Heating Controller SDC Remote Heating Controller DHC

Similar documents
Heating Controller SDC Remote Heating Controller DHC

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS

Smile SDC heating and district heating controller

BM Programming Module. For the heating engineer Installation instructions

Heating Controller SDC Remote Heating Controller DHC

Boiler controller Lambdatronic S 3200

Boiler controller S-Tronic Plus

Heating and D.h.w. Controller RVL482 Basic Documentation

Condensing Boiler RS100 Controller Training Program

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

Heating Controller SDC District Heating Controller DHC 43 SERVICE MANUAL

Installation and servicing instructions

ProCon Boiler Controller Commissioning Quick Reference Guide

District heating controller

G a

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

RVL481. Heating Controller. including d.h.w. heating

District heating controller

Operating instruction. Remote control station WCM-FS /

Service Instructions for use by heating contractor

RVP310. Heating Controller. Building Technologies HVAC Products

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

Operating instructions

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions

RVP360 and RVP361 Heating controllers for 2 heating circuits and d.h.w. Basic Documentation

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

Boiler controller SPS 4000

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

- Data Brochure Universal Reset Module 423

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

PowerWizard Range. Digital Control Systems & Remote Communication Options. PowerWizard Providing Safe Control of Your.

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

Operating Instructions Heating Controllers RVL479, RVL480, RVL481, RVL482

District heating controller for two heating circuits and d.h.w. according to Siemens specifications:

Installation and Operating Manual. Merlin 5064 V3. System Manager

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

Installation and User Guide living connect Electronic Radiator Thermostat

RVL47. Heating Controller. Installations Instructions. Installation

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

Type summary Albatros 2

Installation and operating instructions

- Data Brochure Universal Reset Module 422

prestige Control Application Supplement WARNING

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

User Instructions For TopTronic RS-30

Digital Control Systems & Remote Communications Options

evotouch Controller Installation evotouch

Operating instructions THETA control unit for heating contractors. ROTEX control unit: - THETA 23R - THETA RS - THETA HEM1

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

Boiler module and operator-control unit KM 921 with CUI 9xx for heating boilers

COnDEnSInG BOIlERS TAU UNIT OIL USER parameters manual

QAW70. Room Unit. Building Technologies. for use with heating controllers

RVP340 Heating controller for 1 heating circuit RVP350 and RVP351 Heating controllers for 1 heating circuit and d.h.w. Basic Documentation

QAA Room Unit for Boiler Control with OpenTherm Interface Basic Documentation. Siemens Building Technologies Landis & Staefa Division

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

INSTRUCTION FOR THE USER THC V E OIL BLU

- Data Brochure Boiler Control 274

M116 / M450 USER AND MAINTENANCE MANUAL FOR MODULATING-CONTROL BOILER WITH GAS BURNER EQUIPPED FOR NATURAL GAS. Type : B23 ATLANTIC 2000

TIREE FAN COIL CONTROLLER - T6580

Overview - Danfoss Link and living software versions

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Control System THETA. Operating Instructions. Room control unit RSC and RSC-OT

RVL480. Heating Controller

For heating engineer/user. Operating and Installation Manual VRC 630/2. Weather compensated cascade control VRC 630

RVA Cascade Controller for modulating gas-fired Boilers Basic Documentation

PROGRAMMABLE 7-DAY THERMOSTAT

RVL470. Heating Controller. Use. Functions. Series B

RVD120, RVD140 Controllers for district heating and d.h.w. Basic Documentation

Modulating clock thermostat

AUTO CM CM USER GUIDE

Control Application. Supplement - ACVMax

District Heating Controller

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

Safety & Installation Instructions

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

Installation and Operating Manual. Merlin IO 5064 V4 with BM-T. System Manager

LYNX SE CENTRAL CONTROL FOR NETWORK GDC. General Specifications

USERS GUIDE. Electronic Timer, 7 day. LOGIC+ Combi, LOGIC Combi & LOGIC Combi E 24, 30, 35

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

heat interface units A BOILER WITHOUT A FLAME

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

Cooling kit UTW-KCL*D. Installation instructions FR NL EN DE IT. (Compatible with high-flow circulation pump, code UTW-PHF*D)

Operating Instructions

Installation & Operation Manual

Installer Manual KNX Touchscreen Thermostat

PRELIMINARY EDITION

COMFORT IP: Room Control Unit Radio with Display

LYNX CE CENTRAL CONTROL FOR OSMAC. General Specifications

Transcription:

Heating Controller SDC Remote Heating Controller DHC PARAMETER LIST EN0B-0565GE51 R0313

EN0B-0565GE51 R0313

Contents Contents 1 Software version...5 2 Access to the technician / OEM area...5 3 "Hydraulics" menu (HYDRAULIC)...6 4 "System parameters" menu (SYSTEM)...11 5 "Hot-water circuit" menu (DHW)...14 6 "Direct heating circuit" menu (UNMIXED CIRC)...18 7 "Mixed heating circuit 1 / 2" (MIX.VALVE - 1 / MIX.VALVE - 2) menus...21 8 "Heat generator" menu (HEAT GENER.)...25 9 "District hot water" menu (DIST.HEATING)...30 10 "Return increase" menu (RETURN CONTR)...32 11 "Solar" menu (SOLAR)...33 12 "Solid" menu (SOLID FUEL)...35 13 "Buffer" menu (BUFFER)...36 14 "Total flow regulation" menu (MAIN SUPPLY)...38 15 "Cascading" menu (CASCADE)...39 16 "Data bus" menu (BUS)...40 17 "Relay test" menu (RELAY TEST)...41 18 "Error messages" menu (ALARM)...42 19 "Error messages 2" menu (ALARM 2)...43 20 "Service" menu (SERVICE)...44 21 "Sensor calibration" menu (SENSOR ADJ.)...45 22 Log...46 EN0B-0565GE51 R0313 3

Contents 4 EN0B-0565GE51 R0313

Pos: 3 /156-Honeywell/Menue_Hydraulik/Menue_Hydraulik @ 0\mod_1206968369001_6.doc @ 8786 Software version Pos: 1 /156-Honeywell/Softwareversion/Softwareversion @ 0\mod_1207134342657_6.doc @ 9090 1 Software version This documentation is valid for software version V 3.2 of your control device. The software version is displayed after switch-on for approx. 8 s. If you are using an older software version, please contact your heating technician. Pos: 2 /156-Honeywell/Zugang zum Fachmann- / OEM Bereich/Zugang zum Fachmann- /OEM-Bereich @ 0\mod_1206968314048_6.doc @ 8770 2 Access to the technician / OEM area Entering a technician or OEM code enables additional options in the parameter menu. The technician code is: 1234. For access to the OEM area, please ask your field-service contact partner. Procedure: Press the and buttons simultaneously. The first number of the 4-digit code flashes. Set the first code number by turning the input button. Press the input button. The second number flashes. Enter all remaining code numbers as described in Steps 2 and 3. After entering the last code number, the controller is enabled for the respective area (technician or OEM). Press and hold the rotary button longer than 3 seconds. You reach the menu-selection level and can enter / modify parameters. Pressing the button jumps back to the previous selection. Pressing the button, pressing and holding the input button longer than 3 seconds or waiting until the set info time expires causes a jump back to the basic display. EN0B-0565GE51 R0313 5

"Hydraulics" menu (HYDRAULIC) 3 "Hydraulics" menu (HYDRAULIC) The parameters in this menu refer to the general system hydraulics and the functions and configuration of the programmable inputs and outputs for the respective system components. Representative of many individual s, the applications are only defined by the 1st parameter of this table. Example: The controller is to cover system No 0202. Provided that the controller features enough relays, parameter 01 must be set to value 0202. 01 Hydraulic schematic 02 Hot-water charging pump output 03 Mixed heating circuit 1 output 0, 0101, 0102,... n 0 No function 1 1 Hot-water charging pump 4 Circulating pump 5 Electric heating rod No function 3 2 Direct heating circuit controlled by weather conditions 3 Mixed heating circuit controlled by weather conditions 6 Constant regulator 7 Fixed-value regulator 8 Return maintenance 30 Mixed heating circuit as continuous hot-water pre-regulator (district heating) 39 Hot-water pre-regulator (district heating) 6 EN0B-0565GE51 R0313

"Hydraulics" menu (HYDRAULIC) 04 Mixed heating circuit 2 output 05 Direct heating circuit pump output For values, see parameter 03 No function 2 2 Direct heating circuit pump 4 Circulating pump 5 Electric heating element 6 Constant regulation 10 Feeder pump 11 Boiler circuit pump 1 12 Boiler circuit pump 2 13 Group alarm 14 Time switch 15 Solar charging pump 25 Cooling switchover 27 Hydraulic buffer relief 47 Electric water heater 50 Output for legionella protection 3 EN0B-0565GE51 R0313 7

"Hydraulics" menu (HYDRAULIC) 06 Variable output 1 No function 4 Circulating pump 5 Electrical heating circuit 9 Bypass pump 10 Feeder pump 11 Boiler circuit pump 1 12 Boiler circuit pump 2 13 Group error message 15 Solar charging pump 16 Buffer charging pump 17 Solid fuel charging pump 18 Stratified tank charging pump (DHC) 19 Solar charging switchover 25 Cooling switchover 26 Primary pump 27 Hydraulic buffer relief 47 Electrical water heater 50 Output for legionella protection 07 Variable output 2 For values, see parameter 06 8 EN0B-0565GE51 R0313

"Hydraulics" menu (HYDRAULIC) 08 Variable input 1 No function 1 Outside sensor 2 2 Heat generator sensor 2 3 Tank sensor 2 4 Buffer sensor 2 5 Request contact 6 External error message input 7 Return maximum limit of mixed heating circuit 1 8 Return maximum limit of mixed heating circuit 2 9 Return temperature sensor 10 External heat generator cutoff 11 External switching modem 12 External information 13 Total flow sensor 14 Collector return sensor 15 District hot-water stratified tank charge sensor 16 Exhaust gas sensor 18 Solids buffer sensor 19 Buffer sensor 1 29 Hygrostatic switch-off 30 Room sensor NTC 20 of direct heating circuit 31 Room sensor NTC 20 of mixed heating circuit 1 32 Room sensor NTC 20 of mixed heating circuit 2 EN0B-0565GE51 R0313 9

Pos: 4 /156-Honeywell/Menue_Systemparameter/Menue_Systemparameter @ 0\mod_1206968455345_6.doc @ 8802 "Hydraulics" menu (HYDRAULIC) 08 Variable input 1 50 Remote control TF22 for DK1 51 Remote control TF22 for MK1 52 Remote control TF22 for MK2 09 Variable input 2 For values, see parameter 08; does not include value 16 (exhaust gas sensor), however 10 Variable input 3 For values, see parameter 08; does not include value 16 (exhaust gas sensor), limit sensor of district heating VFB, however 11 Indirect return lifting via mixed heating circuit, ON 10 EN0B-0565GE51 R0313

"System parameters" menu (SYSTEM) 4 "System parameters" menu (SYSTEM) The parameters in this menu refer to general limit parameters and specification values in the heating system used. Time program Language selection** Operating mode Summer Language selection Time program Operating mode Summer switchoff 05 System frost protection DE GB FR IT NL ES PT HU CZ PL RO RU TR SE NO GR P1 P1 to P3 German English French Italian Dutch Spanish Portuguese Hungarian Czech Polish Romanian Russian Turkish Swedish Norwegian Greek Only one switching time program enabled Three switching time programs enabled 1 Common adjustment for all heating circuits 2 Separate adjustment for the individual heating circuits, value of parameter 05 to 30 C, 20 C to value of summer parameter DE P1 1 20 3 EN0B-0565GE51 R0313 11

"System parameters" menu (SYSTEM) 06 Request contact module for variable input 1 07 Request contact module for variable input 2 08 Request contact module for variable input 3 1 Direct heating circuit 1 2 Mixed heating circuit 1 3 Mixed heating circuit 2 4 Hot-water circuit ALL All controllers For values, see parameter 06 For values, see parameter 06 09 Climate zone 50... 0 C 12 10 Building type 1 Light construction 2 2 Medium construction 3 Heavy construction 11 Automatic exit No automatic exit 2 time 0,5... 5 min Automatic jump back to the basic display occurs after the set time 12 Anti-blocking protection 13 Logical fault messages 14 Automatic set function 15* Locking code for heating technician ON, ON, ON Anti-blocking protection active Anti-blocking protection not active 1 1 ON, 0001 to 9999 1234 16* Type code Controller type corresponding to type code table Type 12 EN0B-0565GE51 R0313

Pos: 5 /156-Honeywell/Menue_Warmwasserkreis/Menue_Warmwasserkreis @ 0\mod_1206968539157_6.doc @ 8818 "System parameters" menu (SYSTEM) 18 Cycle temperature Cycle temperature disabled enable ON Cycle temperatures enabled 19 Frost-protection mode 21* Adjustment of the real time clock (RTC) 23 Locking code for operating level 25 Cooling switchon temperature 0.5 to 60 min Continuous frost protection as per parameter 05 Cyclic operation 10... 10 s 0, 0000... 9999 2... 10 K 6 ON 28 Error memory 2, ON 29* Characteristic curve for emergency operation without outside sensor Selection of SDC / DHC reset Selection of SDC/DHC 50 to 30 C 0 SDC, DHC reset SET by pressing the input button SDC * OEM ** Other controllers also allow other language variants. EN0B-0565GE51 R0313 13

"Hot-water circuit" menu (DHW) 5 "Hot-water circuit" menu (DHW) This menu contains all parameters required to program the hot-water circuit, except the switch time programs. Hot water Legio protect ion day Hot water at night Legionella protection day 03 Legionella protection time 04 Legionella protection temperature 05 Transducer for hotwater circuit 06 Maximum temperature limit for hot water circuit 10 C to normal hot-water temperature 40 No legionella protection Mon to Sun ALL Legionella protection on specified day of week Legionella protection every day 00:00... 23:00 hours 02:00 10 C to value of parameter 06 1 Hot-water circuit temperature sensor 2 Hot-water circuit temperature controller (thermostat) 20 C to heat generator maximum temperature If parameter 07 = 7: 20 to 90 C. In automatic mode, from hotwater circuit minimum temperature. 65 1 65 14 EN0B-0565GE51 R0313

"Hot-water circuit" menu (DHW) 07 Hot-water circuit operating mode 08 Tank discharge protection 09 Temperature increase of heat generator with hotwater circuit charging 10 Switching differential of hotwater circuit 11 Hot-water charging pump follow-up time 1 Parallel operation 2 2 Priority operation 3 Conditional priority 4 Parallel operation based on weather conditions 5 Priority operation with intermediate heating 6 Priority isolating circuit 7 External operation 8 Conditional parallel operation for mixed heating circuit (DHC only) No discharge protection 5 Switching differential 5 30 K 0... 50 K Difference between hot-water circuit charging temperature and hot-water circuit setpoint temperature 2... 20 K Value of hot-water circuit switching differential. Symmetrical effect around the hot-water circuit setpoint 0... 60 min 5 15 5 EN0B-0565GE51 R0313 15

"Hot-water circuit" menu (DHW) 12 Circulation pump switching time program 13 Economy interval pause of circulating pump 14 Economy interval cycle (period duration) 15 Switching differential for storage charge 16 Circulating pump AUTO Active hot-water circuit time program 1 P1, direct heating circuit 2 P2, direct heating circuit 3 P3, direct heating circuit 4 P1, mixed heating circuit 1 5 P2, mixed heating circuit 1 6 P3, mixed heating circuit 1 7 P1, mixed heating circuit 2 8 P2, mixed heating circuit 2 9 P3, mixed heating circuit 2 10 P1, hot-water circuit 11 P2, hot-water circuit 12 P3, hot-water circuit 0... value of parameter 14 Switch-on interval while the circulating pump is running 1... 60 min 20 POS, NEG, SYM 1 Normal operation 1 2 Switched off during hotwater circuit charging AUTO 5 SYM 16 EN0B-0565GE51 R0313

Pos: 6 /156-Honeywell/Menue_Direktheizkreis/Menue_Direktheizkreis @ 0\mod_1206968634235_6.doc @ 8834 "Hot-water circuit" menu (DHW) 17 Behaviour of heat generator during follow-up time 28 29 Switch-on delay electrical water heater Offset electrical water heater AUTO Setpoint at heat generator depending on demand Heat generator off during follow-up time of solar charging pump AUTO 0 600 min 60 min 1 99 K 5 EN0B-0565GE51 R0313 17

"Direct heating circuit" menu (UNMIXED CIRC) 6 "Direct heating circuit" menu (UNMIXED CIRC) This menu contains all parameters required to program the unmixed heating circuits, except the switching time programs. Heating curve Reduced Heating system Slope, 0.02 to 3.50 1.5 Reduced operation Heating system 03 Room connection (in conjunction with room sensor) 04 Room factor ECO Switch-off operation ECO RED Lowering operation UFH Under floor heating RAD RAD CONV Radiator Convector heater Display of heat generator temperature, room sensor off, operation active 1 Display of room temperature, room sensor active, operation active 2 Display of room temperature, room sensor active, operation disabled 3 Display of room temperature, room sensor off, operation active 10... 500 % RC Influence active Room controller active 07 Heating limit, 0.5 to 40 K 08 Room frostprotection limit 09 Room thermostat function 5... 30 C 10, 0.5 to 5 K 18 EN0B-0565GE51 R0313

"Direct heating circuit" menu (UNMIXED CIRC) 10 Assignment of outside sensor 11 Constant temperature setpoint (day) 12 Minimum temperature limit 13 Maximum temperature limit 14 Temperature increase of heating circuit 15 Extended pump over-run 16 Screed function 23 Room control C-factor (SDW 30 only) 24 Room control T n (SDW 30 only) 0 Regulation to average value (outside sensor 1 + outside sensor 2) 1 Regulation to outside sensor 1 2 Regulation to outside sensor 2 10... 95 C 20 10 C to value of parameter 13 value of parameter 12 to value of parameter 30 in "Heat generator" menu (OEM maximum limit) 0 20 75 5... 20 K Direct heating circuit = 0 0... 60 min 5 1 Functional heating 2 Screed-drying heating 1... 100 8 5... 240 min 35 25 Holiday operating STBY Standby STBY mode RED Lowering operation 26 Room setpoint ramp, 0.5 to 60 K/h EN0B-0565GE51 R0313 19

Pos: 7 /156-Honeywell/Menue_Mischheizkreis_1+2/Menue_Mischheizkreis_1+2 @ 0\mod_1206968849516_6.doc @ 8850 "Direct heating circuit" menu (UNMIXED CIRC) 41 Switch-on optimisation 1 Adaption off 2 Adaption on 3 Adaption restart 42 Min. pre-heat time 0... value of parameter 43 0,5 43 Max. pre-heat time value of parameter 42 to 30 h 44 Min. jump back temperature 45 Without room sensor 46 Pre-heat time at 0 C 0... 30 C 5 0... 10 C 1 0... 30 h 1 47 Lowering ramp 0... 500 % 100 Heating circuit name Heating circuit name 48 Constant temperature setpoint (night) 00000... ZZZZZ 10... 95 C (only for reduced operation = RED) 5 20 20 EN0B-0565GE51 R0313

"Mixed heating circuit 1 / 2" (MIX.VALVE - 1 / MIX.VALVE - 2) menus 7 "Mixed heating circuit 1 / 2" (MIX.VALVE - 1 / MIX.VALVE - 2) menus These menus contain all parameters required to program the mixed heating circuit, except the switching time programs. Heating curve Reduced Heating system Slope, 0.02 to 3.50 1 Reduced operation Heating system ECO Switch-off operation ECO RED UFH RAD CONV Lowering operation Floor heating Radiator Convector heater 03 Room connection (in conjunction with room sensor) Display of heat generator temperature, room sensor off, operation active 04 Room factor 1 Display of room temperature, room sensor active, operation active 2 Display of room temperature, room sensor active, operation disabled 3 Display of room temperature, room sensor off, operation active 10... 500 % RC Influence active Room controller active RAD 07 Heating limit, 0.5 to 40 K EN0B-0565GE51 R0313 21

"Mixed heating circuit 1 / 2" (MIX.VALVE - 1 / MIX.VALVE - 2) menus 08 Room frostprotection limit 09 Room thermostat function 10 Assignment of outside sensor 11 Constant temperature setpoint (only if output was set to constant regulator) 12 Minimum temperature limit 13 Maximum temperature limit 14 Temperature increase of heating circuit 15 Follow-up time of pump 16 Screed function 17 Return maximum temperature limit 5... 30 C 10, 0.5 to 5 K 0 Regulation to average value (outside sensor 1 + outside sensor 2) 1 Regulation to outside sensor 1 2 Regulation to outside sensor 2 10... 95 C 20 10 C to value of parameter 13 value of parameter 12 to value of parameter 30 in "Heat generator" menu (OEM maximum limit) 0 20 75 5... 20 K Mixed heating circuit = 4 0... 60 min 5 1 Functional heating 2 Screed-drying heating 10... 90 C 90 18 P part X P 1... 50 %/K 2 19* Sampling time T s 1... 600 s 20 20 I part T n 1... 600 s 270 22 EN0B-0565GE51 R0313

"Mixed heating circuit 1 / 2" (MIX.VALVE - 1 / MIX.VALVE - 2) menus 21 Actuator runtime 10... 600 s 120 22* Actuator end position function 23 Room control C- factor (SDW 30 only) 24 Room control T n (SDW 30 only) 1 Continuous control signal in end position 2 Control signal suppressed at end position (actuator deenergised) 1... 100 8 5... 240 min 35 25 Holiday operating STBY Standby STBY mode RED Lowering operation 1 26 Room setpoint ramp 28 Cooling temperature of mixed heating circuit 39 Spread of hotwater circuit preregulator 40 Offset valve position of hotwater circuit preregulator 41 Switch-on optimisation 42 Minimum pre-heat time, 0.5... 60 K/h, 5 24 2... 20 K 5 0... 100 % 0 1 Adaptation off 2 Adaptation on 3 Adaptation restart 0... value of parameter 43 0.5 EN0B-0565GE51 R0313 23

Pos: 8 /156-Honeywell/Menue_Waermeerzeuger/Menue_Waermeerzeuger @ 0\mod_1206968927001_6.doc @ 8866 "Mixed heating circuit 1 / 2" (MIX.VALVE - 1 / MIX.VALVE - 2) menus 43 Maximum pre-heat time 44 Min. jump back temperature 45 Without room sensor 46 Pre-heat time at 0 C value of parameter 42 to 30 h 0... 30 C 5 0... 10 C 1 0... 30 h 1 47 Lowering ramp 0... 500 % 100 Heating circuit name Heating circuit name 48 Constant temperature setpoint (night) 00000... ZZZZZ 10... 95 C (only for reduced operation = RED) 5 20 * OEM 24 EN0B-0565GE51 R0313

"Heat generator" menu (HEAT GENER.) 8 "Heat generator" menu (HEAT GENER.) The parameters in this menu refer to the type of the respective heat generator and the associated specific control functions. 01 Design 02 Start-up protection (not if parameter 01 = ) 03 Minimum temperature limit (not if parameter 01 = ) 04 Maximal temperature limit (not if parameter 01 = ) 06 Sensor operating mode 07 Minimum burner runtime Without heat generator 1 1 Oil/gas - one stage 2 Oil/gas - two stages 3 Oil/gas - 2 x one stage 4 Modulating burner 5 Open Therm No start-up protection 1 1 Unlimited start-up protection 2 Start-up protection controlled by weather conditions 3 Start-up protection disconnected 5 C to value of parameter 04 value of parameter 03 to value of parameter 30 (OEM maximum limit) 1 Burner switch-off in case of defect 2 External burner switchoff 3 Burner enable in case of defect 0... 20 min 2 38 (5 with automatic operation) 80 1 EN0B-0565GE51 R0313 25

"Heat generator" menu (HEAT GENER.) 08 Burner switching differential I 09 Burner switching differential II (not if parameter 01 = 2) 10 Connection delay stage II 11 Boiler start-up relief stage II 13 Lead time of boiler circuit pump or parallel heat generator enable (only with appropriate configuration in the "Hydraulics" menu) 14 Follow-up time of boiler circuit pump (only with appropriate configuration in the "Hydraulics" menu) 15 Follow-up time of feeder pump (only with appropriate configuration in the "Hydraulics" menu) One stage: 2... 30 K 6 Two stages: 2... ( value of parameter 09 0.5 K) ( value of parameter 08 + 0.5) to 30 K 0... 60 min (0 = 10 s) 0 1 Unlimited enable during start-up relief 2 Time-out during start-up relief 0... 10 min 0 0... 60 min 2 0... 60 min 2 8 2 26 EN0B-0565GE51 R0313

"Heat generator" menu (HEAT GENER.) 16 Exhaust gas temperature monitoring (only with appropriate configuration in the "Hydraulics" menu) 17 Exhaust gas limit value (only with appropriate configuration in the "Hydraulics" menu) 19 Modulation of proportional range X P 20 Modulation of sampling time T s 21 Modulation of adjustment time T n 22 Modulation of runtime 23 Modulation of start time 24 Modulation of start power 25 Outside temperature lock (not if parameter 01 = ) 26 Base load increase 27 Minimum temperature limit of heating circuits (only if parameter 02 = 3) 0... 60 min SLT Display of exhaust gas temperature only Heat generator lock if limit value is exceeded for set time Heat generator lock if limit value is exceeded 50... 500 C 200 0.1... 50 %/K 5 1... 600 s 20 1... 600 s 180 5... 600 s 12 0... 900 s 60 0... 100 % 70, 20 to +30 C 0... 60 K 30 5 C to value of parameter 03 36 EN0B-0565GE51 R0313 27

"Heat generator" menu (HEAT GENER.) 28 Switching differential of minimum temperature limit of heating circuits (only if parameter 02 = 3) 29 Heat generator forced discharge 30* OEM maximum limit 31* Full-load regulation 34 Power limit for heating 35 Power limit for hot water 37 Burner counter mode (counter of operating hours) 38 Outside temperature lock, inverse 39 Fixed delay (cascade) 2... 20 K 4 1 Discharge to process water tank 2 Discharge to heating circuits 3 Discharge to buffer tank value of parameter 03 to 130 C, 0.5 to 10 110 50... 100 % 100 50... 100 % 100 AUTO 1 Feedback only 2 Free counter, 20 to +30 C, 1 300 min AUTO 28 EN0B-0565GE51 R0313

Pos: 9 /156-Honeywell/Menue_Fernwaerme/Menue_Fernwaerme @ 0\mod_1206969020110_6.doc @ 8882 "Heat generator" menu (HEAT GENER.) RESET ST-1 RESET ST-2 Re of burner start counter and operating hours of stage 1 (not if parameter 01 = ) Re of burner start counter and operating hours of stage 2 (not if parameter 01 = 2 or 01 = ) * OEM SET by pressing the input button SET by pressing the input button EN0B-0565GE51 R0313 29

"District hot water" menu (DIST.HEATING) 9 "District hot water" menu (DIST.HEATING) The parameters in this menu refer to the type of the respective district hot-water station and the associated specific control functions. 01 Increase, 10 to 50 K 0 02 Maximum limit of flow temperature setpoint 03* Minimum district heating valve stroke 04 Secondary flow boost 10... 130 C 90 0... 50 % 10 0,1... 30 %/K 5 05 Adjustment time 0... 60 min 3 06 Runtime of district heating valve 1 07* Runtime of district heating valve 2 08* Maximum return temperature setpoint 09* Application point variable district heating return temperature 10* Maximum return temperature setpoint with hot water circuit charge 10... 1800 s 120 10... 1800 s 30 0... 100 C 90, 20 to 10 C 0... 100 C 90 30 EN0B-0565GE51 R0313

Pos: 10 /156-Honeywell/Menue_Ruecklaufanhebung/Menue_Ruecklaufanhebung @ 0\mod_1206969068626_6.doc @ 8898 "District hot water" menu (DIST.HEATING) 11* Return limit of district heating valve 12* Calibration of heat output 13* Calibration of volume flow 14* Maximum heat output 15* Maximum volume flow 16 Increase in return temperature at legionella function 0 Temperature (parameters 12 through 15 are not displayed) 1 Volume flow and temperature (parameters 12 through 14 are not displayed) 2 Heat output and temperature (parameters 13 through 15 are not displayed) 1... 9999 1 1... 9999 1 1... 9999 kw 9999 0,01... 99.99 m 3 /h 99.99, 0,5... 20 K 0 * OEM EN0B-0565GE51 R0313 31

Pos: 11 /156-Honeywell/Menue_Solar/Menue_Solar @ 0\mod_1206969135766_6.doc @ 8914 "Return increase" menu (RETURN CONTR) 10 "Return increase" menu (RETURN CONTR) The parameters in this menu refer to special s with regard to the increase in return temperature with heat generators. Enabling occurs only with corresponding activation in the "Hydraulics" menu. 01 Return temperature setpoint 02 Switch-off differential 03 Follow-up time of pump 10... 95 C 20 1... 20 K 2 0... 60 min 1 32 EN0B-0565GE51 R0313

"Solar" menu (SOLAR) 11 "Solar" menu (SOLAR) The parameters in this menu refer to special s with regard to the solar applications. Enabling occurs only with corresponding activation in the "Hydraulics" menu. 01 Switch-on differential 02 Switch-off differential 03 Minimum runtime of solar charging pump 05 Buffer maximum temperature limit 06 Operating mode 07 Heat generator cycle inhibitor (only if parameter 06 = 1) 08 Solar priority parallel switchover 09 Heat balance 10 Reset heat balance ( value of parameter 02 + 3 K) to 30 K 2 K to ( value of parameter 01 3 K) 0... 60 min 3 10 20... 110 C 75 1 Priority operation 2 Parallel operation 3 Priority operation of hotwater circuit 4 Priority operation of buffer, 0.5 to 24 h, 1 to 30 K No heat balancing 1 Heat balancing via flowthrough calculation 2 Heat balancing via pulse input SET by pressing the input button 5 2 EN0B-0565GE51 R0313 33

Pos: 12 /156-Honeywell/Menue_Feststoff/Menue_Feststoff @ 0\mod_1206969179876_6.doc @ 8930 "Solar" menu (SOLAR) 11 Volume flow 0... 30 L/min or L/pulse 0 12 Density of medium 0.8... 1.2 kg/l 1.05 13 Heat capacity of medium 14 Final switch-off temperature 15 Test cycle of solar charging switchover 16 Switchover temperature 2... 5 KJ/kgK 3.6, 90 to 210 C 210 1... 60 min 10 20... 110 C 75 34 EN0B-0565GE51 R0313

Pos: 13 /156-Honeywell/Menue_Puffer/Menue_Puffer @ 0\mod_1206969217376_6.doc @ 8946 "Solid" menu (SOLID FUEL) 12 "Solid" menu (SOLID FUEL) The parameters in this menu refer to special s with regard to solids regulation. Enabling occurs only with corresponding activation in the "Hydraulics" menu. 01 Minimum temperature 02 Maximum temperature 03 Switch-on differential 04 Switch-off differential 05 Heat generator cycle inhibitor 20... 80 C 60 30... 100 C 90 ( value of parameter 04 + 3 K) to 20 K 2 K to ( value of parameter 03 3 K), 2 to 180 min 10 5 EN0B-0565GE51 R0313 35

"Buffer" menu (BUFFER) 13 "Buffer" menu (BUFFER) The parameters in this menu refer to special s with regard to solids regulation. Enabling occurs only with corresponding activation in the "Hydraulics" menu. 01 Minimum temperature 02 Maximum temperature 03 Boiler temperature increase 04 Buffer switching differential 5 C to value of parameter 02 value of parameter 01 to 95 C 10 to 80 K 0 1 to 70 K 2 05 Forced discharge 06 Follow-up switchon differential 07 Follow-up switchoff differential 1 In process water tank 2 In heating circuits, ( value of parameter 07 + 2 K) to 50 K 1 K to ( value of parameter 06 2 K) 08 Buffer start-up No start-up protection ON protection ON Discharge protection active 09 Buffer discharge protection No discharge protection 5 Switching differential 5... 20 K 20 80 10 5 36 EN0B-0565GE51 R0313

Pos: 14 /156-Honeywell/Menue_Summenvorlaufregelung/Menue_Summenvorlaufregelung @ 0\mod_1206969262720_6.doc @ 8962 "Buffer" menu (BUFFER) 10 Buffer operating mode 11 Follow-up time of buffer charging pump 1 Heating circuit charge regulation and hot-water circuit 2 Heating circuit charge regulation without hotwater circuit 3 Heating circuit and hotwater circuit discharge regulation 4 Heating circuit discharge regulation without hotwater circuit 5 Charge regulation with hot-water circuit switchover 6 Discharge regulation for heat generator 0... 60 min 3 1 EN0B-0565GE51 R0313 37

Pos: 15 /156-Honeywell/Menue_Kaskadierung/Menue_Kaskadierung @ 0\mod_1206969304407_6.doc @ 8978 "Total flow regulation" menu (MAIN SUPPLY) 14 "Total flow regulation" menu (MAIN SUPPLY) The parameters in this module refer to special s with regard to total flow regulation. This selection is only available if a total flow sensor is configured on one of the variable inputs (see the "Hydraulics" menu, parameters 08, 09 or 10). 01 Regulation 0... 50 %/K 5 03 Regulation 1... 600 s 180 38 EN0B-0565GE51 R0313

Pos: 16 /156-Honeywell/Menue_Datenbus/Menue_Datenbus @ 0\mod_1206969341954_6.doc @ 8994 "Cascading" menu (CASCADE) 15 "Cascading" menu (CASCADE) The parameters in this menu refer solely to the parameters that are associated with the cascading of multiple heat generators. This selection is only available if multiple heat generators exist in the control system. 01 Switching differential 0.5... 30 K 4 02 Connection delay 0... 200 min 0 03 Switch-off delay 0... 60 min 0 04 Switchover power of stage sequence 10... 100 % 65 05 Stage reversal, 1 to 250 h 06 Guidance stage 1... maximum number of stages 1 07 Peak-load stage, 2... maximum number of stages All heat generators are numbered consecutively within the cascade. The total quantity determines the maximum number of stages. 08 Switchover of base load with grouping 09* Quick hot-water connection, ON, 1... maximum number of stages * OEM EN0B-0565GE51 R0313 39

Pos: 17 /156-Honeywell/Menue_Relaistest/Menue_Relaistest @ 0\mod_1206969390188_6.doc @ 9010 "Data bus" menu (BUS) 16 "Data bus" menu (BUS) The parameters in this menu refer solely to the parameters that are associated with the data bus. 01 Central device address 10, 20, 30, 40, 50 10 02 Bus authorisation SDW 30 of direct heating circuit 1 2 Expanded access authorisation Simple access authorisation 03 Bus authorisation SDW 30 of mixed heating circuit 1 1 2 Expanded access authorisation Simple access authorisation 04 Bus authorisation SDW 30 of mixed heating circuit 2 1 2 Expanded access authorisation Simple access authorisation 05 Cascading operation, ON 1 1 1 ON 40 EN0B-0565GE51 R0313

Pos: 18 /156-Honeywell/Menue_Stoermeldungen/Menue_Stoermeldungen1 @ 0\mod_1206969445079_6.doc @ 9026 "Relay test" menu (RELAY TEST) 17 "Relay test" menu (RELAY TEST) In this menu, the relays contained within the central device can be selected via the input button and checked for operation. 01 Heat generator test Different relay switching sequence depending on the set heat generator 02 Direct heating circuit pump test 03 Mixed heating circuit pump 1 test -ON- -ON- 04 Mixer motor 1 test STOP-OPEN-CLOS STOP 05 Mixed heating circuit pump 2 test -ON- 06 Mixer motor 2 test STOP-OPEN-CLOS STOP 07 Storage charging pump test 08 Variable output 1 test 09 Variable output 2 test -ON- -ON- -ON- 10 System Display of sensor value by pressing the input button EN0B-0565GE51 R0313 41

Pos: 19 /156-Honeywell/Menue_Stoermeldungen/Menue_Stoermeldungen2 @ 0\mod_1206969471860_6.doc @ 9041 "Error messages" menu (ALARM) 18 "Error messages" menu (ALARM) Error messages that occur are displayed in this menu. The fault memory can hold max. 20 messages, which can be displayed individually. 01 Error message 1 Last error message "Display" 02 Error message 2 Last error message but one "Display" 03 Error message 3 Last error message but two "Display" 04 Error message 4 Last error message but three "Display" 05 Error message 5 Last error message but four "Display"... 20 Error message 20 First error message "Display" 21* Reset error messages SET by pressing the input button * OEM 42 EN0B-0565GE51 R0313

"Error messages 2" menu (ALARM 2) 19 "Error messages 2" menu (ALARM 2) Only in conjunction with heat generator interface Error messages triggered by an automatic stoker are displayed in this menu. The fault memory can hold max. 20 messages, which can be displayed individually. For this purpose, parameter 28 in the "System parameters" menu must be set to ON. 01 Error message 1 Last error message "Display" 02 Error message 2 Last error message but one "Display" 03 Error message 3 Last error message but two "Display" 04 Error message 4 Last error message but three "Display"... 20 Error message 20 First error message "Display" 21* Reset error messages SET by pressing the input button * OEM EN0B-0565GE51 R0313 43

Pos: 20 /156-Honeywell/Menue_Fuehlerabgleich/Menue_Fuehlerabgleich @ 0\mod_1206969622157_6.doc @ 9057 "Service" menu (SERVICE) 20 "Service" menu (SERVICE) 01 Outside temperature specification, 50... 30 C 44 EN0B-0565GE51 R0313

Pos: 21 /156-Honeywell/Protokoll/Protokoll @ 0\mod_1206969686157_6.doc @ 9072 "Sensor calibration" menu (SENSOR ADJ.) 21 "Sensor calibration" menu (SENSOR ADJ.) In this menu, all sensors connected to the central device can be corrected by ±5 K based on the factory calibration value. 01 Outside sensor 5... +5 K 0 02 Heat generator sensor 5... +5 K 0 03 Hot-water sensor 5... +5 K 0 04 Flow sensor of mixed heating circuit 1 05 Flow sensor of mixed heating circuit 2 06 Collector flow sensor 07 Buffer sensor of collector 08 Sensor of variable input 1 09 Sensor of variable input 2 10 Sensor of variable input 3 11 Room sensor SDW 10 of direct heating circuit 12 Room sensor SDW 10 of mixed heating circuit 1 13 Room sensor SDW 10 of mixed heating circuit 2 5... +5 K 0 5... +5 K 0 5... +5 K 0 5... +5 K 0 5... +5 K 0 5... +5 K 0 5... +5 K 0 5... +5 K 0 5... +5 K 0 5... +5 K 0 EN0B-0565GE51 R0313 45

===== Ende der Stückliste ===== Log 22 Log Weekly switching program Object: Set by: On: Mon (1) Tue (2) Wed (3) Thu (4) Fri (5) Sat (6) Sun (7) Cont. circuit Time Setpoint Opt. Cont. circuit Time Setpoint Opt. Cont. circuit Time Setpoint Opt. Cont. circuit Time Setpoint Opt. Cont. circuit Time Setpoint Opt. Cont. circuit Time Setpoint Opt. Cont. circuit Time Setpoint Opt. 46 EN0B-0565GE51 R0313

Log EN0B-0565GE51 R0313 47

Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z.A. La Pièce 16, Switzerland by its Authorized Representative: Automation and Control Solutions Honeywell House Arlington Business Park Bracknell, Berks, RG12 1EB Phone (44) 1344 656000 Fax (44) 1344 656644 http://honeywell.com/uk Printed in Germany All rights reserved. Subject to change without notice. EN0B-0565GE51 R0313 Art. 045 930 5521 1311 32