M Product Features Direct drive, multi-speed PSC blower motor kw 1 kw electric heat kits Blower section usable as electric heater Horizontal or vertical configuration capabilities 1" depth for easier attic access Foil-faced insulation covers the internal casing to reduce cabinet condensation Galvanized, leather grainembossed finish AHRI certified; E listed Multi-Position Multi-Speed PSC Motor Modular Blower 1½ to 5 TONS Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions...4 Airflow Data...5 Heat Kit Data... Wiring Diagram... * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 0 days of installation. Online registration is not required in California or Quebec. SS-GM www.goodmanmfg.com 11/14 Supersedes /14
Nomenclature MB 1, R,4 1 5, 00 A, A 10 1 11 Design Series Electrical MB Modular Blower 1 0-0/0/1 Motor Speed Revisions R Multi-Speed A First Series Circuit Breaker Airflow Delivered A No Circuit Breaker 0 00 CFM B Circuit Breaker 1 100 CFM 1 100 CFM Factory-installed Electric Heat 0 000 CFM 00 No Heat HKR X 0 X A 1 4 5 AA, Unit Type Revisions HKR Heat Kit for Engineering Revisions Air Handlers Phase Phase A Single Phase 0 V X No circuit breaker B Single Phase 40 V C Circuit Breaker C Single Phase 0/40 V D Three Phase 0 V* Heating Capacity @ 40 Volts E Three Phase 40 V* 0.0 kw F Three Phase 0/40 V* 05 4.5 kw G Three Phase 40 V* 0.0 kw 0.0 kw Cabinet Size (MAX) 10. kw C C Cabinet 15 14.4 kw D D Cabinet 1 1. k@ wth 150F limit X All Cabinet Sizes 0 1. kw with 10F limit 5 5.0 kw * Heat kit requires three- phase power supply Heating kw Correction Factor Supply Voltage 40 0 0 10 0 Correction Factor 1.00 0. 0.4 0. 0.5 Multiply the 40-volt heating capacity by correction factors. www.goodmanmfg.com SS-GM
Specifications Model M000AA-1 M100AA-1 M100AA-1 M000AA-1 Blower Diameter " " 10" 10" Width " " " 10" Electrical Data Voltage 0 / 0 0/0 0 / 0 0 / 0 Min Circuit Ampacity 1.. 4. Max. Overcurrent Device (Amps) 15 15 15 15 Blower Motor Horsepower (HP) ¼ ⅓ ⅓ ½ Ship Weight (Lbs.) 4 Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protection (MOP) for blower without supplemental heat installed. Refer to unit nameplate for these specifications with approved accessory heaters installed. SS-GM www.goodmanmfg.com
Dimensions Side and Front Views W H D M000* 1½" " 1" M100* 1½" " 1" M100* 1" 0" 1" M000* 4½" 0" 1" Top View 10¼" 10.15 ⅞".40 11¼" 11.0 11" 11.0 0⅛" 11¼ 11.0 1¼" 1.1 1 ½" 1.500 0.01 ½".44 MEDIUM LARGE 1½" 1" 4½" 4 www.goodmanmfg.com SS-GM
Airflow Data Speed Static M000**-* SCFM M100**-* SCFM M100**-* SCFM M000**-* SCFM High Medium Low 0.1 1,40 1,500 1,00,10 0. 1,10 1,40 1,40,00 0. 1,10 1,0 1,0 1,0 0.4 1,00 1,0 1,10 1,0 0.5 0 1,00 1,50 1,0 0. 00 1,110 1,40 1,0 0.1 00 1,0 1,540 1,0 0. 50 1,0 1,40 1,0 0. 0 1,0 1,450 1,50 0.4 40 1,00 1,400 1,50 0.5 0 1,140 1,50 1,40 0. 05 1,040 1,0 1,0 0.1 50 1,10 1,10 1,50 0. 50 1,10 1,100 1,450 0. 540 1,00 1,00 1,0 0.4 500 1,00 1,00 1,0 0.5 40 50 0 1,00 0. 0 0 0 1,00 Notes The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. Use the CFM adjustment factors of. for horizontal left,.5 for horizontal right &. for downflow orientations. SS-GM www.goodmanmfg.com 5
Heat Kit Data Models Circuit 1 Circuit Single-Point Kit Heater Amps MCA¹ MOP² Heater Amps MCA¹ MOP² MCA¹ MOP² M000AA-1 ** HKR-0* HKR-05* / 05C* HKR-0* HKR-0* / -0C* HKR-10* / -10C* 10. / 1.5 1. / 5.0 5. /. 1. / 1. 15.4 / 1 / / / 45 / 51 0 / 0 5 / 0 0 / 5 5 / 40 45/ 0 M100AA-1 ** HKR-0* HKR-05* / 05C* HKR-0* HKR-0* / -0C* HKR-10* / -10C* HKA-15C* HKA-0C* ^HKR-15* ^HKR-0* M100AA-1 ** HKR-0* HKR-05* / 05C* HKR-0* HKR-0* / -0C* HKR-10* / -10C* HKA-15C* HKA-0C* ^HKR-15* ^HKR-0* M000AA-1 ** HKR-0* HKR-05* / 05C* HKR-0* HKR-0* / -0C* HKR-10* / -10C* HKA-15C* HKA-0C* ^HKR-15* ^HKR-0* 10. / 1.5 1. / 5.0 5. /. 10. / 1.5 1. / 5.0 5. /. 10. / 1.5 1. / 5.0 5. /..0 /.0 1 / 1 4 / 0.1 / 4 5 / 4 / 5 4 / 5 4 / 5.0 /.0.0 /.0. /. 1 / 1 5. / 1 / 5 5. / 40. 4 / 5 4 / 5 4 / 5. /.. /. 4. / 4. 1 / 1 / 0 / / 41 4 / 54 4 / 54 4 / 54 4. / 4. 4. / 4. 0 / 0 5 / 0 5 / 40 5 / 40 0 / 0 0 / 0 5 / 5 40 / 45 0 / 5 0 / 5 5 / 40 40 / 45 1. /.1 40. / 4. 1. /.1 40. / 4. 1. /.1 40. / 4. 1 / 5 4 / 4 / 45.1 51 / 5 1 / 5 4 / 4 / 45.1 51 / 5 1 / 5 4 / 4 / 45.1 51 / 5 5 / 5 45 / 50 40 / 50 0 / 0 5 / 5 45 / 50 0 / 0 0 / 0 5 / 5 45 / 50 40 / 50 0 / 0 / /10 / 0/10 / 1/104 0 / 0 0 / 110 0 / 0 0 / 110 0 / 0 100 / 110 All ampacities noted above include air handler motor amps Circuit 1: Single-phase for Air Handlers / Circuit : Three-phase for HKR Heater Kits ¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.5 ² Maximum Overcurrent Protection =.5 X Motor Amps + Heater Amps * Revision level that may or may not be designated C = Circuit Breaker Option indicates Not Required HKA meets the new UL15 requirements for 15 and 0KW heaters Only applicable when HKA kits are included in table MBVC and M models www.goodmanmfg.com SS-GM
Wiring Diagram Air Handler HTR1 M1 R M 1 4 5 HTR HTR1 M M 1 R M M 4 1 4 5 HTR1 HTR HTR M1 M M M4 R1 M1 M R 1 4 5 HTR1 HTR HTR HTR4 M1 M M5 M M M4 M M R1 R 1 4 5 L1 L L1 L L1 L L1 L ONE (1) ELEMENT ROWS TWO () ELEMENT ROWS THREE () ELEMENT ROWS L1 L L1 L FOUR (4) ELEMENT ROWS NOTE: EN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM OWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S INSTALLATION INSTRUCTIONS. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE. MARK ACCOING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. SEE NOTES & GR TERMINAL OCK SHOWN FOR 50HZ MODELS ONLY SR L1 1 L GRND EQUIPMENT GROUND USE COPPER WIRE 4 5 PLF 1 4 5 0/40 VOLTS SEE NOTE 4 L1 L 1 1 PLF PLF GR G R XFMR-R XFMR-C C EBTDR SPEEDUP K1 K1 SEE NOTE 5 M1 NO COM NC M C 1 5 4V 4 SEE NOTE 1 40 TR TR RC EM 1 HI LO M1 M SEE NOTE 1 NC NO EBTDR COM COPPER POWER SUPPLY (SEE RATING PLATE) USE MIN. 5 C FIELD WIRE SEE NOTE EBTDR R 4 4V 5 5 4 PLF C EBTDR G GR IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMY IS NECESSARY USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. EM RC SR R EBTDR COMPONENT CODE TR PLF GRND EVAPORATOR MOTOR RUN CAPACITOR STRAIN RELIEF RELAY ELECTRONIC OWER TIME DELAY RELAY TRANSFORMER FEMALE PLUG CONNECTOR MALE PLUG CONNECTOR FUSE LINK THERMAL LIMIT GROUND COLOR CODE ACK RED YELLOW UE GR GREEN RPLE OWN ITE WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE RC EM THREE SPEED MOTOR WIRING (SELECT MODELS ONLY) SEE NOTE SEE NOTES & (COM) LOW (M) MEDIUM (M1) HIGH NOTES: 1. RED WIRES TO BE ON TRANSFORMER TERMINAL "" FOR 40 VOLTS AND ON TERMINAL "" FOR 0 VOLTS (TR 1) EM SPEED. SEE COMPOSITE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS RC. CONFIRM SPEED TAP SELECTED IS APPROPRIATE FOR APPLICATION. IF SPEED TAP NEEDS TO BE CHANGED, CONNECT APPROPRIATE MOTOR WIRE (RED FOR LOW, UE FOR MEDIUM, AND ACK FOR HIGH SPEED) ON "COM" CONNECTION OF THE EBTDR INACTIVE MOTOR WIRES MUST BE CONNECTED TO "M1 OR M" ON EBTDR. 4. OWN AND ITE WIRES ARE USED WITH HEAT KITS ONLY. 5. EBTDR HAS A SECOND ON DELAY EN "G" IS ENERGIZED AND A 5 SECOND OFF DELAY EN "G" IS DE-ENERGIZED.. LOW VOLTAGE FIELD WIRING TO BE N.E.C CLASS WIRES. 0140A0045-A Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. SS-GM www.goodmanmfg.com
Wiring Diagram 5 Element Heater Kit HTR1 COMPONENT CODE COLOR CODE HTR HTR HTR4 HTR5 M M4 M M M1 M M5 M 1 M10 M PC 4 R PC = PIN CONNECTOR HTR = HEATER ELEMENT = THERMAL LMT RS = RELAY/SEQUENCER TB = TERMINAL OCK CB = CIRCUIT EAKER CC = CONTACTOR = FUSE LINK EM = EVAPORATOR MOTOR EBTDR = ELEC. OWER TIME DELAY RC = RUN CAPACITOR TR = TRANSFORMER SR = STRAIN RELIEF WIRING CODE: HIGH VOLTAGE LOW VOLTAGE = ACK = UE = OWN GR = GREEN OR = ORANGE PK = PINK = RPLE = RED = ITE = YELLOW R1 R 5 NOTE: EN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM OWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER / HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW. NO MARK INDICATES NO HEAT KIT INSTALLED. FIVE (5) ELEMENT ROWS CB CB1 CB NOTE:- THIS LABEL MUST BE ATTACHED ON THE AIRHANDLER IN A PROMINENT LOCATION L1 L L1 L L1 L CB4 L1 L 0140M004-A Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 014 Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA. www.goodmanmfg.com SS-GM