The New Life Safety Code & Texas Responds with New Small House Nursing Design Standards

Similar documents
NFPA 101 Life Safety Code Culture change 2012

Chapter 43, Building Rehabilitation allows for degrees of compliance based on the work category such as the extent of work.

Agency for Health Care Administration. Eddie Alday Life Safety Code Lead 30 th AHCA Seminar 23 September 2014

Agency for Health Care Administration

FHCA 2014 Annual Conference & Trade Show

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4

CMS Announcement 3/27/2017. Adoption of 2012 Life Safety Code Health Care Facilities Code. Kenneth Daily, LNHA

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5

DEALING WITH FIRE SAFETY

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

Department of Health Life Safety Code Update

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

Iowa State Fire Marshal

Report on First Revisions with Statement June 2014 NFPA 101

New DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE

School Fire Safety Checklist

NFPA 101 and NFPA 99, 2012 Editions Code Update. where art meets engineering

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

Agency for Health Care Administration

Agency for Health Care Administration

Schools and the Fire Code A Partnership for Safety

SAF-BCF SECOND REVISIONS WITH STATEMENTS

Are there any policies regarding outlets that contain USB ports?

Agency for Health Care Administration

Family Foster Home Fire Safety Evaluation Checklist Instructions

CMS CATEGORICAL WAIVER CHECKLIST Page 1 of 7 Waiver Topic, description & location:

Building Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1

Agency for Health Care Administration

Washoe County Department of Social Services

ASCs & LSC. Alice Epstein, DFASHRM, FNAHQ

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

Presented by: Brad Keyes, CHSP Senior Consultant Keyes Life Safety Compliance, LLC

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

CHAPTER 7 ALTERATIONS LEVEL

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes

Denver Fire Department Fire Prevention Division

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

Prepublication New Text Jan 2018 Changes to Environment of Care and Life Safety Chapters

Ch. 569 FIRE AND SAFETY SERVICES 28 CHAPTER 569. FIRE AND SAFETY SERVICES GENERAL PROVISIONS INTERNAL DISASTER PLAN EVACUATION DRILLS

Emergency Planning for Institutional Facilities

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #2

Residential-based Care Facility R-4 Guideline

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

Life Safety Code and Informal Review Process Updates

Wausau Fire Department Inspection Violation Code Listing (Modified) All Applicable Records

LIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE

Report on First Revisions with Statement June 2014 NFPA 101

2012 International Fire Code Errata (Portions of text and tables not shown are unaffected by the errata)

From Your Building Inspector

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

H BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION

Agency for Health Care Administration

Agency for Health Care Administration

Fraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.

First Revision No NFPA [ Section No ]

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

Apartment Fire & Safety Inspection. City of Guadalupe

EC EP 14 All other electrical K-920 equipment in patient care vicinity NFPA , Chapter 10

Level I Chapter 1 Worksheet

Danilo B. Concepcion, CBNT, CCHT-A Operations Manager St. Joseph Hospital Renal Services

Compliance w/ the 2012 Life Safety Code

Agency for Health Care Administration

EC 5.10 FIRE PREVENTION MANAGEMENT

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

Agency for Health Care Administration

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Defend In Place 2012 IFC Overview of Institutional Occupancies

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Agency for Health Care Administration


AD HOC HEALTHCARE COMMITTEE MEANS OF EGRESS WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B MOE COMMITTEE

IFC Significant Changes from the 2009 to the 2015 Edition Tier 1

Agency for Health Care Administration

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101):

FIRE PROTECTION INTRODUCTION

CODE TECHNOLOGIES COMMITTEE NURSING CARE FACILITIES WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B

RULES OF THE TENNESSEE DEPARTMENT OF INTELLECTUAL AND DEVELOPMENTAL DISABILITIES OFFICE OF LICENSURE CHAPTER LIFE SAFETY LICENSURE RULES

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

Agency for Health Care Administration

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Residential Care Facilities Requirements

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

Fire/Life Safety Policy

Rental Housing Inspection Guide

FIRE SAFETY SURVEY REPORT 2000 CODE - HEALTH CARE Medicare Medicaid

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

40 TAC Tex. Admin. Code tit. 40, What safety precautions must I follow when children in my care use a swimming pool?

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

REGULATIONS FOR OUTDOOR GATHERINGS AND EVENTS TENTS & MEMBRANE STRUCTURES

K SURVEY FOR DATE OF PLAN APPROVAL SURVEY UNDER

SAFETY TIPS. From Your Building Inspector. The Sound of Safety.

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

FIRE SAFETY SURVEY REPORT AMBULATORY SURGICAL CENTERS (ASC) & END STAGE RENAL DISEASE (ESRD) MEDICARE

Texas Administrative Code

DEPARTMENT OF CONSUMER AND INDUSTRY SERVICES DIVISION OF ADULT FOSTER CARE LICENSING ADULT FOSTER CARE FACILITIES

Transcription:

The New Life Safety Code & Texas Responds with New Small House Nursing Design Standards Fred Worley, Architect Architectural Unit Manager, TDADS Wes Wells, Administrator Buckner Westminster Place

DADS REGIONAL MAP

DADS LSC STAFF - 2015

Statewide Totals March 10, 2017 Adult Day Care 467 Assisted Living 1,880 ICF-IID/RC 813 Nursing 1,239 Total Facilities 4,399 HCSSA agencies 6,332

Codes for Everyone and Everything Municipal Codes: Zoning, Drainage, Water, Sewage Local Codes: Building and Fire Regulations State Codes: Building, Fire and Design Codes for Licensure Federal Codes: Fire Codes for Certification

Some Major Codes that Influence Construction State/City Building Codes International Code Council ADAAG - ADA Accessibility Guidelines ADA - Americans with Disabilities Act Texas Standards for Accessibility

Some Major Codes that Influence Construction Nursing Facility Requirements for Licensure and Medicaid Certification State Licensing Standards CMS - Center for Medicare and Medicaid Services State Operations Manual

Some Major Codes that Influence Construction NFPA - National Fire Protection Association Life Safety Code (LSC) State & Local Health Department Regulations Texas Food Establishment Rules

Codes Enforced by Many Authorities Having Jurisdiction (AHJ) Local Building Official Local Fire Inspector State Licensing Surveyor Federal Certification Surveyor Design and Building Professionals Insurance Carrier Certifying Agencies Manufacturers and Suppliers

LIFE SAFETY CODE (LSC) The LSC s purpose is to provide minimum requirements for the design, operation, and maintenance of buildings and structures for safety to life from fire.

LIFE SAFETY CODE (LSC) Protection of occupants is achieved by a combination of: Prevention of ignition Detection of fire Control of fire development

LIFE SAFETY CODE (LSC) Protection of occupants is achieved by a combination of: Extinguishment of fire Provision of refuge or evacuation Staff reaction Provision of fire safety information

LIFE SAFETY CODE (LSC) Key Features Related to Health Care Facilities Protection Against Fire Passive Protection (Building Construction) Active Protection (Sprinklers, Fire Alarm) Evacuation Staged Evacuation Defend-in-Place

Fire Safety Codes Often Lead Designers to Predictable Designs Requirement: Bedrooms must exit through a corridor Minimum 8 feet clear corridor width Cooking facilities considered as hazardous Eliminate combustible materials Result: Double-loaded corridors lined by bedrooms Straight undifferentiated 8-0 wide corridors Hide the residential center of home from daily experience Limits decoration and individual character

History of Health Care Design

History of Health Care Design

History of Health Care Design

How/why are Codes Changed? Bad things happen (people die in a fire) or improvements in technology Culture Change (less institutional design) Educate the enforcers in charge Learn the code revision cycles Work with state officials to change standards Work with state provider associations Develop talking points Make the economic case

How/why are Codes Changed? 1987 Nursing Home Reform Act (OBRA) 2009 Pioneer Network with Coalition of Associations supported by the Rothschild Foundation created a National Life Safety Task Force to Change the Code Task Force met and identified 4 major revisions to the 2012 Edition of the LSC

How/why are Codes Changed? 2011 2012 NFPA Life Safety Code Revised with all Revisions Accepted 2012 CMS Published Culture Change S&C Letter 2013 Task Force Working With All States to Adopt the 2012 Edition or to Accept Equivalencies

How/why are Codes Changed? 2013 Task Force working on 2015 Edition of LSC and on IBC and IFC to accept same revisions 2014 2015 NFPA Life Safety Code Revised with disguising lockable doors accepted

2015 NFPA Life Safety Code Revised with disguising lockable doors acceptable

Code Effective Dates For Certification by CMS: 2012 ed. of NFPA 101 Life Safety Code Effective Date: July 5, 2016 Compliance Date: November 1, 2016 For Licensure: State NFR/LMC revisions in process

Some Hints on How to Use the NFPA Codes and Standards National Fire Codes (NFC): A softbound, multi-volume annual compilation of all NFPA Technical Committee documents (300+) with the 17 volumes consisting of codes and standards and a supplemental volume with revisions, as well as an additional volume containing a Master Index of the code set.

Some Hints on How to Use the NFPA Codes and Standards

Some Hints on How to Use the NFPA Codes and Standards Start with the Correct Occupancy Chapter Connect the dots to the Referenced Code or Standard Difference between New and Existing Occupancy

Some Hints on How to Use the NFPA Codes and Standards Existing: A building erected or officially authorized prior to the effective date of the adoption of this (current) edition of the Code by the agency or jurisdiction. (From NFPA Glossary of Terms)

Some Hints on How to Use the NFPA Codes and Standards CMS S & C : 16-29-LSC Buildings constructed before July 5, 2016 can meet Existing Occupancy requirements Buildings that receive design approval or building permits before July 5, 2016 can meet Existing Occupancy requirements

Some Hints on How to Use the NFPA Codes and Standards NFR/LMC 19.301(a) The New Health Care Occupancies chapter of the Life Safety Code is applicable to new construction, conversions of existing unlicensed buildings, remodeling, and additions. NFPA 101 Chapter 18 New Health Care

Some Hints on How to Use the NFPA Codes and Standards NFR/LMC 19.301(a) The Existing Health Care Occupancies chapter of the Life Safety Code is applicable to existing nursing homes. NFPA 101 Chap. 19 Existing Health Care

Subchapter D 19.300 General Requirements NFR/LMC 19.301(b) The requirements of this subchapter are applicable to existing nursing facilities unless otherwise stated.

Subchapter D 19.300 General Requirements Refer to 19.330-19.343 of this title (relating to Facility Construction) for additional requirements for new construction, conversions of existing unlicensed buildings, remodeling, and additions.

Subchapter D 19.300 General Requirements An existing unlicensed building is defined as any building (or portion thereof) which is not presently licensed as a nursing home.

NFR/LMC Nursing Facility Requirements for Licensure and Medicaid Certification Chapter 19 Subchapter D Construction Division 1. General Provisions Division 2. Licensed before September 11, 2003 Division 3. Provisions Applicable to All NFs Division 4. Construction and Initial Survey

NFR/LMC Nursing Facility Requirements for Licensure and Medicaid Certification Division 5. Licensed after 9/11/03 and before January 18, 2018 Division 6. Plan Review Division 7. Small House and Household NFs Division 8. Building Rehabilitation Division 9. Licensed on or after January 18, 2018

2012 NFPA Life Safety Code & CMS Cultural Changes (formerly Categorical Waivers)

Changes to 2012 Life Safety Code Kitchens serving 30 or less residents can be open to the corridor. Fixed seating allowed in corridors 8 feet or greater in clear width. Wheeled equipment in corridors permitted.

Changes to 2012 Life Safety Code Projections up to 6 inches permitted in corridors. Gas fireplaces allowed except in resident sleeping areas. More combustible decorations permitted on walls, ceilings and doors

Changes to 2012 Life Safety Code Kitchens serving 30 or less residents can be open to the corridor.

NFPA 101, LSC 2012 Edition 18.3.2.5.3 Kitchens can be open to the corridor Limited to 30 persons/meals in that smoke compartment Range hood 500 cfm and UL 300 or 300A with manual release and interlock fuel control Deep-fat frying prohibited Portable fire extinguisher in area

NFPA 101, LSC 2012 Edition 18.3.2.5.3 Kitchens can be open to the corridor Switch in restricted location to deactivate range, and on a timer ITM in accordance with NFPA 96 Minimum two AC powered smoke alarms 20-25 feet away or system smoke detector that does not initiate general alarm or notify central station

NFPA 101, LSC 2012 Edition 18.3.2.5.5 Cooking equipment protected by a NFPA 96 may be open to other spaces, like dining rooms, but must be separated from the corridor

Changes to 2012 Life Safety Code Fixed seating allowed in corridors 8 feet or greater in clear width.

NFPA 101, LSC 2012 Edition 18.2.3.4 (5) Aisles and corridors not less than 8 feet Fixed furniture permitted Attached to floor or wall Leaves 6 feet clear Located on one side of corridor Less than 50 sf and 10 feet apart Doesn t obstruct access to building service or fire protection equipment

Changes to 2012 Life Safety Code Wheeled equipment in corridors permitted.

NFPA 101, LSC 2012 Edition Edition 18.2.3.4 (1-4) Aisles and corridors not less than 8 feet 44 for non-patient use Wheeled equipment leaving 5 feet clear Removal in fire-safety plan Limited to equipment in use and carts in use Medical emergency equipment not in use Patients lifts and transportation equipment

Changes to 2012 Life Safety Code Gas fireplaces allowed except in resident sleeping areas.

NFPA 101, LSC 2012 Edition 18.5.2.3(2) Direct-vent gas fireplaces, as defined in NFPA 54, National Fuel Gas Code, shall be permitted inside of smoke compartments containing patient sleeping areas, provided that all of the following criteria are met:

NFPA 101, LSC 2012 Edition Comply with NFPA standards for chimneys, fireplaces, fuel gas, and electrical code Not in patient sleeping room QR sprinklers throughout smoke compartment Sealed glass front with wire mesh panel or screen Locked or restricted location for controls Carbon monoxide detector in room with fireplace

NFPA 101, LSC 2012 Edition 18.5.2.3(3) Solid fuel fireplaces, as defined in NFPA 54, National Fuel Gas Code, shall be permitted only in areas other than patient sleeping areas, provided that all of the following criteria are met:

NFPA 101, LSC 2012 Edition Separated from patient sleeping space with one-hour fire-rated construction Comply with NFPA standards for chimneys, fireplaces, fuel gas, and electrical code Hearth raised not less than 4 inches 650 degree heat tempered glass Carbon monoxide detector in room with fireplace

Changes to 2012 Life Safety Code More combustible decorations permitted on walls, ceilings and doors

NFPA 101, LSC 2012 Edition 2000 Edition 18.7.5 Furnishings, Bedding, and Decorations. 18.7.5.1* Draperies, curtains, etc. per 10.3.1 2012 Edition (3) Such draperies and curtains shall not include draperies and curtains at windows in patient sleeping rooms.

NFPA 101, LSC 2012 Edition (4) Such draperies and curtains shall not include draperies and curtains in other rooms or areas where the draperies and curtains comply with both of the following: (a) Individual drapery or curtain panel area does not exceed 48 sf (4.5 m2) (b) Total area of drapery and curtain panels per room or area does not exceed 20 percent of the aggregate area of the wall on which they are located

NFPA 101, LSC 2012 Edition 2000 Edition 18.7.5.4 Combustible decorations shall be prohibited in any health care occupancy unless they are flameretardant. Exception: Combustible decorations, such as photographs and paintings, in such limited quantities that a hazard of fire development or spread is not present.

NFPA 101, LSC 2012 Edition 2012 Edition 18.7.5.6 Combustible decorations shall be prohibited in any health care occupancy, unless one of the following criteria is met:

NFPA 101, LSC 2012 Edition 2012 Edition 18.7.5.6(1) They are flame-retardant or are treated with approved fire-retardant coating that is listed and labeled for application to the material to which it is applied.

NFPA 101, LSC 2012 Edition 2012 Edition 18.7.5.6(2) The decorations meet the requirements of NFPA 701, Standard Methods of Fire Tests for Flame Propagation of Textiles and Films.

NFPA 101, LSC 2012 Edition 2012 Edition 18.7.5.6(3) The decorations exhibit a heat release rate not exceeding 100 kw when tested in accordance with NFPA 289, Standard Method of Fire Test for Individual Fuel Packages, using the 20 kw ignition source.

NFPA 101, LSC 2012 Edition 2012 Edition 18.7.5.6(4) The decorations, such as photographs, paintings, and other art, are attached directly to the walls, ceiling, and nonfire-rated doors in accordance with the following:

NFPA 101, LSC 2012 Edition 2012 Edition 18.7.5.6(4)(a) Decorations on non-fire-rated doors do not interfere with the operation or any required latching of the door and do not exceed the area limitations of 18.7.5.6(b), (c), or (d).

NFPA 101, LSC 2012 Edition 2012 Edition 18.7.5.6(4)(b) Decorations do not exceed 20 percent of the wall, ceiling, and door areas inside any room or space of a smoke compartment that is not protected throughout by an approved automatic sprinkler system in accordance with Section 9.7.

NFPA 101, LSC 2012 Edition 2012 Edition 18.7.5.6(4)(c) Decorations do not exceed 30 percent of the wall, ceiling, and door areas inside any room or space of a smoke compartment that is protected throughout by an approved supervised automatic sprinkler system in accordance with Section 9.7.

NFPA 101, LSC 2012 Edition 2012 Edition 18.7.5.6(4)(d) Decorations do not exceed 50 percent of the wall, ceiling, and door areas inside patient sleeping rooms having a capacity not exceeding four persons, in a smoke compartment that is protected throughout by an approved, supervised automatic sprinkler system in accordance with Section 9.7.

Texas Small House or Household Licensing Standards

Texas Small House or Household Licensing Standards Maximum 16 persons per Household or SH All rooms are private with full bath Small kitchen (staff station) Living/dining within household or SH Public, kitchen, and staff bathrooms can be combined with toilet adjoining spa

Small House or Household Licensing Standards Porch with suitable furniture required Barn doors, or sliding doors, permitted at bathrooms Sill heights of windows in Living and Dining Room maximum sill height 36 AFF

Small House Nursing Homes 19.345 Small House and Household Facilities (d) A small house or household facility must be designed and equipped to provide a homelike environment that promotes resident-centered care.

Small House Nursing Homes a bedroom must be occupied: by only one resident; or (ii) by two residents, if they are members of the same family and the bedroom size, furniture, and headboard wall requirements for double occupancy are met;

Small House Nursing Homes the toilet requirements in 19.334(a)(8) of this subchapter must be met, except a bathroom must serve no more than one resident room and must include a lavatory, toilet, and a shower or bathing unit;

Small House or Household examples

Small House or Household examples

Small House or Household examples

Small House or Household examples

Small House or Household examples

Small House or Household examples

Small House or Household examples

Small House or Household examples

Small House or Household examples

Small House or Household examples

Small House or Household examples

NFPA 101, LSC 2012 Edition 18.2.2.2.10.2 Horizontal-sliding doors serving an occupant load of fewer than 10 shall be permitted, provided:

NFPA 101, LSC 2012 Edition 2012 Edition 18.7.5.7.2* 96 gallon recycling containers excluded from the requirements of 18.7.5.7.1 when the following conditions are met:

NFPA 101, LSC 2012 Edition 2012 Edition 18.7.5.7.2* (1) Limited to 96 gallons (2) Larger containers must be stored in hazardous areas (3) Container size limited in hazardous areas. (4) Labeled and listed w/ FM Approval Standard 6921

NFPA 99 National Health Care Facilities Code 2012 Edition Does not have occupancy chapters CMS is not adopting certain chapters of NFPA 99, including Information Technology and Communications Systems for Health Care Facilities, Plumbing, Emergency Management and Security Management

NFPA 99 National Health Care Facilities Code 2012 Edition CMS S & C : 17-05-ALL 10/28/2016 Emergency Preparedness Requirements for Medicare and Medicaid Participating Providers and Suppliers final rule effective November 15, 2016 and compliance by November 15, 2017.

NFPA 99 National Health Care Facilities Code 4.1* Building System Categories. Building systems in health care facilities shall be designed to meet system Category 1 through Category 4 requirements as detailed in this code.

NFPA 99 National Health Care Facilities Code 4.1.1* Category 1. Facility systems in which failure of such equipment or system is likely to cause major injury or death of patients or caregivers shall be designed to meet system Category 1 requirements as defined in this code.

NFPA 99 National Health Care Facilities Code 4.1.2* Category 2. Facility systems in which failure of such equipment is likely to cause minor injury to patients or caregivers shall be designed to meet system Category 2 requirements as defined in this code.

NFPA 99 National Health Care Facilities Code 4.1.3 Category 3. Facility systems in which failure of such equipment is not likely to cause injury to patients or caregivers, but can cause patient discomfort, shall be designed to meet system Category 3 requirements as defined in this code.

NFPA 99 National Health Care Facilities Code 4.1.4 Category 4. Facility systems in which failure of such equipment would have no impact on patient care shall be designed to meet system Category 4 requirements as defined in this code.

NFPA 99 National Health Care Facilities Code 4.2* Risk Assessment. Categories shall be determined by following and documenting a defined risk assessment procedure. The risk assessment must be conducted by qualified personnel.

NFPA 99 National Health Care Facilities Code The risk assessment must be conducted by qualified personnel. Who is qualified? NFPA 99 permits different parts of a facility to have different risk levels.

NFPA 99 National Health Care Facilities Code 6.3.2.2.6.2 Minimum Number of Receptacles. The number of receptacles shall be determined by the intended use of the patient care rooms in accordance with 6.3.2.2.6.2(A) through 6.3.2.2.6.2(E).

NFPA 99 National Health Care Facilities Code (A) Receptacles for Patient Bed Locations in General Care Areas (Category 2). Each patient bed location shall be provided with a minimum of eight receptacles. (Patient bed location includes wall plugs within six feet of bed)

NFPA 99 National Health Care Facilities Code NFR/LMC 19.305(7) for existing nursing facilities Two duplex or a fourplex grounding type receptacles must be provided beside the head of each bed. NFR/LMC 19.334(a)(7) for new nursing facilities Two duplex or a fourplex grounding type receptacles must be provided beside the head of each bed. Other walls must have duplex receptacles as needed for TV, radio, razors, hairdryers, clocks, and/or as required by the National Electrical Code, National Fire Protection Association (NFPA 70), which is a registered trademark of the National Fire Protection Association, Inc., Quincy, Massachusetts 02269.

NFPA 99 National Health Care Facilities Code (B) Receptacles for Patient Bed Locations in Critical Care Areas (Category 1). Each patient bed location shall be provided with a minimum of 14 receptacles.

NFPA 99 National Health Care Facilities Code 10.2.3.6 Multiple Outlet Connection. Two or more power receptacles supplied by a flexible cord shall be permitted to be used to supply power to plug-connected components of a movable equipment assembly that is rack-, table-, pedestal-, or cart-mounted, provided that all of the following conditions are met:

NFPA 99 National Health Care Facilities Code (1) The receptacles are permanently attached to the equipment assembly. (2)*The sum of the ampacity of all appliances connected to the outlets does not exceed 75 percent of the ampacity of the flexible cord supplying the outlets. (3) The ampacity of the flexible cord is in accordance with NFPA 70, National Electrical Code.

NFPA 99 National Health Care Facilities Code (4)*The electrical and mechanical integrity of the assembly is regularly verified and documented. (5)*Means are employed to ensure that additional devices or nonmedical equipment cannot be connected to the multiple outlet extension cord after leakage currents have been verified as safe.

NFPA 99 National Health Care Facilities Code NFR/LMC 19.326 (r) A facility must not use electrical extension cords or multi-receptacle plug-in adaptors as a substitute for approved wiring methods in the facility. (s) A facility may use a listed and approved surgeprotection device for equipment for which the manufacturer recommends surge protection, but in no case may the facility use a surge-protection device to increase the number of existing electrical outlets in a room.

NFPA 25 Sprinkler ITM, 2011 ed. Chapter numbers in NFPA 25 have changed. The frequencies of some inspections and tests have changed. NFPA 72 also follows this format.

NFPA 72 National Fire Alarm and Signaling, 2010 ed. The standard is renamed National Fire Alarm and Signaling Code. NFPA 72 is now organized similarly to NFPA 25, with tables that indicate the frequency of inspection, test, and maintenance activities..

NFPA 110, 2010 ed. Generators 8.3.7 Storage batteries, including electrolyte levels or battery voltage, used in connection with systems shall be inspected weekly and maintained in full compliance with manufacturer s specifications.

NFPA 110, 2010 ed. Generators 8.3.7.1 Maintenance of lead-acid batteries shall include the monthly testing and recording of electrolyte specific gravity. Battery conductance testing shall be permitted in lieu of the testing of specific gravity when applicable or warranted.

Cubicle curtains must meet NFPA 13, 2010 ed. NFPA 101 18/19.3.5.11 cubicle curtains must meet NFPA 13 for new construction and replacement after 11/01/2016 NFPA 13, 2010 edition 8.7.5.2.2.1 70% open fabric mesh to extend 22 inches down from the ceiling. (Other obstructions are 18 in Table 8.7.5.2.2 and LSC annex)

Texas Accessibility Standards 229 Windows 229.1 General. Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with 309. Each glazed opening required by an administrative authority to be operable shall comply with 309.

Texas Accessibility Standards EXCEPTION: 1. Glazed openings in residential dwelling units required to comply with 809 shall not be required to comply with 229.

Texas Accessibility Standards 106.5.54 Residential Dwelling Unit. A unit intended to be used as a residence that is primarily long-term in nature. Residential dwelling units do not include transient lodging, inpatient medical care, licensed long-term care, and detention or correctional facilities.

Texas Accessibility Standards 309.4 Operation. Operable parts shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5 pounds maximum.

Texas Accessibility Standards The 5 lb. force requirement in 309.4 applies to the operating parts (sash lock, crank handle) and to the force of opening the window, including the initial force needed to overcome the inertia of the closed window. This information has been verified by the U.S. Access Board and is consistent with the federal requirements.

Texas Accessibility Standards TDL&R has postponed compliance for drop down grab bars

NFPA 101 2012 EDITION CODE BOOK COST $98.00 + S&H http//catalog.nfpa.org 1-800-344-3555

http://www.nfpa.org/

Any questions? THANK YOU!