High-efficiency Turbo Chiller (NART Series)

Similar documents
ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

Development of centrifugal chiller and heat pump using low GWP refrigerant

Development of centrifugal chiller and heat pump using low GWP refrigerant

"ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

Hitachi Centrifugal Chillers

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

Midea VFD Centrifugal Chiller Technology

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers. NEW GXG-S Series GSG-S Series Debut

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

High-Performance, High-Reliability Gas Heat Pump

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Development of Gas-Liquid Two-Phase Flow Distributor for Improving Energy Efficiency in Air-Conditioners

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A

Development of compact air heat pump inverter module chiller Air heat pump chiller DT-R(4 units)

WATE R -C OOLE D WATE R C H ILLE R S

High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A. Hitachi Appliances, Inc.

EXPERIMENTAL ACOUSTIC CHARACTERIZATION OF A WET VACUUM CLEANER

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Brazed Plate Heat Exchanger for CO Applications

Rich Knoelke. Questions or Comments: Mulcahy Shaw Water.

AIR COMPRESSORS -TURBO COMPRESSORS

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

HVAC Water chiller selection and optimisation of operation

EN aquatech.piovan.com

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

Technical Development Program

Innovation for a Better & Greener Future

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Tunnel Axial Flow Fan

Preventive Maintenance

Development of Large Size Hybrid Fan

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

ACTUAL ENERGY CONSERVATIONS BY USING NH3/CO2 REFRIGERATION SYSTEM

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

EXPERIMENTAL ANALYSIS OF TIP CLEARANCE AND CHORD LENGTH FOR OPTIMUM DESIGN OF AXIAL FLOW FAN IN AIR COOLED HEAT EXCHANGER

TEPZZ _87768A_T EP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2017/27

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by:

APS Chiller Seminar. Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017

Customers. The core of our innovation. Feeding&Conveying Drying Dosing Temperature Control Refrigeration. Granulation

High Productivity Dry Hobbing System

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings

Performance of an Improved Household Refrigerator/Freezer

Control of temperature and humidity surrounding the stone chamber of Takamatsuzuka tumulus during its dismantlement

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

MAYEKAWA MFG. CO., LTD Botan Koto-ku, Tokyo , JAPAN TEL:(81) FAX:(81)

CVGF. Water Cooled Centrifugal Chillers

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

Air flow management tutorial session. ACC Users Group 8 th Annual Conference Dallas, 4 October 2016 Sander Venema Howden Netherlands

Water-cooled Centrifugal Chiller

HFCs or the Old Refrigerants - what is the best Choice?

HVAC Clinic. Helical Rotary & Centrifugal Water Chillers

The rotary type compressor consists of an integrally formed rotor and shaft, five vanes, and a cylinder.

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Nathan Pash Subsea Technology Project Machinery Lead ExxonMobil Development Company Houston, Texas, USA

CASE STUDY AIR-CONDITIONERS

ZERO Heating Power Vending Machine Hybrid ZERO

Chapter-8 Capacity Control of Refrigeration Systems

PRODUCT CATALOG.

Study of R161 Refrigerant for Residential Airconditioning

The analysis proceeded by adopting the ASHRAE guideline for conventional HVAC chiller applications. This guideline is summarized in Table II.

PREVIEW COPY. Compressors. Table of Contents. Introduction to Compressors...3. Lesson Two Reciprocating Compressors...21

WHY SULLAIR? For more information on the IHI-Sullair joint venture, please visit 2,000th IHI-Sullair centrifugal

Theoretical and Experimental Analysis of the Superheating in Heat Pump Compressors. * Corresponding Author ABSTRACT 1.

Design And Analysis Of Centrifugal Pump

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

OIL SEPARATORS APPLICATIONS

AC Backward Curved Motorized Impellers

The Development of the Energy-Saving Technology by the Composition Control of R407C

WIDEST RANGE OF INDUSTRIAL & AIR CONDITIONER PACKAGED FAN!

Evaluation and Optimization of System Performance using HFO-mix Refrigerants for VRF and Mini-split Air-Conditioner

Compression of Fins pipe and simple Heat pipe Using CFD

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

A Novel Approach for the Thermal Management. of PC Power Supply

The Development of Heat Pump Water Heaters Using CO 2 Refrigerant

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

R134a. DCLC Series 50Hz. Water Cooled Centrifugal Chillers Cooling Capacity: 300 to 1500 TR (1055 to 5274 kw)

LTG High Pressure Humidifier and Airwasher

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

COOLING ENERGY SAVING SYSTEM USING A WATER MIST DEVICE ON WINDOWS

SOLAR PARABOLIC COLLECTOR ASSISTED EVAPORATIVE COOLING SYSTEM

Characteristics of combustion of Rich-Lean Flame Burner. under Low-Load Combustion

Transcription:

67 High-efficiency Turbo Chiller (NART Series) Wataru Seki* 1 Kenji Ueda* 1 Jyou Masutani* 2 Yoichirou Iritani* 2 Turbo chillers are widely used for district heating and cooling, heat storage (regeneration) and plant process cooling, in large-capacity air conditioning facilities. The NART series of HFC134a high efficiency turbo chiller targets the world s highest efficiency with performance 20% or more higher than that of conventional units. Development was extended to aerodynamic performance improvement of the key compressor component, heat exchanger performance, system design, and control to upgrade performance. 1. Introduction The HFC134a refrigerant used in the turbo chiller described here has been used in various chilling equipment as a substitute refrigerant for CFC12, HCFC22, and HCFC123 since about 1994. At present, HFC134a is a refrigerant that has been mostly used since it was adopted for use in car air-conditioners. In addition, because of recent concerns about global warming, improving the efficiency of thermal equipment that consumes large amounts of electric energy is conred as the most important and first priority subject. This is especially the case in the application of such refrigerant to plant process-cooling equipment with a product life cycle of 20 years or longer. In addition, 2001 has seen the introduction of strict statutory requirements for the recovery and destruction of refrigerants in order to control the emission of chlorofluorocarbons. As a result, chillers are now required to use refrigerants that have a guaranteed stable supply and further, are required to be highly reliable and have noticeable energy-saving performance. Hence, newly developed chillers are designed to attain the world s highest efficiency level of COP 6.1. 2. Optimized refrigerant cycle The more compression and expansion stages there are, the closer one can come to achieving to the ideal refrigerant cycle. In the chiller developed at this time, however, a two-stage compression cycle was adopted taking into conration the characteristics of the HFC134a refrigerant, optimum impeller design, compact equipment design, and cost-savings. For four typical refrigerant cycle systems shown in Fig. 1, the coefficients of performance (COPs) were compared. As a result, it was known that, in a two-stage compression cycle, a two-stage expansion could deminish the first stage recirculating flow rate and a subcooling could minimize the second stage recirculating flow Single stage compressor Single stage compressor Two-stage compressor Two-stage compressor Subcooler Subcooler Sub-cooling Sub-cooling (4) (2) (4) (2) (2) (2) (4) (4) Compression (2) Condensation Expansion (4) Evaporation *1 Air-Conditioning & Refrigeration Systems Headquarters *2 Takasago Research & Development Center, Technical Headquarters

68 Speed-increasing gear unit Closed electric Compressor Second stage impeller First stage impeller Suction vane Refrigerant gas inlet Ball bearings Diffuser width controller Refrigerant gas outlet Flow improvement on negative of the blade Fig. 4 Integrated flow analysis of impeller and diffuser The flow contours cre-ated by CFD analysis are shown. Flow improvement between blades Example of improved impeller in flow rate. Accordingly, both two-stage expansion and subcooling were added. A two-stage compression, twostage expansion sub-cooling cycle is theoretically about 10% superior to a single stage cycle. 3. Improvement of compressor aerodynamic perfor- mance When a two-stage compression design is adopted, the impeller inlet Mach number becomes subsonic. Therefore, the following aerodynamic designs were taken in order to raise efficiency by improving the flows in the impeller in and the outlet downstream. Fig. 2 shows a cross section of the compressor for the chiller developed this time. Design of high efficiency subsonic impeller. Both the first and second stages of the system were designed to have large specific speeds, respectively, taking a discharge coefficient that is larger than that commonly used for conventional two-stage type impellers.. In order to minimize secondary flows in the impeller, the distribution of the blade angle and blade inclination angles were determined by using the newest CFD (Computational Fluid Dynamics). Fig. 3 shows an example taken during this study. It shows the state in which the secondary flows and

69 Pressure Tip Hub (a) Open impeller Negative Second stage impeller First stage impeller Pressure Shroud Hub (b) Closed impeller Negative boundary layer thickness on the negative-pressure blade are declining.. Flow distortion in the impeller outlet downstream diffuser could be improved by improving the flows in the impeller. Fig. 4 shows an example of the computed fluid distortion analysis based on an integrated analysis of the impeller and diffuser.. Since the secondary flows in the impeller could be reduced, the number of blades was optimized, in order to reduce the wetted area, increase the inlet throat area, and reduce the tailing vortex due to the rear edge thickness of the blades. The optimized number of blades was also determined using the results of CFD. (2) Adoption of open impeller A comparison was made between both open and closed impellers during development of the chiller system. Flow analysis and practical unit performance tests showed that they have about the same level of performance. The open impeller was adopted for the practical units in order to permit:. precise machining using a five-axis NC machine;. excellent -finishing at a several micron level;. reduction on weight, so that the weight of the compressor shaft and the size of the impeller can be reduced to a compact size in a rotor dynamics design; as well as. cost reductions owing to advances in machining technology. Fig. 5 shows a comparison in the flow analysis results of both open and closed impellers. In the open impeller, both the boundary layer and flow deviation increase due to the influence of the clearance between the blade tip and the shroud. Thus, the shroud form was determined in the practical unit according to the tip shape deformed in the operating state in order to minimize the clearance so as to reduce gas leakage. As mentioned above, very careful attention was paid to this point, so that differences in performance between the open and closed impellers could be successfully eliminated. Shaft system evaluation The impeller shaft is longer than conventional twostage shafts because of designing larger specific speed impellers. As a result, the shaft length extruded from the bearing position also becomes longer. Accordingly, the soundness of the shaft strength was verified by rotor dynamics analysis. Furthermore, the natural frequencies of the rotor blades installed on the shaft were measured to confirm the avoidance of coupled vibration of the rotor blades with the shaft and resonance of the rotor blades with the upstream stator blades. In addition, it was also confirmed in practical unit verification tests that no irregular vibration was generated under various operational states, including surging, with the shaft and casing vibrations monitored. Fig. 6 shows the two-stage open impeller assembled with the shaft. 4. Design for reducing mechanical loss The mechanical loss could be reduced to 50% or less of that of conventional units through the use of rolling bearings in place of plane bearings. A bearing life of 50 000 hours or more was ensured (2). A gear power-transferring efficiency of 99% or higher could be achieved by optimizing the pressure angle (2). 5. Improvement of heat exchanger performance In order to improve the heat transfer performance

70 Refrigerant to compressor Demister Refrigerant liquid Larger heat transfer Until now, multi-function color liquid crystal mi- Tuberemoved zones Refrigerant from economizer Heat transfer tube bundles Liquid-distributing plate Smaller heat transfer Fig. 8 Example of evaporator fluid analysis An example analyzing the distribution of shell boiling heat transfer coefficient in the cross section of an evaporator is shown. Result of CFD analysis Baffle plate Refrigerant gas inlet Refrigerant liquid outlet Vcct or 0.0 2.0 4.1 6.1 8.1 10.2 12.2 14.2 m/s of the evaporator, it is essential the overall heat transfer performance be improved by optimizing the tube arrangement, since there is a limit to how much the performance of the heat transfer tubes only can be enhanced. In particular, a zone with a high void ratio is produced in the upper part of the tube bundle due to the accumulation of bubbles generated in the lower heat transfer tubes. This results in nucleate boiling being restrained and a deterioration in heat transfer performance. In order to resolve this problem, tube-removed zones are provided in the tube bundle so as to collect generated bubbles into the zones in order to eliminate them, as shown in Fig. 7. Furthermore, when many tube bundles are piled up, it is predicted that dry out will occur and the boiling heat transfer coefficient will be reduced since the refrigerant around the upper heat transfer tubes is blown off by bubbles with increased ascending velocities. The horizontal pitch of the heat transfer tubes was increased in order to address this problem. On the basis of such basic data as the correlation between heat transfer coefficients and void ratios, obtained by factor tests, the heat flow-analyzing general code was improved. This improvement made it possible to predict the distribution of heat transfer coefficients of an evaporator using HFC134a, and it was applied to a practical design. An example of the results of evaporator heat transfer analysis is shown in Fig. 8 (4). (2) In order to improve condenser heat transfer performance, it is necessary to reduce the thickness of the condensate film on the heat transfer tubes and prevent deterioration of condensing performance in the lower tube bundles due to the accumulation of descending condensate. Just as with an evaporator, in order to improve the condensing heat transfer, there is a limit to how much only heat transfer tube performance can be improved. Thus, it was intended to make the liquid film uniform, with the condenser in flow homogenized according to the results of a single phase gas fluid analysis. Fig. 9 shows an example of the results of analysis for a condenser (4). 6. Control system

71 Compressor Running Compressor Running Basic display Display showing a real time Required power (kw) 400 350 300 250 200 50 Power for cooling refrigerant (2) Windage loss Bearing loss (4) Gear loss (5) loss (6) Piping loss (7) Heat exchanger SD (5) (7) Theoretical gas horsepower (2) (4) (6) Conventional machine Loss due to compressor efficiency crocomputer panels have been used in the control of chillers. However, an assessment of the conventional control functions was carried out with the development of the NART series, and many new functions were added. For the load control, both precise load and cooling water traceabilities were achieved by individual control of the inlet vane, diffuser width, and hot gas bypath valve. Also, control of the expansion mechanism was optimized by internal computation of the recirculating amount of refrigerant. Other additional functions were newly provided as well including scheduled operations, a function to prevent irregular or incorrect operation, BAS communication monitoring function, and operating machine number controlling function so that the equipment control system would be able to meet a wide range of needs. Fig. 10 shows the liquid crystal display (LCD) of a control panel (5). 7. Performance of practical unit Energy savings of about 20% Developed machine Loss due to compressor efficiency Because every individually developed element COP Coefficient of performance (COP) 7 Newly developed unit 6 5 Conventional unit 4 3 Partial load performance At a chilled water temperature of 7 o C 2. Cooling water is based on JIS 1 0 20 30 40 50 60 70 80 90 100 Refrigerant capacity (%) 6.5 6.0 5.5 5.0 4.5 4.0 0 200 400 600 800 [Condition] Chilled water temperature: 12/7 o C Cooling water temperature: 32/37 o C 1000 1 200 1400 16001800 Refrigerant capacity (Rt) 2000 achieved its target, overall performance was improved 20% or more compared with conventional chillers. Fig. 11 shows a breakdown of the areas in which improvements were realized. In addition, excellent partial load performance was obtained by optimizing both the inlet vane and diffuser width controls. A graph of the partial load performance of the system is shown in Fig. 12 (5). In order to evaluate the durability of the equipment, disassembled inspections were carried out after the following continuous operations and testing to verify the soundness of the equipment. Other tests included the following: operation at a rotating stall point,. operation under a surging state, and power failure tests. Verification tests of all the types in the series have

72 already been carried out over a range of 350 through 1 660 USRt as an overall test of the entire NART series. As a result, it was confirmed that all the types could achieve their design performance levels. Fig. 13 shows the COP for each capacity type. 8. Conclusion The commercialization of the turbo chiller NART series with the world s highest efficiency of COP 6.1 (at a chilled water base of 12 o C/7 o C) was realized using the HFC134a refrigerant (Fig Fig. 14). (2) High efficiency operation could be achieved throughout year because of the excellent load traceability and cooling water traceability. The system was shown to have sufficient durability under practical operation states, such that the compressor did not need to be overhauled for 50 000 hours or longer (4) Significant expansion and improvement in control functions offer excellent operability and communication ability to the control panel (5) Ninety chillers have already been delivered so far, and their high performance and reliability achieved their designed goals as highly evaluated systems by their customers. References Kawakami, T. et al., Development of Centrifugal Compressor for HFC134a Turbo Chiller, Proceedings of 2000 JSRAE Annual Conference, p.202 (2) Yoshida, Z. et al., Tribological Technology for High Efficient Centrifugal Chiller, Mitsubishi Heavy Industries Technical Review Vol.39 No.1 (2002) p.26 Kawada, A. et al., Development of HFC134a Turbo Chiller, Proceeding of 2000 JSRAE Annual Conference, p.205 (4) Ueda, K. et al., Development of High-Efficiency HFC134a Turbo Chiller, Proceedings of 2001 JSRAE Annual Conference, p.205 (5) Seki, W. et al., World s Highest Efficient HFC134a Turbo Chiller (NART Series), Heating Piping & Air Conditioning Vol. 39 No.2 (Feb. 2001)