NUMERICAL SIMULATION OF THE NEW SOUTH WALES FIRE BRIGADE COMPARTMENT FIRE BEHAVIOUR TRAINING TEST CELL

Similar documents
CFD Model of a Specific Fire Scenario

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Shalaby Institute of Fire Protection Heyrothsberge, Germany.

Modeling a real backdraft incident fire

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

Heat Transfer in Evacuated Tubular Solar Collectors

Refining and Petrochemical Heater trouble shooting

COMPARISON OF CFD MODELLING WITH FIRE TESTS Comparison of CFD Modelling with Results of Full Scale Compartment Fire Tests in a Residential Unit

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

Water Mist-Based Fire Suppression Modelling of an Office Space Scenario

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

ASSESSMENT OF TIMBER PARTITION MATERIALS WITH FIRE RETARDANTS WITH A ROOM CALORIMETER

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

CFD Analysis of Fire Characteristics on Subway Junction Station

Figure 1. Structure Used For the Simulations.

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Using FDS Modelling to Establish Performance Criteria for Water Mist Systems on Very Large Fires in Tunnels

Recent BRANZFIRE enhancements and validation

Sprinklers Modeling for Tunnel Road Fire Fighting

Test One: The Uncontrolled Compartment Fire

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

Modeling water-mist based suppression of 34 GJ car-deck fires using FDS

Smoke Layer Height and Heat Flow through a Door

Advantages and Disadvantages of Fire Modelling

PREDICTING SMOKE DETECTOR ACTIVATION USING THE FIRE DYNAMICS SIMULATOR

Experimental Room Fire Studies with Perforated Suspended Ceiling

Travelling Fires for CFD

Tunnel Fire Dynamics and Evacuation Simulations

APPLYING LARGE EDDY SIMULATION IN THE STUDY OF FIRE AND SMOKE SPREAD AT UNDERGROUND CAR PARK

SIMULATION OF A COMPARTMENT FLASHOVER FIRE USING HAND CALCULATIONS, ZONE MODELS AND A FIELD MODEL

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

Case Study 2 (Production and Storage Buildings) - Spain

ABSTRACT. Stephen Kerber, Master of Science, Dr. James Milke, Fire Protection Engineering

An experimental study of the impact of tunnel suppression on tunnel ventilation

5B-3 6th Asia-Oceania Symposium on Fire Science and Technology 17-20, March, 2004, Daegu, Korea

THE COMBINATION OF FIRE EXTINGUISH SYSTEM AND LOCAL EXHAUST SYSTEM IN FUME HOOD

Fire Investigation in Italian Waste Treatment Plant: lessons learned and future development

FREQUENCY ENHANCEMENT OF DUAL-JUNCTION THERMOCOUPLE PROBES

Aspirating Gas Detection CFD Modelling Predicts Application Performance

VIRTUAL FIRES via COMPUTERS

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

CFD-AIDED TENABILITY ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

CFD ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

NUMERICAL STUDIES ON SMOKE SPREAD IN THE CAVITY OF A DOUBLE-SKIN FAÇADE

ctbuh.org/papers Fire Engineering the Tallest Building in the Historic City of Manchester, UK Title:

ASSESSING THE FIRE PERFORMANCE OF ELECTRIC CABLES (FIPEC)

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

Fire and Smoke Management in a Uni-Directional Road Tunnel for a Congested Traffic Condition

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Numerical study of heat pipe application in heat recovery systems

Compression of Fins pipe and simple Heat pipe Using CFD

6B-2 6th Asia-Oceania Symposium on Fire Science and Technology 17-20, March, 2004, Daegu, Korea

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Full-Scale Measurement and Numerical Analysis of Liquefied Petroleum Gas Water Heaters with Ventilation Factors in Balcony

OPTIMIZATION OF FIRE SUPPRESSION USING FIRE DYNAMICS SIMULATOR

Available online at ScienceDirect. Procedia Engineering 62 (2013 ) Charles M Fleischmann a, *, ZhiJian Chen b

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

Evolution in the knowledge about interior firefighting

ABSTRACT 1 INTRODUCTION

Investigating the Effects of Sprinkler Sprays on Fire-Induced Doorway Flows: A Two-Part Study. Jeremiah Crocker and Dr. Bin Xiao New Technology Team

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

ENSC 388: Engineering Thermodynamics and Heat Transfer

Recent Advances in Fire Suppression Modeling Issues & Perspectives of Fire Safety Engineering Applications

EXPERIMENTAL STUDIES ON THE EFFECT OF THE FIRE POSITION ON PLUME ENTRAINMENT IN A LARGE SPACE

Finned Heat Sinks for Cooling Outdoor Electronics under Natural Convection

SCALE MODEL STUDIES ON SMOKE MOVEMENT IN INCLINED TUNNEL WITH LONGITUDINAL VENTILATION AND SMOKE BARRIERS

AN ANALYSIS OF THE PERFORMANCE OF RESIDENTIAL SMOKE DETECTION TECHNOLOGIES UTILIZING THE CONCEPT OF RELATIVE TIME

Falling Film Heat Exchangers for Solar Water Heaters

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

Fire Scenario Influence of Material of Boundary Condition on Results

Sandeep V. Lutade 1, Krunal Mudafale 2, Ranjan Kishore Mallick 3 1, 2

Fire and smoke management in a uni-directional road tunnel for a congested traffic condition

Max Fire Box Users Guide

Air Flow Study inside the Supermarket Refrigeration System

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

CFD STUDY OF FIRE PROTECTION SYSTEMS IN TUNNEL FIRES

Smoke Layer Height and Heat Flow through a Door

Simulation of Engine Room Fire and Water Mist. Einar Kolstad and Bjarne P. Husted Stord/Haugesund University college

Computational simulation of road tunnel fire protection by sprinklers

The Prediction of Smoke Detector. Activation Times in a Two-Storey House. Fire through CFD Modelling

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

Simulation of Full-scale Smoke Control in Atrium

Computer Models For Fire and Smoke

2. Gas B. The column of hot gases, flames, and smoke rising above a fire; also called convection column, thermal updraft, or thermal column

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Essentials of Fire Fighting 6 th Edition Firefighter I

2. HEAT EXCHANGERS MESA

Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings

Experiments to Validate the NRCC Smoke Movement Model for Fire Risk-Cost Assessment

STUDY FOR SAFETY AT A RELATIVELY SHORT TUNNEL WHEN A TUNNEL FIRE OCCURRED

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Case Study 1 Underground Car Park

Transcription:

, Volume 9, Number 4, p.154-162, 7 NUMERICAL SIMULATION OF THE NEW SOUTH WALES FIRE BRIGADE COMPARTMENT FIRE BEHAVIOUR TRAINING TEST CELL D. Mackay and T. Barber School of Mechanical and Manufacturing Engineering University of New South Wales, New South Wales, Australia (Received 3 July 9; Accepted 18 August 9) ABSTRACT The New South Wales Fire Brigade currently gives practical flashover and backdraft training to fire fighters using a Compartment Fire Behaviour Training test cell. The test cell is a converted shipping container, where chipboard is set alight and the fire is allowed to develop into flashover. In this paper, computational models are described that are being developed with the New South Wales Fire Brigades to aid in the training procedure. CFD models of the test cell in advancing flashover scenarios, using the code FDS are compared with qualitative experimental data, with good agreement shown for the fire behaviour. Models with different configurations of the test cell are also compared, with particular consideration of the effect on time to flashover and temperature trends. The inclusion of a baffle and vent was found to have a significant effect on maximum temperatures. 1. INTRODUCTION Flashover is a transition from a slow growth period to a fully developed fire in a compartment. Fig. 1 shows the expected fire development for a compartment fire as presented by Graham et al. [1]. In the initial growth period the fire develops as the fuel burns provided enough oxygen is present, allowing hot gases with unburnt fuel to build-up on the ceiling of the compartment. Fire progression occurs as the compartment transitions into high temperatures, and there is ignition of the unburnt fuel particles and flames spread throughout the compartment with all combustible material involved. Although flashover is rapid, it cannot be easily defined as a discrete event and hence quantifying the flashover event is difficult. Waterman [2] conducted a series of experiments to determine the criteria for the onset of flashover and these experiments led to the two common definitions which are when the heat flux at the floor reaches 2 kwm -2 or when the temperature of the hot layer at the ceiling reaches 6 o C [3]. Flashover and other rapid fire phenomena have potentially disastrous consequences for the fire brigade and those they try to protect. Grimwood [4] notes that during a tragic five week period between June and July 7, twenty-two US Firefighters have been killed or badly burned through events associated with rapid fire phenomena. The NSW Fire Brigade has commenced Compartment Fire Behaviour Training (CFBT), to train fire fighters in rapid fire phenomena, the practical component of which involves using a large demonstration cell which is internally set alight and allowed under controlled conditions to reach flashover. Fig. 1: Stages in a compartment fire temperature history [1] 154

The objective of this study is to determine the ability of the Computational Fluid Dynamics (CFD) program Fire Dynamics Simulator (FDS) [5,6] to accurately simulate compartment fire behaviour by examining the flashover event in the CFBT demonstration cell. Successful validation will also allow different set-ups of the demonstration cell to be tested computationally first before live fire testing, ensuring safety concerns are met. Computational results obtained using the field model FDS are examined with qualitative thermocouple data with comparisons made for temperature and time to flashover. Variations of the CFBT demonstration cell set-up, including modifying ventilation conditions are analysed, investigating their influence on temperature and time to flashover. The visualisation program Smokeview [7] is used to view results. 2. DEMONSTRATION CELL The CFBT cell is adapted from a shipping container, with dimensions 2.4 m by 12 m by 2.6 m. A doorway exists at 2.5 m from the entry and the floor toward the back of the cell is made from brick. Backing board lines the back corner including the roof as shown in Fig. 2. A small crib made from chipboard is used as the ignition source, lit with a blowtorch at the base, for approximately one minute. The crib consists of 16 particle board sticks with dimensions 295 mm 38 mm 15 mm stacked two at a time. A.6 m baffle exists 6.5 m from the cell entry and a vent 1.76 m by.59 m exists on one wall of the cell opposite to the crib (not shown in Fig. 2). The vent is controlled by the instructor who may open it during a burn if desired. The baffle is used to contain smoke in the front portion of the room until sufficient build-up has occurred, however it is not always utilised. During CFBT training sessions, temperature data is routinely recorded. This data will be used for comparison with the CFD model, however as it is taken during real time live fire training no two data sets are identical. Four thermocouples are attached to the side and ceiling of the cell, allowing CFBT inspectors to examine the temperature profiles at these locations after a training session has been completed. Since these measurements are taken during a training session, which includes having the inspector and fire fighters in the cell (near door), fire suppression takes place as the fire develops. It includes short pulses which are used to cool the smoke on the inside of the door, however no water is applied directly to the flames. The aim of this study is to model the demonstration cell without fire suppression taking place as the main focus is flashover development. Only qualitative comparisons will therefore be made with the CFBT thermocouple data. Fig. 3 shows typical temperature plots for the CFBT cell during a training session, where thermocouple 1 () is located on the roof of the cell approximately one metre from the crib, thermocouples 2, 3 and 4 (, and respectively) are attached to a wall on the same side of the cell as the crib and mm closer to entry than the baffle, at 15 mm from ceiling, kneeling height and 15 mm from floor respectively. The different peaks and troughs are due to the spray of water into the air to cool the environment, making it safe for the fire fighters inside. Also the two data sets are taken when two different fire fighters were controlling the cell. The temperature in the back portion of the room which contains is allowed to reach much higher temperatures as fire fighters will not enter this area. As the backing boards begin to burn and flames begin to spread in this region, a rapid increase in temperature is found, limited initially to approximately o C by fire suppression. The fire is allowed to burn steadily for approximately 1 minutes while fire fighters observe the fire behaviour. Appropriate cooling techniques are used in the front portion of the room to ensure conditions at kneeling height () do not exceed 15 o C. Fig. 2: CFBT demonstration cell 155

6 1 6 8 1 1 6 1 6 8 1 1 Fig. 3: NSWFB thermocouple graphs for the demonstration cell 3. THE NUMERICAL MODEL Recently flashover has been modelled using CFD with some success [8-1]. Zou and Chow [11] successfully used FDS to model a compartment fire with gasoline pool fires as an ignition source and found good agreement between full scale experiments and FDS output. Merci and van Maele [12] also had good correlation between FDS and full scale tests in a small compartment with natural roof ventilation. They found the influence of the roof opening to only have a small influence on temperatures in the smoke layer. It is expected the current work will have a greater error than these studies because of the unpredictable nature of the crib as opposed to the pool fires. FDS is a field model which numerically solves the Navier-Stokes equations. It assumes low-speed, thermally driven flow and utilizes the Smagorinsky form of Large Eddy Simulation (LES) to solve the 156

flow. The Smagorinsky model models the turbulent viscosity µ LES as : µ ( ) S 2 LES = ρ C s 2 2Sij Sij u 3 where ( ) 2 S = And is typically given by 1 ( _ volume_ element)3 control. The default value for the Smagorinsky constant C s of.2 was used in this study. FDS includes a combustion model where gas species are described by its mixture fraction. At each point in time in each volume the mixture fraction is given for the gas species. The mixture fraction is the ratio of mass for the species compared to the total mass. Finite volume methods are applied to thermal radiation transport and Lagrangian particles are used to simulate the smoke movement. A rectilinear grid is applied which all geometry must conform to [5]. In this study, the crib was modeled as a solid block with boundary condition set as a heat release rate per unit area of 1 kwm -2, which ramps to full value in 7 s. As shown in Fig. 2, the back portion of the floor was modeled as brick which is the same as the demonstration cell. The backing board was modeled with similar material properties to the chipboard used during burns. A grid sensitivity study was undertaken on all models tested. Grid sizes of.15,.1 and.75 were compared. The effect of time step was also investigated and initial time steps were varied for the cell from.5 to.1 to determine the effect on the solution. The default time step for FDS is set by dividing the size of a grid cell by the characteristic velocity of the flow [6]. The placement of computational boundaries or domain size can have a significant effect on the result. Originally the boundaries were set to the confines of the demonstration cell and the computational domain was then extended 1 m in each direction. The model was solved both with and without the vent which can be opened and closed by an instructor during a demonstration cell burn. The baffle as shown in Fig. 2 was removed to determine the effect it had on temperature and time to flashover. 4. RESULTS AND DISCUSSION 4.1 Model Optimization A grid sensitivity study was performed with default time steps and the computational domain was bound by the shipping container. The baffle was not included in these cases. Fig. 4 shows a comparison of the temperature plots for the three grids for thermocouple 2. Significant differences can be seen in the.15 m and.1 m grids, however the.1 m and.75 grid are within 5% of each other which is considered to be in good agreement. Thermocouple 1 produced the highest difference between the.1 m and.75 m grids varying from 8 to 13%, however this is still considered to be adequate for determining fire behaviour. 8 7.75.1.15 6 1 6 8 1 1 Fig. 4: Temperature profiles at thermocouple 2 for varying grid sizes 157

The placement of the computational boundaries was examined at three locations. In Fig. 5, Domain1, Domain2 and Domain3 refer to an extension of 2.5 m,.8 m and m respectively of all domain boundaries. As can be clearly seen in Fig. 5, reducing the domain to only include the test cell itself reduced the temperature by up to 12%. In this case, vents are placed at any exit to the cell but any flow dynamics occurring at or near the boundary may not be fully captured. Minimal difference was found between Domain1 and Domain2 and hence the domain was extended to.8 m for all subsequent cases. Variation of the time steps had no measurable impact on results. The default setting was therefore used for all FDS cases. 4.2 Comparison with Expected Results It is stressed that only general comparisons with the experimental data, shown in Fig. 3, can be made as fire suppression is taking place and this will result in lower temperatures particularly close to the floor. All CFD cases were solved with a.75 m grid and extended computational domain. If we take the ceiling temperature value of 6 o C to be representative of the occurrence of flashover, then the experimental results do not reach flashover, this is due to fire suppression taking place at critical times to ensure safety for fire fighters. However the sharp temperature rise which occurs between 1 and s could be seen as a prelude to flashover which may have occurred at approximately s. Fig. 6 compares results from the computational simulation with the first of the NSWFB thermocouple readings. The FDS results shown in Fig. 6 increase steadily over the first s and flashover (as taken to be when the temperature reaches 6 o C) occurs at 21 s. Peak temperatures of close to 65 o C persist as the backing boards burn. The time to flashover as well as the general temperature profile is found to be consistent with the experimental results and expected temperature curve for compartment fires. The experimental results for and are deliberately kept low for the safety of fire fighters. Fire suppression occurs in front of the baffle which is why the temperature for is significantly different between the experimental values shown in Fig. 3 and those in Fig. 6, however the general shape of the temperature curve is consistent with expected results. Since it is shielded by the baffle, the temperature in is expected to be considerably smaller than. and do not reach temperatures greater than 1 o C, indicating that flaming combustion did not reach all the way to the floor. 8 7 Domain1 Domain2 Domain3 6 1 6 8 1 1 Fig. 5: Temperature profiles at thermocouple 2 for varying domain sizes 158

8 7 6 FDS FDS FDS FDS 1 6 8 1 1 Fig. 6: FDS temperature profiles at four thermocouple locations 4.3 Effect of Ventilation The model was solved under identical conditions as in the previous section, except a vent was added and the baffle was removed. The vent is part of the demonstration cell and gives instructors control over ventilation in the back portion of the room. The vent is 1.76 m by.59 m and is located 1.7 m above the floor. Fig. 7 shows the temperature profiles for the same thermocouple locations. Fig. 7 shows that with the vent in place, the required flashover temperature is not achieved. Maximum temperatures were maintained close to o C Similar profiles are seen for thermocouples 1, 2 and 4 compared with those in Fig. 6, however thermocouple 3 does not increase far beyond standard conditions showing that the increase in temperature did not reach to that portion of the room. This can also be seen in thermocouple 2, as since no baffle exists to shield the thermocouple, it would be expected that the temperature would increase beyond o C, however a maximum temperature of 29 o C is found after 55 s. With the open vent close to the fire source, smoke and heat are able to leave the compartment before reaching the front portion of the room where the three measurements are being taken. The heat leaving the compartment reduces the temperature around the fire source and backing boards such that flashover is no longer achieved. Due to the high aspect ratio of the compartment and the placement of the vent, a larger influence is observed by increasing ventilation than is shown in Merci and Maele [12]. 4.4 Effect of Baffle The baffle contains the smoke in the front portion of the cell until sufficient build up has occurred, and as with the vent the baffle can be removed. With the baffle removed a higher temperature were recorded by thermocouple 2 which reached 35 o C after 85 s, this is expected as it is no longer shielded. Fig. 8 shows a graphical representation of the temperature field one metre on the fire side of the baffle and one metre on the open side of the baffle. On the open side temperatures are far cooler and there is a gradual decrease in temperature until the lower cool layer is reached. However on the fire side of the baffle, the entire upper layer is close to uniform temperature with a severe drop in temperature at the bottom of the baffle. Comparison of thermocouple 2 in Figs. 7 and 9 highlight the reduction in temperature brought about by the introduction of the vent into the demonstration cell. 159

8 7 6 1 6 8 1 1 Fig. 7: FDS temperature profiles of the demonstration cell with vent open at four thermocouple locations (a) On fire side of the baffle (b) On open side of the baffle Fig. 8: Graphical representation of the temperature field 16

8 7 6 1 6 8 1 1 Fig. 9: FDS temperature profiles of the demonstration cell without the baffle at four thermocouple locations 5. CONCLUSIONS Multiple simulations of the NSWFB demonstration cell were generated in order to optimise the grid used in the final cases. Grid independence is important in gaining confidence in a numerical simulation and it was found that a grid size of.75m with domain boundaries extended beyond the sides of the cell produced acceptable results. It has been shown there was good agreement for the fire behaviour between qualitative experimental data and computational results. The FDS model produced temperatures up to 1 o C higher than the experimental data. However this was anticipated as small amounts of fire suppression were slightly cooling the upper smoke layer in the experimental results. Temperature profiles produced were in good agreement with experimental results and expected compartment fire profiles for fire development. The baffle and vent had a measurable influence on the temperatures in the hot gas layer. The introduction of a vent was found to remove a significant amount of heat from the front portion of the room as expected. Removal of the baffle showed increased temperatures in the mid region of the demonstration cell which would have been otherwise shielded by the baffle. This demonstrates the effectiveness of using these modifications to the demonstration cell as well as qualifying their use for live fire training purposes. ACKNOWLEDGMENTS The authors thank John McDonough and the NSW Fire Brigade for providing field data included in this paper. The authors acknowledge with thanks the financial support of the Australian Research Council. REFERENCES 1. T.L. Graham, G.M. Makhviladze and J.P. Roberts, On the theory of flashover development, Fire Safety Journal, Vol. 25, pp. 229-259 (1996). 2. T.E. Waterman, Room flashover criteria and synthesis, Fire Technology, Vol. 4, pp. 25-31 (1968). 3. F.M. Liang, W.K. Chow and S.D. Liu, Preliminary studies on flashover mechanism in compartment fires, Journal of Fire Sciences, Vol. 2, pp. 87-112 (2). 4. P. Grimwood, Firetactics.com. Website accessed July 7. http://www.firetactics.com/ 5. K. McGrattan, B. Klein, S. Hostikka and. J. Floyd, Fire Dynamics Simulator (version 5) user s guide, National Institute of Standards and Technology, USA (6). 6. K. McGrattan, S. Hostikka, J. Floyd, H. Baum and R. Rehm, Fire Dynamics Simulator (version 5) technical reference guide, National Institute of Standards and Technology, USA (6). 7. G.P. Forney and K. McGrattan, User s guide for Smokeview version 4 A tool for visualizing Fire 161

Dynamics Simulator Data, National Institute of Standards and Technology, USA (6). 8. M. Luo, Y. He and V. Beck, Application of field model and two-zone model to flashover fires in a full-scale multi-room single level building, Fire Safety Journal, Vol. 29, pp. 1-25 (1997). 9. A.Z. Moghaddam, K. Moinuddin, I.R. Thomas, I.D. Bennetts and M. Culton, Fire behaviour studies of combustible wall linings applying Fire Dynamics Simulator, 15 th Australasian Fluid Mechanics Conference, Sydney, Australia (4). 1. A. Hamins, E. Johnsson, M. Donnelly and A. Maranghides, Energy balance in a large compartment fire, Fire Safety Journal, Vol. 43, pp. 18-188 (8). 11. G.W. Zou and W.K. Chow, Evaluation of the field model, Fire Dynamics Simulator, for a specific experimental scenario, Journal of Fire Protection Engineering, Vol. 15, pp. 77-92 (5). 12. B. Merci and K. van Maele, Numerical simulations of full-scale enclosure fires in a small compartment with natural roof ventilation, Fire Safety Journal, Vol. 43, pp. 495-511 (8). 162