Methods of leak detection. Alan Croucher, PFT Project Manager

Similar documents
OVERVIEW OF THE ELECTRIC RADIATORS RANGE

User Information Sheet 008 : 2010

A Comprehensive Approach to Leak Detection

TECHNICAL PUBLICATION

Managing a flood event

DISTRIBUTION OPERATIONS AND MAINTENANCE

Shell Canada Limited Hydrogen Sulphide (H2S) Release September 12, 2006

Critical Equipment Monitoring for Upstream Operations. Copyr i ght 2014 O SIs oft, LLC.

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Guide to Transmission Equipment Maintenance

1.1.0 Protocols for the response to fires involving MRI Machines

02 COOLING SYSTEM 02 COOLING SYSTEM COOLING SYSTEM INDEX. 1. General Specifications... 65

INNOVATION IN DISPENSE

Downhole video technology

TESTING STEAM TRAPS TO KEEP YOUR SYSTEM OPERATING EFFECTIVELY AND EFFICIENTLY

ALARMLINE ANALOGUE Linear Heat Detection System

Solving challenges. Artificial Lift Enhancing the Halliburton Product Line

Welcome to the International Gas Union s Inaugural International Safety Summit

Technical Bulletin Developed with Glow-worm

Smart Fire Prevention

property report Josh s House Living Key: enhancing prosperity and quality of living

6 th Pipeline Technology Conference 2011

Aquamax KF Oil Evaporator. User Manual

Sirius FS. Working towards a cleaner future

Schedule of Standard Charges for Distribution Services and Third Party Damage

Policy and Specification for the Interface with Independent Distribution Network Operators Installations

Ventura Field Rod Well Systems

FIBER-OPTIC SYSTEM FOR MONITORING EXTENDED OBJECTS «FOSM»

Critical Equipment Monitoring

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Oil and Gas Sector one stop solution provider

Ultra-Thin Flexible Heaters

Business Affiliate. Ireland s leading water control and leak detection specialists. Dublin Cork

ProMinent ProMus Hydraulic Diaphragm Metering Pumps

HEAT EXCHANGER FORMULAS & EXAMPLE

75-89 Wallis Road & 59 Berkshire Road, Hackney Wick, London, E9 5LN

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

Leak Detection Systems. Workshop UNECE / Berlin. Ted Smorenburg SABIC Pipelines Netherlands

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

Design & Use of Ground Based Pumps Guidance Document

Solar Water Heating. Design a solar water heating collector while learning heat science and building career skills.

SmartRad Planning Manual

Guidance for Stationary Refrigeration & Air-Conditioning

Space Saver. Installation and user manual SS3 SS5 SS7 SS9. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

FE1 Explosion-Proof Electric Air Heaters

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

Spa Control System OWNER S MANUAL

Aquarius - Spectrum. multi-layer acoustic water pipe monitoring solutions. Game changer in water network management

PRESENTS AQUADUCT AUTOMATED WATER-LEAK MONITORING SYSTEM A KINGPIN TECHNOLOGY

Grantham Southern Quadrant Link Road Environmental Statement

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Telecom Applications Management

Leak Detection. Ron Threlfall Manager, Leak Detection, Maintenance and Integration

Technologies for Leak Detection & Illegal Connections on Water Networks

Schedule of Standard Charges for Distribution Services and Third Party Damage

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

VAC-U-DRY VACUUM DEHYDRATOR

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

APPLICATION DATA SHEET

CLE SERIES Fluid heating for emergency eyewash stations

Welcome to the International Gas Union s Inaugural International Safety Summit

T.ex Single Gas Detector VISA

Solar station DKP 6-8 / DKP Installation and Service Manual C

Daikin VRV Systems Plugin VE2012 User Guide

Longline Heating. Contents. Introduction

FirePro ANNEX 1 MARINE MANUAL. Version 1,

ESSENTIAL REQUIREMENTS CHECK LIST

Serres. Suction Liner System

Carbon Film Installation Instructions

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Tortoise Protection Group June

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

The Worldwide Use of Fire Sprinklers

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

Managing Ex Asset Integrity

Evacuated Tube Solar Collector

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

THERMOFOCUS 01500A3 THERMOFOCUS

Ammonia. Background on ammonia as a refrigerant

Chapter 4: Fire Protection Systems

THE HEAT PUMP CHOICE OF PROFESSIONALS

SPILLSTOP ULTRA Hose Protection Overfill Prevention System

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

The Moors at Arne Project, Managing Coastal Change

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

SECURITY SERVICE LEVEL AGREEMENT

Nedap Cow Positioning with integrated Heat Detection and Health Monitoring

APPLICATION DATA SHEET

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

System Solutions. Efficient energy use, effective flash steam utilisation, and tailor-made customer solutions CHEMICAL THE STEAM SPECIALIST.

The Quality Connection. BETAflam Fire Resistant Safety Cables

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Transcription:

Methods of leak detection Alan Croucher, PFT Project Manager

Leak Response All UK Power Networks fluid filled cables are monitored by pressure alarm systems. An alarm from one of these systems may indicate a fluid loss from the cable and the potential presence of a leak. These alarms are monitored by our control centre, and our teams are on call 24 hour a day. Throughout UK Power Networks we have specialised field teams who maintain and repair our fluid filled network. The local team will be mobilised to investigate cause of the alarm and potential leak. The action taken by our field teams will be dependant of several factors: Environmental sensitivity of route Volume of fluid lost, ability to locate and urgency

Leak Response Once the severity of the leak has been ascertained the following actions may be taken: The circuit replenished with fluid To keep the cable integrity, to keep customers on supply Circuit pressure reduced To reduce leak rate Route patrol The leak could be a 3 rd party damage, or visible above ground or from ancillary equipment Cable de-energised If the leak rate is unsustainable, dependant on environmental impact and risk to customers Leak location undertaken Leak Locations undertaken in a timely manner, this can depend on several factors, primarily excavation restrictions and the availability of the circuit. Repairs made The condition of the cable will also be assed at this stage and feed back to our asset management systems

Methods of detection Traditionally, there have been two primary leak detection techniques for fluid filled cables: Cable Freezes Capenhurst hydraulic method Technology has now moved forward, and we now have a new method becoming available: Perflourocarbon Tracer Leak Location (PFT)

Cable freezes Cable freezes have been the mainstay for leak detection for many years. This method freezes the fluid in the cable, and by monitoring the pressure drop at each end of the circuit an indication can be given of the leaky section. There are limitations to this method The cable needs to be deenergised Unable to detect smaller leaks Multiple excavations required Disruption to the public and highways Cost Time

Capenhurst Hydraulic Method This leak location technology measures the flow of fluid through the cable, and by knowing the length and hydraulic resistance of the cable an estimation of the leak position can be found. The limitations with this method are: The cable needs to be deenergised Unable to find smaller leaks Accuracy of the results Cannot find multiple leaks

PFT Leak Location UK Power Networks is now using a new detection system developed by Wasson ECE. The detection technique is based upon introducing a small amount Perfluorocarbon Tracer (PFT) into the degassed cable fluid of the leaking cable, this tracer is then detectable by a mobile unit. The ultimate goal is to be able to detect fluid filled cable leaks faster, more cost effectively with reduced impact to the environment.

Perflurocarbon Tracers Perflourocarbons ( PFTs ) are a man made, non toxic, non flammable, non corrosive, chemically stable material which have a very low background levels. Uses to date for PFTs range from cable leak location, petroleum reservoir mapping, atmospheric testing and medical uses such as in artificial blood and eye surgery. UK Power Networks has undertaken extensive compatibility testing to ensure that there is no degradation or premature ageing of our assets. Further testing has also been carried out to ensure that there are no environmental, health or safety issues from using this material.

Leak Location System - Continued The Wasson Tracer Concentrator was developed by Wasson ece in conjunction with Con Edison NY and this is the 1 st unit commissioned in Europe.

Leak Location System - Continued With the Wasson Tracer concentrator it is possible to perform a initial Drive by location. This method will give a general indication of the leak s location, and with further bore hole sampling a near exact location of the leak position can be given.

Benefits of this Method of Leak Location This new method of cable leak location has the following benefits over existing technologies: Location of smaller volume leaks, typically around 50 litres/month. Once fully tagged, a leak on a circuit can potentially be found in less than 24 hours. Leaks can be located without making excavations. Leaks can be found without having to de-energise the cable, which reduces risk of customer s supplies being interrupted. The cost of leak location is greatly reduced.

Case study: West Weybridge - Walton No 2

Circuit details West Weybridge - Walton No2 33KV Three Core, Copper Conductor, 0.2sq inch, Fluid Filled Cable. Installed circa 1958. Hydraulic section length 2.1Km. Losing 80 Litres per day. History of leaks between joint positions.

Method Calculate the free fluid volume of the circuit. Replenish the cable fluid with PFT Tagged cable fluid. Hydraulic section fully tagged within 11 days. Initial Leak location undertaken after 5 days. Full survey undertaken after 11 days if not found beforehand

Overview

Results Three leak positions were found. Volume of leak discernable between locations. Leak Locations accurate to less than 1 metre. This cable has now been overlaid due to its poor condition.

Results

Results

Thank You Any Questions