REFRIGERATION PRODUCTS

Similar documents
REFRIGERATION PRODUCTS

FALLING FILM CHILLERS

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

MACH N-407 Heat Pump Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller

Owner s Manual Therma-Stor II Heat Recovery System

SB Series Brazed Plate Heat Exchanger Installation Manual

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

MAC-120HE-03 Air-Cooled Chiller

30GT FLOTRONIC AIR-COOLED CHILLERS

30GN FLOTRONIC II AIR-COOLED CHILLERS

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

Precise Temperature Control; Compact Footprint

water to water heat pumps

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

QUAD-PLATE CHILLER MODEL QPC

OACS Outdoor Air-Cooled Central Chillers

AIR COOLED PACKAGED CHILLER

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Condensing Unit Installation and Operating Instructions

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

HEAT EXCHANGERS Maximize Thermal Efficiency with LaZerWeld Plate Heat Exchangers. For Industrial Refrigeration

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

SCHMIDT BRAZED PLATE HEAT EXCHANGERS. ...world leaders in heat transfer technology

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers

Air-Cooled Condensing Units with Compact Screw Compressors

Commercial High-Efficiency Condensing Units

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Brazed Plate Heat Exchanger Operations Manual

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

PACKAGED AIR COOLED Product Data Catalog

JCseries EVAPORATIVE CONDENSER. engineering data

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Liebert CSU3000 Chiller

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Product Chillers A P P L I C AT I O N S

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

Condensing Unit Installation and Operating Instructions

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Call us today! (800)

Call us today! (800)

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Ultimate energy saving technology

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

Commercial High-Efficiency Condensing Units

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Call us today! (800)

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

PDF Created with deskpdf PDF Writer - Trial ::

SCHMIDT- BRETTEN GASKETED PLATE HEAT EXCHANGERS

Advance Release September 2009

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

Ultimate energy saving technology

technical guide Water-Cooled Self-Contained Units

REFRIGERATED AIR DRYERS

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

SECTION WATER-SOURCE UNITARY HEAT PUMPS

BASCO TYPE ES EXTENDED SURFACE PLATE FIN HEAT EXCHANGERS. ...world leaders in heat transfer technology

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Low Profile Unit Coolers

.2 Section Waste Management and Disposal.

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

Hydronic Product & Application Catalog

High Profile Evaporator

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

NQ Series Portable Chillers

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

GP SERIES Packaged Chillers

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

PRODUCT GUIDE

ULTIMATE ENERGY SAVING TECHNOLOGY

ParaWeld Plate Heat Exchangers

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

500 EX Fusion Compressor Series

GUIDE SPECIFICATIONS AQUARIUS ii

ParaWeld Plate Heat Exchangers

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

Transcription:

REFRIGERATION PRODUCTS REFRIGERATION PRODUCTS

MUELLER REFRIGERATION PRODUCTS Falling Film Chillers Tankless Falling Film Chillers Packaged Water Chillers Quad-Plate Chillers Bakery Chillers Condensing Units Fre-Heater Brazed-Plate Heat Exchangers Accu-Therm Semi-Welded Heat Exchangers We have cool products for all your refrigeration needs!

TABLE OF CONTENTS 3 x 5 Falling Film Chiller.............................................................1 4 x 8 Falling Film Chiller.............................................................2 Tankless Falling Film Chiller..........................................................3 Packaged Chiller....................................................................4 Quad-Plate Chiller..................................................................5 Bakery Chiller......................................................................7 Air-Cooled Condensing Unit..........................................................9 Model D Fre-Heater.............................................................11 Brazed-Plate Heat Exchanger.........................................................13 Accu-Therm Semi-Welded Heat Exchanger.............................................15 1-800-MUELLER www.muel.com

MUELLER 3 X 5 FALLING FILM CHILLER Mueller s 3 x 5 falling film chiller reduces chilling time, increases production, and brings a faster return on your investment. Distribution pans are available with extra-low, low, and high flow rates, based on chilled water usage. Extra-low flow rates range from 4 to 10 gpm, low flow rates range from 8 to 15 gpm, and high flow rates range from 16 to 30 gpm (per evaporator). Benefits Easy to clean and inspect with virtually no downtime for maintenance. Mueller s patented Temp-Plate design eliminates potential chiller freeze-up. Accepts incoming fluid temperatures in excess of 80 F without the need for a secondary heat exchanger. 3 X 5 CHILLER SIZING CHART No. of Plates Dimensions Maximum Shipping Tank Capacity Distribution Pan Cabinet Size Minimum Maximum L x W x H (in) Weight (lbs) (gal) Connection Size N 2 8 68 1 /2 x 39 1 /8 x 77 3 /4 1,520 192 2" or 3" O 2 8 68 1 /2 x 39 1 /8 x 99 1 /4 1,720 400 2" or 3" Notes: Refrigerant inlet connection size per plate is 1 1 /8" tube and the outlet size is 1 1 /2" tube. Maximum weight is based on the maximum number of plates that a chiller will hold. Low flow/extra-low flow distribution pan connection is 2". High flow distribution pan connection is 3". 1

MUELLER 4 X 8 FALLING FILM CHILLER The 4 x 8 falling film chiller s fully enclosed design eliminates product contamination. The Mueller 4 x 8 enclosed-type falling film chiller is fully enclosed to ensure your product is free from airborne particles. The unit is easily accessible through gasketed doors and is specifically designed for large-capacity chilling applications. Distribution pans are available in extralow, low, and high flow rates, based on chilled water usage. Extra-low flow rates range from 6 to 16 gpm, low flow rates range from 13 to 24 gpm, and high flow rates range from 25 to 48 gpm (per evaporator). 4 X 8 CHILLER SIZING CHART No. of Plates Dimensions Maximum Shipping Tank Capacity Distribution Pan Cabinet Size Minimum Maximum L x W x H (in) Weight (lbs) (gal) Connection Size J 2 8 104 1 /2 x 39 1 /8 x 90 3 /4 2,735 361 4" or 6" K 2 16 104 1 /2 x 72 3 /8 x 90 3 /4 5,220 706 (2) 4" or 6" L 2 24 104 1 /2 x 105 7 /8 x 90 3 /4 7,705 1,052 (3) 4" or 6" M 2 32 104 1 /2 x 139 x 90 3 /4 10,190 1,397 (4) 4" or 6" Notes: Refrigerant inlet connection size per plate is 1 1 /8" tube and the outlet size is 2" pipe. Maximum weight is based on the maximum number of plates that a chiller will hold. Low flow and extra-low flow distribution pans have a 4" connection and high flow pans have a 6" connection. 1-800-MUELLER www.muel.com 2

TANKLESS FALLING FILM CHILLER Versatility to match your specific storage needs. Mueller s tankless chiller is designed for applications where it is necessary to place the chiller over the top of an existing tank. Tankless falling film chillers are available with either open- or enclosed-type cabinets. Distribution pans are available in extra-low, low, and high flow. Units are available in both 3 x 5 and 4 x 8 evaporators from 4- to 24-plate cabinets. TANKLESS CHILLER SIZING CHART Cabinet L x W x H Weight with Refrigeration Connection Size Water Pan Size (in) Plates (lbs) Inlet* Outlet* Connection Size 4-3 x 5 70 x 27 x 47 1 1 /8" Tube 1 1 /2" Tube 2" or 3" MPT 8-3 x 5 70 x 43 x 47 990 1 1 /8" Tube 1 1 /2" Tube 2" or 3" MPT 4-4 x 8 108 x 29 x 62 1 1 /8" Tube 2" Pipe 4" or 6" MPT 8-4 x 8 108 x 43 x 62 1,550 1 1 /8" Tube 2" Pipe 4" or 6" MPT 16-4 x 8 108 x 67 x 62 2,980 1 1 /8" Tube 2" Pipe (2) 4" or 6" MPT 24-4 x 8 108 x 104 x 62 4,220 1 1 /8" Tube 2" Pipe (3) 4" or 6" MPT Note: *Inlet and outlet connection sizes are per plate connection sizes. 3

PACKAGED WATER CHILLER Standard Features Stainless steel brazed-plate evaporator with 1 /2" insulation, secured in a steel bracket. Hermetic compressor with crankcase heater. Direct-drive condenser fan motor. Rust-resistant, high CFM aluminum condenser fan blade. Condenser(s): copper tube/aluminum fin. Suction accumulator. Water flow switch. Hot gas bypass capacity control. On/Off switch for control circuit operation. Manual compressor lead lag switch (dual circuit units). 24v control transformer. Return fluid sensing thermostat. High-pressure refrigerant control. Low-pressure refrigerant control with time delay. LED 24v thermometers on water inlet/outlet. Liquid line drier, sight glass, solenoid, TEV. Compressor motor contactor. Compressor and control circuit fusing. Compressor and hot gas valve time delays. Hard Start kit (single-phase units only). Painted galvanized steel sheet metal cabinet. 1 /2" insulation on all water and refrigerant lines. Full refrigerant charge from factory. Available Options Low water flow indicator with dry contacts. Refrigerant suction/discharge gauge set. Compressor run indicator. Fused stainless steel system process pump. Power on indicator. Fused stainless steel system recirculation pump. Fault indicator with dry contacts. Stainless steel storage tank with 1 /2" insulation. High temp indicator with dry contacts. Water-cooled coaxial steel/copper tube condenser. Casters (factory mounted). Water temp freeze thermostat. Fused disconnect. Fan cycle control (+40 F) for 90S, 120S, and 240D units only. Variable fan speed control (+20 F). Flooded condenser with receiver/head pressure control (-20 F). Factory-installed heat tape freeze protection, thermostatically controlled. Special piping for de-ionized and reverse osmosis. Phase monitor. Gold finned condenser coil (coastal protection). Semi-hermetic compressor. Shell-and-tube chiller barrel. Mueller packaged chillers can be utilized for commercial, industrial, Water flow meter. medical, and food process cooling. 1-800-MUELLER www.muel.com 4

QUAD-PLATE CHILLER Providing automatic water temperature control for the modern baking industry. Standard Features Outlet temperatures down to 34 F. Provides up to 288 gallons/2,400 lbs. of chilled water per hour. 120-gallon storage capacity. Batch draw-off flow rates to 20 gallons per minute. Inlet temperatures up to 80 F. Process and recirculation pump standard. 5 to 15 hp remote condensing units available. Adjustable digital temperature control with F or C display. ETL-listed. 5

QUAD PLATE CHILLER Suction Line Make-Up Water In Recirculating Flow Switch FS 2 S LS 1 Level Switch Condensing Unit Liquid Line Hot Gas Line S Quad-Plate Chiller Process Valve Chiller Pump Temp Sensor FS 1 Customer- Supplied Check Valve Process Pump TE 1 Bakery Mixer Field-Installed Process Flow Switch Field Piped Process Bypass Line PERFORMANCE SPECIFICATIONS Draw Off Refill Storage Batches Gal/lb Inlet Outlet Flow Flow Condensing Tank Per Per Temp. Temp. Rate Rate Control Unit Capacity Model No. Hour Batch ( F) ( F) (gpm) (gpm) HP Voltage Voltage (gal) QPPK-005 4 28/234 70 34 20 20 5 208-230/60/1 208-230/60/1 120 QPPK-008 4 42/350 70 34 20 20 7.5 208-230/60/1 208-230/60/3 120 QPPK-008 8 21/175 70 34 20 20 7.5 208-230/60/1 208-230/60/3 120 QPPK-010 4 48/400 70 34 20 20 10 208-230/60/1 208-230/60/3 120 QPPK-010 8 24/200 70 34 20 20 10 208-230/60/1 208-230/60/3 120 QPPK-015 4 72/600 70 34 20 20 15 208-230/60/1 208-230/60/3 120 QPPK-015 8 36/300 70 34 20 20 15 208-230/60/1 208-230/60/3 120 TECHNICAL SPECIFICATIONS - CHILLER SKID Approx. Length Width Height Shipping Wt. Model (in) (in) (in) (lb) QPPK-005 70 51 74 1,720 QPPK-008 70 51 74 1,825 QPPK-010 70 51 74 1,930 QPPK-015 70 51 74 2,035 TECHNICAL SPECIFICATIONS - CONDENSING UNIT Unit Approx. Model Length Width Height Shipping Wt. Model No. (in) (in) (in) (lb) QPPK-005 A51-OESE 40 30.5 31.5 750 QPPK-008 A753-OESE-A 121 40.25 42.5 860 QPPK-010 A103-OESE-A 121 40.25 42.5 900 QPPK-015 COL-1500H 121 40.25 40.5 1,440 Note: All of the above units consist of a quad plate heat exchanger, storage tank, on/off and temperature controls, chiller circulation pump, building supply pump, water piping, and refrigeration controls all pre-piped, wired, and mounted on a skid. The condensing units for the above chillers are all shipped loose for outdoor installation. The refrigeration piping and refrigerant charge must be supplied by others. 1-800-MUELLER www.muel.com 6

BAKERY CHILLER Providing automatic water temperature control for the modern baking industry. Standard Features Outlet temperatures down to 36 F. Provides up to 70 gallons of chilled water per hour. 50- and 120-gallon storage capacities available. Batch draw-off flow rates from 5 to 18 gallons per minute. Inlet temperatures up to 80 F. Process/recirculation pump standard. Remote condensing units. Adjustable digital temperature control with F or C display. ETL-listed. 7

BAKERY CHILLER Suction Line Liquid Line Make-Up Water In S S LS 1 Condensing Unit Field-Installed Process Flow Switch FS 1 Process Valve TE 1 Pump Bakery Mixer Bakery Chiller TECHNICAL SPECIFICATIONS Estimated Estimated Lbs. Storage Draw-Off Condensing Condensing Shipping Dimensions Per Capacity Flow Rate Unit Unit Electrical Weight L x W x H Model No. GPH* Hour (gal) (gpm) Type HP Data (lbs) (in) PMC 40/50-RC 40 334 50 14 Outdoor 2 208-230/60/1 Skid-310 32 x 24 x 72 CU-140 24 x 19 x 17 PMC 40/50-RS 40 334 50 14 None 208-230/60/1 310 32 x 24 x 72 PMC 70/120-RC 70 584 120 18 Outdoor 3.5 208-230/60/1 Skid-710 42 x 34 x 84 CU-360 40 x 31 x 32 PMC 70/120-RS 70 584 120 18 None 208-230/60/1 710 42 x 34 x 84 PERFORMANCE SPECIFICATIONS Model No. 45/50 70/120 Inlet Temp. (gph*/storage) (gph*/storage) 60 F 36 F 36 F 70 F 38 F 36 F Note: *GPH capacities are based on a minimum water refill rate of at least 8 gpm, and on drawing evenly sized and spaced batches each hour. 1-800-MUELLER www.muel.com 8

AIR-COOLED CONDENSING UNIT Mueller air-cooled condensing units can be utilized for standard refrigeration applications; or by adding the modified options, you have a condensing unit that is designed specifically to work with Mueller chillers. Units are available in sizes from 5 thru 120 horsepower. Standard Unit Features Outdoor weather hood. Weatherproof control panel. Condenser with subcooling circuit. Semi-hermetic compressor with crankcase heater. Liquid receiver. Suction/discharge vibration absorbers. Head-pressure control valve. Liquid line filter drier and sight glass. Suction filter (replaceable core filter 15 hp and larger). Suction accumulator. Liquid and suction service valves. Non-fused disconnect. Compressor and condenser fuses (as required). Oil pressure control. High/low pressure control. Manual pump-down switch. Compressor contactor. Condenser fan contactors (as required). Fan-cycling thermostat. Modified Unit Features Standard features listed above. Accumulator with heat exchanger in lieu of standard suction accumulator. Hot-gas bypass valve (piped into accumulator) with hot-gas solenoid valve. Liquid injection valve (piped into accumulator) with liquid injection solenoid valve. Separate low-pressure control to activate hot-gas bypass and liquid injection solenoid valves. W 1 1 /2" A W H Electrical Panel Disconnect Access Panel (Both Sides) D E 1 1 /2" Diameter C W 9

AIR-COOLED CONDENSING UNIT DIMENSIONAL DATA Estimated Shipping Condenser Condensing Unit Dimensions (inches) Weight Model No. No. of Fans L W H A B C D E (lbs) COL-0500H 1 81 40.25 40.5 38 43 46 18 5 750 COL-0800H 2 121 40.25 40.5 38 83 46 18 5 860 COL-0900H 2 121 40.25 40.5 38 83 46 18 5 900 COL-1000H 2 121 40.25 40.5 38 83 46 18 5 900 COL-1500H 2 121 40.25 40.5 38 83 46 18 5 1,440 COL-2000H 2 176 48.00 53.5 55 109 63 21 6 1,560 COL-2500H 2 176 48.00 53.5 55 109 63 21 6 1,780 COL-3000H 2 176 48.00 53.5 55 109 63 21 6 1,870 COL-3500H 3 229 48.00 53.5 55 162 63 21 6 1,950 COL-4000H 3 229 48.00 53.5 55 162 63 21 6 1,960 COL-5000H 4 176 96.00 53.5 55 109 63 21 6 2,400 COL-6000H 4 176 96.00 53.5 55 109 63 21 6 2,680 COL-7000H 6 229 96.00 53.5 55 162 63 21 6 3,200 COL-8000H 6 229 96.00 53.5 55 162 63 21 6 3,500 CONDENSING UNIT CAPACITIES Model No. HP 45 40 35 30 25 20 15 10 COL-0500 5 64,400 58,800 53,400 48,000 43,200 38,700 34,400 30,400 COL-0800 7.5 108,000 99,000 90,500 81,700 74,000 66,600 59,500 52,700 COL-1000 10 148,500 136,600 125,400 113,800 103,800 94,300 85,300 76,900 COL-1500 15 201,700 185,900 170,800 154,900 141,400 128,600 116,500 105,100 COL-2000 20 223,000 204,000 186,000 167,300 151,500 136,700 122,900 110,100 COL-2500 25 281,700 260,200 238,800 215,600 195,400 175,900 157,300 140,100 COL-3000 30 328,800 302,600 277,300 250,700 227,600 205,700 184,900 165,400 COL-3500 35 395,400 363,700 333,700 302,600 276,000 251,000 227,600 205,600 COL-4000 40 482,900 446,100 410,700 372,900 340,700 310,000 280,900 253,300 COL-5000 50 563,400 520,400 477,600 431,200 390,800 351,800 314,600 280,200 COL-6000 60 657,600 605,200 554,600 501,400 455,200 411,400 369,800 330,800 COL-7000 70 790,800 727,400 667,400 605,200 552,000 502,000 455,200 411,200 COL-8000 80 965,800 892,200 821,400 745,800 681,400 620,000 561,800 506,600 Note: Based on a 95 F ambient. 1-800-MUELLER www.muel.com 10

MODEL D FRE-HEATER Save Energy and Get FREE Hot Water! Up to 60 percent of the normally wasted energy discarded from refrigeration and air-conditioning systems can be recovered with the Mueller Model D Fre-Heater. By transferring the recovered heat energy to water, vast amounts of free hot water can be stored for use when and where the need arises. The bottom line is the Fre-Heater pays for itself plus reduces your energy costs proportionately to your hot-water usage. Super Hot Refrigeration In Warm Refrigerant Out Hot Water Out Walk-in coolers, freezers, commercial airconditioning systems, ice machines, and other refrigeration systems all waste enough heat energy to produce hot water on a large scale. The Model D Fre-Heater Foam Insulation enables a user to channel recovered energy from as many as six refrigeration sources into a single Fre-Heater unit, producing more than enough hot water to satisfy your needs. Mueller Temp-Plate Heat Transfer Surface Cold Water In Stainless Steel Jacket Benefits Designed for 426 psi maximum refrigerant working pressure and 150 psi maximum water working pressure. Available in 50-, 80-, and 119-gallon capacities. Heats and stores in one unit. Mueller s patented stainless steel Temp-Plate is the heart of the Fre-Heater system. This highly efficient heat transfer surface is constructed of 100% stainless steel. Thoroughly tested; CSA and ISO 9001 compliant. Fre-Heaters meet all codes required for double-wall heat exchanger construction. The industrial-grade, glass-lined water storage tank resists rust and features two replaceable magnesium anodes for extra protection against natural water corrosion, increasing the life of the tank. Model DE Fre-Heaters offer all of the features of a standard Model D Fre-Heater with the addition of a 4,500-watt, 240-volt electric element. Available in 80- and 119-gallon sizes. 11

MODEL D FRE-HEATER FRE-HEATER MODEL D TECHNICAL SPECIFICATIONS Water No. of Refrig. Per Circuit Approx. Approx. Model Mueller Connection Refrig. Connection Application Dimensions Shipping Loaded No. 1 Part No. Size Circuits Size Refrig. Capacity 2 Height Diameter Wt. (lbs) Wt. (lbs) D-50 8823750.75" MPT 1.625" ODM R-22.5 thru 4 54" 20" 220 600 D2-50 8823751.75" MPT 2.625" ODM R-22.5 thru 4 54" 20" 220 600 D-80 8823780.75" MPT 2.75" ODM R-22 1 thru 5 59" 25" 300 940 DE-80 3 8823781.75" MPT 2.75" ODM R-22 1 thru 5 59" 25" 300 940 DE-120 3 8823822 1.5" FPT 2 1.125" ODM R-22 3 thru 15 62" 29" 430 1,300 D-120 8823821 1.5" FPT 2.75" ODM R-22 1 thru 7.5 62" 29" 430 1,300 D2-120 8823820 1.5" FPT 2 1.125" ODM R-22 3 thru 15 62" 29" 430 1,300 DH-120 8823823 1.5" FPT 2 1.625" ODM R-22 7 thru 35 62" 29" 430 1,300 DA-120 8823826 1.5" FPT 2 1" MPT R-717 5 thru 25 62" 29" 430 1,300 WT-120 8823824 1.5" FPT Not applicable. See Note 4 62" 29" 375 1,200 FRE-HEATER MODEL DHS TECHNICAL SPECIFICATIONS Water Approx. Water No. of Refrig. Refrig. Dimensions Tank Shipping Model Mueller Connection Refrig. Connection Tonnage Element Element Height Diameter Capacity Weight No. Part No. Size Circuits Size Capacity* Voltage Wattage (in) (in) (gal) (lbs) DHS-120 8825141 1.25" FPT 1 1.625" ODM 14 thru 70 N/A N/A 62 29.5 119 440 DHSE-120A4 8825142 1.25" FPT 1 1.625" ODM 14 thru 70 208-230 4,500 62 29.5 119 440 DHSE-120B4 8825143 1.25" FPT 1 1.625" ODM 14 thru 70 460 4,500 62 29.5 119 440 DHSE-120A6 8825213 1.25" FPT 1 1.625" ODM 14 thru 70 208-230 6,000 62 29.5 119 440 DHSE-120B6 8825214 1.25" FPT 1 1.625" ODM 14 thru 70 460 6,000 62 29.5 119 440 Notes: 1 Nominal water tank capacity: D-50/50 U.S. gallons, D-80 and DE-80/80 U.S. gallons, and D-120/119 U.S. gallons. 2 Refrigeration tonnage capacities are evaporator load tons, not heat-of-rejection tons. Conditions for these capacities are: 30 F, 110 F condensing temperature, and 50 F discharge gas superheat. Pressure drop through the Fre-Heater refrigeration circuits at the maximum rated tonnage will be approximately 15 psi. Pressure drop at the mid-range of the tonnage ratings will be approximately 5 to 7 psi. The best overall refrigeration/heat recovery system efficiency is usually obtained at the mid-range of the tonnage capacity ratings. When selecting a Fre-Heater for commercial refrigeration applications, the compressor discharge line size as well as the tonnage rating must be considered. 3 Model DE Fre-Heaters have one 4,500-watt, 240-volt electrical element. 4 Hot water storage only. 1-800-MUELLER www.muel.com 12

BRAZED-PLATE HEAT EXCHANGER Top quality, high efficiency, and exceptional value. When you design around a Mueller brazed-plate heat exchanger, you know what to expect in your finished product. Mueller offers one of the world s largest range of brazedplate heat exchangers and the program is constantly being expanded. Many of these units are available in stock and can be shipped the next day in most cases. Many applications require small, efficient heat exchangers. The preferred choice is the brazed-plate heat exchanger (BPHE). A BPHE that is able to transfer 180,000 Btuh weighs only 44 pounds and is less than two feet high. More than 90% of its mass constitutes highly efficient heat exchange surfaces which is why it is smaller in size. Compare almost any kind of heat exchanger technology with the BPHE and you will find the BPHE s efficiency is superior and the benefits are substantial. Mueller s brazedplate heat exchanger contains up to 200 herringbonepattern-embossed plates of stainless steel construction. Every other plate is turned 180, causing the ridges of adjacent plates to intersect one another, thus forming a lattice of contact points. When these points are subsequently brazed together, the resulting unit is a compact, pressure-resistant heat exchanger in which almost all material is involved in the heat transfer process. The brazed plates form two separate channel systems. The two media assume a true counter-current flow, completely isolated from each other. This channel configuration is designed to produce high turbulence, promoting maximum heat transfer. Applications Condensers Evaporators Subcoolers Oil coolers Industrial processes Water heating Snow melting Heat pump, air conditioning, and chiller Advantages Design more compact, engineered systems. Install a more cost effective, superior solution to your heat transfer applications. Reduce cooling media volume, further reducing the cost of fluid handling systems and energy consumption. Simplify maintenance and repair. 13

BRAZED-PLATE HEAT EXCHANGER Standard Features A wide variety of solder and threaded connections are available. Plates are constructed of AISI 316 stainless steel and connections are AISI 316 stainless steel. Brazing is 99.9% copper, nickel alloy. Copper-free units are available. CE, UL, CUL, CSA. 450 psig maximum pressure. 383 F maximum temperature. 1 3 2 4 C B D A E F SPECIFICATIONS Dimensions (inches) Surface Weight Type A B C D E F Plate (ft 2 ) Empty (lbs) WP1/NP1 2.88 8.00 6.56 1.63 0.47 + (0.095 x N) 0.79 0.150 1.65 + (0.11 x N) WP2/NP2 3.50 9.06 7.19 1.69 0.47 + (0.095 x N) 0.79 0.193 2.42 + (0.13 x N) WP22/NP22 3.50 12.80 10.98 1.69 0.47 + (0.095 x N) 0.79 0.274 3.14 + (0.13 x N) WP24/NP24 3.50 18.15 16.34 1.69 0.47 + (0.095 x N) 0.79 0.366 4.20 + (0.33 x N) WG24 3.50 18.15 16.34 1.69 0.47 + (0.112 x N) 0.79 0.366 4.20 + (0.33 x N) WP3/NP3 4.88 6.73 4.72 2.88 0.47 + (0.095 x N) 0.79 0.189 2.64 + (0.13 x N) WP4/NP4 4.88 13.07 11.06 2.88 0.47 + (0.095 x N) 0.79 0.377 3.52 + (0.26 x N) WP5/AE5/NP5 4.88 20.83 18.81 2.88 0.47 + (0.095 x N) 0.79 0.634 4.40 + (0.53 x N) DW5 4.88 20.83 18.81 2.88 0.47 + (0.095 x N) 0.79 0.634 4.40 + (0.53 x N) WP7/AE7 10.59 20.83 18.11 7.88 0.47 + (0.095 x N) 3.74 1.453 12.13 + (1.32 x N) WP8 10.59 20.83 16.57 6.34 0.47 + (0.095 x N) 2.44 1.400 16.54 + (1.54 x N) WP9/AE9 10.59 31.41 27.16 6.34 0.47 + (0.095 x N) 2.44 2.150 21.15 + (1.76 x N) WP10/AE10 15.08 34.25 28.46 9.33 0.88 + (0.095 x N) NA 2.690 86.90 + (2.66 x N) Notes: WP = Copper Brazed WG = Wide Gap AE = Evaporator DW = Double Wall NP = Nickel Brazed N = Number of Plates 1-800-MUELLER www.muel.com 14

ACCU-THERM SEMI-WELDED HEAT EXCHANGER Mueller s semi-welded Accu-Therm plate heat exchanger is ideal for solution chilling and refrigerant condensing in refrigeration applications. The plate pack is built utilizing welded cassettes (two plates welded together). The refrigerant side is contained within the welded portion of the cassette to include welding of the solution port. Gaskets are used to seal the secondary side, which makes the plate pack easy to disassemble and clean. The welded cassettes are designed for optimum gasket sealing. Higher pressure improves the sealing of the gaskets. Standard Features Carbon steel, blue painted frame. (Optional stainless steel frame is available.) Plate material: 0.6 mm AISI (304 or 316) or titanium. 150 to 300 psig design pressure. ASME code standard available. Gaskets are available in Nitril, EPDM, Viton, Neoprene, or Chloroprene. Rubber lined, carbon steel, or metal lined (stainless steel or titanium) nozzles. Connections: Studded port, slip-on or weld neck flange, sanitary ferrule, or stub end. ACCU-THERM SPECIFICATIONS (IN) Port Flow Rate Model No. A B C D Size (Maximum gpm) AT-9W 34.9 13.2 22.2 4.9 1.5 120 AT-15W 45.2 13.2 32.5 4.9 1.5 120 AT-25W 49.8 21.7 30.5 10.1 4 800 AT-40W 67.4 18.7 47.5 8.3 3 450 AT-50W 68.7 21.7 49.4 10.1 4 800 AT-65W 68.9 28.7 45.4 12 8 3,200 AT-85W 90.2 28.7 66.7 12 8 3,200 A B D C 15

NOTES 1-800-MUELLER www.muel.com 16

P.O. Box 828 Springfield, Missouri 65801-0828, U.S.A. Phone: (417) 831-3000 1-800-MUELLER Fax: 1-800-436-2466 www.muel.com E-mail: refrigeration@muel.com 1993-2008 Paul Mueller Company CR-1235-6