CUSTOM PRODUCTS AND SERVICES GUIDE

Similar documents
MAS AIR SYSTEMS, LLC (724) mas-fan.com PRODUCTS AND SERVICES GUIDE

PRODUCT GUIDE THE NEW YORK BLOWER COMPANY

Introduction to Fans. The Basics of Fan Principles and Terminology

Centrifugal Fans, Non-Overloading, Backward Inclined

CML Northem Blower Inc. Air Movement Equipment

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

Selecting the Correct Fan

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Ducted Propeller. Airflow Volume

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

A. Codes and Standards that are Standard at the University:

SECTION (15833) - HVAC POWER VENTILATORS

Fans: Features and Analysis

Plenum Fans. Model HPA. Direct Drive

CASE HISTORY: RETROFIT OF COAL MILL EXHAUST FAN STUDY OF FAN PERFORMANCE AND EROSION

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Glossary of Terms Laboratory & Fume Exhaust Fans

Industrial Fans & Blowers

OUR EXPERTISE, YOUR AIR-MOVING SOLUTION CONCEPT. PROTOTYPE. IMPLEMENTATION. SUPPORT. ABSOLUTE RELIABILITY. VISIT US: LauFan.com

FAN TYPES CENTRIFUGAL FAN Forward Curve Centrifugal Fan

The Advantages of Choosing Centrifugal Fans

Modular Supply Make-Up Air Unit

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

DUST COLLECTORS & DOWNDRAFT TABLES. A division of BLOWERS

an ISO 9001 Company Bulletin PR-112

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

SECTION AIR HANDLING UNIT

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Direct Gas-Fired Make-Up Air

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

GreenJet Transfer Fans

ENGINEERING LETTER 4

SECTION STEAM CONDENSATE PUMPS

Twin City Fan & Blower

Advance Release September 2009

Indirect Gas-Fired Make-Up Air

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Practical Consideration of Noise from Fans

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y LS BARGE PUMP. Vertical high-flow pump

DAE Systems. Fan Selection Guide. Section 1: Terminology

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

MXI Mixed Flow Inline Fan

Modular Heating & Ventilating Unit Model IGX-HV

Varofoil Controllable Pitch in Motion Fans Compared to Variable Frequency Controlled Fans

Air Make-Up Units. Product Line Overview & Capabilities

SECTION AXIAL FANS

HOFFMAN & LAMSON ENGINEERED VACUUM SYSTEMS

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Optiline Fan Array. The optimum number of fans for every application. The Optimum in Sound Energy Size Redundancy Reliability.

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

KIC Air Curtains. Technical Guide

Multistage Centrifugal Blowers/ Exhausters CAST SERIES

Direct Fired Heater Model AD Specification

REVERSING DRUM MIXER

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Fan Arrays. White Paper. Energy Labs White Paper Series Volume 0412 Issue 001 April 2012 Rev. 0. Series

Welcome to Howden. Garden City Range of High Temperature Products

Bulletin FH05 FUME EXHAUST

Twin City Fan & Blower

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

Miniveyor. Tough Fans for Tough Jobs! NEW VAF Models now come with a Industry Leading 10 Year warranty upgrade on the fan body.

Centrifugal Blower. Backward/Aerofoil Curved.

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. ASME/ANSI B73.1 Chemical Process Pump

Power Flame Incorporated

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

DOCTOR DOCTOR. Masters of the Winds

RELIABLE SOLUTIONS FOR INDUSTRIAL APPLICATIONS ENGINEERED VACUUM SYSTEMS

Multistage Centrifugal Blowers

Multistage Centrifugal Blowers

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

Submittal Data Performance Data Electrical Data

An ISO 9001 : 2008 Certified Company SUBURBAN INDUSTRIAL WORKS (LESSEE)

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

AXPR Wall Mounted Axial Panel Fans

A. This Section includes air-handling units with coils for indoor installations.

Colloidal. Grouting. Equipment. Featuring ChemGrout s TurboMix Colloidal mixer. Heavy Construction. Marine/ Offshore. Mining & Tunneling.

AcoustiFlo Fans: Retrofit Solutions and Beyond

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

380 Series Multi-Stage Centrifugal Pumps

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

Marley Ultra Quiet Fan

1.1 This section applies to air handling units for HVAC Systems.

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

Mixing Technologies Solutions for Flue Gas Desulfurization

Construction Standards Page

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Transcription:

NEW YORK BLOWER COMPANY (800) 208.7918 nyb.com CUSTOM PRODUCTS AND SERVICES GUIDE

Why New York Blower Company The New York Blower Company is a full service fan manufacturer offering a complete array of centrifugal and axial products. These range from standard, predesigned fans to highly customized products. The New York Blower Company excels at designing and constructing fans for corrosive, abrasive and high temperature applications (beyond 1800 F.). In addition, we can modify fans to meet specific application needs such as zero leakage construction, abrupt temperature change, cyclical speed changes and more. Leading the Industry for Drawings and Fabrication Lead Times With over 125 years of design, engineering and manufacturing experience in both the fan and steel fabricating industries, New York Blower Company manufactures completely custom fans designed around specific application requirements. New York Blower Company has industry leading lead times for both drawings and fabrication when compared to the competition. Expansive Manufacturing Facilities The New York Blower Company has over 460,000 ft 2 of manufacturing floor space that is fully equipped to fulfill fabricating and machining requirements. New York Blower Company s AMCA accredited laboratory with six test chambers assists iin providing an unmatched combination of technology and manufacturing expertise in its products. New York Blower Company fan designs offer the highest aerodynamic efficiencies compatible with specific systems and gas-stream requirements. State of the art lasers allow New York Blower Company to cut steel accurately and cleanly. Plasma burning tables with ocy/acetylene have adjustable water levels and can cut carbon steel up to 4 thick. Air scribes and arc writers allow for accurate layout details on burned parts and coded materials. Inventory also includes a press brake, shears, heavy duty power rolls, dynamic balancers, laser alignment portable balancer, and sand blasting equipment along with all the related welding and forming equipment. The New York Blower Company follows a custom in-house Quality Control program proven efficient through years of experience. AWS D14.6 certified welders and documented weld procedures are used on all New York Blower Company fans, not just when specified by customers. NDT checks such as dye penetrant, mag particle, x-ray, ultrasonic and Helium spectrometer leak tests are routinely performed by both in-house personnel and independent testing services. Fan construction includes mild steel, high strength alloy steels, aluminum, 300 series stainless steels, Inconel, incoloy, hastalloy, titanium and other exotic alloys. Special coatings consist of baked phenolics, epoxys and rubber linings. Skilled in the repair and retrofitting of our competitor s equipment. New York Blower Company offers an extensive Field Service Department for fan startup and trouble-shooting. Our technicians have the flexibility to repair or rebuild any fan manufacturer s equipment. Our trained personnel can field measure a fan, or we can arrange to have a unit sent to our shop for duplication. Lab The New York Blower Company has an AMCA accredited laboratory and research center to ensure the company performs to the highest standards in product development and research including sound, air performance, vibration, finite element analysis, and speed-testing. 2 2016 New York Blower Company

Custom Engineered Fans Our fans are available in standard catalog sizes or as custom designed units. Each application is analyzed on its own performance and unique design requirements. Designs are based on computer analysis of wheel metallurgical stresses, shaft critical speed and bearing limitations. All units are custom built in accordance with customers specifications. Available in Arrangements #1, 2, 3, 4, 7, 8, 9 and 10 - all the standard design features of the industry plus custom sizes, DWDI, inlet boxes, cut-width construction, split housings, independent pedestals, liners, elevated temperatures, alloy construction, gas tight construction and more. Units can be designed to match any competitor s catalog dimensions or design construction. Design Features: Flows over 1,000,000 CFM/ 472 m³/sec Static pressures beyond 150 wg/ 37.4 kpa Centrifugal wheels beyond 150 in/ 3810 mm diameter - Radial Bladed fan models - Radial Tipped fan models - Backward Curved fan models - Flat Bladed Backward Inclined fan models - Airfoil fan model High Temperature Fans New York Blower Company s high temperature fans are available in both direct drive and belt driven centrifugal and axial designs. Design Features: Standard high temperature 1800 F/983 C fans Centrifugal and Axial designs - Shop insulated fans with riveted or welded cladding - Shop installed insulation pins for field cladding - Plug fans with backward inclined, axial, forward curve, paddle wheel or radial blade designs - Special alloy construction with shop welding certification - Water cooled packing gland seal - Gas purge seals - Gas tight construction - AMCA class C spark proof construction - High temperature louvered dampers - Backpressure (anti-thrust) blades Dual 250 HP drive RT radial tip fan for separating out debris from an industrial grinder. Carbon steel fan designed for a New York Blower Company customer as a repair and rebuild job. New York Blower Company 700 F Axial Fan used for an industrial furnance exhaust application. 3

Repair and Rebuild The New York Blower Company uses their experienced engineers, technicians and Field Service Department to assess and analyze any field issues associated with fan equipment. Fan assemblies can be quickly tested in the field or at New York Blower s AMCA accredited lab for a quick diagnosis of air, sound and vibration problems. Regardless of the original manufacturer, New York Blower Company can accommodate all repair, rebuild and retrofit needs. Service Features: Over four decades experience serving the fan repair and rebuild market. Ability to repair, modify and replace all fan manufacturer s designs and components. Ability to field measure difficult to replace components including wheels, cones, shafts and more. NDT (non-destructive) testing for safety and quality assurance. PMI (positive material identification) test capability for critical components. Relationships with skilled and New York Blower Company certified machine shops to salvage items including shafts, hubs and wheel components to reduce downtime and costs. Engineered solutions including modified liners, stiffeners, blade tips, metallurgical changes and fabricated inlets to accomodate changes in application requirements or to improve longevity of originally manufactured equipment. Rebuild We used competitor s fan assembly drawings and took field measurements to build the two fans with integral inlet boxes below. We upgraded both units to improve durability by including A514 scroll and cheek liners. The assemblies were installed without the need for any field modifications. Repair Induced draft fan located on dirty side of baghouse exhausting blast furnace. 82 diameter wheel with chromium carbide blade liners. Design Enhancements: Backspin devices Special guards Motor and drives including steam turbines, hydraulic motors and special couplings Modified inspection doors available with a variety of customer securing hardware Special motor pedestal platforms Custom wheel removal housing splits New York Blower designed and built dampers Radial inlet dampers Louvered outlet dampers Guillotine/isolation dampers (AVD) BEFORE AFTER 4

Products High Temperature Fans Axial Plug Fans (Series 900, Type AX & AXR ) Alloy constructions (300 series, Inco s, Hastelloy, RA, etc.) up to 1800 F. Available with gas tight construction and external air or water cooled shaft and shaft seals. For higher static pressure applications, see FC, Radial PW, BC and RT blade designs. Centrifugal Plug Fans (Type AcF, BC, FC, PLR, PW & RT ) Alloy constructions (300 series, Inco s, Hastelloy, RA, etc.) for temperatures up to 1800 F. Available with gas tight construction and external air or water cooled shaft and shaft seals. Available in Forward Curved, Radial, Backward Curved and Radial Tip wheel configurations. Tubeaxial and Vaneaxial (Series 950, Type AXT & AXV) Standard catalog style tubeaxial and vaneaxial fans for ambient air temperatures to 800 F. Housed Centrifugal Fans (Type AcF, BC, FC, PLR, PW & RT ) Standard catalog and customer style pedestal mount housed centrifugal fans for airstream conditions to 1800 F. Available with gas tight construction and external air or water cooled shaft and shaft seals. Available in Forward Curved, Radial, Backward Curved and Radial Tip wheel configurations. Backward Inclined Fans Airfoil Designs (Series 100, Type AcF & AF ) A complete line of high efficiency airfoil blade designs with a specific speed range - 12,000 to 80,000. Custom sizes from 12 to beyond 150 diameter. Optional solid nosepiece and/or liners for light dirt applications. Peak static efficiencies to 84%. Static pressure to 60 H 2 0. Volumes over 1,000,000 CFM. Non-overloading BHP curve. Backward Curve Fan (Series 200, Type BC ) A complete line of flat backward curve blade designs with a specific speed range - 10,000 to 70,000. Custom sizes from 12 to beyond 150 diameter. Single thickness airfoil blade profile with good wear resistance for use in dust laden applications. Peak static efficiencies to 83%. Static pressure to 70 H 2 0. Volumes over 1,000,000 CFM. Non-overloading BHP curve. Backward Inclined Fan (Series 300, Type BI & PLR ) A complete line of flat backward inclined blade designs with a specific speed range - 30,000 to 80,000. Custom sizes from 12 to beyond 120 diameter. Single thickness flat blade profile for dust laden applications can be made wear resistant. Peak static efficiencies to 78%. Static pressure to 35 H 2 0. Volumes over 1,000,000 CFM. Non-overloading BHP curve.

Products Radial Fans Radial Bladed Industrial Exhauster Fan (Series 500, Type AH, DH, LS, LSIE, MH, PW & RIM ) A standard line of Industrial Exhausters with air and material handling blade designs pre-engineered sizes from 12 to beyond 150 diameter. Peak static efficiencies over 70%. Three static pressure classes to 45 H 2 0. Custom designs for elevated temperatures to 1800 F. Units can be custom designed to match any competitor s catalog dimensions or design construction. Radial Bladed Fan (Series 600, Type RB ) A complete line of custom radial blade designs up to a specific speed of 35,000. Sizes from 8 to beyond 150 diameter. Peak static efficiencies of 75%. Static pressure to 150 H 2 0. Volumes from shut off (surge limiting designs) to over 700,000 CFM. Dirty applications special hard surface lining material available. Radial Tip Designs (Series 700, Type RT & RTS ) A complete line of custom radial blade designs up to a specific speed of 35,000 - sizes to beyond 150 diameter. Peak static efficiencies of 78%. Pressure to 80 H 2 0. Volumes to 900,000 CFM. Moderate to dirty applications special hard surface lining material available. Industries Served: Pulp & Paper, Utilities, Cement, Iron and Steel, Aluminum, Cement and Lime, Foundries, Chemical Plants, Air Pollution Control, Metals and Minerals, Petrochemical, Paper, Coal, Ethanol, Utilities, Power Generation, Mining, Water Treatment 6

Products Pressure Blower Fan (Series 400, Type PB364, PB368, BCPB & HPPB ) Custom designs available for elevated temperature, alloy construction and higher pressure/volume requirements than standard designs. Radial, Radial Tip and Backward Incline blade designs with improved Static Efficiencies from 68% to 78%. Static pressure range from 1 oz. to 60 oz. Volumes from 100 CFM to over 120,000 CFM at any required RPM. Standard designs available in Arr. #1, 4, 8, 9 and 10. Surge Limiting Pressure Blower Fan (Series 410, Type PBS364 & PBS368 ) Same design features available as the PB blower. Ability to operate at volumes approaching shutoff because of specific wheel/casing designs that minimize surge without the need for special design accessories or auxiliary equipment. Multistage Blower (Series 420, Type PB2S364 & PB2S368 ) Special two stage design blowers for high-pressure applications up to 150 PS on common shaft using single driver. Forward Curved Fans Forward Curve Fan (Series 800, Type FC ) Typical FC multi-blade Squirrel Cage design for low and high volume and high temperature applications. Standard sizes from 10 to 84. Temperatures range from ambient to 1800 F. Available in both centrifugal and plug fan designs. 7

Accessories Sound Attenuating Devices The New York Blower Company can supply silencers, blankets or enclosures for sound attenuating purposes. We manufacture our own enclosures and are able to custom fit the size of the enclosure to the installation. A variety of filter designs are available that provide attenuation and ensure clean air supply to the fan. Enclosures Enclosures are manufactured to fit the customer s size for applications where a silencer alone will not meet the customer s sound requirements. Sound transmission through fan housing and from motor can be controlled with an acoustical enclosure. Low temperature and relatively clean air applications. Acoustical Blankets, Silencers, Filters can be supplied by New York Blower Company. Special Applications In addition to manufacturing fans, New York Blower Company is known for providing customized fan components and solutions. For example, we can supply fans mounted on common bases with interconnecting ductwork to facilitate field installation.we have also supplied fans mounted inside tanks to ensure zero leakage from the system. If you require a product to move air, New York Blower Company can design and build it to your exact specifications. Ductwork New York Blower Company can supply interconnecting ductwork in a variety of shapes and sizes to help any system run efficiently. 8 Drives & Motors New York Blower Company can provide a variety of drives and flow control devices including: Motor Controllers Motor disconnects Motor starters Variable speed drives Magnetic couplings Motors Steam turbines Diesel motors Electric motors (NAME and IEC) Hydraulic motors Dampers (manual, electrical and pneumatically controlled) Louvered dampers Vortex dampers Isolation dampers

Services The New York Blower Company offers a comprehensive Field Service Department for fan trouble shooting. We can provide state of the art equipment for in-field alignment, balancing and analysis. Our field service personnel have years of field training combined with specialized schooling in the latest techniques and can assist diagnosing field related fan issues. Repair and Rebuild The New York Blower Company is highly skilled in the repairing, rebuilding, modifying and retrofitting of existing fan equipment. We take the performance criteria from the existing system to produce a fan that meets or exceeds the dimensional and performance requirements of the customer. Engineering Analysis Engineering experience plus ability combine for a theoretical and practical analysis of problems and solutions. We assist our customers with bearing analysis, stress analysis, shaft critical speed, resonant speed, thermal effect and other factors that can cause problems. Testing Fan assemblies are tested at New York Blower s AMCA accredited test lab. Flows to 130,000 CFM. Pressures to 100 SP. In addition, in-house prototype tests following the AMCA guidelines are routinely done on new designs or specific jobs for performance verification. Balancing The New York Blower Company can rebalance any manufacturer s wheel/shaft assemblies either in the field or in one of our facilities. Maintenance Preventative maintenance can help to extend the life of your equipment and avoid unexpected outages. Service technicians use certified testing methods to replace worn out parts to avoid costly repairs. When conducting maintenance, fans can be upgraded for higher capacity, improved efficiency or longer life with less erosion or corrosion. A New York Blower Company fan assembly being prepared for shipment. FEA Analysis of a repaired fan wheel. Testing is done to analyze problems with current designs and rebuild a more functional wheel. New York Blower Company replacement project which included replacing wheels, inlet pieces and portions of the housing. A New York Blower Company repair and rebuild project for a replacement wheel. This duplicate wheel has improved wear performance by adding chromium carbide liners. 9

Testing Capabilities The New York Blower Company can test any manufacturer s fan assembly for a variety of needs and requirements. Tests following AMCA guidelines are routinely done on new designs or specific jobs for performance sound and vibration verification. The following shows some of New York Blower Company s additional testing capabilities. Standard Testing Capacity: New York Blower Company fan being tested for air performance. All testing is in accordance with AMCA guidelines in an AMCA accredited laboratory. Critical Performance: New York Blower Company Fan packaged in a New York Blower Company manufactured gas tight tank for a vacuum furnace manufacturer. The system shown is being leak tested using a helium spectrometer by an independent third party. Non-Destructive Testing: Wheel hub being dye penetrant tested per AWS D14.6. Other test methods available include magnetic particle, X-ray and ultrasound. NDT inspection is done by New York Blower Company and independent third party inspectors as required by customer. Shop Testing: Customer specifications required shop testing of the 600 HP, Arr 7 fan prior to shipping. This unit is a 65 Backward Curve (BC) 1,800 RPM design and was successfully tested using a 450 KW diesel generator and 600 HP variable frequency drive system. Balancing Capabilities The New York Blower Company dynamic balances every fan shipped, from the smallest wheel sizes up to 150 diameter and 25,000 lbs, using three in-house balancing machines. A welder is working on fabricating a New York Blower Company wheel per customer specifications. This flat weld process allows the welder to rotate the wheel so welding is possible at every angle. Wheel and Shaft Assembly with Chromium Carbide Liners, SW, 1200 RPM, A514 Steel Construction. Shown being balanced on our large dynamic balancer with a capacity up to 140 diameter and 20,000 lb weight. 10

Laboratory Testing Capabilities The New York Blower s state of the art AMCA accredited laboratory that contains six airflow test chambers of various flow and tualpressure capabilities and two reverberant sound rooms. Lab Features include: Flows to 130,000 CFM 6 Airflow Test Chambers Pressures to 100 WC - 4 Figure 12 Horsepowers to 500 bhp - 2 Figure 15 Two Sound Rooms 15,000 Ft 3 44,000 Ft 3 Ability to operate 230/460/575v. Accommodates Simultaneous Air Tests Induced Draft and Forced Draft Test Capability Additional Testing Capabilities: Modal Analysis Impact (Bump) Testing Balancing and Vibration Tests to a Variety of International Standards NDE Weld Analysis Wheel Destruction/Deformation Testing Positive Material Identification/Verification (non-destructive) 2000 F Burnout Oven ASTM B117 Salt Fog Chamber Testing for Corrosion CAD/Coordinate Verification of Physical Shapes (such as airfoil blades, fan inlet cones) Computational Fluid Dynamics (CFD) Prototype/Product Evaluation Finite Element Analysis (FEA): New York Blower Company has in-house program to do engineering design analysis on wheels or complete fan assemblies. The program will calculate deflections due to external forces, corresponding stresses and predict natural frequencies. Shop Bump tests can be done to identify and verify actual resonance. 11

CUSTOM PRODUCTS AND SERVICES GUIDE The New York Blower Company 7660 Quincy Street, Willowbrook, IL 60527 (800) 208-7918 www.nyb.com mas-fan.com (724) 652-1367 mechanovent.com (219) 326-1767 Go to www.nyb.com to download more information. A complete list of available services, products, and fan designs can be viewed online. Pictures of field installations are also available. You can also call (800) 208-7918 or email nyb@nyb. com All information in this catalog has been provided to assist you in locating the fan that best meets your system requirements. Generally, there is more than one product line that will meet a particular flow and pressure requirement so we suggest you contact your local New York Blower Company representative to assist you in making the final selection.