Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Similar documents
Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

PF Series. Piston Actuated Valves

APT and APT14 Automatic Pump Traps. for effective condensate drainage and removal

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

Hoffman Specialty General Catalog

Liquid Drainers LIQUID DRAINERS

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

THERMOSTATIC STEAM TRAPS

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

Silhouette. Feedwater Heater. Boiler Feedwater

Our Know-How. Your Peace of Mind. Steam Solutions

Steam trapping overview STEAM & CONDENSATE MANAGEMENT SOLUTIONS

Pump & Trap Combinations

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

MFP14 Automatic pumps. for condensate and other industrial fluids

A complete, compact steam heat exchange solution for process and domestic water heating requirements.

Ball Float Steam Trap with Integral Spiratec Sensor and Flanged Connections

Pamphlet A2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

THE THERMOSTATIC STEAM TRAP

MFP14 Automatic pumps for condensate and other industrial fluids

LIQUIDATOR UMT-TD Series Thermodynamic

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

STEAM TRAPS

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Inverted Bucket Steam Traps

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Pamphlet U2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

FT14 Ball Float Steam Trap (Screwed)

Economical and simplified solutions that offer quality and optimum steam trap service.

Technical Data CONDENSATE COMMANDER PUMP SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 9902D

THERMODYNAMIC STEAM TRAPS

THERMODYNAMIC STEAM TRAPS

LIQUIDATOR 450 SERIES

Pamphlet M2404. Mechanical Pump & Pump/ Trap. GP Series GT Series

UNIVERSAL STYLE STEAM TRAPS WU450 Series

Pure Performance For Steam Mains and Tracers

Steam Traps and Steam Specialties

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

FT14 and FT14HC. SG Iron Ball Float Steam Traps (1" HC, 1¼", 1½" and 2")

Removal of Non-condensable Gases and Air Is Critical In A Steam System

GESTRA Information A 1.5

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

HEAT EXCHANGER FORMULAS & EXAMPLE

PIP PNE00004 Steam Trap Guidelines

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

VIFB Coil Technical Guide

TL\l DRAIN TRAP. , s. JA JAHR Series I GS. TATSU2 SS1VA/JAHRASeries. Pamphlet A

spiraxsarco.com/global/us Product Overview A quick guide to products for steam and related industrial fluids

5. CONDENSATE PUMPS/UNITS

PRESSURE MOTIVE PUMP (PMP) APPLICATIONS

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

The right trap for the right application.

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

Spirax-Sarco Industrial Thermostatic Steam Traps

Series 1140 and 1141 Temperature Regulators

High Purity Systems and Products. for the biopharmaceutical industry

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

Installation and Testing of Inverted Bucket Steam Traps Manual

205 Control Installation and Maintenance Instructions

TESTING STEAM TRAPS TO KEEP YOUR SYSTEM OPERATING EFFECTIVELY AND EFFICIENTLY

CD-33/CD-33S Controlled Disc Steam Traps

VIFB Coil Technical Guide

Inverted Bucket Float & Thermostatic Radiator Traps STEAM CONTROL PRODUCTS STEAM TRAPS

Disc Type Steam Trap TSD-42

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

THE PIVOTROL PUMP (Patented) Featuring Reliable PowerPivot Technology

Moss MOSS TRAY DEAERATOR ECONOMICAL INDUSTRIAL DEAERATOR SYSTEMS

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

Industrial Processing Solutions

STAINLESS STEEL TRAP VALVE STATION

Intelligent System Solutions Steam Air Hot Water

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

INSTALLATION AND MAINTENANCE INSTRUCTIONS. IM US March RediHeat. Table Of Contents. I. Installation RediHeat Start-Up Procedure 4

Air Vents for Hot and Chilled Water Systems

Steam System Best Practices Document No. 11

"SXDDR" Series Steam Heat Exchanger Humidifiers

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

Pamphlet M JA3D / JA Series / G8 AIR & DRAIN TRAPS. TATSU2 SS1VG / JAHSeries

Packaged Semi-Instantaneous Steam Fired Water Heater

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Refrigerant Valves/Accessories

STEAM AND TRAP FUNDAMENTALS

Steam Site Guide. Steam Site Guide. Heat Exchange Applications - SI Units

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV

WATER HAMMER something that never should occur in a steam system

Installation and Maintenance "L" and "LS" Series

Pamphlet A2000. TL\l. Free Float Steam Trap Series

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Pure Performance For Steam Mains and Tracers

UNIFIED FACILITIES GUIDE SPECIFICATIONS

.03 ATMOSPHERIC DEAERATOR

Pumps. Pressured-powered pump catalog. The more reliable and efficient way to pump condensate and other liquids.

Transcription:

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Float & Thermostatic Steam Traps from Spirax Sarco About float & thermostatic steam traps Most steam-using equipment is designed to utilize the heat given up by steam when it condenses. For efficient operation, the steam space must be kept free of condensate and air so that the entire heat transfer surface is exposed to steam. Only a Float & Thermostatic steam trap can drain condensate as quickly as it forms while at the same time removing air and other non-condensible gases which may be present at start-up or collect during operation. Condensate never backs up into the steam space; gases collect in the top of the trap and are removed through a separate integral air vent. Spirax Sarco offers the world s most complete line of Float & Thermostatic steam traps with cast iron, ductile iron, carbon steel and stainless steel bodies for steam pressures up to 465 psi and condensate loads up to 300,000 lb/h. User benefits Instantly adjusts to load and pressure variations. Automatic air venting reduces warm-up time and improves heat transfer. Continuously modulated discharge eliminates steam space pressure variations for closer temperature control. Stainless steel valve trim, floats and air vents increase service life. piping connections simplify installation and maintenance. All internal parts can easily be renewed without disturbing the pipe connections. Float & Thermostatic traps can never lose prime and blow steam. When condensate is not present, the main valve closes tight. Steam loss is eliminated because during operation, the main valve is always sealed by condensate. The optional SLR prevents steam locking when condensate must be lifted to the trap. (available on limited models) Option Vacuum breaker built into trap to break vacuum on system shutdown. (available on limited models) 2

Key features and benefits Key features Key reasons Key benefits float Rugged, corrosion resistant, shock and surge resistant. Automatically adjusts the valve opening to maintain a continuous condensate flow. Low lifetime failure rate. Unaffected by back pressure Trap only requires differential pressure to operate. Infi nite turn down on both pressure and fl ow. Operation is regulated solely by condensate level inside the trap, which allows the trap to drain process equipment effectively under varying demands. Easy to service Trap has either bolted cover or universal connection. All internal parts can be serviced without disturbing the piping connections. Withstands waterhammer and superheat Stainless steel balanced pressure thermostatic air vent. Withstands waterhammer and steam temperatures up to 572 F. valve trim Corrosion resistant, hardened valve head. Long wear life. No steam leakage Maximum thermal efficiency, but drains condensate as soon as it forms. Condensate seals the valve at all times, preventing steam leakage. 3

Float & Thermostatic Steam Traps FT and FTI The FT and FTI Float & Thermostatic steam traps are traditional cast iron products available with either parallel (FT) or in-line (FTI) connections. These traps are offered for steam pressures up to and condensate loads to 10,000 lb/hr. The stainless steel air vent, fl oat, and valve eliminate air binding, resist corrosion and allow for continuous drainage of condensate. FT-15 FT-30 FT-75 FT-125 FT-150 FT-200 1-1/4", 1-2" 1-1/4", 1-2" 1-1/4", 1-2" 1-1/4", 1-2" 1-1/4", 1-2" 1-1/4", 1-2" Cast Iron NPT Parallel Cast Iron NPT Parallel Cast Iron NPT Parallel Cast Iron NPT Parallel Cast Iron NPT Parallel Cast Iron NPT Parallel TI-2-313 US TI-2-313 US TI-2-313 US TI-2-313 US TI-2-314 US TI-2-314 US 15 psig 30 psig 75 psig 125 psig 150 psig FTI-15 FTI-30 FTI-75 FTI-125 FTI-200 3/4", 1" 3/4", 1" 3/4", 1" 3/4", 1" 3/4", 1" Cast Iron NPT Cast Iron NPT Cast Iron NPT Cast Iron NPT Cast Iron NPT TI-2-321 US TI-2-321 US TI-2-321 US TI-2-321 US TI-2-321 US 15 psig 30 psig 75 psig 125 psig FT & FTI-15 to FTI-200 Capacities For complete capacity data, see TI-2-317-US. Condensate, lb/h Differential Pressure, psi 4

FT14 and FT14C The FT14 features rugged cast iron (1") or ductile iron (1-1/2" and 2") construction for pressures up to. The convenient in-line connections allow for servicing of all trap internals without removing the trap from the pipeline. The stainless steel air vent, fl oat, and valve eliminate air binding, resist corrosion and allow for continuous drainage of condensate. FT14-4.5 FT14-10 FT14-14 1" HC, 1-2" 1" HC, 1-2" 1" HC, 1-2" Cast Iron (1"), Ductile Iron (1-1/2" & 2") Cast Iron (1"), Ductile Iron (1-1/2" & 2") Cast Iron (1"), Ductile Iron (1-1/2" & 2") NPT NPT NPT SLR with air vent SLR with air vent SLR with air vent TI-2-320 US TI-2-320 US TI-2-320 US 65 psig 145 psig IFT14 and FT14C The IFT14 1/2" & 3/4" sizes offers a compact Float & Thermostatic steam trap with in-line fl ow designed for horizontal or vertical piping. The rugged ductile iron construction is suitable for pressures up to and capacities to 1,000 lb/hr. The stainless steel air vent, fl oat, and valve eliminate air binding, resist corrosion and allow for continuous drainage of condensate. IFT14-4.5 FT14-4.5C IFT14-10 FT14-10C IFT14-14 FT14-14C 3/4" Ductile Iron NPT 3/4" Ductile Iron NPT 3/4" Ductile Iron NPT SLR with air vent SLR with air vent SLR with air vent TI-2-320 US TI-2-320 US TI-2-320 US 65 psig 145 psig IFT-14, FT14 & FT14C Capacities For complete capacity data, see TI-2-306-US. Condensate, lb/h Differential Pressure, psi 5

FTB The FTB range of Super Capacity Float & Thermostatic steam traps are rugged cast iron products designed to handle large heat exchanger condensate loads to 100,000 lb/hr. The stainless steel air vent, fl oat, and valve eliminate air binding, resist corrosion and allow for continuous drainage of condensate. FTB-20 2" Cast Iron NPT Parallel FTB-30 2" Cast Iron NPT Parallel FTB-50 1-1/2" Cast Iron NPT Parallel FTB-125 2-1/2" FTB-175 FTB-200 2", 2-1/2" Cast Iron or Cast Steel (2-1/2" only) Cast Iron NPT or SW (2-1/2" only) NPT or SW (2-1/2" only) Parallel Parallel TI-2-315 US TI-2-315 US TI-2-315 US TI-2-315 US TI-2-322 US TI-2-315 US 1-1/2" Cast Iron NPT TI-2-315 US Parallel 2-1/2" Cast Steel SW TI-2-322 US 20 psig 30 psig 50 psig 125 psig 175 psig 3/4"- 2" 3"& 4" FT450 For processes that require pressures to 465 psig and/or steel construction, the FT450 offers the best solution. The FT450 is available in sizes ranging from 3/4" to 4" and with threaded, socket weld or fl anged connections. The in-line design allows all internal parts to be serviced without removing the trap from the pipeline. The stainless steel air vent, fl oat, and valve eliminate air binding, resist corrosion and allow for continuous drainage of condensate. FT450-4.5 FT450-10 1-2" 1-2" Cast Steel Cast Steel FT450-14 3/4", 1" Cast Steel FT450-21 3/4", 1" Cast Steel FT450-32 1-2" Cast Steel FT450 3", 4" Cast Steel NPT, SW, Flanged NPT, SW, Flanged NPT, SW, Flanged NPT, SW, Flanged NPT, SW, Flanged NPT, SW, Flanged Special Order Special Order Special Order Special Order Special Order Special Order TI-2-304 US TI-2-304 US TI-2-304 US TI-2-304 US TI-2-304 US TI-2-3041 US 65 psig 145 psig 300 psig 465 psig 465 psig FTB 1-1/2" to 2-1/2" Capacities For complete capacity data, see TI-2-317-US. FT450 & FT46 Capacities For complete capacity data, see TI-2-308-US and TI-2-3041 US (3" and 4"). Condensate, lb/h Differential Pressure, psi Condensate, lb/h Differential Pressure, psi 6

OK150-300 and UFT Series The UFT Series of Traps is an austenitic stainless steel maintenance free sealed ball fl oat steam trap with an integral automatic air venting capability. The UFT is designed for differential steam pressures up to 465 psig. When installed with a suitable pipeline connector the UFT can easily and simply be removed without breaking into the pipeline, thus speeding up trap replacement with minimal system downtime. Pipeline connectors are available with screwed, socket weld and fl anged end connections. OK150H 1/2" OK150V 1/2" OK300H 1/2" OK300V 1/2" Forged steel & stainless steel Forged steel & stainless steel Forged steel & stainless steel Forged steel & stainless steel NPT or SW - TI-2-312 US 150 psig NPT or SW In-line vertical - TI-2-312 US 150 psig NPT or SW - TI-2-312 US 300 psig NPT or SW In-line vertical - TI-2-312 US 300 psig UFT14-4.5 UFT14-10 UFT14-14 UFT32-21 UFT32-32 3/4", 1"* 3/4", 1"* 3/4", 1"* 3/4", 1"* 3/4", 1"* Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel NPT or SW* NPT or SW* NPT or SW* NPT or SW* NPT or SW* * Connection size and connection type determined by connector type, purchased separately. - TI-P146-02 US 65 psig - TI-P146-02 US 150 psig - TI-P146-02 US - TI-P146-02 US 300 psig - TI-P146-02 US 465 psig OK150-300 and UFT Series Capacities For complete capacity data, see TI-P146-02-US. OK-150 and OK-300 Inlet Pressure psig 10 25 50 150 200 300 OK150 300 420 540 800 - - OK300 145 200 260 400 440 510 Condensate lb/hr Pressure (barg) 0.1 0.2 0.3 0.5 1 2 3 4 5 10 20 32 992 450 882 682 441 220 UFT14-4.5 UFT14-10 UFT14-14 UFT32-21 UFT32-32 400 300 200 100 Condensate kg/hr 110 88 68 44 22 1.5 2.9 4.4 7.3 14.5 29 43.5 58 72.5 145 290 Pressure (psig) 50 40 30 20 10 7

FTS14 and FT46 The FTS14 and FT46 Float & Thermostatic steam traps are designed for clean steam and other systems requiring stainless steel construction. These traps are available with convenient in-line connections for ease of maintenance and either fl anged (FT46) or threaded (FTS14) connections. The stainless steel air vent, fl oat, and valve eliminate air binding, resist corrosion and allow for continuous drainage of condensate. FTS14-4.5 3/4" NPT, socket weld, end, tri-clamp Internal Strainer TI-P145-01 US 65 psig FTS14-10 3/4" NPT, socket weld, end, tri-clamp Internal Strainer TI-P145-01 US 145 psig FTS14-14 3/4" NPT, socket weld, end, tri-clamp Internal Strainer TI-P145-01 US FT46-4.5 1-2" Flanged 3/8" NPT drain connection TI-2-318 US 65 psig FT46-10 1-2" Flanged 3/8" NPT drain connection TI-2-318 US 145 psig FT46-14 1-2" Flanged 3/8" NPT drain connection TI-2-318 US FT46-21 1-2" Flanged 3/8" NPT drain connection TI-2-318 US 300 psig FTS14 Capacities For complete capacity data, see TI-2-317-US. See FT450 capacities for FT46. Differential pressure bar (x 100 = kpa) lb/hr flow Condensate kg/h Differential Pressure (psig) 8

How Float and Thermostatic Traps work On start-up, air in the system is quickly discharged through the integral thermostatic air vent (1). When condensate reaches the trap it raises the float to open the main valve. Cool condensate is discharged through both the main valve and the air vent (2). When the trap reaches operating temperature the air vent closes and condensate at steam temperature is discharged continuously through the main valve. The opening of the main valve is regulated by the condensate level in the trap so that condensate never backs up into the inlet piping. Air which accumulates in the trap during operation is periodically discharged through the thermostatic air vent. Certain models can be supplied with a steam lock release (SLR) which provides an adjustable steam bleed (3). An SLR should be specified whenever the piping arrangement may permit the formation of a steam pocket which can prevent condensate from reaching the trap. 1. 2. 3. Applications Steam Separator Steam Unit Heater Wet steam can damage equipment and reduce process efficiency. A Spirax Sarco separator efficiently knocks out condensate droplets in the steam flow. If condensate is not drained continuously from the separator, it could be re-entrained in the steam flow. Because of its continuous, modulated discharge, a Spirax Sarco Float & Thermostatic steam trap is ideal for this application. If condensate backs up into the heater, the heat output will be reduced and corrosion could occur at the steamcondensate interface. The steam trap must react instantly to large variations in load. Steam unit heaters must be fitted with a Float & Thermostatic steam trap; no other type has all of the required performance characteristics. 9

Applications Steam Main Drip To remove the condensate which always forms in steam distribution mains, a drip point must be installed at every low point and every two or three hundred feet in horizontal runs. An equal tee ensures that condensate flowing along the bottom of the main will fall into the collecting leg. The Float & Thermostatic steam trap s air vent efficiently eliminates the air which is present at start-up. Steam Lock Release When condensate must be lifted to the trap or when the trap must be located some distance from the equipment, the inlet piping may become filled with steam which prevents condensate from reaching the trap. A steam lock release (optional on certain Float & Thermostatic models) allows the locked steam to be bled off to the return line. Please consult Spirax Sarco for details. Air Handling Coil For accurate temperature control and prevention of freezing, waterhammer and corrosion, the coil must be kept entirely free of condensate and air. Because of its air handling ability, its instantaneous response to variations in condensate load and pressure, and its continuous operation, a Float & Thermostatic steam trap is the only type acceptable for this application. For critical installations, two traps, each of which can handle the full load, should be fitted in parallel. When the condensate return system is not pressurized, the traps should be mounted as far as possible directly below the coil to provide a hydrostatic head to assist in drainage. Stall Conditions Sufficient pressure must always be present at the steam trap inlet to overcome any back pressure caused by a pressurized return line or a lift after the trap. The system will stall whenever the control valve reduces the steam space pressure below the required amount. If this condition is a possibility, a Spirax Sarco Pressure Powered Pump should be installed. The Pressure Powered Pump uses steam at full line pressure to force condensate through the steam trap against the back pressure. Complete details will be found in the Spirax Sarco Pressure Powered Pump Product Bulletin. 10

Shell and Tube Heat Exchanger Because the Float & Thermostatic steam trap discharges condensate continuously, it does not cause the heat exchanger pressure to fluctuate by cycling open and closed. The control valve can therefore maintain a more accurate temperature. The automatic elimination of air and other gases improves temperature control and reduces the possibility of corrosion. A vacuum breaker permits condensate to drain by gravity when the control valve calls for sub-atmospheric shell pressures. Guide to selection 1. Need to know 1. The steam pressure at the trap after any pressure drop through the control valve or equipment. 2. The distance the condensate must be lifted after the trap. Rule of thumb: 2 feet of lift equals 1 psi back pressure (approx). 3. Any other possible sources of back pressure in the condensate return system. For example: Condensate taken to a pressurized deaerator tank or fl ash recovery vessel. Local back pressure due to discharge of numerous traps close together into an undersized return. 4. Quantity of condensate handled. Obtained from: Measurement Calculation Manufacturer s data 5. Safety Factor that is dependent upon particular application, typical examples as follows: Steam Mains 2:1 Tracers 2:1 Non-Modulatng 2:1 Modulating over 30 psi 3:1 Modulating under 30 psi Size trap at full load and 1/2 psi differential Rule of thumb: Use a factor of 2 on everything except Temperature Controlled Air Heater Coils and Converters, and Siphon Applications 2. How to size The difference between the steam pressure at the trap inlet and the total back pressure, including that due to lift after the trap, is the differential pressure. The quantity of condensate should be multiplied by the appropriate safety factor to produce the sizing load. The trap may now be selected using the differential pressure and the sizing load. Note: The inlet pressure to the steam trap should never exceed the Maximum Operating Pressure (PMO) of the selected trap, regardless of differential pressure. 3. Example A steam trap is required to drain 2,000 lb/h of condensate from a Unit Heater receiving steam at 100 psig. There is a lift after the trap of 10 ft. 1. Inlet Pressure 100 psig Lift 10 ft. = 5 psi (approx.) 2. Therefore, Differential Pressure 100 psi - 5 psi = 95 psi 3. Quantity 2,000 lb/h Safety Factor 2:1 4. Sizing Load 4,000 lb/h A 1-1/2 FT-125 will handle 4,120 lb/h at 95 psi differential pressure. (See page 4.) 11

Regional Hub Offices NORTHEAST Spirax Sarco, Inc. 7760 Olentangy River Road Suite 120 Columbus, OH 43235 Phone: (614) 436-8055 Fax: (614) 436-8479 MIDWEST Spirax Sarco, Inc. 1500 Eisenhower Lane Suite 600 Lisle, IL 60532 Phone: (630) 493-4525 Fax: (630) 724-9176 MID-ATLANTIC Spirax Sarco, Inc. 4647 Saucon Creek Rd. Suite 102 Center Valley, PA 18034 Phone: (800) 251-7676 Fax: (800) 996-3232 SOUTHWEST Spirax Sarco, Inc. 203 Georgia Ave. Deer Park, TX 77536 Phone: (281) 478-4002 Fax: (281) 478-4615 SOUTHEAST Spirax Sarco, Inc. 115 Atrium Way, Suite 118 Columbia, SC 29223 Phone: (800) 883-4411 Fax: (803) 865-0459 WEST Spirax Sarco, Inc. 1930 East Carson Street Suite 102 Long Beach, CA 90810 Phone: (310) 549-9962 Fax: (310) 549-7909 SPIRAX SARCO, INC. 1150 NORTHPOINT BLVD. BLYTHEWOOD, SC 29016 t: 800.883.4411 or 803.714.2000 f: 803.714.2222 www.spiraxsarco.com/us Printed in USA 8/06. Copyright 2006 Spirax Sarco, Inc. SPB 1008