CAV-METER ULTRASONIC CAVITATION INTENSITY METER

Similar documents
Before digging into the 10 things you should know let s start with a brief explanation of the process.

CLEANING FOR INFECTION CONTROL Ultrasonic Cleaners. Ultrasonic Cleaners. Copyright Quality Medical Innovations P/L & Majac Medical Products P/L

Whittemore Ultrasonic Cleaner

Is Your Ultrasonic Cleaning System Living Up to Its Potential?

Instruction Manual. Immersible & Flange Type Transducer. Advanced Ceramics Technology (M) Sdn. Bhd A Crest Group Inc. Company

Cleaning systems Overview

Application Data Sheet

ULTRASONIC CLEANERS INSTRUCTION MANUAL MODELS

Hot-dip galvanising lines use cold rolled steel strip

Cavitator Ultrasonic Cleaners

Cavitator Ultrasonic Cleaner Instruction Manual

Advanced Ultrasonics and The Benefits of An Effective Anilox Cleaning Regime

INSTRUCTION MANUAL FOR. Ultrasonic Cleaners AC-400H PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Welcome to. KUDOS Technology in Ultrasonic Cleaning. Applications of KUDOS ultrasonic cleaners

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

Cavitator Ultrasonic Cleaners

WHITE PAPER The Importance of Rinsing in Metal Finishing Operations

Zenith Ultrasonic Generator/Tank and Table-top Systems

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

Impiantistica e macchinari con materie plastiche

Elmasonic S Ultrasonic cleaning units. The sum of all possibilities

BRANSONIC Bransonic Baths

WORK PLAN ULTRASONIC CLEANING USING A HEATED INORGANIC CLEANING FLUID ERIE COUNTY/EPA WRITE PROGRAM. Prepared For:

associates Precision Cleaning Systems 3678 Bassett St., Santa Clara CA Phn: [ 408 ] Fax: [ 408 ]

OPERATIONAL & INSTRUCTION MANUAL. Models: 1000M, 1300M, 2000M and 2100M. (120v) UltraSonic LLC. P.O. Box Cincinnati, Ohio 45255

Cleaning systems Overview

Cleaning systems Overview

Vmusbtpojd!dmfbojoh!xjui!tubuf.pg.uif.bsu!ufdiopmphz

AOUEOUS CLEANING TECHNOLOGY FOR PRECISION ELECTRONIC PARTS

+ English + 1. Safety warnings

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

DESIGN AND FABRICATION OF COMMERCIAL UTENSIL STERILIZER PROJECT REFERENCE NO.: 38S1596

CATALOG 100 MIGI KLEEN

ENCAPSULATION CLEANING TECHNOLOGY. An overview of encapsulation chemistry and its applications

ESD BROADLOOM / CARPET TILE CARE AND MAINTENANCE

Soil Moisture Probe. Frizzell ltd. Owners Manual And Reference. Model SMP3A. frizzell ltd. Box 32 Kirwee Canterbury, 7543 New Zealand Ph:

JOKE Basic-Clean. Ultrasonic cleaners. Instruction Manual

PARTS CLEANING AND DEGREASING

Operating Instructions

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION

Designed With You In Mind. Sweep Frequency - Industrial Transducers Improve Performance

ultrasuoni ok :28 Pagina 2 C M Y CM MY CY CMY K English Sterilization line Eurosonic 4D - Energy - Micro Colori compositi

Steam Trap Inspection Methods And Steam Cost Analysis

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

USER MANUAL KGNVCTBVAA

Tovatech LLC Phone (973) Rutgers St, Maplewood, NJ 07040

Operating Instructions

EN-ENGLISH INSTRUCTION MANUAL. METPOINT LKD 300 Leak Detector (LD109) For leak detection in pneumatic systems.

L eather Care & Cleaning

BHC. Replacing Air Sparging Agitation Increases Cleaning Efficiency in Immersion/Soak Tank Degreasing BHC WHITE PAPER

INTRODUCTION UNPACKING & IMPORTANT 3-4 SAFETY INSTRUCTIONS SUGGESTED APPLICATIONS SONIC - D SERIES OPERATION INSTRUCTIONS 7-8 SONIC - MX SERIES 10-11

Precision Ultrasonic Cleaning Equipment Buyers Guide

Microdiesel Cleaning & Assembly Products

Construction Electrical

Manual Ultrasonic Cleaner PCE-UC Series

The Most Powerful Bench-top Ultrasonic Cleaner

If you already own a Sonix IV product you know the quality and have seen the high performance results.

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø)

Ultrasonic cleaning Ultrasonic cleaning devices. Ultrasonic cleaning devices. Edition 5

Model C Electronic Nose Accelerant and Gas Detector Operation and Maintenance

Model 850 Investigator s Aid Accelerant and Gas Detector Operation and Maintenance

Maintain and restore hard floors

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine:

S TAR-ORION S OUTH D IAMOND P ROJECT E NVIRONMENTAL I MPACT S TATEMENT APPENDIX A FUNDAMENTALS OF ACOUSTICS

BioSonic Ultrasonic Cleaning Systems. biosonic.coltene.com

INSTRUCTION MANUAL FOR Freeze Dry Systems PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Contents. Ultrawave baths are manufactured in the UK and conform to exacting international standards.

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

EVac II Programmable Digital Vacuum Gauge

CLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY. natoli.com

Laboratory Scale Spray Dryer SD-15 Operation Manual

SOLO MIDI AVD DUO HIGH PERFORMANCE AQUEOUS COMPONENT CLEANING EXPERTS IN COMPONENT CLEANING PROCESS, CHEMISTRY & TECHNOLOGY

Operating Instructions

Unit D: ph of Soil. Lesson : Identifying the ph Changes in Soil

PORTASCANNER PORTASCANNER TM ISO TECHNICAL SPECIFICATIONS COLTRACO. for Door Fan & Room Integrity Testing. Ult rasonics since 1987

Dry Ice Blasting Frequently Asked Questions

ACCELERATE YOUR CURING TIME

TESTING STEAM TRAPS TO KEEP YOUR SYSTEM OPERATING EFFECTIVELY AND EFFICIENTLY

Model R9100. REED Instruments Instruction Manual. Ultrasonic Leak Detectortor

GENESIS TM ULTRASONIC GENERATORS 25 khz, 40 khz, and 68 khz

Electron Microscopy Sciences

When you sterilize an instrument set, you know what the standards are.

Maintenance Plan for Vegetated Portions of the MS4

616B & 616BT. Open Kettle Fryer. Operator s Manual and. Technical Supplement

MSA / MSA19.710

USER MANUAL MINITRACER PORTABLE SNIFFER

SUBJECT: HOME SCIENCE Class: 10

4.0 EROSION AND SEDIMENT PROCESS. 4.1 Mechanics of Erosion

2. Gas B. The column of hot gases, flames, and smoke rising above a fire; also called convection column, thermal updraft, or thermal column

HEALTH AND SAFETY MANUAL

Best practices in Cleaning and Safety

ULTRASONIC INDUSTRIAL DEVICES

Medical Refrigerator

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

Operating / User Manual

CYCLONIC VACUUM SUPER-TURBO Series. Before use, please read this manual thoroughly and save for future reference.

Changes of phase usually involve a transfer of energy Evaporation

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

LD-5000 REFRIGERANT LEAK DETECTOR

Transcription:

INSTRUCTION MANUAL FOR CAV-METER ULTRASONIC CAVITATION INTENSITY METER PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.VER.01-06-13

Specifications: Range: 0-100, 0-1000 or 0-5000 Self powered- No batteries Weight: 0.96Kg Temperature range: Probe -240ºC to +538ºC, Meter -20ºC to +40ºC Standard probe: 405 mm stainless steel indestructible Meter: 100mm analog With our cavitation meter, you can: Detect loss of ultrasonic energy with periodic readings Calculate best work loads Determine most efficient baskets and work fixtures Compare energy from tank to tank Compare energy level over life of tank Compare energy in tank loaded and unloaded Day to day comparative readings PREFACE To obtain the best and most meaningful results from your Cavitation Meter, you should at least have a basic understanding of what cavitation is, and how it is operated to provide effective cleaning in your ultrasonic cleaning system. This manual attempts to provide the user with this basic understanding of cavitation, as well as an introduction to the operation of MRC's Cavitation Intensity Meter, Model Cav-Meter. We have been using our meter design for over 25 years for calibration field service and lab work. We have found our meter to be dependable and trouble free. The stainless steel probe is virtually indestructible. Many factors must be considered before accepting any given cavitation reading as a direct indication of cleaning efficiency. This manual discusses the most important of these factors. The Cav-Meter is not designed to compare cleaning ability of different frequencies, makes or designs of ultrasonic cleaning equipment. One make or type of equipment that is excellent for a given cleaning task may be quite unsuitable for a different cleaning application. Some operating frequencies are better for certain applications than others, which will be explained later. The Cav-Meter meter is best used for periodic reading of cavitation intensity in an ultrasonic cleaner or cleaning line to determine if the cavitation intensity has dropped over a period of time. It is best to take readings on a weekly basis and keep a record of readings. Another important use is to check the effect of workbaskets, fixtures, and workloads, on the ultrasonic energy in a cleaning tank.

SECTION I INTRODUCTION I. Cavitation Ultrasonic cleaning employs high frequency sound waves, which are above the range of human hearing. These ultra high or "silent" sound waves, when introduced into a cleaning solution, cause microscopic gas bubbles in the cleaning solution to expand to their limit. At this point, enlarged gas bubbles suddenly collapse or implode, giving off tiny but powerful pressure waves. This process is cavitation and the waves emitted by cavitation generate an erosive action. Together with the cleaning solvent, this action creates the desired cleaning effect. Cavitation has been described as countless tiny scrubbers that force dirt and grease from parts immersed in the cleaning liquid.therefore, the purpose of introducing ultrasound into a cleaning solution is solely to provide an intense scrubbing action on the part to be cleaned. It will accelerate the chemical cleaning action of the cleaning solution, making it more effective on soluble soils, and it will break loose tenacious insoluble soils or particulate matter which is ordinarily not removed by chemical action alone. Cavitation exists throughout the entire volume of an ultrasonic cleaning tank, but primarily on the surfaces of the parts to be cleaned. The scrubbing action of the cavitation is carried into all recesses and minute openings of the parts being cleaned wherever capillary action will take the cleaning solution. If cavitation is not occurring as expected, the engineers at MRC Associates are available to help you with your problem. II. Factors Effecting Cavitation Factors include; the frequency and amplitude of the Vibration energy introduced into the liquid, the temperature of the liquid, the kind of liquid used the gaseous condition of the liquid, and many other factors. a. Frequency and Amplitude of Vibrational Energy The amplitude of the vibrational energy must be above a minimum threshold level required to initiate cavitation in the particular cleaning solution used. The frequency of the vibrational energy is also a very important factor. In general, for a given amount of energy applied to a cleaning tank, there will be more intense cavitation at the lower frequencies. This is because at the microscopes gaseous bubbles in the liquid will grow to a much larger size before they collapse and can thus produce a much stronger shock wave. At the higher frequencies, however, the microscopic bubbles will grow to a collapsible size at a more rapid rate and although each collapsing bubble is a smaller implosion, there can be many times the number of implosions per unit time. Thus, the amount of cavitational energy might be the same at two widely different frequencies with different effects in a cleaning solution. This explains why cavitation generated at sonic and very low ultrasonic frequencies is somewhat like scrubbing with a very coarse bristle brush and cavitation generated at higher ultrasonic frequencies (e.g., 40,000 cycles-persecond) is comparable to using a softer brush with many more bristles. This also explains why cavitation generated at very low ultrasonic frequencies can be damaging to delicate parts whereas cavitation generated by using higher ultrasonic frequencies will provide excellent cleaning without damage. In general, ultrasonic frequencies in the range from 20 to 120 KHz are used for ultrasonic cleaning applications.

b. Temperature of Liquid The temperature of a cleaning liquid has various effects upon a cleaning system. Maximum cavitation intensity occurs at a temperature considerably below boiling and approaches zero as the temperature of the liquid approaches boiling. Heating helps to degas (see the next section - Gaseous Condition of the Liquid) the liquid, thereby increasing cavitation. Heating also helps to increase the chemical action of the liquid. Because of the plus and minus affects that temperature has upon an ultrasonic cleaning system, the optimum compromise had to be ascertained to provide the most practical results. It was learned that a temperature of about 130 degrees F. to 140 degrees F. is, generally optimum for aqueous systems. This temperature range provides the most effective compromise of chemical activity and cavitation for most ultrasonic cleaning systems. c. Gaseous Condition of Liquid When a cleaning liquid contains a large amount of dissolved gas, it tends to dampen cavitation intensity. In contradiction, however, a cleaning liquid must have some dissolved gas in order to cavitate. It is the microscopic bubbles of dissolved gas that grow and implode creating the scrubbing action. The proper combination of temperature and gaseous condition of the liquid helps to achieve the best cavitation and over-all cleaning action. d. The Kind of Liquid Used The two broad classifications of ultrasonic cleaning solutions, aqueous and solvent, greatly differ in their effects upon cavitation intensity. Aqueous solutions normally produce a much more intense cavitation effect than do solvent liquids; yet, the cleaning action in the solvent liquid may be much greater than in the aqueous solution for the same type of cleaning job required. The type of soil to be removed determines the type of liquid to be used. Aqueous systems are best for inorganic soils, however, by adding a detergent to the liquid many light greases and oils can be removed. Where heavy organic grease, oil or waxy soils are present, an organic solvent may best do the job. Because of the nature of organic solvents, cavitation intensity is frequently less than intensity in aqueous solutions; yet the solvent action appears to make up for the lower scrubbing activity. For example, if you put a bit of grease in detergent water and stir briskly, the grease will dissolve slowly and perhaps not even completely. But, drop a similar bit of grease into an organic solvent such as kerosene and with just light stirring the grease will quickly thin out and dissolve. However, with no stirring in either case, the grease would remain in either liquid for some time before dissolving completely, if at all. Therefore, cavitation provides the mechanical effect of stirring, which increases the activity of the cleaning liquid. It should be noted, however, that cavitation does not necessarily increase the activity of the solvent chemically per se. It merely stirs up and breaks the soil into finer particles, which then can be acted upon more readily by the chemical action of the cleaning liquid. It should also be noted that cavitation is also not directly effected by the chemical action of the liquid, but only by the

proneness to cavitate the liquid itself. The proneness to liquid and not necessarily by its chemical reactive properties. The major factors that have effects on cavitation intensity are: (1) The size and shape of the tank. (2) The depth of the liquid in the tank. (3) The amount of dissolved soil or suspended particulate matter in the liquid. (4) The inserts or baskets used to contain the parts being cleaned. (5) The number, size and shape of parts to be cleaned. (6) The density and composition of parts to be cleaned. (7) The liquid being used. (8) The temperature of liquid being used. (9) The position of larger and/or odd shaped parts while immersed in the cleaning liquid. (10) The operating efficiency of the system and its associated transducers. The cavitation meter lets you know that cavitation energy exists in the tank. It allows you to compare readings from one time to another and to determine optimum leads and positions in a given tank. In this way, you can keep a running record on the efficiency of your systems. The cavitation meter is not a diagnostic tool in the sense that it will tell you directly what is wrong with your system. It lets you know that cavitation is or is not occurring and, if so, to what relative intensity. III. Cavitation Intensity in "CAVINS" The model Cav-Meter is calibrated in units named "CAVIN" (for CAVitation Intensity). The CAVIN is based on the results of exhaustive tests with the Model Cav-Meter on many and varying ultrasonic cleaning systems in actual use and in the laboratory. Based on these tests, the Model Cav-Meter is calibrated from 0 to 5000 CAVINS. The 5000 CAVIN level is an arbitrarily assigned value for the highest intensity generally encountered in present typical high-intensity aqueous cleaning systems - adjusted for optimum performance without any work load of parts in the cleaning tank. Although aqueous systems will generally give typical readings between 10 and 5000 CAVINS, some liquid will generally give readings much lower. For this reason, the Model Cav-Meter is provided with three range scales; 0 to 100 CAVINS,0 to 1000 CAVINS and 0-5000 CAVINS. The Model Cav-Meter is actually a monitor of cavitation and is most useful when used to monitor a system in which standards have been previously established for the system under optimum conditions. The Cavitation Meter can be used beneficially and can provide meaningful, reasonably accurate results when used with some degree of common sense.

SECTION II DESCRIPTION I. Physical Description The Cavitation Intensity Meter is designed for ease of operation. It is lightweight, self-powered and completely portable. a. Dimensions & Weight Height: 160mm (without probe) Depth: 65mm Width: 100mm Probe length standard: 405mm b. Controls The Sensitivity Select Control provides XI range, X10 range and X50 range for measuring cavitation in your system. c. Test Range & Scale Divisions The test range of the Model Cav-Meter is 0 to 5000 CAVINS, which covers the entire range of cavitation intensity of all known ultrasonic cleaning systems in operation today. On the XI scale, the increments are in CAVIN units and the range is 0 to 100 CAVINS. On the XI0 scale, the increments are in 10 CAVIN units and the range is 0 to 1000 CAVINS. On the X50 scale, the increments are in 50 CAVIN units and the range is 0 to 5000 CAVINS. d. Probe The standard probe is 450mm long, and permanently attached to the meter. The active element of the field probe is a cylindrical transducer which picks up energy enables the meter to read an integrated signal based on the total intensity in the cleaning tank in the immediate vicinity of the probe. This makes the meter insensitive to the angle at which the probe is held. However, moving the probe within the tank will change the meter reading according to the energy levels in the various locations in the tank. II. Electrical Characteristics The Model Cav-Meter operates on power generated by the probe. There are no batteries in the unit.

SECTION III OPERATION I. General The MRC Cavitation Intensity Meter, Model Cav-Meter requires no preparation before it is ready for use. Because of its all solid-state circuitry, the Model Cav-Meter requires no warm-up time. Its operation is easy for even non-technical personnel and the results are read directly from the meter with no need for formulas or other interpretive calculations. II. Testing Cavitation Intensity Just as in any other type of measurement, standards must be established in order to obtain meaningful results. In ultrasonic cleaning, however, each tank or tank type is an entity unto itself. A tank first must be tested under optimum conditions; that is, turned on with a fresh supply of cleaning liquid and heated to its proper operating temperature. Note - When taking readings, the probe should be moved through the liquid in slow, easy movements. Never use quick or jerky movements, for this will affect the accuracy of the readings. a. Aqueous Systems In aqueous systems, the peak intensity should be between 10 and 5000 C A VESTS, depending upon the type of solution used and the operating efficiency of the tank. You know how effectively your tank has been cleaning. If it has been doing the job at least as expected, then the reading obtained under optimum conditions can be used as a good starting point for comparison. (1) To establish standards to which future readings will be compared, readings should first be made and recorded at various levels and parts of the tank under optimum conditions. (2) Next, place standard inserts holders, baskets, etc.) into the tank without parts and record new readings. (3) Loads of varying sizes should be lowered into tank and more comparative readings recorded. This should be continued until cleaning efficiency begins to drop off. Note - Each time a new load is immersed, the cleaning solution should be changed if a gross amount of contamination is encountered. This is to be done to be sure contaminated cleaning liquid is not affecting cavitation intensity that would throw off comparative readings. Each time the liquid is changed it should be brought to operating temperature and pre-checked for intensity to be sure it matches within 10% the intensity recorded under previously optimum conditions. Readings should be made while probe is held in recesses between and around the immersed parts. Once optimum cleaning is noted, the cleaning solution, itself, can be altered in stages until a new optimum cleaning point is obtained. All conditions and resultant readings should be recorded for future comparison.

(4) When the parts to be cleaned are large and can be submerged a few a time, orientation of part/s in the tank should be altered until peak cavitation intensity near or at the surfaces of the parts is noted on the meter. Note - As a general rule, large parts should be reoriented in the liquid on a regular schedule to allow thorough cleaning of all surfaces. This is true because cavitation intensity varies at different levels of a single tank. Reorienting or turning parts on a schedule assures that all surfaces of a part are exposed to the highest cavitation intensity levels in the tank. (5) Because of the many types of tanks and varying transducer configurations to be found, the exact levels of peak intensity will also vary. The Cavitation Intensity Meter will help you determine more precisely where these levels exist in your particular system so that you will be able to properly orient your workloads. SECTION IV MAINTENANCE The design of your Cav-Meter probe eliminates the need for elaborate preventative maintenance procedures. The only recommendation is to keep the unit clean. The probe should be rinsed after each use and the meter should be kept clean and dry. If any problems should occur, please contact MRC Associates. Field adjustments, calibration or repairs can not be made unless the unit is sent to us or instruction is given by phone. GLOSSARY AMPLITUDE- The distance from the high peak or point of a cycle to its lowest point or trough. Opposed to frequency which refers to the number of vertical peaks and valleys or waves in a given horizontal distance or time lapse, amplitude is the vertical distance from each peak to its corresponding valley. Intensity is proportional to the square of the amplitude. AQUEOUS- This term pertains to water or anything resembling or consisting of water. An aqueous solution is a solution of any substance or substances in water.cavin- A term proposed by Branson Instruments in 1966 to represent one unit of cavitation intensity. One CAVIN represents 1/1000 of the peak cavitation observed in tests of many typical aqueous ultrasonic cleaning tanks performed under optimum conditions. CAVITATION- The expansion and rapid implosion of microscopic gas or vapor bubbles produced when high-intensity ultrasonic waves are directed into a liquid.

DAMPING- The extent to which a wave, process or activity is diminished, restrained or checked. FREQUENCY- The rate of vibration or the number of complete cycles of a signal which pass a given point in a second. The greater the number of cycles or peaks and valleys of a signal per second, the higher the frequency. In audible sound the frequency is also referred to as the pitch. HARMONIC (Also OVERTONE)- is a vibration frequency which is an integral, or whole, multiple of the fundamental frequency. WHITE NOISE- The spectrum of sonic and ultrasonic harmonics produced by the imploding bubbles during cavitation. This spectrum extends well into the mega-cycle range. The intensity of these harmonics can be detected and relate directly to cavitation intensity.