- Energiesparreinigung. Art.-Nr Version 1.0

Pump-Down Controller MODEL 4052

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

User Manual. Dryer Controller M720

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Troubleshooting Thermo Scientific LevelPRO Gauges

BSR Addressable Fire Detection control panel. Installation operation manual

Programmable Interactive User Manual

Quick-Start Guide Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input Models and

3. Thermal switch (70 o C thermostat) with a 3 m connection cable

Settings and Maintenance of the CombinAir

2012 Toolbar & NH3 Operators Manual

Refrigeration and Air Conditioning Controls. User s manual. Degree Master Controller in AKC 55 Systems ADAP-KOOL REFRIGERATION AND AIR CONDITIONING

Setup & Operation Index

Manual Supplement. Model Number: 8680-N2. Communications Protocol. Contents of this manual supplement include:

PHOSPHAX sc, PHOSPHAX indoor sc

Transcription:

RESISTR GB Replacing RES-2xx/ Replacement Instructions The RESISTR temperature controller can be used as an alternative to the following controllers of the series 200 : RES-210: Analog temperature display, no alarm function RES-211: Digital temperature display, no alarm function RES-220: Analog temperature display, with alarm function RES-221: Digital temperature display, with alarm function The steps that are necessary to convert from RES-2xx-0-x (standard model without modifications) to are described below. These instructions only provide a brief overview of the two controllers. If in doubt, please refer to the latest version of the controller documentation, which is always binding. The convertion from controller types RES-2xx-1-x is not described here. Please contact ROPEX for further informations. Comparison of RES-210 (-211, -220, -221) / Dimensions The front panel cutout dimensions of the RES-2xx and controllers are identical. The features a protective film to IP42 instead of the transparent hood. A transparent front cover featuring IP65 is available as a option. 3.11.03

Set point selection Selection by means of a 10-turn potentiometer with a fine control knob. Selection with step 1 in the software menu. If the controller is active, the set point is also indicated on the display. Temperature indication (actual value) RES-210, -220: Indication on a analog instrument (ATR-x) RES-211, -221: Indication on a digital. instrument (DTR-x) Indication on the 4-line display (dynamic bar and digital value). Zero calibration Zero calibration by means of a 10-turn potentiometer. RES-210, -220: RES-211, -221: The pointer of the indicating instrument must be set to Z (ref. picture) The display of the indicating instrument must be set to 20 C Automatic zero calibration (AUTOCAL) with step 3 in the software menu. Page 2 Replacing RES-2xx/

Alarm output / reset (RES-220, -221 only) RES-220, -221 Indicated by means of a red ALARM LED on the front panel. Reset by pressing the key. Indicated on the display. The error is identified by a numeric code ( documentation). Reset by pressing the key ( HAND ). Manual mode Selected by pressing the HAND key. The red LED is lit continuously. Selected by pressing the HAND key ( Home position is displayed. HAND ) while the Line frequency setting (50/60Hz) Configured with plug-in jumper. Detected automatically in the 47 63Hz range. Automatic detection Replacing RES-2xx/ Page 3

Installation and setup Installation and startup may only be! performed by technically trained, skilled persons who are familiar with the associated risks and warranty provisions. The information provided here offers no more than a brief overview. If in doubt, please refer to the latest version of the controller documentation, which is always binding ( see also section Safety and warning notes of the documentation). Proceed as follows to replace the RES-2xx controller and install/start up the : 1. Switch off the line voltage and verify the safe isolation from the supply. 2. Remove the existing RES-2xx controller. 3. The supply voltage specified on the nameplate of the controller must be identical to the line voltage that is present in the plant or machine. The line frequency is automatically detected by the temperature controller in the range from 47 to 63Hz. 4. Set the DIP switches on the. The settings of the DIP switches on the! are NOT the same as on the RES-210 (-211, -220, -221). Please set these switches in accordance with the ROPEX Application Report in order to avoid malfunctions. New setting ranges on the : DIP-SWITCH The table below compares the two controllers. These settings can be taken as a guide (e.g. when the controller is started up for the first time): U 2 RES-2xx 12345 1 2 3 4 5 OFF U 2 ( V ) 1-10 6-60 20-120 OFF OFF DIP switch 1 1 2 2 3 3 4 3 I 2 5 4 I 2 ( A ) 30-100 60-200 120-400 Old setting ranges on the RES-2xx: U2 ( V) Switch No. 12345 3-10 8-30 20-60 50-80 1 2 3 4 5 5. Install the controller in place of the RES-2xx. The terminals of the two controllers are identical. The existing connector plug-in parts can be used without rewiring. 6. Switch on the line voltage. 7. A power-up message appears on the display when the controller is switched on to indicate that it has been started up correctly. Page 4 Replacing RES-2xx/

8. One of the following states then appears: DISPLAY Home position Shows the SET and ACTUAL temperatures or the dynamic bar Shows error code 104, 106, 109 or 211 Shows error code 101 103, 201 203, 801 or 9xx Go to 9 Go to 9 ACTI Fault diagnosis ( documentation) 9. Select the language and reset the controller to the factory settings. Press the key for at least 2s (to open the Configuration menu). Step 20 is displayed. Select the desired language with the keys. Confirm your selection by pressing HAND. Press the key to display step 21 (factory settings). Press the HAND key to confirm the factory settings (an acknowledgment message appears). Step 22 is displayed next. 10.Set the temperature range to 500 C (Only if you have so far been using an RES-2xx-0-5 controller) Then set "Alloy 20, max 500 C" with the keys in step 22. Confirm your selection by pressing HAND. 11.Return to the Home position Press the key for at least 2s (to return to the Home position or Alarm menu). 12.Calibrate the zero point Activate the AUTOCAL function while the heatsealing band is still cold. Press the key repeatedly until step 3 is displayed. Then select the AUTOCAL funtion by pressing the HAND key. If this function is executed correctly, the Home position is displayed again automatically. If the zero has not been calibrated successfully, an error message appears on the display. In this case the controller configuration is incorrect ( see section Controller configuration of the documentation and the ROPEX Application Report). Configure the controller correctly and repeat the AUTOCAL function. 13.Set the heatsealing temperature (select the set point) Press the key briefly (to display step 1 in the Setting menu). Set the required temperature with the keys. Confirm your selection by pressing. Press the key for at least 2s (to HAND return to the Home position). The set heatsealing temperature is displayed in the Home position. Then activate the "START" signal (HEAT). The indication on the display (actual value and dynamic bar) permits the heating and control process to be observed: If an error code is displayed, please proceed as described in section Error messages of the documentation. The controller is now ready factory settings / as-delivered condition If you accept the factory settings (step 21 in the software menu, see step 9 above), the following defaults are restored: 23 Maximum temperature 300 C 24 Cycle counter 0 Menu step Function 1 Heatsealing temperature 0 C Value 25 Alarm relay Closed by alarm The selected language (step 20 in the software menu) remains set regardless of the factory settings. 2 Hold mode OFF 22 Alloy/range Alloy A20, max. 300 C As-delivered condition: The controller is delivered with the above factory settings and with the language set to "German". Replacing RES-2xx/ Page 5

Menu structure of the Settings Configuration Power-up message Home position 1 Heatsealing temp. 20 Language 21 Factory settings The relevant menu steps are shown on a gray background. 2 Hold mode 22 Alloy/range 3 Autocal? 23 Max. temperature Autocal 24 Cycles 25 Alarm relay 26 Meas. imp. length MOD 1 only Fault Alarm 3 Autocal? Autocal Page 6 Replacing RES-2xx/