Tempest Projector Enclosures in Hot and Humid Outdoor Environments

Similar documents
Cyclone. Outdoor. Projector Enclosures 20-45K. Fourth eneration. Projector Enclosures

Cyclone. Outdoor. Projector Enclosures 20-45K. Fourth eneration. Projector Enclosures

Cyclone. Outdoor. Projector Enclosures 20-45K. Fourth eneration. Projector Enclosures

Ambient (ºF) Temperature Rise Above

Cyclone. Outdoor. Projector Enclosures 20-45K. Fourth eneration. Projector Enclosures

Hunting the Mighty Milliwatt The next Technology Step

Hunting the Mighty Milliwatt- The next Technology Step

THUNDER Lighting Enclosures. Any Light. Anywhere.

Cabinet Cooler Systems

Cold comfort: The rising use (and cost) of air conditioning in B.C. Report. July 2018 BCH18-712

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

HVAC considerations for lamp and laser projectors in cinema

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T53 Model

T-Series Air Conditioner T20 Model

Guide To Troubleshooting INEFFICIENT COOLING FANS

APC APPLICATION NOTE #109

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

HOW IT RELATES TO PERFORMANCE IN REFRIGERATED COMPRESSED AIR DRYERS

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

EXCELSIOR SINHGAD COLLEGE OF ENGINEERING, PUNE PAPER PRESENTATION

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

COOLING FOR ELECTRONIC PROCESS CONTROL SYSTEMS IN HOSTILE FACTORY ENVIRONMENTS

Enclosure Temperature Control

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

WHITE PAPER: Cooling Industrial Enclosures with Filter Fans

Enclosure Temperature Control

EqUIPMENT LAYOUT MANUAL

CS027 User Instructions

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

Equipment Layout Manual. For Cooling Towers, Evaporative Condensers & Closed Circuit Coolers

Instructions manual DEHUMID HP50

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

Maluna Unhinged vs Yeti Tundra Thermal Performance Comparison January 2017

Motion Sensor. Specifications

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Museum Archive Dehumidification in Hot & Humid Climates

User Manual. Tornado Moving Light Enclosures. User Manual and Installation Guide.

Connect North and South Korean Separated Families Higher Comfort Lower Energy

Dual Column Dehydrating Breather Manual

TESTS OF ADSIL COATING

Instruction Guide: Thermostat Operation

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Chapter 5 Inspection and maintenance

Installation and Maintenance Manual Please retain this manual for future reference.

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Chapter 10. Passive Cooling Contents

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

ENERGY EFFICIENCY BRIEF REPORT

Ultrasonic Aromatherapy Diffuser with Color Changing LED Lights Instruction Manual and Warranty Information - Read and Save These Instructions.

WHAT YOU DON T SEE CAN HURT YOU. KenkoAir Purifier

Instruction Manual CHHC-1

HYDROPONICS AND GREEN HOUSE CONTROLLER MODEL HGC-003 OWNER'S MANUAL FAN MAX TEMPERATURE LAMP DURATION FAN MAX HUMIDITY PUMP INTERVAL DECREASE

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX (951) Growmate Growmate Plus

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

ARCHITECTURAL DIMMING PANEL - MAIN/SECONDARY

OPENING AN ENCLOSURE and blowing a fan on heat sensitive components

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

North Dakota State University Laser Safety

Risk Assessment and Control Measures for Household Hot Water Systems

Model: Touch-RF. 1 Wireless Series

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

C-Stat 17-ZW User Instructions

DS-8C RAIN/SNOW SENSOR CONTROLLER INSTALLATION INSTRUCTIONS

Orion ionplus 2111LL low-level sodium monitor. The next generation in sodium protection. Analyze Detect Measure Control

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

MacroAir AirElite HVLS Fans

Getting Rid of Scale. Nortec RS Series Steam humidifier with patented scale management. Humidification and Evaporative Cooling

TESTIMONY OF MARK CONNELLY

User Manual Whispr G4 Revision 01.0 November 2016 Tempest Lighting, Inc.

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

Air Conditioner Performance Upgrade

User s Manual

TCW 2000 Ice liner refrigerator and freezer PIJ

Important Notes: Please read carefully before installing your refrigerator.

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

MeacoCool MC Series Portable Air Conditioner

Comparative analysis of power supply single speed air mover and an entire electronics enclosure system fan

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

A FRESH CLIMATE FOR FOOD TECHNOLOGY

Embassy PoolCo A DIVISION OF HOFFINGER INDUSTRIES, INC. Warranty. Sun Cloud Portable Furnace Three years. Safety

Hades 2. Digital Recycle and Lighting Timer with High Temp Shut-Off Instruction Manual. Notes: 1 Square = Foot/Feet

Press Release. How can the efficiency of the dryer section be increased? Dryer Section All Paper Grades. Heimbach wherever paper is made.

PURIFICATION SOLUTIONS. R-Series 1. cycling refrigeration compressed air dryers flow capacity: scfm ( Nm 3 /hr)

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

Portable Air Conditioner User Manual

PIPELINE LEAKAGE DETECTION

Seven Breakthrough Advantages of New Steam Valve Technology

ToThePOINT. Best Practices. Best Practice No. 1: Have your boiler inspected regularly by an authorized inspection agency. LOSS CONTROL SERVICES

Figure 1: Rice solar drier

Transcription:

Tempest Projector Enclosures in Hot and Humid Outdoor Environments 1/18/2017 1

January 18 th, 2017 Tempest Projector Enclosures in Hot and Humid Outdoor Environments Tempest works very hard to continually improve its products to meet the most challenging demands placed on them. In recent months we have experienced a number of problems in various locations and applications, and it is important to review and learn from these experiences to assure our customers that their confidence in Tempest is not misplaced, particularly since at the time of writing we are introducing a major new enclosure product line and some important cooling innovations. Recent Trends As projector manufacturers strive for ever more lumens in ever-smaller packages, projector thermal management design has become an increasingly key success factor in their design process. This is even more the case as we see the beginning of a trend to laser phosphor light sources, which have advantages in ownership cost and service intervals, but which are actually less efficient at turning power into projected light. All this has led manufacturers of some of the highest power projectors on the market to lower their environmental temperature limits for example the 45,000 lumen Barco HDQ has a 35 C limit, and Christie s Boxer is 40 C. While the projector manufacturers may admit privately that these limits may safely be exceeded for some small portion of the total projector duty cycle, projector control software has also become more aggressive at policing these limits, causing owners to be more sensitive in adhering to them. This has obvious consequences for outdoor installations in enclosures that have historically depended on circulating large volumes of outside air to remove lamp exhaust air and radiated heat from the projector housing, without the use of active cooling. With a typical ΔT of 2-5 C between outside air 2

temperature and projector inlet temp, it is obvious that a projector with a 35C top intake limit will start crying foul in an enclosure with, say a 3C ΔT and an outside temperature of 34 C. Daytime and Showtime Temperature Management It is important to distinguish between temperature management during show conditions, generally after sunset, with somewhat lower outside temperatures, and daytime, possibly under direct sun, but with the projector in standby mode, and not contributing to enclosure heating by more than a few watts in most cases. Showtime Clearly, the imperative must be to maintain an acceptable operating temperature for the projector at showtime, within its safe operating temperature range, when its lamp is running. From a system design standpoint this means determining the likely worst case outside temperature for the desired location, at the desired time of day/night. When compared with the projector s environmental limits, the enclosure specifier may then choose from a range of strategies to maintain such safe operating temperatures for the foreseeable conditions. It may be that exceptionally high temperatures may occur from time to time, and they may be harder to predict. Strategies may include: 1. Relying on the projector to limit its power output (and therefore heat load) when it reaches its safe upper temp limit (some projectors will do this automatically, others may require help ) 2. Providing additional cooling headroom in the enclosure design. 3. Overriding the projector top temp warnings, based on a duty cycle calculation that x% of projector lifetime at y% overtemp will not significantly harm the equipment. Tempest AC Assist To this end, Tempest recently installed our first (beta) AC Assist installation in Dubai, in an installation with fourteen 45,000 lumen Barco HDQ projectors (environmental limit 35C/80%RH), running in night time temperatures of 35-38C, and very high humidity in the Summer months. 3

AC Assist Challenges and Solutions Tempest has long taken the position that AC-based active cooling is too dangerous to use in projector enclosures, for two main reasons: Cold-shock in a warm environment the introduction of cold air may cause lamp shock and stress electronic circuits Condensation We have seen dramatic levels of condensation in situations where cooled air (say 19-20C) is introduced into an enclosure in a much warmer environment. System designers must be aware that such condensation, while most visible on, say the inside of the enclosure port glass, will be present on any similar surface inside the enclosure, when the temperature and RH levels are high. Over time this will lead to corrosion and/or mineral deposit buildups throughout the enclosure, and the projector it contains. The keys here are to use AC Assist only with a built-in dehumidifier, which lowers the overall RH at the same time as cooling the air, and critically only when the projector is running. Cooler sizing: there may be more to learn on this, but at this stage it appears that a spot cooler rating of 50-60% the btu/hr rating of the projector is an optimum level to blend with hot (35-40C) inlet air and reduce internal temps by approximately 10C. Thus a Christie Boxer (12,500btu) would require 6-7,000 btu of spot cooler capacity. The Tempest AC Assist solution is to use a 16,000btu rated cooler, as follows: o Barco HDQ/Christie Roadie one dedicated cooler per projector o Christie Boxer/Barco HDF one cooler to 2-3 projectors o Christie M-Series/Barco RLM one cooler to 4 projectors (see illustration) 4

There are a number of Spot Coolers on the market that may be modified to suit this application, though none that is available with an outdoor rating and the necessary control systems out of the box. Tempest s solution takes the best unit we can find, with a number of important modifications: Weatherproofing Tempest adds cowls and gaskets to protect the AC Assist units from rain. Note that, while effective, this is not the same as a UL50 or NEMA3x certification. Control Tempest is developing an AC Assist controller, as a plug-in to its new DEC4 enclosure controller, that will switch on the AC Assist unit only in the desired circumstances (projector lamps are on, inlet temp is approaching or above projector inlet temp limit). Blending the AC Assist unit feeds cooled (and dehumidified) air into a hose adapter on the enclosure filter clamp, so the cooled air passes through the same HEPA filter as outside air, with which it is effectively blended, preventing cold shock. The combined temperature may be reduced by as much as 12 C below prevailing outside air temperature in this way. During the day, the enclosure may pull outside air through as required without disconnecting the AC Assist unit. 5

Projector Max By adopting these strategies, AC Assist is now a practical solution in situations where showtime outside temperatures approach or exceed projector environmental limits. The following chart may be helpful in developing appropriate cooling strategies for specific locations and projectors: Ambient C 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 45 44 43 42 41 40 39 38 37 36 35 Note that the ambient temperatures shown here are showtime, not daytime temps. 6

Daytime Temperature Control Tempest enclosures with DEC3.x and DEC4 controllers (that means everything shipped since 2011 up to the present time) employ Tempest s Goldilocks operating System (GOS, patents pending), to control temperature and humidity, WHEN THE PROJECTOR LAMPS ARE OFF. None of these settings has any bearing at all when the projector is running with its lamp(s) on. GOS does its best to maintain a Goldilocks zone temperature and humidity range, with temperatures between UPPER and LOWER temp settings, and relative humidity below the RH setting. GOS dynamically converts RH% into absolute humidity, calculates risk of condensation, and, if present, calculates a (higher) temperature at which the risk is negated, then uses the enclosure heaters to raise the internal temperature to that target level. IT IS IMPORTANT TO UNDERSTAND THAT HEATERS ARE NOT USED IF EITHER (A) THE PROJECTOR LAMP IS ON, OR (B) ACTUAL INTERNAL TEMP IS HIGHER THAN THE DEC S UPPER TEMP SETTING. This is normally fine, since high risk condensation periods are usually in the early hours of the morning, when neither condition pertains (and nobody is usually around to see the condensation if the DEC were inoperative) This system has been working very well for several years in many climate types. 7

Over-Aggressive User Settings Some users have attempted to correct overheating by setting UPPER TEMP limits too LOW. This is understandable, but misguided. Firstly, these settings have NO EFFECT when the projector is running, so setting an UPPER TEMP of, say 30C, has NOTHING TO DO with the projector s operating environmental limit of, say 35C. The UPPER TEMP setting is merely the temp at which the enclosure fans will start to blow (with projector lamp off), to prevent the enclosure overheating under hot sun. But it also has the effect of preventing the heaters from operating to combat condensation. So in warm and humid climates, setting the UPPER TEMP too low may have the very undesirable effect of turning off condensation protection. Tempest recommends setting the UPPER TEMP about 5C above typical summer daytime temps the factory default setting is 45C for this reason, and in most cases should not be changed. Tempest further recommends setting the RH% value at 85-90%. This still gives GOS enough headroom to prevent condensation (100%RH), without excessive use of heaters. Again, it must be restated that these process only take place when the projector lamps are not running. When the projector is in show mode there is more than enough heat to go around and condensation is not an issue. 8

Sun Shades Tempest has developed a sun shade accessory for G4 enclosures, and tests are ongoing. The purpose of the sun shade is to reflect sunlight from the top of the enclosure and introduce an air gap, with convected air movement, to mitigate enclosure heating when exposed to strong sunlight. The sun shade is in three parts: 1. Reflective aluminum cover 2. 25mm (1in) thermal insulation under the cover to prevent radiated heat passing from the cover to the enclosure 3. 75mm (3in) air gap between insulation and enclosure The Sun Shade accessory can reduce daytime temperature inside the enclosure by up to 8 C. It is important to note that it has no bearing at all on the showtime operating temperature inside the enclosure. Projector Standby Mode or Off? During the day, most projectors are held in standby mode, ready to start up as soon as needed come showtime. In this situation, it will be necessary to confirm that the temperatures experienced by the projector power supplies is not exceeded. Tempest does NOT recommend running AC Assist at any time when the projector lamps are off, due to condensation risk, so this is not advised to maintain safe standby temperatures. A better strategy may be to power down the projector when not in use, if it is likely to see actual daytime temps above its standby limit. Without power connected, the projector reverts to its storage temperature limit, usually 60-70C. Powering on and off remotely may not be possible using the projector control system, but it can certainly be accomplished by controlling the enclosure s lamp relay, using either DMX or Tempest TEMPS protocol through a show control system. This may be achieved simply in most show-control environments, either using DMX (DEC4 systems require the 51.485 RS485 9

comms board), or Tempest s TEMP protocol over Ethernet (DEC4 systems require 51.EN Ethernet Comms board, DEC3.x systems require 51.ENB Ethernet Bridge see product manual for details). Conclusion In most cases, Tempest Cyclone and Blizzard enclosures will continue to work well to protect projectors in virtually all climate types. In extremes of heat and humidity, the following additional steps may be considered: 1. Add Sun Shades to mitigate high daytime temperatures under hot sun, and/or 2. Power projectors down in daylight hours, using the DEC power relay, operated by a show control system using DMX or TEMPS protocol 3. In extremely high show time temperatures, consider Tempest AC Assist. Tempest takes very seriously its claim to world leadership in enclosure technology, and is 100% committed to the following consistent actions and activities to maintain that position: 1. Continuous engineering efforts to improve our technology and therefore our products to be the best that we can possibly make them. This is a continuous endeavor, which is also endless. 2. Commitment to our customers. We will NEVER abandon a project. Tempest will do everything in its power to work with customers to assure best possible results in any situation/location. 3. Tempest will continue ever-closer relationships with projector manufacturers, sharing information and technology to assure our shared customers the best possible results in any imaginable situation. Tim Burnham President 1/18/2017 10