Installation and Instructions for Use Outdoor Sensor

Similar documents
Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

System Installation. multi-zone heating

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

condens Instructions for Use Ultracom 2 35 Store G.C. No

Climapro 2. Installation. wireless room thermostat without receiver.

Operating instructions

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

Instructions for Use. To b e l e f t w i t h t h e u s e r. Clearly Solar System. including. Fluropro. Solar Differential Controller

PROGRAMMABLE 7-DAY RF THERMOSTAT

Easicom. Quality, reliability, flexibility

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

The xi Range of High Efficiency Condensing Boilers. hxi Range 12-38kW

Electronic Thermostat With RF

User Manual THR870CUK Programmable Thermostat

Easicom 2. Quality, Reliability, Flexibility

USER INSTRUCTION MANUAL. Autofill Water Boiler

Osprey 2 CFL

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

Instructions for Use Installation and Servicing

System Installation HYBRID BACK-UP

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

Baxi Maxflow Combi FS

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Energy. The power of connectivity

Operating instructions

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Baxi Maxflow Combi WM

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Energy The power of connectivity

Digital Electronic Thermostat With RF

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

Digital Electronic Thermostat With RF

Drayton Digistat +3RF

Fitting & Commissioning Instructions. EcoBlue Combi and System Range. Outdoor Sensor Kit. Kit Part No (System) Kit Part No.

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

Operating instructions

For the heating engineer. Installation manual. Interface 0-10V VR34

User Manual THR842DUK Wireless Digital Thermostat

Supplement to operating and installation manual no for the VR 81 remote control unit

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

User Manual THR872CUK Wireless Programmable Thermostat

ir-range 8G /03.15 Changes reserved.

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

Digital Room Thermostat

Greenstar 12i/24i System

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

PROGRAMMABLE 7-DAY THERMOSTAT

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

TRIPLE CONTROL THERMOSTATIC SHOWER VALVE

Programmable Room Thermostat Installation Instructions

Combi Eco Elite Range. User s Guide and Important Warranty Information

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

Installation Instructions

Operating instructions

SFA Guide to Building Regulations and Solid Fuel Heating

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

evotouch Controller Installation evotouch

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Operating and Installation Manual VRC 430f. Weather compensator controller with radio transmission. For the operator / for the heating engineer

SINGLE LEVER CERAMIC DISC MANUAL SHOWER VALVE

GREENSTAR HIGHFLOW 440/550CDi

Greenstar 12i system / 24i system

LC2200 Level Controller Installation and Maintenance Instructions

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

USERS MANUAL FOR GAS BOILERS

Smartfit S Pack Installation Guide with 24Hr or 7 Day Room Unit

GREENSTAR HIGHFLOW 440/550CDi

Instructions for Use Installation and Servicing

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

E-Combi One E-System ONE

FIRERAY 5000 range USER GUIDE

Operating instructions

Model: RT310RF. Installation Manual

For the operator/for the heating engineer. Operating and Installation Manual VRC 430. Weather compensator VRC 430

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

The Professional s Choice

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

USER GUIDE VOGUE MAX SYSTEM

Greenstar 24i junior / 28i junior

OWNER S GUIDE SEQUENTIAL THERMOSTATIC SHOWER VALVE. 150mm Inlet Pipe Centres. Shower Control. Handles and. may differ depending.

RT 10 RT 10 INSTALLATION, USER INSTRUCTIONS & CUSTOMER CARE GUIDE. Order no

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

Honeywell Homes T3, T3M & T3R

RF Programmable Room Thermostat Installation Instructions

C-Stat 17-ZW User Instructions

AquaNova. Water heater. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

Technical Data Manual

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

Transcription:

Installation and Instructions for Use Outdoor Sensor To b e l e f t w i t h t h e u s e r

General Customer Service: 01773 828100 Technical Helpline: 01773 828300 General and Sales enquiries: Tel. 01773 824639 Fax: 01773 820569 Benchmark places responsibilities on both manufacturers and installers. The purpose is to ensure that customers are provided with the correct equipment for their needs, that it is installed, commissioned and serviced in accordance with the manufacturer s instructions by competent persons and that it meets the requirements of the appropriate Building Regulations. The Benchmark Checklist can be used to demonstrate compliance with Building Regulations and should be provided to the customer for future reference. Installers are required to carry out installation, commissioning and servicing work in accordance with the Benchmark Code of Practice which is available from the Heating and Hot water Industry Council who manage and promote the Scheme. Visit www.central heating.co.uk for more information. Please read these instructions and follow them carefully for the safe and economical use of your boiler. On completion of installation leave the instructions with the user. 2

Contents General Information Contents Page General information 3 Kit contents 5 Section (A) Installer important information 6 Outdoor sensor location 7 Installation 9 Section (B) Configuring the outdoor sensor 13 Section (C) Configuring the outdoor sensor 22 with external Glow-worm Climapro or Climastat controls General The outdoor sensor enables weather compensation by providing an advanced level of modulation, achieving an additional level of efficiency. This control compensates for the outside temperature by modulating the lower radiator temperatures in warmer weather and higher radiator temperatures in colder weather. The outdoor temperature compensation is easily configured using either the boilers interface controls or the interface of an external Glow-worm Climastat or Climapro room control (if fitted). Optimum comfort and efficiency is achieved when used in conjunction with a Climastat or Climapro (in modulating mode). The outdoor sensor can also be used with a conventional on/off thermostat. 3

General Information The installation and the commissioning of the Outdoor sensor has to be carried out by a competent person in accordance with the current regulations. The maintenance and the repairing of the Outdoor sensor will also require the use of a competent person. Documents Please keep these instructions as well as any documents enclosed, for future reference. We accept no liability in case of damage due to the non-compliance of these instructions. Application The outdoor sensor controls the heating demand for the appliance, which is dependant on the outdoor temperature. Any other use is considered as inappropriate and is forbidden. The user will be responsible for any damage caused by any other use. Servicing Clean the case of the outdoor sensor with damp soapy cloth, make sure that no water goes inside the outdoor sensor. Do not use any abrasive cleaning product as they could damage the housing or plastic case. 4

General Information (A) Installer important information Recycling The Outdoor Sensor comprises of many recyclable parts and should be disposed of according to the current WEEE regulations. The packaging should also disposed of according to the current regulations. Kit contents Refer to diagram 1. Kit part number 0020040796. 13663 LABEL INSTALLATION AND INSTRUCTIONS FOR USE LITERATURE. OUTDOOR SENSOR EDGE CONNECTOR Outdoor sensor Diagram 1 Safety instructions and regulations This outdoor sensor is tested and certificated for safety and performance. It is, therefore, important that no alteration is made to the outdoor sensor, without permission, in writing, from Glow-worm. Any alteration not approved by Glow-worm, could invalidate the certification, appliance warranty and may also infringe the current issue of the statutory requirements. Safety instructions WARNING: Incorrect installation can cause electric shock and damage to the outdoor sensor. 5

(A) Installer important information Regulations When installing and commissioning the outdoor sensor, the regulations below shall be observed in their current version. Where no specific instructions are given, reference should be made to the relevant British Standard Code of Practice. Where no British Standard exists, materials and equipment should be fit for their purpose and of suitable quality and workmanship. The installation of this outdoor sensor must be carried out by a competent person in accordance the rules in force in the countries of destination. Manufacturer s instructions must not be taken as overriding statutory requirements. Mandatory WARNING for EEC countries The CE mark on this appliance shows compliance with: Directive 89/336/EEC on the approximation of the Laws of the Member States relating to electromagnetic compatibility. Directive 73/23/EEC on the harmonisation of the Laws of the Member States relating to electrical equipment designed for use within certain voltage limits. 6

(A) Installer important information (A) Outdoor sensor location Technical data Power supply 5V Power consumption <10mW Cable Electrical protection IP 44 Electrical category Dimensions: Height 32mm Depth 86mm 2 core insulated for outdoor use Protection class II Width 46mm (including gland) Outdoor sensor location Refer to diagram 2. The outdoor sensor should be placed on an external North/North-West facing wall of the house. For optimal reading of the outdoor temperature, the device should be placed about 2 / 3 up the wall for buildings of 3 floors or less. For higher buildings, the recommended position is between the 2nd and 3rd floors. It should not be installed sheltered from wind or draughts, nor directly exposed to the sun. The sensor should be placed at least 1 metre from openings and away from permanent or occasional emissions of hot air. 7

(A) Outdoor sensor location 4 13662 1/3 1m 2/3 3 1m 2 1m OUTDOOR SENSOR POSITION (For buildings three floors or less) E S 1m 1/3 2/3 3 2 1 1 OUTDOOR SENSOR POSITION (For buildings higher than three floors) 8 N W OUTDOOR SENSOR POSITION (For buildings three floors or less) Diagram 2

(A) Installation Refer to diagram 3. Remove the front cover, seal and electrical sealing gland. COVER BACK BOX SEAL 13666 Choose the location of the outdoor sensor, refer to page 6. Fit the back box to the wall, see diagram 4. BACK BOX 13667 ELECTRICAL SEALING GLAND Diagram 3 Diagram 4 9

(A) Installation WARNING: Isolate the boiler from the electrical supply. A competant person should make the electrical connections. Use a cable that complies with the specifications given in Technical data, page 7. Route the cable from the outdoor sensor to the boiler electrical cartridge at the boiler, refer to the literature supplied with your boiler for location and access. Refer to diagram 5, thread the cable through the electrical sealing gland. Connect the cable to the electrical connection, polarity is not important. Fit the sealing gland, this secures the cable and gives a water tight seal. Connect the cable to OTC1 and OTC2 connection in the electrical cartridge at the boiler, polarity is not important, refer to diagram 6. Note:Ultracom hxi & Flexicom hx open vent system models only. The edge connector will need to be fitted, see diagram 7. 10 ELECTRICAL CONNECTION ELECTRICAL SEALING GLAND 13668 Diagram 5

(A) Installation OTC 1 and OTC 2 13683 Diagram 6 11

(A) Installation EDGE CONNECTOR 14819 Refer to diagram 8, fit and secure the seal and cover. 13669 COVER SEAL 12 Connection at X41 on main PCB Diagram 7 Diagram 8

(B) Configuring the Outdoor Sensor Configuration of the outdoor sensor is achieved through the Appliance interface controls on the boiler, see diagram below. NOTE: If a Glow-worm Climapro or Glowworm Climastat is fitted, please refer to section C to configure the outdoor sensor. Glow-worm Climapro Appliance interface controls Glow-worm Climastat 13

(B) Configuring the Outdoor Sensor Choosing and Setting Sensor Heating Curve. A gradient must be chosen from the range shown on page 17, labelled 0-9. The decision as to which heating curve should be used is based on two factors: 1. The average minimum outside temperature of the region. 2. The maximum temperature which the heating appliance can provide. NOTE: Consider the level of heat loss in comparison to typical UK heat loss e.g. (double glazing, loft insulation and cavity wall insulation). Method with example. The following example describes the process. The temperatures quoted should be substituted with real values to find the required heating curve. 1. Select the average minimum outdoor temperature expected in your region where the sensor will be installed. For example at the peak of winter the temperature may drop to -5 C. This would be the value selected from the Outdoor temperature C axis. 2. Select the maximum output temperature of the heating appliance from the Heating flow temperature ( C) axis. For example this could be 82 C. 14

(B) Configuring the Outdoor Sensor Plot these two points onto the chart.they intersect the gradient curve labelled 6. The value 6 would be entered into the boiler via the diagnostic menu d.45. Refer to the following diagrams and text to do this. Press and hold the mode button. When the screen is lit orange and displays 0, release the mode button. Running screen is displayed Using the domestic hot water +/- button, scroll through to 35. Press mode button. 15

(B) Configuring the Outdoor Sensor On screen are two blocks of information, d0 in the lower part of the screen in small text. In the top centre of the screen, where the pressure or temperature is normally shown, is displayed the heating part load for the appliance (it will be different for various kw output boilers). For example this could be 18, 38. Using the domestic hot water +/- button, scroll through until d45 is shown in small text. Press mode button once. The large number on the screen then starts flashing. Using the domestic hot water +/- button change the value to 6. Press mode button once. 16

(B) Configuring the Outdoor Sensor Heating flow temperature (ºC) 90 80 70 60 50 40 30 9 8 7 Default curve 6 5 4 3 2 1 0 13664 20 Factory default room temperature setpoint, for weather compensation Minimum outdoor temperature (ºC) 17

(B) Configuring the Outdoor Sensor Adjusting room temperature set point. By default the outdoor sensor aims to provide a room ambient temperature of 20 C. In some situations it may be necessary to have a lower or higher ambient room temperature the adjustment is made in terms of an offset value, which is entered into the appliance via diagnostic menu d.46. Refer to the following diagrams and text to do this. Method with example. Running screen is displayed Press and hold the mode button. When the screen is lit orange and displays 0, release the mode button. 18

(B) Configuring the Outdoor Sensor Using the domestic hot water +/- button, scroll through to 35. Press mode button. On screen are two blocks of information, d0 in the lower part of the screen in small text. In the top centre of the screen, where the pressure or temperature is normally shown, is displayed the heating part load for the appliance (it will be different for various kw output boilers). For example this could be 18, 38. 19

(B) Configuring the Outdoor Sensor For example: 10 C = offset -10 20 C = offset 0 30 C = offset 10 If extra heating comfort is required, the room temperature setpoint can be increased via diagnostic menu d.46. D.46 provides a means to offset from the default 20 C room set point. For example to increase the target room temperature to 22 C set d.46 to the value 2. Range of value d.46: -10 to 10. 20

(C) Configuring the Outdoor Sensor with external Glow-worm Climapro or Climastat controls Choosing and Setting Sensor Heating Curve. A gradient must be chosen from the range shown on page 17, labelled 0.2-4. The decision as to which heating curve should be used is based on two factors: 1. The average minimum outside temperature of the region. 2. The maximum temperature which the heating appliance can provide. NOTE: Consider the level of heat loss in comparison to typical UK heat loss e.g. (double glazing, loft insulation and cavity wall insulation). Method with example. The following example describes the process. The temperatures quoted should be substituted with real values to find the required heating curve. 1. Select the average minimum outdoor temperature expected in your region where the sensor will be installed. For example at the peak of winter the temperature may drop to -5 C. This would be the value selected from the Outdoor temperature C axis. 2. Select the maximum output temperature of the heating appliance from the Heating flow temperature ( C) axis. For example this could be 82 C. 3. Plot these two points onto the chart.they intersect the heating curve labelled 2.5. The value 6 would be entered into the boiler via the diagnostic menu d.45. 21

(C) Configuring the Outdoor Sensor with external Glow-worm Climapro or Climastat controls Making Adjustment on Climastat Refer to your Climastat instructions, section 6 Commissioning. The heating curve is adjusted via Menu 2. Acess to this menu is achieved by following the steps stated in Adjustments. Making Adjustment on Climapro/ Climapro RF Refer to your Climapro/Climapro RF Commissioning Instructions. The heating curve is adjusted via menu COMP which is accessible by procedure stated in the table in the Commissioning section. 22 Adjusting Room Ambient With the heating curve correctly setup for your specific region, the room temperature can be adjusted. This is achieved by increasing or decreasing the setpoint temperature of your Climastat or Climapro/ Climapro RF roomstat. For systems with a Glow-worm Climapro. To adjust the room ambient set point temperature, refer to sections, Setting the Comfort temperature or Central heating temporary override - central heating of the Climapro instructions for use, installation and servicing literature. For systems with a Glow-worm Climastat. To adjust the room ambient set point temperature, refer to section 2 instructions for use of the Climapro instructions for use, installation and servicing literature.

(C) Configuring the Outdoor Sensor with external Glow-worm Climapro or Climastat controls Heating flow temperature (ºC) 90 80 70 60 50 40 30 4 3.5 3 2.5 Recommended for UK 2 1.5 1.2 1 0.6 0.2 Default curve 13682 20 Factory default room temperature setpoint, for weather compensation Outdoor temperature (ºC) 23

0020040798-04 08.09 Because of our constant endeavour for improvement, details may vary slightly from those shown in these instructions. Glow-worm, Nottingham Road, Belper, Derbyshire. DE56 1JT