Leak Detection - Application Note

Similar documents
Fast Detection and Localization of Small Ammonia Leaks Using Distributed Fiber Optic Sensors

PIPELINE LEAKAGE DETECTION

Praetorian Fibre Optic Sensing

Document Number March 23, 2016 Yokogawa Electric Corporation. Data Acquisition/Recorder. Data Acquisition and Monitoring. Paperless Recorder

Pipeline Integrity Monitoring with DAS

DETECTION AND LOCALIZATION OF MICRO AND MULTIPHASE LEAKAGES USING DISTRIBUTED FIBER OPTIC SENSING

Using HD-FOS for Characterizing Heat Exchangers. Case Study. Using HD-FOS for Characterizing Heat Exchangers

RaySense. Fiber Optic Distributed Vibration Sensing (DVS) for Pipeline Security and Leak Detection

RaySense. Fiber Optic Distributed Acoustic Sensing for Pipeline Security and Leak Detection

Asset Integrity Monitoring

Sensing Technology. A company of the BRUGG Group

Nanotechnology-Based Gas Sensors

APPLICATION FIELD INCLUDE:

Advancing Pipeline Safety

F&G detection system for LNG plants

Praetorian Fibre Optic Sensing

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES

Chapter 1. Introduction

WG Railway Security Protection System

OPTIBAR DP 7060 Supplementary Instructions

STRUCTURAL HEALTH MONITORING OF UNDERGROUND INFRASTRUCTURE

Phoenix Artificial Lift Downhole Monitoring. Improving artificial lift system performance

Optical Measurement Solutions. Fiber Bragg Grating Technology

Leak Detection. Ron Threlfall Manager, Leak Detection, Maintenance and Integration

Numerical Standards Listing

Emerson s Pervasive Sensing strategies enable plants to realize full potential of Industrial IoT

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

DETECTION AND LOCALIZATION OF MICRO-LEAKAGES USING DISTRIBUTED FIBER OPTIC SENSING

FIBER-OPTIC SYSTEM FOR MONITORING EXTENDED OBJECTS «FOSM»

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

HYDROCARBONENGINEERING June June 2015

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

GLD-30 Gas Leak Detector

RADIOLOGICAL SURVEILLANCE & ALARM MANAGEMENT SYSTEMS

Products and performance

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

Numerical Standards Listing

Tough as They Come. Ceramat. Retractable fittings for extreme conditions. With ceramic sealing to the process.

FUNCTIONAL SAFETY MANUAL

LINEAR HEAT SERIES FIBER OPTIC LINEAR HEAT DETECTION SYSTEM

Leak Detection Systems. Workshop UNECE / Berlin. Ted Smorenburg SABIC Pipelines Netherlands

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

SIL 2. Ultima X Series Gas Monitors CERTIFIED

TOTAL PERIMETER SOLUTION

WG Buried Cable Perimeter Detection System

Cast Line Heaters The Benefits of This Space Saving Electric Heater

Emergency shutdown systems. Procedures for bypassing ESD s

Submerged Pumps and Expanders with Magnetic Coupling for Hazardous Applications

Improvement of leakage monitoring in dikes by the use of distributed fiber optics sensors

Reinforced FBG Sensors Serve Demanding Applications

U L T R A S O N I C G A S L E A K D E T E C T O R

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

First Revision No. 20-NFPA [ Section No ]

Numerical Standards Listing

Gas Detection in Process Industry The Practical Approach

Safety Instrumented Systems

Skin-Effect Heat-Tracing System (STS)

Functional Safety Solutions

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

Temperature Monitoring and Leakage Detection for a Broad Portfolio of Industrial Assets

Dräger Flame 2100 Flame Detection

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

DASPOS A/S Gammel Klausdalsbrovej Herlev Denmark Tel.: website: DASPOS USA, Inc NE 116th Street, PMB

For Complete Fire and Gas Solutions

Vehicle Detection: How To Choose the Right Technology... 3

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

Proximity Detection & Collision Avoidance. Strata s solutions for surface, underground, and surface-to-underground

designed for rail 5000 Series

DAS fiber optic pipeline and powerline monitoring. Copyright OptaSense Ltd. 2019

Senscient s team has more than 150 years collective experience in gas. detection.

Mine Automation Technologies. know-how performance reliability

fuel leak detection find leaks before they find you

AUR300C. Advanced Ultraviolet Burner Controller

Reliability and field testing of distributed strain and temperature sensors

Proximity Detection for Underground Coal Mines. And other potentially volatile environments

OOH740-A9-Ex Multi-sensor fire detector

Presented at 6 th Pipeline Technology Conference Hannover, Germany April 4-5, 2011

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

Proximity Detection for Underground Coal Mines. And other potentially volatile environments

Thank You for Attending Our February Webinar:

Fluke 568 Ex Intrinsically Safe Infrared Thermometer

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

Soil-embedded distributed fiber-optic sensors for monitoring pipelines, dams, embankments, railways and roads endangered by soil movements

Meeting NFPA standards for

CombustionONE. Improving and Sustaining the Combustion Asset. Driven by the New Standards. Bulletin 53A90A01-01E-A

APPLICATION DATA SHEET

INTERFACE PRODUCTS SYSTEMS AND SOLUTIONS

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

Variable Temperature Options for Optical Experiments

Distributed Temperature Sensing

SUPREMATouch Modular Fire & Gas Detection System

Sieger fixed gas detection. Fixed protection from hazardous gas

Protecting Ethylene Process Facilities: A Review of Gas Detection Methods

FIBER-OPTIC SENSING TECHNOLOGIES

Transcription:

Leak Detection - Application Note THE SUREST WAY TO DETECT THE PRECISE LOCATION OF ANY LEAK IN HAZARDOUS SUBSTANCES PIPELINES AND PROVIDE TOTAL INTEGRITY THROUGHOUT YOUR PIPELINE NETWORK, ENSURING EFFICIENT, SAFE AND SECURE OPERATION Distributed Fiber Optic Sensors Leak Detection on the Continuous Length of the Pipeline Ethylene, Hydrogen, LPG, CO2, Ammonia, Oxygen Leak Detection Establishes a Clear Indication of the Leak and Location Suitable for Hazardous Zones Intrinsically Explosion Safe Long Range Measurement High Resolution High Reliability and Confidence Level Immune to Electromagnetic Interference Cryogenic Monitoring References Leak detection - hydrogen pipeline, Skotan S.A - Poland Leak detection - 57 km ethylene pipeline, Sasol Germany Leak detection - ammonia rack pipeline - fertilizer plant Yara - France

Over the past decades, several major industrial accidents led the chemical industries handling large quantities of dangerous substances. National regulation bodies are to reinforce the safety and prevention measures of their installations. Leakages of petrochemical products such as crude or refined oil, gas, LNG, ammonia or chlorine can be at the origin of toxic releases, which can have severe consequences on the installations as well as on the environment and nearby inhabitants. Industries are prompted to take all possible measures to reduce the occurrence and the consequences of such catastrophic events by implementing additional technical safety barriers in order to prevent or mitigate any potential danger on their key structures such as pipelines, storage facilities, transfer lines and ammonia reactor vessels. Pipeline leakages may have different origins, such as corrosion, fatigue, material flaws, shocks, abnormal temperatures, extreme pressures, or excessive deformations caused by ground movement. In the case of ammonia, leakages can be detected by the rapid drop of temperature due to the evaporation of the released liquid ammonia and its evaporation gases. These local thermal anomalies can be reliably detected by a fiber-optic distributed temperature sen-sing system able to detect temperature changes of the order of 1 C, with 1m spatial resolution and 10s response time. A fiber optic cable is installed under the ammonia pipeline along its whole length and is connected to a measurement system that can automatically detect temperature anomalies which are telltale of an ammonia leakage and generate an alert to initiate appropriate response actions on the affected pipeline section. Such a system has been developed by SMARTEC and permanently deployed at several industrial sites. costs and require the installation of a large number of units to achieve a good level of coverage and small leakage detection performance. Certain leak detection and inspection systems are used on a intermittent basis. If a leak occurs in between inspections, this will not be detected and critical safety levels may have been reached. LEAK DETECTION The basic principle of pipeline leakage detection through the use of distributed fiber optic sensing relies on a simple concept: when a leakage occurs at a specific location along the pipeline, the temperature distribution around the pipeline changes. This change in temperature is localized both in space (a few meters around the leakage location) and in time (the onset of the leak). The origin of the temperature disturbance around the pipeline depends on the type of pipeline and its surroundings. In a gas-carrying or liquefied gas-carrying pipeline, when a leak occurs at a location along the sensing line the Distributed System (DTS) system will detect a localized temperature drop or cold spot. The gaseous substance flowing through the pipeline is cooled down by the pressure release through the leaking pipe section and cools the pipe section and the surrounding area. It is also possible to observe a hot-spot when a leak occurs in a gas-carrying pipeline, for example, in a pipeline carrying water vapor. In the event of gaseous leak, the temperature drops due to the gas expansion (Joules Thomson effect). EXISTING TECHNOLOGY LIMITATIONS Often leaks are not detected until the amount of leakage is large. By this time significant environmental damage may already have occurred. Even when conventional system detect a leak, they are not able to pinpoint the location - leading to further delays and further expenses due to loss of product. Sniffers and thermal cameras typically have high maintenance As product leaks from a pipe it can cause temperature differentials due to differences with ambient conditions or Joules Thompson effect.

In a liquid-carrying pipeline, when a leak occurs at a location along the sensing line the DTS system will detect a localized temperature rise or hot spot. The liquid substance flowing through the pipeline is typically warmer than the structures adjacent the sensing line such that when the liquid escapes from the pipeline it tends to warm such structures. It is also possible to observe a cold-spot in the case of leaks from a liquid-carrying pipeline, for example, if the transported liquid is colder than the environment. TANK INSTALLATION In tanks the fiber is installed in the annulus of each double-wall storage tank to monitor for leaks through the inner wall. Fiber is also running in the conduits within the concrete slab bases to provide temperature distribution data to the heating control system. Lower risk of environmental damage Improved productivity BENEFITS AT OPERATIONAL LEVEL: Leaks will be detected quickly thus minimizing risk to operations personnel, neighbors and the environment. The optic signals used for the leak detection are extremely low power and incapable of igniting flammable gases making then suitable for use in hazardous zones. The sensing element is a passive fiber optic cable with a design life of over 30 years with minimal maintenance costs. Micro leaks can be detected, allowing action to be taken early before leaks grow larger and cause potentially major catastrophes. System is fully automated lowering operating costs with less risk of human error. It can interface with existing SCADA and industrial control system using standard proto-cols (electrical relays, OPC, Modbus). RELIABILITY & AVAILABILITY For mission-critical applications such as poisonous gas leak detection, several strategies can be used in order to ensure the reliability and high availability of such a system. Optical fibers are always installed inside a cable to protect them mechanically, while ensuring the minimum possible thermal isolation. Additional strategies for increasing reliability and availability include the following: Using a looped cable, where both ends of the sensing cable are connected to separate channels of the interrogator Using cables containing multiple optical fibers Using multiple cables along the same pipeline Using two interrogators connected to different fibers in the same cable or to different cables BENEFITS Benefits to the Health, Safety & Environment Manager: Improved safety of infrastructure and to personnel Enhanced system reliability through reduced downtime Redundant setup with two interrogators and looped fibers.

ATTS block diagram (ATTS in the shaded zone). CONFIDENCE LEVEL The Automated Trip Testing System (ATTS) is a device, fully independent of the data acquisition system, which can create an artificial leak along the sensing cable. In so doing, the correct response of the system and alarms can be verified. SIL 2 CERTIFICATION The Smartec s pipeline monitoring systems is certified as a Safety Integrity Level 2 (SIL 2) when used with the Automated Trip Testing System (ATTS). SYSTEM COMPONENTS Different cables are available for temperature sensing (normal and high temperatures). The cables are designed to be installed on the pipeline surface or in its vicinity. The Distributed () measurement instru-ments can measure sensors with a length of up to 2 x 45 km (upstream and downstream). Software packages are available for detecting leakages of gas, fluids and multiphase pipelines, to display and publish the mea-surement results in a userfriendly interface, and to generate warnings when abnormal conditions are detected. The Smartec s pipeline monitoring systems are based on a combination of sensing cables, measurement instruments and data processing software. GIS maps can be used to highlight precise locations of events.

Light Harsh+ Automated Trip Testing System External Optical Multiplexer Relay Alarm Module Switch Ordinary Cable Roctest Roctest is the leading developer, manufacturer and supplier of innovative sensing technologies based on vibrating wire and fiber optic sensors for geotechnical and structural instrumentation. We are featuring a complete line of conventional sensor-based solutions ranging from the ultra-robust traditional vibrating wire technology to state-of-the-art fiber-optic technology used for the measurement and monitoring of geotechnical projects and structural health monitoring (SHM) of critical assets such as: dams, tunnels, mines, buildings, bridges, nuclear power plants and many other structures too numerous to list. Roctest offers a wide range of pressuremeters, rock dilatometers, laboratory and in-situ testing equipment for soil and rock. Available Application Notes FO Leak Detection for Dams and Dikes Dam & Dike Instrumentation and Safety Monitoring Tunnel Instrumentation & Structural Health Monitoring Bridge Instrumentation & Structural Health Monitoring Building Instrumentation & Structural Health Monitoring Historical Monument Instrumentation Geotechnical and Structural Monitoring Nuclear Power Plant Instrumentation FO Movement Detection in Tunnels FO Leak Detection for Chemical Plants FO Leak Detection for Pipelines Storage Facility Instrumentation Cliff Instrumentation DiView Software Roctest Ltd, 680 Birch Street St Lambert, Quebec Canada J4P 2N3 Phone +1 450 465 1113 Fax. +1 450 465 1938 DOC: EAPN LEAK DETECTION CHEMICAL PLANTS_170130 Email info@roctest.com Web