ASAHI/AMERICA Leak Detection Basics

Similar documents
LEAK DETECTION/LOCATION SYSTEMS PAL-AT LIQUIDWATCH FLUIDWATCH

Minimize Leaks Maximize Asset Protection

Industrial Strength Leak Detection

introduction Submittal Data Sheet CENTRA-GUARD POINT LEAK DETECTION

FMP-MWS. (Discriminating Monitoring Well Sensor BriteSensor ) Installation Instructions

FMP-ULS UNIVERSAL LIQUID SENSOR INSTALLATION GUIDE

Design Guide for Double Containment Pipes and Tanks. TraceTek Leak Detection and Location Systems

FMP-DVS. Monitoring Well Discriminating Vapor Sensor (BriteSensor ) Installation Instructions

Leak Detection and Location Systems

SECTION ph/orp Sensors

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

Using the DewTrak II Dew Point/ Humidity Transmitter

TLS-350R UST Monitoring and Leak Detection System With Automatic Business Reconciliation

ph COOLING TOWER CONTROLLER

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

Introduction to Flow Switch

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

PRODUCT LINE. Highest Quality, Best Service

Dew-Point Transmitters and Instruments

PUREFIRE PF-50, PF-80, PF-110 & PF-140 PF-50, PF-80, PF-110 & PF-140

Manual No: Revision: G. Sensor Products. Application Guide

FMP-DIS & FMP-EIS. Interstitial BriteSensor & Standard Sensor. Installation Instructions

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

AlarmLine Addressable Linear Heat Detector

POWERVAP - EX GENSER NOW AVAILABLE. High performance PTFE-sealings for all glass connectors. Fully automated rotary evaporators

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

Industrial Strength Leak Detection

LAKEWOOD INSTRUMENTS MODEL 353 ORP/MILLIVOLT CONTROLLER

631RF Amp Power Supply

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

Nirvana. Cycling Refrigerated Dryers

MAINTENANCE MADE EASY

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

BID-SPEC_INTEGRA_100 Rev. 0. Bid Specifications and General Description OPW SiteSentinel Integra 100 Automatic Tank Monitoring System

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Commercial and Light Industrial Fire Alarm Control Panel

Electronic Fuel Management Systems

FMP-DDS & FMP-DTS. Discriminating Dispenser Sump & Turbine Sump BriteSensor. Installation Instructions

5000TC Series Toroidal (Electrodeless) Conductivity Sensors. Specification. Overview. Features. Description /00 Page 1 of 8

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

TM Series. Induced Draft, Counter Flow Optional Accessories

Figure 1 DirectLine DL423 Sensor. Description, continued

FIND LEAKS BEFORE THEY FIND YOU. Leak Detection and Location Systems

INSTRUCTION MANUAL MODEL LDE 740. (Revised July 8, 2017)

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

/13 Price - $5.00

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Internal Use Only INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR

TraceTek Leak Detection

FMP-HIS AND FMP-HIS-U INSTALLATION GUIDE

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

STRIKE GUARD DELIVERS:

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Nirvana Cycling Refrigerated Dryers

Toroidal (Electrodeless) Conductivity Sensors Series 5000TC Specifications

Refrigerant Leak Detection Solutions

Figure 1 DirectLine DL423 Sensor. Description, continued

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

ZXSe Range Data Sheet

SiteSentinel itouch Console

Paragon. Induced Draft, Counter Flow Optional Accessories

OPTIMUM APPLIED SYSTEMS,

Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications

SENTRA Series Water Unit

REFRIGERANT RECOVERY DEVICES AND ACCESSORIES

Enhanced FOUNDATION Fieldbus Physical Layer Diagnostics with the DeltaV System

Complex alarming made simple

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features

Laundry Dosing Systems

PARAGON Commercial Refrigeration Controls

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

Specification for On-Line UPS Battery Monitoring and Data Management System

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

AS950 PORTABLE SAMPLERS

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

Hot Water Temperature Maintenance. HWAT System. Product Selection and Design Guide

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

PUREFIRE PF-850 & PF PF-850 & PF-1000 Heat Exchanger

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

SECTION ROTARY-SCREW WATER CHILLERS

fuel leak detection find leaks before they find you

A Better Boiler Just Got Better. Better Boilers. New Size Available. Express Setup. Load Status. User Setup. Installer Setup. Diagnostics.

Controllers. Instruction Manual WARNING

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

AS950 REFRIGERATED SAMPLERS

Remote Alarm Monitoring Alarm monitoring includes Global Remote Alarm Relay. Capabilities independent port can be used

Transcription:

ASAHI/AMERICA Leak Detection Basics Duo-Pro Engineered Double Containment PolyFlo PP and HDPE Double Containment ProLock TM PVC Double Containment World Class Quality Products and Service

Leak Detection Basics The Environmental Protection Agency (EPA) has directed underground transport of hazardous materials be protected from release into the environment in its Standard 40 CFR, Part 280 & 281. Our Duo-Pro, Poly-Flo, and Pro-Lock systems have been specifically engineered to exceed the piping system requirements of the EPA. However, an important additional aspect of the EPA requirement is the specification for leak detection systems in all buried systems. Pressurized systems must have automated leak detection, which are wired to shut-off valves in case a leak is detected, and drainage systems shall have at least a manual leak-detection system in place. Leak detection employment should also be considered in applications beyond those required by the EPA. In short, all double contained piping systems should have some form of leak detection. The issue then becomes how to properly select a means of leak detection. A basic leak detection decision making-matrix should include: - What EPA requirements, if any, apply - Is the system pressurized or drainage - Will the system be buried - If buried, is it under concrete or other difficult to access locations - Is the media transported over work stations/areas (safety concerns) - What are the potential safety hazards associated with media exposure - How important is location of the leak in terms of costs of potential repair - Is manual leak detection possible The decision making process may be simplified by review of the three main types of available leak detection systems; manual, low-point and continuous cable. The features and benefits of these systems will often dictate the application in which they are employed. Manual Leak Detection Manual leak detection for drainage applications is the simplest of the three available methods. It is accomplished by accessing the annular space generally at low points in a system with a valve, plug, or pipe riser to grade. The EPA mandates a leak detection process that involves the periodic manual inspection of the ports at least every 30 days.. Asahi/America offers customized patented Dogbone fittings that allow safe tapping into annular space without jeopardizing system integrity. Leak detection in the example shown, is accomplished by cycling the Asahi/America, Inc. PAGE 1 of 8

valve to the on position. The system integrity is ensured when no media is present after opening. A solid Dogbone can be utilized as a means of zoning a system. Systems with solid Dogbones minimize and compartmentalize area where a leak may occur. This design helps minimize potential costs to find and repair a leak. Manual Leak Detection Features, Benefits and Limitations - Simplified system engineering - Cost effective installation - Relies on manual (human) operation - Locates leaks within a zone or sector of a system - Does not accurately pinpoint leaks - Can be used with Duo-Pro, Poly-Flo, Fluid-Lok, or Pro-Lock Systems Electronic Low-Point Leak Detection Low-point leak detection is similar to manual leak detection but utilizes electronic sensors in the place of manual valves or plugs. A wide variety of low-point sensors are available with varying functionality. Selection of sensor type is often dependent upon transported media. The two most common sensors are conductivity probes and float switch adapters. Conductivity probes are triggered through the detection of all conductive liquids; water, acid, bases, chemicals, etc. Float switches are designed to detect liquid as their name implies. As liquid enters the float switch, a trigger arm raises to a point in which a relay is activated. Conductivity probes are generally best in piping systems in that they are triggered immediately upon contact with a liquid. Float Switches, on the other hand, are good for tank applications and activate after a certain level of liquid is reached. In piping systems, low-point sensors can be installed in configurations shown as shown to the right. An access tee is used in which the annular space drains into accesses the branch of the tee. It Asahi/America, Inc. PAGE 2 of 8

Adobe Systems LEAK DETECTION BASICS is then configured with a 90º elbows and a riser. A probe is generally suspended from the riser hanging directly over the low point of the fittings. Asahi/America offers a standard low point leak detection station by part number in its Dou-Pro, Poly-Flo, Fluid-Lok, and Pro-Lock systems. Risers are supplied with a 4ft height and shipped loose for field verification and installation. Electronic Low-Point Leak Detection Features, Benefits and Limitations - Simplified system engineering - Cost effective installation - Automated detection process for buried applications - Locates leaks within a zone or sector of a system - Probes are generally tied-in at a central alarm location - Can be used with Duo-Pro, Poly-Flo, Fluid-Lok, or Pro-Lock Systems Continuous Leak Detection Cable Continuous Leak Detection Sensing Cable offers the most accurate method of leak detection. Sensor Cable Systems are capable of locating multiple leaks without loss of accuracy and sensitivity. Leak locations can be determined to within Overbraid Polymer Coated Braid Wire Polymer Helix Spacer PF Insulated Center Conductor 5 feet of source. Sensor cables utilize Time Domain Reflectometry technology as the basis of leak detection. The technology operates similar to radar. Thousands of times each minute, safe energy pulses are sent out on the sensor cables. As these energy pulses travel down the cable, reflections are returned to the monitoring unit and a map of the reflected energy from the cable is stored in memory. The presence of liquids on the sensor cable, in sufficient quantities to wet the cable, will alter its electrical properties. This alteration will cause a change of the reflection at that location. The alteration is then used to determine the location of a potential leak to within five feet. In double contained piping systems, leak detection cable is installed by laying it on the bottom of the annular space between the carrier and containment piping. Pipe systems utilizing continuous cable should always specify pull rope requirements from system manufacturers. Pull ropes are used to facilitate pulling of detection cable during installation of piping systems. Care should be taken to ensure sufficient annular space exists in selected double contained piping systems for use with leak detection cable. Asahi/America, Inc. PAGE 3 of 8

Continuous Cable Leak Detection Features, Benefits and Limitations - Requires engineered location of access ports. - Requires sufficient annular space for pulling of cable; not compatible with Poly-Flo systems - Precise automated detection ideal for buried applications - Locates leaks within five feet of source - Most costly leak detection option - Cables are generally tied-in at a central alarm location - Can be used with Duo-Pro, Fluid-Lok, or Pro-Lock Systems Leak Detection Component Supply Program Asahi/America, with its strategic partner Perm-Alert, offers broad selection of leak detection components. The supply range of components is designed to facilitate specification, selection and installation of manual, low-point and continuous cable leak detection options. The following list pricing is offered as reference for the selection process. Asahi/America s Engineering Department is available to review your application process and assist with proper identification of required components. MANUAL & PROBE LEAK DETECTION OPTIONS Low-Point Leak Detection Stations Low-point stations are utilized in manual or sensor probe leak detection installations. Stations are generally installed in the low points of doublecontained systems. Solid Dogbones are recommended to compartmentalize sectors of low-point systems. Successful installations usually utilize solid Dogbones in the beginning and end of each specified sector as a means to isolate leaks and facilitate identifying location and repair. The Dogbone spacing or zone sizes are determined by customer or system engineer. The following table lists the standard, commonly installed low-point leak detection stations offered by Asahi/America. Low-points stations are provided with 4 riser, stub end, backing ring, EPDM gasket and blind flange. Stub End, backing ring, and blind flange are shipped loose for field elevation verification and installation. Asahi/America, Inc. PAGE 4 of 8

Dou-Pro Low-Point Stations Size Size Code Pro150 x 150 (5252) Pro150 x 45 (5337) Pro45 x 45 (5368) PVDF x Pro150 (6052) PVDF x Pro45 (6152) PVDF x PVDF (6252) 1x3 134 $ 1,035.70 N.A. N.A. $ 1,127.70 N.A. $ 3,306.00 2x4 420 $ 1,044.50 $ 885.80 N.A. $ 1,150.40 $ 1,006.30 $ 3,280.80 3x6 531 $ 1,406.80 $ 1,151.20 N.A. $ 1,514.10 $ 1,249.10 $ 3,897.40 4x8 583 $ 1,760.60 $ 1,356.80 $ 1,326.40 $ 1,792.60 $ 1,362.70 $ 4,737.60 6x10 627 $ 2,183.40 $ 1,844.40 $ 1,771.40 $ 2,301.40 $ 1,865.60 $ 6,754.00 8x12 660 $ 2,881.80 $ 2,208.20 $ 2,097.10 $ 3,099.40 $ 2,416.50 $ 9,276.80 10x14 702 $ 3,248.50 $ 2,680.20 $ 2,500.10 $ 3,709.00 $ 2,730.40 N.A. 12x16 690 N.A. N.A. $ 3,475.50 $ 5,761.10 $ 4,283.40 N.A. 14x18 710 N.A. N.A. N.A. N.A. N.A. N.A. 16x20 726 N.A. N.A. N.A. N.A. N.A. N.A. Part Numbers are selected by combining the type code with the size code Pro-Lock Low-Point Stations Containment Size Size Code PVC Sch 80 (6490) PVC Sch 40 (6773) CPVC Sch80 (6490) $ $ $ $ 3" (030) $ 636.40 $ 559.20 973.80 4" (040) $ 720.80 $ 646.40 1,272.70 6" (060) $ 868.40 $ 806.40 1,676.20 8" (080) $ 1,226.10 $ 1,151.10 2,274.30 Part Numbers are selected by combining the type code with the size code PVC & CPVC Low Point Stations are designed to have carrier pipe slip through fitting tee Poly-Flo Low-Point Stations Size Size Code Black PP - FLG (4280) Black HDPE - FLG (4480) Black PP - PLUG (4281) Black HDPE - PLUG (4481) 1x2 (249) $ 528.60 $ 470.70 $ 528.60 $ 470.70 2x3 (338) $ 737.30 $ 640.00 $ 737.30 $ 640.00 4x6 (532) $ 1,082.00 $ 918.00 $ 1,082.00 $ 918.00 Asahi/America, Inc. PAGE 5 of 8

PROBES AND SWITCH OPTIONS Series PWS Leak Detection Conductivity Probes The PWS probe detects all conductive liquids - water, acid, bases, chemicals, etc. Its solid-state, stainless steel construction allows it to be used in corrosive environments and reset quickly after removal from a liquid. The unique design of the PWS probe eliminates the need for external power at the probe. A PWS probe is available for the PAL-AT or LiquidWatch systems: 1.5" PROBE LEAD - The PWS probe for the PAL-AT can easily be connected into a cable "sensing string" providing increased utilization of the PAL-AT capabilities.62" - Each probe assembly includes a probe integrator with 60 feet (18m) of jumper cable to connect to the sensing string, 20 feet (6m) of lead wire to attach the probe to the probe integrator and a NEMA 4X junction box. ACTIVATION LEVEL =.62" PWS.25" PHL PROBE ASSEMBLY DETAIL - The PWS probe for LiquidWatch includes the probe adapter that is installed in the 20 feet (6m) long probe lead wire. Additional lead wire is used if necessary. PAL-AT NOTE: "-S probes must be connected in the first 5,000 feet (1,500m) of the sensor string. "-L" probes must be connected more than 5,000 feet (1,500m) from the PAL-AT panel. Series PWS Specification Probe Operating Temperature: 0 F to 180 F (-18 C to 80 C) Probe Length: 1.25" (32mm) Probe Diameter:.625" (16mm) Probe Lead Length: 20' (6m) Activation Level (min):.25" (6.4mm) Junction Box: (PAL-AT ONLY) NEMA 4X 10" x 8" x 4" Material: 304 Stainless Steel Ordering Information* For PAL-AT PWS-L Conductivity Probe Part Number: 4564200 PWS-S Conductivity Probe Part Number: 4564220 For LiquidWatch PWS-LW Conductivity Probe Part Number: 4891000 * = Please consult Asahi/America s Engineering Department for recommendations for additional required components (i.e. probe connectors, wires, cord grips ) Asahi/America, Inc. PAGE 6 of 8

Monitoring Units All electronic Leak Detection Systems require a monitoring unit to receive the input from probes or leak detection cable. Asahi/America offers the LiquidWatch and Pal-AT monitoring stations that are engineered to fulfill a wide range of application requirements: LiquidWatch Probe Systems LiquidWatch monitoring units have been engineered to meet a broad range of customer needs. The LiquidWatch Panel is modulare by design and can be configured with up to 64 probes and 16 alarm relays. The modular design allows for meeting current needs while allowing for future expansion of the system. The standard panel is supplied with a monitoring capacity of up to 8 discreet probes. Additional probe monitoring requirements are met by the addition of single or multiple expansion cards capable of monitoring up to 8 additional probes each. LiquidWatch Features - Sensing of organic liquid (hydrocarbons and solvents) or water within seconds of contact - Vapor or gases are ignored - Remote monitoring capability with a RS-232 interface and relays - Nema 4X enclosure - Up to 64 probes and 16 programmable alarm relays - Optional UL Listed with Class 1, Division1, Group C & D sensor circuits LiquidWatch Ordering Information* Asahi PN Ref Num Description 4890000 8027570 LiquidWatch (Std Location) 4895000 8027571 LiquidWatch (Int. Safe) 4892000 8027636 RPM-8 Probe Expansion Module Nema 4X 4892100 8027637 ORM-4 Relay Expansion Module w/ 1 RM-4 4892200 8027583 ORP-16 Relay Expansion Module w/ 1 RM-4 * = Please consult Asahi/America s Engineering Department for recommendations for additional required components (i.e. probe connectors, wires, cord grips ) Asahi/America, Inc. PAGE 7 of 8

Pal-At Leak Detection/Location Monitoring Units Pal-At Monitoring Systems are microprocessor based units capable of the continous monitoring of a sensor string for leaks, breaks and shorts. The units have sensing ranges of 2,000; 5,000; 10,000; or 15,000 feet per cable with up to 8 cables per panel. The alarm unit operates on the principle of pulsed energy reflection and maps the entire length of the sensor cable. A digitalized system map is stored in nonvolatile memory. Alarm panels provide continous indication that the sensor cable is being monitored. Pal-At Features - Can locate multiple leaks without loss of accuracy or sensitivity - Can differentiate between breaks and shorts vs. a wetted cable - Archives information with time and date - RS-232 serial port communications - Accepts both probes and cable sensors in one sensor string - One cable for all liquids or multiple cables for differentiation - AT40K and AT80K monitors up to eight separate cable strings when equipped with Cable Expansion Modules - U.L. Listed and FM Approved to provide intrinsically safe sensor cable output circuits for Class 1, Division 1, Groups C & D Hazardous Locations Pal At Ordering Information* Asahi PN Ref Num Description Max Cables Length Capacity 4552100 8027550 AT20C 1 2,000ft 4552200 8027555 AT50C 1 5,000ft 4552300 8027558 AT20K 2 5,000ft 4552400 8027563 AT40K 8 15,000ft** 4552500 8027610 AT80K 8 15,000ft** 4553100 8027610 XA50C Expansion Card AT40K 4553200 8027613 XA100C Expansion Card AT20K/80K * = Please consult Asahi/America s Engineering Department for recommendations for additional required components (i.e. probe connectors, wires, cord grips ) ** = Max length for hydrocarbons is 10,000ft Asahi/America, Inc. PAGE 8 of 8