Product Data INDUSTRY LEADING FEATURES / BENEFITS

Similar documents
Product Data. 40MBDQ Ducted Slim Ductless System Sizes 09 to 58 INDUSTRY LEADING FEATURES / BENEFITS TABLE OF CONTENTS

INDUSTRY LEADING FEATURES / BENEFITS TABLE OF CONTENTS. DLFSDA and DLFLDA Ducted Style Ductless System Sizes 09 to 58

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MA*R Outdoor Unit Single Zone Ductless System Sizes 09 to 36

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MAQ High Wall Ductless System Sizes 09 to 36

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*F / 38MAQ Floor Console Ductless Split System Sizes 09 to 12

DLFSCA and DLFLCA Cassette Ductless System Sizes 9 to 48 INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*F / 38MAQ Floor Console Ductless Split System Sizes 09 to 12

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*C / 38MAQ Cassette Ductless Split System Sizes 09 to 18

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MVC / 38MVC 40MVQ / 38MVQ High---Wall Duct Free Split System Sizes 009 to 024

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*C / 38MAQ Cassette Ductless Split System Sizes 09 to 18

Product Data. 38GJQ / 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Multi---Zone Ductless Split System Size 18K, 24K, 30K, 36K, 42K, 48K and 56k

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MHRB Outdoor Unit Single Zone Ductless System Sizes 09 to 24

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MPRA Outdoor Unit Single Zone Ductless System Sizes 09 to 12

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MAQ / 38MAQ High- Wall Ductless Split System Sizes 09 to 30

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GRQ / 38GRQ High- Wall Ductless Split System Sizes 09 to 18

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GRQ / 38GRQ High Wall Ductless Split System Sizes 09 to 18

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MBQ Outdoor Unit Single Zone Ductless System Sizes 36 to 48

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*D / 38MAQ / 38MBQ Ducted Split System Sizes 09 to 48

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MB*D / 38MAQ / 38MBQ Ducted Split System Sizes 09 to 48

Product Data. 38GVM / 40GVM Multi---Split High---Wall Ductless Split System 38GVM --- Size 18k, 24k, 30k, 36k and 42k 40GVM --- Size 9k, 12k, and 18k

Product Data. 38GXM / 40GXM Multi---Split High---Wall Duct Free Split System 38GXM --- Size 18k, 24k, and 30k 40GXM --- Size 9k, 12k, and 18k

Product Data INDUSTRY LEADING FEATURES / BENEFITS. DHCMA / DACMA DHQMA / DAQMA High Wall Ductless System Sizes 09 to 22

Product Data. DLCERA Outdoor Unit Single Zone Ductless System Sizes 09 to 24 INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GVC / 38GVC 40GVQ / 38GVQ High---Wall Ductless Split Systems Size 009K K

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40GXC / 38GXC 40GXQ / 38GXQ Inverter---Driven High Wall Duct---Free Split System Sizes 009 to 024

PERFORMANCE DATA Model Numbers Cooling High Heating 47 F Low Heating 17 F

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38MG / 40MA / 40MB Multi- Zone Ductless Split System Size 18k, 27k, 36k and 48k INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 INDUSTRY LEADING FEATURES / BENEFITS

Product Data. High --- Wall Duct --- Free Split systems INDUSTRY LEADING FEATURES / BENEFITS

Owner s Manual TABLE OF CONTENTS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40QAC / 38HDR 40QAQ / 38QRR Ceiling---Suspended Duct Free Split System Sizes 018 to 060

Product Data. 38MGQ Multi-Zone Ductless System Sizes 18, 27, 36 and 48 INDUSTRY LEADING FEATURES / BENEFITS

Installation Instructions

Owner s Manual TABLE OF CONTENTS

Owner s Manual TABLE OF CONTENTS

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Installation Instructions

Installation Instructions

Owner's Manual TABLE OF CONTENTS

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Service Manual CAUTION ! WARNING SAFETY CONSIDERATIONS INTRODUCTION. 40MFC / 38MFC 40MFQ / 38MFQ High Wall Ductless System Sizes 09 to 22

Installation Instructions

Owner s Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS

TECHNICAL SPECIFICATIONS

Installation Instructions

Installation Instructions

Installation Instructions

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MKCB / 24AHA4 / 124ANS 40MKQB / 25HHA4 / 224ANS High---Wall Ductless Split System Sizes 18 to 32

Service Manual CAUTION. 40MBDQ Ducted Style Ductless System Sizes 18 to 48 ! WARNING

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Product Data. S UTEC ignition control and fan timer board provide. S S Cabinet features an insulated enclosure for the burner

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Installation Instructions

R4H4. Product Specifications

Residential and Light Commercial Ductless Systems Catalog

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Hi - Wall Split Systems 12K - 18K - 24K

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

5) Do not start or stop the unit by inserting or pulling out the power plug.

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Service Manual CAUTION ! WARNING SAFETY CONSIDERATIONS INTRODUCTION 619PB / 538PR HIGH-WALL DUCTLESS SPLIT SYSTEM SIZES 09 TO 30

R4H4. Product Specifications

Installation Instructions

Installation Instructions Read and become familiar with these instructions before beginning installation.

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Duct Free Systems Product Data Digest ¾ to 5 Nominal Tons

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

PAJ3. Product Specifications

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Owner s Manual TABLE OF CONTENTS

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Product Data. 58CMA MULTIPOISE OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES CMA FEATURES/BENEFITS

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

N4H4. Product Specifications

Advance Release September 2009

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Transcription:

MBDQ Ducted tyle Ductless ystem izes to Product Data INDUTRY LEADING EATURE / BENEIT A PERET BALANE BETWEEN BUDGET LIMIT, ENERGY AVING AND OMORT. The MBDQ series ducted style ductless systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires. The fan coil is mounted in the ceiling. This selection of fan coils permits creative solutions to design problems such as: NOTE: Images for illustration purposes only. Actual models may be slightly different. Add ons to current space (an office or family room addition) pecial space requirements When changes in the load cannot be handled by the existing system. Historical renovations or any application where preserving the look of the original structure is essential. These compact indoor fan coil units take up very little space above the ceiling. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels.

LOW OUND LEVEL When noise is a concern, the ductless split systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork. EURE OPERATI If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since outdoor units can be installed close to an outside wall, coils are protected from vandals and severe weather. AT INTALLATI This compact ductless system is simple to install. A mounting bracket and duct work is needed for the indoor units, and only wire and piping need run between the indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the ducted style ductless systems the equipment of choice, especially in retrofit situations. IMPLE ERVIING AND MAINTENANE Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. oils can be cleaned quickly from the inside using a pressure hose and detergent. On all indoor units, service and maintenance expense is reduced due to easy accessible service panels. In addition, these ducted systems have extensive self diagnostics to assist in troubleshooting. BUILT IN RELIABILITY Ducted style ductless system indoor and outdoor units are designed to provide years of trouble free operation. The ducted indoor units include protection against freeze up and high evaporator temperatures on heat pumps. The condensing units on heat pumps are protected by a three minute time delay before the compressor starts the over current protection and the high temperature protection. INDIVIDUAL ROOM OMORT Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year round comfort can be provided with heat pumps. EOMIAL OPERATI The ducted style ductless system design allows individual or multi room heating or cooling when required. There is no need to run large supply air fans or chilled water pumps to handle a few spaces with unique load patterns. EAY TO UE TROL The ducted units have microprocessor based controls to provide the ultimate in comfort and efficiency. The user friendly wired and wireless remote control provides the interface between user and the unit. BUILT IN NATE LIT PUMP actory installed condensate lift pump on the ducted fan coil provides installation flexibility. OPTIAL WI TROLLER Timer unction TANDARD WI TROLLER 7 Day Programmable AGENY LITING All systems are listed with AHRI (Air onditioning, Heating & Refrigeration Institute), and ETL. 2

MOL NUMBER NOMENLATURE INDOOR UNIT MB D Q 9 - - - 3 = AN OIL UNIT MB = MOL VOLTAGE 3 = 2/23--6 INDOOR AN OIL TYPE D = DUTED TYLE YTEM TYPE Q = HEAT PUMP NOMINAL APAITY - -/2 T 2-2 T 36-3 T - T NOT UED NOT UED Use of the AHRI ertified TM Mark indicates a manufacturer s participation in the program or verification of certification for individual products, go to www.ahridirectory.org. 3

TANDARD EATURE AND AEORIE Ease Of Installation Mounting Brackets Low Voltage ontrols omfort eatures Rear or Bottom Return Microprocessor ontrols Wired Remote ontrol (7 Day Programmable KAN5AAA Wireless Remote ontrol Auto Restart unction old Blow Protection On Heat Pumps reeze Protection Mode On Heat Pumps Turbo Mode Auto hangeover On Heat Pumps ollow Me (ense Temperature at remote) Energy aving eatures Outside Air Intake leep Mode top/tart Timer 6 Heating Mode (Heating etback) afety And Reliability Indoor oil reeze Protection Indoor oil High Temp Protection in Heating Mode Aluminum Blue Hydrophilic pre-coated fins Ease Of ervice And Maintenance leanable ilters Diagnostics Liquid Line Pressure Taps Application lexibility Built-in ondensate Lift Pump Legend tandard A Accessory

DIMENI INDOOR Air filter Air inlet from rear side Outside air intake -install hanger Electric control box.9in (25mm) Drain pipe Gas connection Liquid connection Test mouth & Test cover.9in (25mm) Drain connecting pipe (for lift pump) Air filter Air inlet from bottom side ig. Indoor Unit OUTLINE DIMENI AIR OUTLET OPENING IZE AIR RETURN OPENING IZE HANGER BRAKER RERIGERANT PIPE LOATI OPERATING WEIGHT lb (kg) ize Unit A B D E G H I J K L M H H2 W W2 In. 3.65.27 26.5 23.62 5.5 27..97 5.35 3.79 7..57 36.22 2 3.7 5.3 3.6. 5 mm 2 67 6 76 5 36 72 9 92 5 7 2 2.5 In. 3.3 9. 3.7 27.56 5.5 36.6.97 6.9 39..9.2. 23.5 3.5 5.9 5.2 6. 7 2 mm 29 77 7 926 5 75 22 5 59 5 3 55 39. In. 53.5 9. 3.7 27.56 5.5 6.69.97 6.9 9.65.9.2 55.2 23.5 3.5 5.9 5.2 6. 6 36 mm 36 29 77 7 6 5 75 26 22 5 59 5 3 55.3 In. 7.2. 3. 3.5...97.9 3.35.2.2.2 27. 3.5 5.9 7.2.27 2 mm 2 3 7 23 5 227 2 5 2 697 5 5 2 5.3 5

>.in(3cm) (When no ceiling) LEARANE INDOOR Left side >in(cm) Maintenance space trong and durable ceiling Indoor unit >.in(3cm) Right side ig. 2 Installation learances >.in(2cm) >.in(2cm) ervice access loor eiling >.in(3cm) >.2in(25cm) MAINTENANE LEARANE >.in(cm) A ervice access ilter service clearance Unit (only one side is required) A/2 A/2 >in(cm) OIL NETI AREA NATE DRAIN PIPING AREA NATE PUMP ERVIE LEARANE ENOR ERVIE LEARANE ervice access >.in 3cm BLOWER/MOTOR ERVIE LEARANE PB BOARD ERVIE LEARANE ILTER ERVIE LEARANE ig. 3 Maintenance learances apacity (Kbtu) A B K 36.22in.(92cm).in.(3cm) 2K 36.22in.(92cm).in.(3cm) 36K.in.(cm).in.(3cm) K 7.2in.(2cm) 5.75in.(cm) 6

PEIIATI ystem Electrical ontrols Operating Range Piping Indoor Heat Pump ize 6 Indoor Model MBDQ---3 MBDQ2---3 MBDQ36---3 MBDQ---3 Voltage, Phase, ycle V/Ph/Hz 2/23--6 2/23--6 2/23--6 2/23--6 Power upply Indoor unit powered from outdoor unit MA A..2.2 2.5 3.2 Wireless Remote ontroller tandard tandard tandard tandard ( / onvertible) Wired Remote ontroller ( / onvertible) tandard tandard tandard tandard ooling Indoor DB Min -Max ( ) 63~9 (7~32) 63~9 (7~32) 63~9 (7~32) 63~9 (7~32) Heating Indoor DB Min -Max ( ) 32~6 (~3) 32~6 (~3) 32~6 (~3) 32~6 (~3) Pipe onnection ize - Liquid in (mm) / (6.35) 3/ (9.52) 3/ (9.52) 3/ (9.52) Pipe onnection ize - uction in (mm) /2 (2.7) 5/ (6) 5/ (6) 5/ (6) Unit Width in (mm) 3.65 () 3.3 () 53.5 (36) 7.2 (2) Unit Height in (mm).27 (2) 9. (29) 9. (29). (3) Unit Depth in (mm) 26.5 (67) 3.7 (77) 3.7 (77) 3. (7) Net Weight lbs (kg) 5 (2.5) 6.6 (39.) 6. (.3) 9.7 (5.3) Number of an peeds 3 3 3 3 Airflow (lowest to highest) M 3// /7/7 7/9/ 72/3/23 ound Pressure (lowest to highest) db(a) 35/37/39 35.5// 3.5/2/5.5 6/9.5/5.5 Max tatic Pressure In.WG...6.6.6 ield Drain Pipe ize O.D. in (mm) (25.) (25.) (25.) (25.) Performance may vary based on the outdoor unit matched to. ee the compatible outdoor units product data for Performance Data. OMPATIBILITY TABLE Indoor Unit MBDQ---3 MBDQ2---3 MBDQ36---3 MBDQ---3 Outdoor Unit ingle Zone 3MAQBR--3 3MAQB2R--3 3MBRQ36A--3 3MBRQA--3 3MGRQ2--3 Outdoor Unit Multi-zone 3MGRQ3D--3 3MGRQ36D--3 3MGRQE--3 NOTE: Backward compatible with ingle Zone ystems 3MAQ sizes 9 2, 3MBQ izes 36 and Multi zone ystems 3MGQ. 7

APPLIATI DATA UNIT ELETI elect equipment to either match or that can handle slightly less than the anticipated peak load. This provides better humidity control, fewer unit cycles, and less part load operation. or units used in spaces with high sensible loads, base equipment selection on unit sensible load, not on a total anticipated load. Adjust for anticipated room wet bulb temperature to avoid undersizing equipment. UNIT MOUNTING (INDOOR) Refer to unit Installation Instructions for further details. Unit leveling or reliable operation, units should be level in all planes. learance Provide adequate clearance for airflow as shown in ig. 3. Unit location elect a location which provides the best air circulation for the room. These units should be positioned as accessible as possible above the ceiling. The unit return and discharge should not be obstructed by furniture, curtains, or anything which may cause unit short cycling or air recirculation. Duct the unit in the middle of the selected wall (if possible). Duct towards an outside wall, if available, to make piping easier, and place the unit so it faces the normal location of room occupants. UNIT MOUNTING (OUTDOOR) Refer to unit Installation Instructions for further details. Do not install the indoor or outdoor units in a location with special environmental conditions. or those applications, contact your ductless representative. MOUNTING Refer to unit s Installation Instructions for further details. UPPORT Adequate support must be provided to support the weight of all fan coils. Refer to the Physical Data section for fan coil weights, and the base unit dimensional drawings for the location of mounting brackets. YTEM OPERATING DITI OPERATING RANGE Min / Max ( ) ooling Heating Indoor DB 63 / 9 (7 / 32) 32 / 6 ( / 3) Indoor WB 59 / (5 / 29) NOTE: Reference the product Installation Instructions for more information. DRAIN NETI Install drains to meet local sanitation codes. The standard ducted fan coil unit condensate lift pump has a maximum lift of 29.5 in. (75mm). WIRING All wires must be sized per NE (National Electrical ode) or E (anadian Electrical ode) and local codes. Use the Electrical Data table MA (minimum circuit amps) and MOP (maximum over current protection) to correctly size the wires and the disconnect fuse or breakers respectively. Per the caution note, only tranded copper conductors with a 6 volt rating and double insulated copper wire must be used. NOTE: The use of BX cable is not recommended. Recommended onnection Method for Power and ommunication Wiring Power and ommunication Wiring: The main power is supplied to the outdoor unit. The field supplied /3 power/communication wiring from the outdoor unit to the indoor unit consists of four () wires and provides the power for the indoor unit. Two wires are high voltage A power, one is communication wiring and the other is a ground wire. Recommended onnection Method for Power and ommunication Wiring (To minimize communication wiring interference) PowerWiring: The main power is supplied to the outdoor unit. The field supplied power wiring from the outdoor unit to the indoor unit consists of three (3) wires and provides the power for the indoor unit. Two wires are high voltage A power and one is a ground wire. To minimize voltage drop, the factory recommended wire size is /2 stranded with a ground. ommunication Wiring: A separate shielded stranded copper conductor only, with a minimum 6 volt rating and double insulated copper wire, must be used as the communication wire from the outdoor unit to the indoor unit. Please use a separate shielded 6GA stranded control wire.! AUTI EQUIPMENT DAMAGE HAZARD ailure to follow this caution may result in equipment damage or improper operation. Wires should be sized based on NE and local codes. Use copper conductors only with a 6 volt rating and double insulated copper wire.! AUTI EQUIPMENT DAMAGE HAZARD ailure to follow this caution may result in equipment damage or improper operation. Be sure to comply with local codes while running wire from indoor unit to outdoor unit. Every wire must be connected firmly. Loose wiring may cause terminal to overheat or result in unit malfunction. A fire hazard may also exist. Therefore, be sure all wiring is tightly connected. No wire should be allowed to touch refrigerant tubing, compressor or any moving parts. Disconnecting means must be provided and shall be located within sight and readily accessible from the air conditioner. onnecting cable with conduit shall be routed through hole in the conduit panel.

TROL YTEM The indoor unit is equipped with a microprocessor control to perform two functions:. Provide safety for the system 2. ontrol the system and provide optimum levels of comfort and efficiency The main microprocessor is located on the control board of the fan coil unit (outdoor units have a microprocessor also) with thermistors located in the fan coil air inlet and on the indoor coil. Heat pump units have a thermistor on the outdoor coil. These thermistors monitor the system operation to maintain the unit within acceptable parameters and control the operating mode. WIRELE REMOTE TROL WI REMOTE TROL P/N KANAAA (optional available as an accessory) P/N KAN5AAA (included with the Unit). Wired remote controller used for system operation of all ducted units. 2. Kit includes a wired remote controller and a connecting cable. 3. onnect with wire terminal between remote controller and indoor unit.. Display in or and temperature increments every or every. ig. 5 KANAAA (Timer unction) ig. Wireless Remote ontrol. A wireless remote control is supplied for system operation for system operation of all ducted units. 2. Each battery operated wireless (infrared) remote control may be used to control more than one unit. ig. 6 KAN5AAA (7 Day Programmable) AIR LOW DATA ystem ize K 2K 36K K High 7 23 Indoor (M) Medium 7 9 3 Low 3 7 72 OUND PREURE ystem ize K (2/23V) 2K (2/23V) 36K (2/23V) K (2/23V) ooling operation Indoor ound Pressure dba at (High / Med /Low M) 39/37/35 //35.5 5.5/2/3.5 5.5/9.5/6 Heating operation Indoor ound Pressure dba at (High / Med /Low M) 37/36/3.9/39.2/36.7 5./3/39. 5./.5/5.3 OUND PREURE TETING METHOD Unit Outlet Indoor Unit 3.2 ft (m) x 3.2 ft (m) Microphone ig. 7 ound Pressure Testing Method 9

OUND POWER ystem ize K 2K 36K K ooling operation Indoor ound Power dba (H) 6 66.9 62 7. Heating operation Indoor ound Power dba (H) 5 6 55 AN AND MOTOR PEIIATI K 2K 36K K Ducted size (2/23V) (2/23V) (2/23V) (2/23V) material Metal Metal Metal Metal Indoor fan Type LLBJ-5*5*2- LBJ-2*9*2-6 LBJ-2*266*2.7-6 LBJ-23*26*2.7- Diameter inch 6.6 inch 7.7 inch 7.7 inch 9.6 inch Height inch 6.22 inch 7. inch.7 inch.39 inch Indoor fan motor Model ZKN-6---2 ZKN-6---2 ZKN-3-- ZKN-56--- Volts V 2/23 2/23 2/23 2/23 Type D D D D Phase 3 3 3 3 LA.65.65 2.5. Insulation class E E E E afe class IPX IPX IPX IPX Input W 2 2 2 56 Output W 6 6 3 56 Range of current Amps.2±%.2±% 2.5±% 3.2±% Rated current Amps.2.2 2.5 3.2 Rated HP HP.27.27.56.75 peed rev/min 5/7/5 /2/69 3/5/99 9/2/ Rated RPM rev/min 3 3 2 2 Max. input W 6 6 2 56

WIRING DIAGRAM OR E TTING NE TADDR E +2 O NE TADDR E WIRING DIAGRAM (INDOOR UNIT) OR ANTI-OLD WIND W 2 TEL 2 5 ATORY ETTING 2 2 2 EEPROM AULT OR ETTING AUTO-RETART W3 MO AUTO-RETART NOT AUTO-RETART ATORY ETTING 2 OR TE MP. OMPE N ATI(HE ATING) W6 2 2 2 O 6 2 ATORY ETTING 2 ~ ~ ~ ~ ~5 6~3 32~7 ~63 M 2 M 3 AN D MOTOR 2 DRIVER MODLE N 2 EEPROM AULT 2 N3 N WIRE O NTROLLER 3 N5 Reactor INDOOR UNIT MAINBOARD N AN OR THE REH AIR OR ANI GENERATOR ig. Wiring Diagram izes 2 Alarm Remote Output ontrol ALARM /O J7 N3 N33 N23 N NOTE:.The parts with dotted line indicates optional features. 2.Remove the short connector of J7 when you use the "on-off" function. N 3 2 M PUMP DIPL AY BOAR D N6 BLAK WHITE 5 WIRE TROLLER T2 INDOOR OIL TEMP. ENOR T ROOM TEMP. ENOR N5 WATE R LE VE L WITH N3 N9 YELLOW(WHITE) N2 N2 BLAK X Y E N YELLOW YELLOW Y/G BLAK Y/G L L2 MAGNETI To M RING omm.b us TO OUTDOOR UNIT RL2 RL N2 N HEATE R WIRING DIAGRAM 3 3 OR ANTI-OLD WIND M A N D MOTOR W DRIVER MODLE 2 2 2 2 2 N O N EEPROM TEL2 5 AULT 3 REATOR ATORY ETTING N3 N 5 OR ETTING AUTO-RETART M W3 MO AUTO-RETART NOT AUTO-RETART ATORY ETTING OR TEMP. OMPENATI(HEATING) W5 W6 2 2 2 2 2 2 2 2 EEPROM O 6 2 AULT ATORY ATORY ETTING ETTING OR ETTING POWER(D MOTOR MOL LY) EN O POWER OR ETTING NETADDRE E +2 O ~ ~ ~ ~ NE TADDR E ~5 6~3 32~7 ~63 5 7 53 5~772~9 9~56~ 6~ ~6 6 AORDING TO RELATED MOL. 2 2 2 2 N WIRE TROLLER INDOOR UNIT MAINBOARD N 9 X Y E N 2 2 AN OR THE REH AIR OR ANI GENERATOR Y/G N To M omm.b us TO OUTDOOR OMM.BU ALAR M REMOTE OUTPUT TROL ALARM /OJ7 N 3 N 33 N 23 N3 N 5 YELLOW N2 N DIPLAY BOARD N6 BLAK N7 N5 N 2 RL2 RL HEA TER YELLOW N2 N NOTE:.The parts with dotted line indicates optional features. 2.Remove the short connector of J7 when you use the "on-off" function. 2 BLAK M PUMP WIRE TROLLER T2 INDOOR OIL TEMP. ENOR T WHITE ROOM TEMP. ENOR T2B INDOOR OIL OUTLET TEMP. ENOR WATE R LE VE L WITH BLAK Y/G L L2 MAGNETI RING TO OUTDOOR UNIT ig. 9 Wiring Diagram ize 36

GUI PEIIATI INDOOR EILING MOUNTED DUTED TYLE DUTLE UNIT ize Range:.5 to Ton Nominal ooling and Heating apacity Model Number: MBDQ PART GENERAL. ystem Description Indoor, ceiling mounted, direct expansion fan coils are matched with a heat pump outdoor unit..2 Agency Listings Unit is rated per AHRI tandards 2/2 and listed in the AHRI directory as a matched system..3 Delivery, torage, And Handling Units are stored and handled per unit the manufacturer s recommendations.. Warranty (or Inclusion By pecifying Engineer) PART 2 PRODUT 2. Equipment A. General: Indoor, direct expansion, ceiling mounted fan coil. The unit is complete with cooling/heating coil, fan, fan motor, piping connectors, electrical controls, microprocessor control system, and integral temperature sensing. B. Unit abinet: Unit cabinet is constructed of galvanized steel. The cabinet is fully insulated for improved thermal and acoustic performance.. ans: The fan is tangential direct drive blower type with air intake at the rear or bottom of the unit and discharge at the front. D. oil: The coil is a copper tube with aluminum fins and galvanized steel tube sheets. The fins are bonded to the tubes by mechanical expansion and specially blue hydrophilic pre coated for enhanced wet ability. A drip pan under the coil has a factory installed condensate pump and drain connection for hose attachment to remove condensate. E. Motors: The motors has an open drip proof, permanently lubricated ball bearing with inherent overload protection. an motors are 3 speed.. ontrols: The controls consist of a microprocessor based control system which controls the space temperature, determines optimum fan speed, and runs self diagnostics. The temperature control range is 62 to 6 (7 to 3 ) in increments of or, and has a 6 Heating Mode (Heating etback). The wireless remote controller can act as the temperature sensing location for room comfort. The unit has the following functions as a minimum:. An automatic restart after power failure at the same operating conditions as at failure. 2. A timer function to provide a minimum 2 hour timer cycle for system Auto tart/top. 3. Temperature sensing controls sense return air temperature.. Indoor coil freeze protection. 5. Wireless infrared remote control to enter set points and operating conditions. 6. Dehumidification mode provides increased latent removal capability by modulating system operation and set point temperature. 7. an only operation to provide room air circulation when no cooling is required.. Diagnostics provide continuous checks of unit operation and warn of possible malfunctions. Error messages appear on the unit. 9. The fan speed control is user selectable: high, medium, low, or microprocessor controlled automatic operation during all operating modes.. Automatic heating to cooling changeover in heat pump mode. The control includes deadband to prevent rapid mode cycling between heating and cooling.. Indoor coil high temperature protection is provided to detect an excessive indoor discharge temperature when unit is in the heat pump mode. G. Electrical Requirements: The indoor fan motor operates on 2 23V. Power is supplied from the outdoor unit. H. Operating haracteristics: The MBDQ system has a minimum EER (easonal Energy Efficiency Ratio) and HP at AHRI conditions, as listed on the specifications table. I. Refrigerant Lines: All units have refrigerant lines that can be oriented to connect from the side of the unit. Both refrigerant lines need to be insulated. opyright 27 arrier orp. 73 W. Morris t. Indianapolis, IN 623. Edition Date: 2/7 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. atalog No: MBDQ-PD Replaces: NEW 2