Microfast quick response Fusible element hsw sprinkler

Similar documents
TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

standard response fusible link sidewall sprinkler VK112 (K5.6)

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

standard response Fusible Link Upright sprinkler VK204 (K8.0)

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

MICROFAST SR/QR EXTENDED COVERAGE HSW SPRINKLER VK605 (K5.6) TECHNICAL DATA

micromatic Standard response Horizontal Sidewall sprinkler

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

TECHNICAL DATA. Page 1 of 6

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

microfast sr/qr extended coverage pendent sprinkler

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

quick response horizontal sidewall sprinkler vk360 (K8.0)

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

microfast quick response extended coverage hsw sprinkler vk606

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

microfast quick response Pendent sprinkler VK302 (K5.6)

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

micromatic standard response Upright sprinkler VK100 (K5.6)

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

STANDARD/quick. Sprinkler 42o. August 8, 2011

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK120 (K8.0) TECHNICAL DATA

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

standard response elo upright sprinkler

standard response elo upright and pendent sprinklers (storage-density/area)

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

standard response dry horizontal sidewall sprinklers

standard/quick response extended coverage light and ordinary hazard elo sprinklers

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

standard response dry horizontal sidewall sprinklers

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

quick response Sprinkler 105a October 25, 2010

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

micromatic standard response stainless steel sprinklers

standard response/ quick response extended coverage

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

standard response dry horizontal sidewall sprinklers

standard response large orifice dry

microfast and microfasthp quick conventional sprinklers

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

freedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)

TECHNICAL DATA. Page 1 of 5

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

Standard Spray concealed horizontal sidewall sprinkler VK481

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK534 (K11.2)

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK460 (K5.8) TECHNICAL DATA

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

DRY VERTICAL SIDEWALL SPRINKLERS TECHNICAL DATA

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.

Quick response concealed horizontal sidewall sprinkler VK481

freedom residential pendent sprinkler vk466 (K5.2)

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

TECHNICAL DATA vk470 (K3.0)

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

Standard response. elo sprinklers

mirage standard response concealed pendent sprinkler vk492 (K5.6)

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

Transcription:

Page 1 of 7 TECHNICAL DATA 1. DESCRIPTION The Viking Microfast Quick Response Fusible Element Horizontal Sidewall Sprinkler VK307 is a small thermosensitive solder link spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Polytetrafluoroethylene (PTFE) coatings can be used in decorative applications where colors are desired. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2020 Refer to Approval Chart 1 and Design Criteria for culus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar) Deflector (Sprinkler 13949): U.S.A. Patent No. 4,296,816 Thread Size: 1/2 (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metric*) *Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Overall Length: Refer to the Approval Charts Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Copper UNS-C19500 Fusible Element Assembly: Nickel Alloy Trigger and Support: Stainless Steel UNS-S31600 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Seat and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Screw: Brass UNS-C36000 For PTFE Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Horizontal Sidewall Fusible Element Sprinkler VK307 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and Black PTFE = N Temperature Suffix: 165 F / 74 C = C, 205 F / 96 C = E, and 280 F / 138 C = G For example, sprinkler VK307 with a Brass finish and a 165 F / 74 C temperature rating = Part No. 13947AC Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: A. Standard Wrench: Part No. 21475M/B (available since 2017). B. Wrench for recessed sprinklers with protective shields: Part No. 13655W/B** (available since 2003) **A ½ ratchet is required (not available from Viking). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) Replaces Form No. F_062714 Rev 14.2 (Replaced wrench 10896W/B with 21475M/B)

Page 2 of 7 4. Installation Refer to appropriate NFPA Installation Standards. 5. Operation During fire conditions, the heat-sensitive fusible element assembly disengages, releasing the seat and spring assemblies to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availability Viking Quick Response Horizontal Sidewall Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. Guarantee For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Wrench Flat Figure 1: Standard Sprinkler Wrench 21475M/B

Page 3 of 7 Sprinkler Temperature Classification TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Nominal Temperature Rating 1 Ambient Ceiling Temperature 2 Frame Paint Color Ordinary 165 F (74 C) 100 F (38 C) None Intermediate 205 F (96 C) 150 F (65 C) White High 280 F (138 C) 225 F (107 C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester 3, Black Polyester 3, and Black PTFE 3 Footnotes 1 Decorative sprinklers may not be color coded. The temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and PTFE coatings. For PTFE coated open sprinklers only, the waterway is coated. Step 1: Carefully slide the wrench sideways around the deflector, ensuring engagement with the sprinkler wrench flats. Sprinkler wrench 13655W/B** must be used for installing wax coated sprinklers. ** A 1/2 ratchet is required (not available from Viking) Step 2: Carefully press the wrench onto the sprinkler wrench flats. Figure 2: Wrench 13655W/B for Recessed Sprinklers

Base Part Number 1 TECHNICAL DATA Page 4 of 7 SIN Pressure Approval Chart 1 (UL) Quick Response Fusible Element Horizontal Sidewall Sprinkler VK307 175 PSI WWP For Light Hazard Occupancies Only. Thread Size Nominal K-Factor Overall Length Listings and Approvals 3 (Refer also to Design Criteria below.) NPT BSP U.S. metric 2 Inches mm culus 4 LPCB Deflectors must be located 4 to 6 (102 mm to 152 mm) below the ceiling. 13947 VK307 175 psi 1/2 15 mm 5.6 80.6 2-1/2 64 A1Y, B1X -- -- -- Deflectors must be located 6 to 12 (152 mm to 305 mm) below the ceiling. 13947 VK307 175 psi 1/2 15 mm 5.6 80.6 2-1/2 64 A1Y -- -- -- NOTICE - Product Below - Limited Availability (Contact Local Viking Office) Deflectors must be located 4 to 6 (102 mm to 152 mm) below the ceiling. 13948 VK307 175 psi 1/2 15 mm 5.6 80.6 2-1/2 64 A1Y, B1X -- -- -- Deflectors must be located 6 to 12 (152 mm to 305 mm) below the ceiling. 13948 VK307 175 psi 1/2 15 mm 5.6 80.6 2-1/2 64 A1Y -- -- -- Approved Temperature Ratings A - 165 F (74 C), 205 F (96 C), 280 F (138 C) B - 165 F (74 C) and 205 F (96 C) Approved Finishes 1 - Brass, Chrome, White Polyester 5, Black Polyester 5, and Black PTFE Approved Escutcheons X - Installed with standard surface-mounted escutcheons or the Viking Microfast Model F-1 Adjustable Escutcheon, or recessed with the Viking Micromatic Model E-1 or E-2 Y - Installed with standard surface-mounted escutcheons or the Viking Microfast Model F-1 Adjustable Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 Other colors are available on request with the same Listings and Approvals as the standard colors. culus Listing Requirements: DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) Quick Response Horizontal Sprinkler VK307 is culus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. Sprinkler VK307 is limited to Light Hazard occupancies only. Locate Sprinkler VK307 with the deflector 6 to 12 (152 mm to 305 mm) below the ceiling. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Minimum spacing allowed is 6 ft. (1.8 m). Align the top of the deflector parallel with the ceiling. Locate no less than 4 (102 mm) from end walls. distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.

Page 5 of 7 Approval Chart 2 (FM) Quick Response Fusible Element Horizontal Sidewall Sprinkler VK307 175 PSI WWP Base Part Number 1 SIN Pressure Thread Size Nominal K-Factor Overall Length FM Approvals 3 NPT BSP U.S. metric 2 Inches mm (Refer also to Design Criteria below.) 13947 VK307 175 psi 1/2 15 mm 5.6 80.6 2-1/2 64 A1Y, B1X NOTICE - Product Below - Limited Availability (Contact Local Viking Office) 13948 VK307 175 psi 1/2 15 mm 5.6 80.6 2-1/2 64 A1Y, B1X Approved Temperature Ratings A - 165 F (74 C), 205 F (96 C), 280 F (138 C) B - 165 F (74 C) and 205 F (96 C) Approved Finishes 1 - Brass and Chrome Approved Escutcheons X - Installed with standard surface-mounted escutcheons or the Viking Microfast Model F-1 Adjustable Escutcheon, or recessed with the Viking Micromatic Model E-1 or E-2 Recessed Escutcheons, or G-1 Y - Installed with standard surface-mounted escutcheons or the Viking Microfast Model F-1 Adjustable Escutcheon, or G-1 Footnotes 1 Base part number shown. For complete part number, refer to Viking s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing. Other approvals may be in process. FM Approval Requirements: DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) Horizontal Sidewall Sprinkler VK307 is FM Approved as quick response Non-storage sidewall sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from culus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.

Page 6 of 7 2-9/16 (64 mm) 2-7/16 (62 mm) Minimum 2-1/16 (52 mm) 2-1/8 (54 mm) 2-5/8 (67 mm) Wall Opening Size: 2-5/16 (59 mm) minimum 2-1/2 (64 mm) maximum Installed with a Standard 1/8 Surface-Mounted Escutcheon Installed with a Microfast Model F-1 Adjustable Escutcheon Figure 3: Sidewall Sprinkler Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Minimum 1-5/8 (41 mm) Minimum 1-3/4 (45 mm) 2-1/8 (54 mm) 2-1/8 (54 mm) 2-1/4 (57 mm) 2-5/8 (67 mm) Wall Opening Size: 2-5/16 (59 mm) minimum 2-1/2 (64 mm) maximum Installed with the Micromatic Model E-1 Installed with the Threaded Model E-2 Figure 4: Sidewall Sprinkler Dimensions with the Model E-1 and E-2 s

Page 7 of 7 Adjustable Adapter Ring Adjustable Outer Cup 1/8 (3 mm) Wall opening size with the Model G-1 Escutcheon: 2-5/8 (66 mm) minimum 3-3/4 (95 mm) maximum 2-5/8 (66 mm) 4 (102 mm) Depth 1-1/16 (27 mm) 1-1/16 (27 mm) Recess: 1/2 (13 mm) ** A 1/2 ratchet is required (not available from Viking) Step 2: Carefully press the wrench onto the sprinkler wrench flats. Figure 5: Sidewall Sprinkler Dimensions with the Model G-1 Escutcheon Replaces Form No. F_062714 Rev 14.2 (Replaced wrench 10896W/B with 21475M/B)