Cooling the mid-size enclosure

Similar documents
A Primer on Selecting and Installing Active Thermal Management Products

Cooling the enclosed video projector

Active Thermal Management

Active Thermal Management. SEC-1 Installation Instructions

A: The last radiators might not be able to heat the rooms they serve on the coldest days of the year. Your system would be out of balance.

about your house Choosing a Dehumidifier

WINE COOLER. Model: WR 64-16

Combining Old and New Systems in Existing Buildings and Other Retrofit Tales. By Paul Jewett CFAA Technician Number 11

Cabinet Cooler Systems

How to Select an Industrial PC with I/O for a Wide Temperature Application

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

Environmental Specifications for Kaleidescape Components Engineering Bulletin

EVAPORATIVE COOLING How an Evaporative Cooler Works

WHY IS BUILDING SCIENCE IMPORTANT?

Using Fire Extinguishers. Leaders Guide and Quiz

Staying Independent. A Fall Prevention Checklist

English as a Second Language Podcast ESL Podcast 168 The Home Improvement Store

Section 9. Comparing Energy Consumption: More for Your Money. What Do You See? What Do You Think? Investigate. Learning Outcomes

Water in Buildings: Chemical-Free Clean Up & Resotration for Builders & Facility Managers Case Study #2 Duration: 4-6 hours

Section 1. Overview. The Kaleidescape Premiere System. System Components

Silencing The ALS-1306 Fans

CREATIVE INNOVATIONS IN HOME IMPROVEMENT & DESIGN

Solar Whiz - Frequently Asked Questions

What is home automation?

Before any Ohio winter, it's imperative you ensure your furnace is safe to run, energy-efficient, and ready for heavy, consistent use.

Home Fires Are Common, Deadly and Preventable

THE LOUDSPEAKERS. Precision Audio Loudspeaker Systems

COMMON SENSE APPROACH TO OPERATING DRY KILNS WHEN BOILER CAPACITY IS LIMITED. William Brubaker Wellons, Inc. Sherwood, Oregon.

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

Fun and G ames: M az es Perimeter and Area Beth Georg o ia Beth

INSTALLATION AND OPERATION GUIDE

CLEARING THE AIR by Jeremiah Wann, president and

Brivis IcebergTM. Australia s only sub-roof evaporative cooler

1. Select the group that best represents your connection with Eagle Hall.

Is It Always Cost-effective

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation

"USING FIRE EXTINGUISHERS"

OWNER S MANUAL HIGH EFFICIENCY VARIABLE SPEED GAS-FIRED FURNACES

Clearing the Air: Ventilation. RESNET Building Performance Conference San Diego, CA February 17 th, 2015

A Home Safety Checklist

Methods for controlling one and two pipe systems for comfort, even temperature distribution and energy savings.

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

WHITE PAPER.

Energy problems in small apartment buildings

Leader s Guide Marcom Group Ltd.

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

HYDROPONICS AND GREEN HOUSE CONTROLLER MODEL HGC-003 OWNER'S MANUAL FAN MAX TEMPERATURE LAMP DURATION FAN MAX HUMIDITY PUMP INTERVAL DECREASE

CHAPTER IV AIR DISTRIBUTION AND BALANCE

SIMPLE Furniture collection

Setting Speakers to Large or Small in Your Receiver or Pre/Pro

RM2604 & RM2804 Gas Controls

How Much Energy is Really Being Wasted?

Borroughs Standard Powder Coat Colors

PRECISION MADE TV LIFT SYSTEMS AND HIDDEN STORAGE SOLUTIONS RESIDENTIAL / COMMERCIAL / MARINE / HOSPITALITY / OEM

TABLE OF CONTENTS. Please record the following information for your records: Serial Number: Date of Purchase: Dealer Name: Dealer Address:

FIRE SAFETY PRACTICES AND PROCEDURES

Free Advice Free Quote Nationwide. Security Direct property protection. Home Security Buying Guide SECURITY DIRECT.

Wiremold. Evolution Series Boxes now available for ceilings. Evolution Series Ceiling Boxes

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

Cooling the Data Center

SunGrabber ABOVE GROUND - SOLAR POOL HEATER - INSTALLATION AND OPERATION MANUAL TABLE OF CONTENTS. Page 2 Page 2 Page 3 Page 4 & 5 Page 6

WHITE PAPER: Cooling Industrial Enclosures with Filter Fans

Oil Furnace USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

Energy Audit. This guide is for a 6 month Silver Award project. It is suitable for both group and individual volunteering.

DryAire DRYING CABINET

or call toll free in the USA INNOVATIVE CLEANING SOLUTIONS FOR THE TOUGHEST CLEANING PROBLEMS The Mission POSSIBLE Company

In accordance with the Department of Labor and Industry s statute , Subd. 11,

RADON LAZERWEB SERVICES

Ventilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2

Troubleshooting and Maintenance: Wood Stoves

Planning Questionnaire

Kenmore Elite Gas Clothes Dryer Troubleshooting

Installation Instructions

NC Mechanical Code. Land Use and Environmental Service Agency (Code Enforcement) Table of Contents

venting method will work for all pressure conveying systems, analyzing your available equipment, your material s characteristics, and your conveying c

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. How hydronic heating systems work

The ZappBug Room TM. Owner s Manual SAFE PROVEN EXTERMINATION. IMPORTANT NOTICE: Read Warnings Before Use!

Furniture Solutions for All Types of Industrial Labs

Global Design Competition. Global Design Competition

Land Use and Environmental Service Agency (Code Enforcement) Mechanical Q&A 2009

Selecting Fans and Determining Airflow for Grain Drying and Storage

Powerful Money Saving Ideas BROUGHT TO YOU BY TVA AND YOUR LOCAL POWER COMPANY

2012 UPC Chapter 5 Water Heaters RV

Milkweed Seed Separator

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

Cooling Systems for Georgia Dairy Cattle. Dr. John W. Worley, Extension Engineer

Homeowner s Guide: Being Energy Efficient

Installation Instructions

Assembly and Instruction Manual

Tempest /PowderPro. Installation Instructions. Heidelberg QM46DI X /98

Installation Instructions

HVAC Equipment Access Equipment Location

SAMPLE. added benefit of reduced operating costs during low demand periods, such as spring and fall.

Weather: Why do we have weather? Does it serve a purpose?

Installation Instructions

Assembly and Instruction Manual. #CR-2550 shown below

Natural Concept Landscape Co., Inc C SR9 SE Snohomish, WA Office-(360)

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

Transcription:

A white paper from Active Thermal Management The Trusted Name in Thermal Protection By Frank Federman, CEO Cooling the mid-size enclosure While there are situations in which you install basic systems in very small enclosures, such as the receiver and CD player in a bedroom nightstand, or a computer in a kitchen cabinet, and those involving elaborate systems in large enclosures, such as the 3 racks full of gear in a separate equipment room or closet, most installations involve the "mid-size" cabinet. "Mid-size" describes a range of enclosures from 10-12 cubic feet (2' wide x 2' deep x 2 ½' high) to 30-35 cubic feet (4' wide x 2' deep x 4' high). Construction is typically wood, whether the enclosure is a new cabinet built specifically to house audio/video components in a home or business environment, or an older piece of furniture designed for less technical purposes. In either case, the cabinet may have one or more shelves to hold equipment, while the wider ones may have both vertical dividers and shelves. Installed in existing homes, these cabinets may simply be placed against a wall, exposing one or both sides. The back may be several inches from the closest wall, greatly facilitating ventilation. In newer homes, an alcove is frequently created in the family room into which an enclosure can be slid, or the enclosure is "built-in", a permanent part of the room's structure. In commercial situations, a credenza in a training room may be permanently located against a wall. In these cases, one or both sides may not be available for powered or passive ventilation openings. One feature common to stand-alone and built-in enclosures is the presence of a door, ensuring that the audio and video components inside the cabinet will have very little (meaning "no") ventilation unless the designer or installer "makes it happen". This is usually not difficult; our company, Active Thermal Management, has over 25 devices and systems that can quietly ventilate these cabinets, as well as the very large and very small. Working with designers and installers, we suggest products to prevent (more often, stop) equipment overheating. It will come as no surprise to the reader that while we can usually solve the technical issues of CFM's, BTU's, and db's in a few minutes by telephone or e- mail, satisfying the esthetic considerations ("you want to put a hole WHERE???") can be considerably more difficult, and certainly more time-consuming. In almost all cases, by Active Thermal Management Cooling the mid-size enclosure Page 1 of 7

describing the damage that is being done to the client's expensive equipment by allowing it to overheat, compromises can be reached that will keep all parties, if not happy, at least cool - pun intended. We have more than one A/V dealer who will not install a system UNLESS the owner agrees that ventilation is essential and MUST be provided. Those dealers feel, with justification, that avoiding the nuisance service calls, shortened equipment life, and general dissatisfaction that overheating can cause is worth the "extra sell" up front. The owner is paying a designer or systems integrator at least partly for his expertise; both the owner and the installing company benefit when systems run cool. So we've described the cabinets, and we agree we need ventilation. How do we get it? How do we keep both the electronics - and the client - cool? At Active Thermal Management, we talk to installers every day about solving these problems. After many years of experience, we note that, while there are exceptions, the great majority of "mid-size cabinet venting" problems can be solved with just a few basic techniques. There's no math involved; no knowledge of thermodynamics needed. Most home theater systems are comprised of similar types of equipment, and generate similar amounts of heat; we've chosen fans and designed control systems to remove the BTU's generated. We have developed a group of fully automatic cooling products under the family name of "System 2". With four members, there's a good chance that one of the System 2 family will cool the mid-size enclosure you're working with. Whether the equipment is rackmounted or sitting on shelves, or just piled in a heap, the original System 2, the Kit, the 2+2 Kit, or the Rack-Mount will sense temperature rise, turn the fans on slowly, then gradually speed them up if the temperature continues to rise. When the equipment is turned off, the fans will gradually slow down as the equipment cools, turning off completely as the enclosure approaches room temperature. A few words about the individual "family members", then on to "so where do I put them?" The original System 2 consists of two fans mounted (in exhaust mode) to a 1/8" black mounting plate, along with the electronic controller. It's one piece (plus a "wallwart"), and, if there's enough cabinet wall to hold it (around 16" x 8"), very easy to install. But.sometimes space is tight, so The System 2 Kit is the same product, less the mounting plate. Completely modular, you can install the fans separately, as described later. A few more holes to drill, but much more flexibility. The System 2+2 (Kit) is the System 2 Kit, but supplied with four fans, for somewhat larger heat loads, or cabinets on the large side of "mid-size". Active Thermal Management Cooling the mid-size enclosure Page 2 of 7

For rack-mounted systems, the Rack-Mount System 2 is just that; 3 fans + electronics, pre-mounted to a 3-U black powder-coated panel. Easily mounted on the front OR rear rails, it will quietly pull cooling air through the rack. The fans are high quality 4.7" (120mm), 1" (25mm) thick "muffin" type, which never turn faster than 2/3 of their normal speed. A word about the fan drive electronics: it's a circuit that delivers a pulse-width-modulated signal to the fans. At room temperature, the duty cycle of the output is 0%, increasing to 100% as temperature rises. There are two thermistors to sense equipment (or air) temperature; whichever one is hotter controls the fans. Usually, one is mounted on whichever piece of equipment run hottest when the system is ON; the other, to the piece of equipment that runs hottest when the system is OFF. (TiVo s, hi-def satellite receivers, etc.) Fans can be added to basic System 2 kits if cooling needs increase, up to a maximum of two thermistors and four fans. We have found that one or another model of the System 2 family is almost always the most cost-effective (and quietest) way to ventilate the mid-size enclosure. Question: OK - I've got my fans; where do I put them so they'll work best? Answer: In general, the best solutions result in cool room air entering an enclosure at the bottom front, and heated air leaving at the top rear. Wider enclosures are best cooled by adding a sideward air movement; air should enter bottom front left (or right), and exit top rear right (or left). Complex ( but as unobstructed as possible) air paths remove the most heat, and minimize the possibility of trapped pockets of stagnant air. The simplest cases are cabinets whose backs are several inches from the closest wall. If there's one large compartment, put a fan blowing room air IN in a lower corner, and one blowing OUT in the diagonally opposite upper corner. (See figure 1.) If there s more than one compartment to be cooled, either use 4 fans (2 per compartment) or, for modest heat loads in two adjacent compartments, put an intake fan in a lower corner, and one blowing OUT in the diagonally opposite upper corner in the other compartment. One large or several smaller openings in the divider between the compartments will allow the free passage of the air as it flows from the inlet to the exhaust point. Similarly, large (4" - 5" diameter) openings in shelves allow the vertical passage of air. By making sizable openings in shelves directly beneath the A/V components, the air will be directed at the component on the shelf. For this reason, it is best to have shelves run full depth in the cabinet, i.e., not cut short as is sometimes done to provide ventilation and facilitate cabling. This just routes the air up behind the component, cooling it inefficiently if at all. Better to make small openings or notches for wires, and force the air to go through large holes under the components. Any Active Thermal Management Cooling the mid-size enclosure Page 3 of 7

large openings that allow air to bypass the A/V components should be blocked, if possible. If the cabinet back is up against an interior wall, it is frequently possible to cut through the wall and move cool air from (and heated air to) the room on the other side of the wall. (But not a garage; fire codes generally prohibit openings between living spaces and garages.) Exhaust fan or opening Figure 1 Intake fan or opening A note -- It is not necessary to use fans at BOTH the intake and exhaust points. Although 2 or 4 fans will probably be necessary to generate enough air flow to provide the desired cooling, it is possible to either use all fans as intake devices, and have simple openings for exhaust, OR use all fans as exhaust devices, with simple openings for air intakes. These techniques are useful in situations as shown in figure 2. Active Thermal Management Cooling the mid-size enclosure Page 4 of 7

Exhaust fan Figure 2 Passive air intake Here, instead of fan-sized holes for air intakes, rectangular openings (usually between ¾" wide by 6" long and 1" wide by 8" long) immediately behind the doors provide adequate amounts of air to flow into the cabinet through slots that are invisible when the doors are closed. (We assume a recessed "kick panel", frequently found in A/V cabinets; when the cabinet doesn't have a recessed base, slots can be routed into the front or sides of the base, below the cabinet floor, and slots or round holes cut in the floor of the cabinet to allow the air to flow up into the cabinet.) Figure 3 shows a cabinet in which venting through the rear is not possible. The back panel of the cabinet is up against the wall, and cannot be moved away. The wall may be an outside wall, or the room behind the cabinet may be one in which the owners don't want openings made. Intake fan Exhaust fan Figure 3 Active Thermal Management Cooling the mid-size enclosure Page 5 of 7

Similar to the "rear venting" example discussed earlier, we've moved the openings for both intake and exhaust from the rear panel to the sides. Note that the air is moving in all three dimensions; down-to-up, side-to-side, and front-to-back. Will owners (and their interior designers) be thrilled at the thought of making holes in the sides of their cabinets? No. Will they let you do it? Yes (usually), IF they understand the necessity of ventilation, IF they want their expensive home theater equipment to work properly, and IF they want it to do so for a long time.. The appearance of visible openings can be improved by the use of routed slots (a job for a cabinet maker, not an installer!) or high-quality wood grilles that can be painted or stained to match the cabinetry. Active Thermal Management can supply very high quality grilles in 26 species of wood, and a variety of metals. A few general notes: Do NOT expect air to move through fabric, no matter how "open" the weave. Slow-turning fans, used to minimize noise, don't have the power to force air through cloth, and, even if they could, the dust present in the air in the cleanest of houses would soon clog the weave, discoloring the cloth and stopping all air flow. Feel free to "mix & match" ideas seen here. Use your imagination and you can almost always find a way to bring fresh air into a cabinet low, and, preferably, in front. Similarly, a way can almost always be found to exhaust heated air high, and, preferably, towards the rear of the cabinet. Make any openings the air has to pass through as generous as possible. The goal is a "free-breathing" enclosure, in which relatively large amounts of air can move slowly, cooling the equipment within the cabinet without noise. There are many installations that consist of two equipment cabinets flanking a video display. In many cases, the video display is located forward in a central cabinet, and has open space behind it. If the display is not sealed into the cabinet, i.e., air is free to move past it, you can often vent the component cabinets "sideways" into the space behind the display, allowing the air from the side cabinets to escape into the room from behind the display. (The temperature of the air moving through a well-ventilated cabinet typically rises only a few degrees above room temperature; temperatures climb very high only when there is no air movement. For this reason, it is generally safe to exhaust heated air near other components.) Fresh air can be brought into each of the side cabinets using methods outlined earlier. Active Thermal Management Cooling the mid-size enclosure Page 6 of 7

Contact Active Thermal Management at (661) 294-7999 M-F, 8:00 5:00 PT for the name of your closest distributor, for more information on the products mentioned above, or to request a catalog showing our many other quiet cooling products. We manufacture a complete line of equipment and enclosure coolers designed to make the designers' and installers' jobs easier. See us on the Web and download our other white papers at www.activethermal.com. Active Thermal Management Cooling the mid-size enclosure Page 7 of 7