MAXA-MI$ER Energy recovery solutions

Similar documents
Energy Recovery with Cooling and Heating Model ERCH

Energy Recovery Ventilators

Energy Recovery with Cooling and Heating

Bill McCullough. Director ERV Products. Dallas, TX

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

Tempra / DHC-E. The Finest Tankless Electric Water Heaters Available! Simply the Best Featuring Advanced Microprocessor Control

Tempra Series WHOLE HOUSE TANKLESS ELECTRIC WATER HEATERS Whole House Comfort

Simply the Best WHOLE HOUSE COMFORT SAVE WHOLE HOUSE TANKLESS ELECTRIC WATER HEATERS

Bosch Tankless Water Heater Troubleshooting Guide

Simply the Best WHOLE HOUSE COMFORT SAVE WHOLE HOUSE TANKLESS ELECTRIC WATER HEATERS

BULK PURCHASE DISCOUNTS Valid for purchases any time of year

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Limestone Cements. Why are we doing this? What are they? What s in it for you? Limestone Cements, Holcim (US) Inc.

Advanced Microprocessor Control The Finest Tankless Electric Water Heaters Available! DHC-E / Tempra

THE ULTIMATE ROOFTOP SOLUTION

Product Release Summary

ADVANTAGE SERIES. Popular Technologies for Outdoor Living

ADDRESS (NO PO BOX) COMMUNICATIONS GENERAL INFORMATION. First Name*: John. Last Name*: Smith. Job Title*: President Company Name*: Custom Homes

Featured Fish-Week ofmay 29th

Griddle Stands REFRIGERATORS & FREEZERS. Call us toll free at (800) INNOVATIVE DESIGNS FOR YOUR FOODSERVICE NEEDS

Inventory Management Guide

MiniCore Ventilator (500, 1000) Series Engineering Guide

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

Hello. What can I do for you? QUALITY CUSTOMER SERVICE. Joseph Griffith Regional Sales Manager. Cooling Tower Depot is Global, I am Local

This presentation is posted for public use. ACEEE does not endorse any product or service.

2018 PRICING. alderonind.com STANDARD PRODUCTS

- Residential Fire Sprinkler -

USE OF A LOWER RATE WHEN APPLIED ON CEREALS AT THE HERBICIDE TIMING (FEEKES 4-6) - AL, AR, AZ ETC.

Standards and Safety Update

DOAS UNITS. ReznorHVAC.com MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR

The ultimate fresh air solution.

AHRI Guideline W (I-P) 2014 Guideline for Selecting, Sizing, & Specifying Packaged Air-to-Air Energy Recovery Ventilation Equipment

Energy Recovery Ventilation

XeteX, Inc. All Rights Reserved.

DES CHAMPS PRODUCTS 85% 4,400 CFM

Cultivator & Hybrid Cultivator

Presentation to NC Home Inspectors Licensure Board April 7, Opportunities and Partnerships

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Marketing Strategies for Energy Star Water Heaters. Keith Burkhardt Marketing Manager, Water Heaters GE Appliances

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

FIRE ALARM SYSTEM INSPECTION

Overview of Biosolids Composting Science, Production and Use Albert Cox Kuldip Kumar

Standard Procedure s for Tenant Fire Sprinkler Work

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Up to 16.1 SEER, Up to 14.3 EER and Up to 15.4 IEER

THE RIGHT SPEC. RIGHT NOW.

NOW I 50% OFF. CALL TODAY! H.L. Flake McDonald Dash ORDER ONLINE! HLFLAKE.COM BUY AT LIST PRICE

Bar Equipment BOTTLE, KEG & BACK BAR COOLERS INNOVATIVE DESIGNS FOR YOUR FOODSERVICE NEEDS

Economical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ

LARGE CAPACITY HEATERS

Continuing Education Units (CEU)

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

PACKAGED HVAC EQUIPMENT CATALOG

DOWNLOAD OR READ : KITCHEN AND BATH SOLUTIONS CLARKSVILLE TN PDF EBOOK EPUB MOBI

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

200 GARDEN COMPOSTER OWNERS MANUAL. SUN-MAR CORP. -The Composting Company. Composting Toilets. Home & Garden Composters CONTACT INFORMATION

Table A-4...Professional and Do-It-Yourself Improvement Expenditures by Homeowner Characteristics: 2007

INFINITI K APPLICATIONS MANUAL. Indoor Residential and Tankless Water Heaters. Warning: Follow each appliance's instructions precisely.

Oklahoma and Texas Interdependency Along the I-35 Corridor

Commercial Packaged Rooftop Units 3- to 50-Ton LC/LG Models UP TO 18.0 SEER, 12.8 EER AND 15.5 IEER

3- to 24-Ton Models. Commercial Packaged Rooftop Units. The most energy-efficient rooftop unit in the industry *

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

Inventory Management Guide

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Trane Performance Climate Changer Air Handlers. An air handler for every need.

TECHNOLOGY GUIDE. :: the dawn of a new era in commercial HVAC technology. The all-new Rheem Commercial Renaissance Line featuring:

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

DEALER SUPPORT REFERENCE LIST

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Poinsettia Season Recap 2012 White Paper

Trane Performance Climate Changer Air Handlers. An air handler for every need.

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

ENGINEERING. Edition No. 13 October 2002

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

BUSINESS SECURITY THAT S A PERFECT FIT. SECURITY SOLUTIONS FOR YOUR BUSINESS

AHRI Certified up to. 95% efficiency P-K MACH HIGH EFFICIENCY, COMMERCIAL BOILERS

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

IAQ VENTILATORS. FRESH AIR REQUIREMENTS. Applications ASHRAE 62.1, 90.1 & School / university / day care.

Submittal Data Performance Data Electrical Data

Put the V back in HVAC

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

High efficiency out of the box

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Table A-4...Professional and Do-It-Yourself Improvement Expenditures by Homeowner Characteristics: 2013

2011 Commercial Water Heating Solutions. Introducing Bosch Therm, our most advanced line of tankless water heaters for commercial applications.

Submittal Summary Page

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Modular Supply Make-Up Air Unit

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

2018 LIGHT COMMERCIAL ROOFTOP UNITS. Industry-leading efficiency and innovation to meet your needs

Advance Release September 2009

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

ALL PRODUCTS BROCHURE

Transcription:

MAXA-MI$ER Energy recovery solutions

Regardless of building type or rating system, today s building must be as energy efficient as possible. The design of an HVAC system is critical to the success of the building s energy performance. Proper ventilation for occupant health and productivity must be addressed. The quality of the indoor environment cannot be sacrificed for the sake of energy efficiency. The YORK MAXA-MI$ER Energy Recovery Ventilator (ERV) is your solution. Increased ventilation rates in combination with energy recovery products not only improve the indoor air quality but also reduce the cost associated with conditioning these larger amounts of outdoor air. Energy recovery solutions from YORK There are many reasons to install an ERV, but the best reasons are to recover energy and lower utility expenses. Workplace and school environments have a high concentration of people and need plenty of fresh air. Adding fresh air lowers the CO 2 levels in a building and helps keep the occupants alert and healthy. ERVs also help control odors as the stale air is exhausted out of the building and fresh air is brought in. When fresh air is brought into a building, conditioned air is exhausted back outside to equalize the pressure. The air leaving a building has energy in it Warm energy in the winter and cool energy in the summer. An ERV captures about 70% of that warm or cool energy from the air leaving the building and puts it back into the fresh air entering the building. This recapturing of energy means the rooftop unit does not have to work as hard, which translates into lower monthly utility bills. Outside Air 92 /45% RH Exhaust Air 88 /46% RH TYPICAL HVAC SYSTEM USING ENERGY RECOVERY SUMMER OPERATION Return Air 75 /51% RH Source: ERV Select Software. Typical installation in Philadelphia Market. Typical HVAC System Using Energy Recovery Summer Operation TYPICAL HVAC SYSTEM USING ENERGY RECOVERY WINTER OPERATION Tempered Air 80 /51% RH Typical applications for energy recovery Outside Air -1 /67% RH Tempered Air 47 /44% RH Animal shelters Bars and clubs Exhaust Air 22 /21% RH Churches Locker rooms Dormitories Nursing homes Return Air 72 /28% RH Office buildings Printing shops Restaurants Schools Source: ERV Select Software. Typical installation in Philadelphia Market. Function halls Veterinary hospitals Typical HVAC System Using Energy Recovery Winter Operation 2

ASHRAE compliance and IAQ ERVs are an excellent choice to comply with outdoor ventilation requirements of ASHRAE 62. Introducing fresh, outdoor air to a building is a key component in sustaining excellent IAQ and occupant productivity. ERVs meet the minimum total effectiveness of 50% for energy recovery per ASHRAE 90.1 and is a preferred method for saving energy in ASHRAE/USGBC/IESNA s Standard 189.1 Standard for the Design of High Performance, Green Buildings Except Low-Rise Residential Buildings. Less tonnage required! Systems using Energy Recovery Ventilators re-use (recycle) about 70% of the energy from the exhaust air to heat, cool, dehumidify or humidify the incoming fresh air, which takes that portion of the load off of the rooftop units. In most conditions, the outside air load is significant and results in less tonnage required to meet the design conditions. Terrific payback! Minimum outside air ventilation requirements are often the largest single load on an air conditioning and heating system especially at design conditions. The greater the degree days and the greater the outside air amount, the greater the savings. YORK ERVs provide an easy-to-use payback program to help calculate your savings. This program takes into account your job location and your specific application. Savings are $$$ubstantial. HVAC utility rebates ERVs can have an immediate impact on your energy budget, but there may be an additional benefit to help offset the cost of the ERV equipment. Utility rebates may be available in your area! Consult your local electricity provider for additional details. LEED-EB and LEED-NC credits For Green Building designs, the MAXA-MI$ER can assist the designer in acquiring credits for Energy and Atmosphere (EA) by optimizing energy performance and for Indoor Environmental Quality (IEQ) by providing the ability to increase ventilation leading to thermal comfort. WA ME OR MT ND VT NH CA NV ID UT WY CO SD NE KS MN IA MO WI IL MI IN OH KY WV NY PA MD VA NJ MA CT DE RI NC AK AZ HI NM TX OK AR LA MS TN AL GA SC FL REGIONAL PAYBACK ERV payback typically 0 to 2 years ERV payback typically immediate ERV payback typically 2 to 7 years 3

MiniVentilator ERVs YORK MiniVentilator ERVs are an outdoor air pre-conditioning system and is perfect for indoor applications. This range of ventilation is typically found in classrooms, meeting rooms, and small retail locations. The MiniVentilator is compact and can be installed in locations that have limited amount of space, comes equipped with duct openings that are interchangeable dependent on your duct configuration. Hanging or pad mount installation capability Movable duct flanges for field convertible outside air and return air intake connections AHRI certified enthalpy wheels with full slide out access Centrifugal forward curved blower with direct drive motors Closed cell insulated cabinet Pleated MERV 8 filters in intake and exhaust airstreams Exclusive ClimateSmart controller for ERV control during economizer mode (X models only) Standard features 250-1500 CFM Painted cabinet Hang or base mounting Access to filters and wheel without tools Flanges on all intake/discharge connections Additional options ECM motors available (MV450/750/1250(X) models) Dirty filter sensor Remote speed controller Remote timer option (24/7) Low ambient kit for frost control Wheel rotation sensor Start/stop/jog economizer control 4

Stand alone ERVs Stand alone ERVs provide more flexibility than packaged MiniVentilators. These ERVs are used to recover exhaust air energy and reintroduce the air in the conditioned space, and can be utilized for indoor or outdoor use. Fresh, outside air enters the ERV and is pretreated before entering the heating and cooling equipment. Whether ducting directly into air handlers, or directly feeding into a rooftop unit, these pre-conditioners provide the ability to reduce overall HVAC tonnage required to maintain comfort in your occupied space. VD Series Stand alone ERVs are designed for ease of maintenance All of the enthalpy wheels are designed to slide in and out of the ERV. This allows easy access to all parts of the wheel. Wheel Pie segments can be removed for easy cleaning. All wiring is color coded to match the wiring diagram. Control boxes are provided with internal fuses. Blower motors are mounted on adjustable bases that allow easy tensioning of the belts. All filters are standard sizes. All options are easily installed by simply plugging them into the appropriate plug. Roof curbs have duct supports. Wheel Pie Segment Adjustable Motor Mount Standard features 600-6200 CFM 208/230-1/3, 460v-3, and 575v-3 available Designed for indoor/outdoor use Powdered coated finish Rotatable clips for easy lifting and mounting Exhaust/intake hoods (outdoor) Flanges on all intake/discharge connections (Indoor) MERV 8 filters Frost control options VFD modulating wheel (28 and larger models) Low ambient kit Electric preheat Additional options Factory installed Metasys ready controller VFD blowers Start/stop/jog (economizer mode) Total enthalpy wheel or sensible only wheel MERV 8/11/13 filter options Smoke detectors CO 2 sensor Dirty filter sensor Start/stop/jog (economizer mode) Total enthalpy wheel or sensible only wheel Smoke detectors CO 2 sensor Dirty filter sensor 5

Full featured ERVs With full energy recovery, high capacity heating and cooling options, and factory installed Metasys ready controls, this unit can effectively maintain the occupied space temperature and humidity, giving you ultimate control of your environment. These units are designed for outdoor use, and when packaged with an RTU, the Full-Featured ERV can provide up to 100% dedicated outside air. The intake and exhaust orientations are selectable to be down flow or horizontal configuration. Hinged access panels Enthalpy energy recovery wheel optional sensible only Double wall construction Rain hood with mist eliminator Post-filter Motorized intake damper Preheat coils for frost control Pre-filter Bacnet capable digital control center (includes rotation sensor) Coil options Chilled water (shown) Hot water 4 Pipe Split DX (r410a) Post heat Indirect gas Electric Horizontal configuration Standard features 600-12,000 CFM Factory installed Metasys ready controls Built with heavy gauge galvanized steel cabinet with powder coated finish Factory mounted NEMA 3R rated disconnect Double wall construction Hinged access panels Powered by Lau Forward Curved Blowers to reduce noise and vibration Adjustable motor sheaves for easy blower adjustments Additional options Start/stop/jog (economizer mode) Motorized intake and exhaust air dampers Dirty filter sensor Low ambient control kit VFD blowers CO 2 sensor Wheel rotation sensor Total enthalpy wheel or sensible only available Smoke detector Pressure gauge Indirect gas heat (2-stage, 5:1 or 10:1) Split DX coil Hot water/chilled water coils Electric pre/post heat options 6

Unitized ERVs Proper ventilation for occupant health and productivity is critical to the success of the building s performance. Increased ventilation rates in combination with energy recovery products not only improve the indoor air quality but also reduce the cost associated with conditioning these larger amounts of outdoor air. YORK Unitized ERVs can be applied to nearly all applications, and to any new or existing rooftop unit. These ERVs offer an inexpensive alternative to energy recovery as an add-on to new and existing rooftop units. No roof penetration The YORK Unitized ERV matches exactly to any existing rooftop unit, eliminating the need for another rood penetration. This not only saves on installation costs, it also eliminates the risk of a roof leak that may occur with roof penetrations. ERV and ECONOMIZER YORK ERVs have a patented wheel design that allows the energy recovery wheel to pivot out of the airstream during 100% economizer mode. This eliminates the pressure drop of the wheel and allows for the best of both worlds an ERV when needed for normal ventilation operation and an economizer when conditions call for it. Standard features 300-6200 CFM Factory installed Metasys controls Built with heavy gauge galvanized steel cabinet with powder paint to color-match to any manufacturers rooftop unit Includes interface wiring harness that connects the economizer directly to the ERV with a single plug (P models) Balancing damper provided for proper air distribution while ERV is in operation (R models) Powered by Lau Forward Curved Blowers to reduce noise and vibration Adjustable motor sheaves for easy blower adjustments Additional options Pivoting wheel (P models) Start/stop/jog (economizer mode) Electronic fan inlet air & temperature measuring station (EFAMS) Hinged access panels Low ambient control kit Motorized intake and exhaust dampers VFD blowers CO 2 sensor Wheel rotation sensor Total enthalpy wheel or sensible only available Smoke detector Pressure gauge 7

Controls The Metasys Building Automation System is the foundation of modern building energy management efficiency. This intelligent, world-class technology system allows your ERV to communicate on a single platform to deliver the information you need, allowing you to make smarter, savvier decisions while enhancing your occupants comfort, safety, and productivity. A full range of FEC/FAC models combined with the Input/ Output Module (IOM) models can be applied to a wide variety of building applications ranging from simple fan coil or heat pump control to advanced central plant management. All FEC Series Controllers configured for BACnet support wireless communications using the ZFR System accessories. Energy and economic payback The energy recovery ventilators were calculated to save South Community High School approximately $60,000 annually or $1.2 million in today s dollars over the average life of the new rooftop units. The initial added investment in wheel based rooftop units is expected to be recouped during the first year of operation based on savings from the energy recovery ventilators alone. Impact of energy recovery wheels Heating capacity saved (btu/hr) 4,727,000 For roughly the same price as a larger, more energy intensive rooftop unit, we can provide the same amount of work with a smaller, wheel-based unit that performs with up to 40% greater efficiency. This translates to significant energy savings over the life of the equipment. CRAIG CAMPBELL TRUMBULL AND CAMPBELL ASSOCIATES Cooling capacity saved (tons) 115 Net capital expenditure (wheel based rooftop units) $55,000 Annual outdoor air energy saving $60,000 Based on $1.10/therm gas, $0.115/kwh, 67,449 cfm outdoor air, 12/5 operation, 10 months/yr. Printed on recycled paper. Johnson Controls, the Johnson Controls logo, Metasys, YORK and MAXA-MI$ER are trademarks of Johnson Controls, Inc., or its affiliates, in the United States of American and/or other countries. 2017 Johnson Controls, Inc. P.O. Box 423, Milwaukee, WI 53201 Printed in USA PUBL-8056 www.johnsoncontrols.com