esserbus -PLus maximum security, minimum costs

Similar documents
IQ8Quad. The highlight of every fire detection scenario. Fire detection technology

IQ8Control C Fire Alarm Panel

All the security you need in one housing

561-MB256 plus. Intruder alarm control panel. Performance features

New dimensions in fire detection technology FlexES control: the dawning of a flexible, trendsetting system

tools 8000 The perfect all-round tool: tools 8000 Programming and service software for alarm systems Fire detection technology

TOOLS 8000 SOFTWARE FOR THE ENTIRE LIFE CYCLE OF YOUR FIRE DETECTION SYSTEMS

IQ8Wireless. Radio technology: flexible functionality IQ8Wireless intelligent, wireless fire protection. Fire detection technology

FlexES Control Flexible solutions with the modular fire detection system

Quick Selection Guide Fire Systems LSN Periphery

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

IQ8Quad. The highlight of every fire detection scenario. Fire detection technology

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

Interbases. Sinteso FDSB221, FDSB228, FDSB229

The EN54 Part 2 and 4 Fire System

Integrated security systems. The security spectrum Systems for comprehensive building security

Viewguard Motion detctors PIR and DUAL detectors

A Soft (R)evolution. For a flexible future: modular fire alarm technology by ESSER

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

IDENTLOC. Intrusion Detection Systems. Performance Features

Availability, Reliability, False Alarm Resistance Best Practice in Fire Alarm Systems. FIRE PROTECTION OF ROLLING STOCK 2 rd March 2017

Fire Alarm Control Panel. System Maintenance and Log Book

IDENTLOC. Intrusion Detection Systems. Performance Features

561-MB48. Intruder Alarm Control Panel

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Concepts for the secure networking of large building complexes

Sita200plus. 200detectors. Single loop analogue addressable System

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Auer - Signal tower ECO Ø70 mm modular

Intelligent Security & Fire Ltd

Solution F2. Fire Alarm Control Panels one step ahead.

Cerberus FIT conventional system

FireClass. Introducing a new class of fire detection

AP200 SERIES INTELLIGENT ALARM DEVICES

AP200 SERIES INTELLIGENT ALARM DEVICES

FC722 Fire control panel

The complete conventional fire warning system

The EN54 Part 2 & 4 Fire System

Operation Instruction. VARIODYN D1 Comprio HO.GB / AA. Technical changes reserved Honeywell International Inc.

FC724 Fire control panel

FC722 Fire control panel

Clino Guard. Safety without Compromise

X10 Mini, Midi & Maxi

VTG-32E Spatial Sounder 24Vdc EN54 part 3 approved

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

intelligent solutions

VdS 5477en : (01) Key deposit boxes

TrueAlarm ES Analog Sensing

Addressable Loop Powered Visual Alarm Devices

USER MANUAL CEF AP28 CONTROL PANEL

System 800 Addressable Fire Detection & Alarm System

FC724 Fire control panel

Intelligent Security & Fire Ltd

Intelligent addressable fire alarm control panel

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

Fire control panels FC360

Fire control panel detect 3004 plus and accessories

MINERVA MX. 800 Series Ancillary Equipment

INSTRUCTION MANUAL (ATEX / IECEx)

The EN54 Part 2, 4 and 13 Fire System

intelligent fire alarm ID60series panels

ICO ADDITIONAL ACCESSORIES CO 2 INCUBATOR ICO

METAL DETECTOR MODEL NO: MD1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: /08

Touch Screen 1 loop Addressable Fire Alarm Panel

TrueAlert Addressable Notification Appliances

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

XP95 Sounder VAD Base

CEILING SPEAKER SYSTEMS F-2352C

Evolution Analogue Addressable Fire System

Ex Products Highest level of safety under the most difficult conditions

Smoke Alarm FERION 1000 O

Installation and Operating Instruction

ADDITIONAL ACCESSORIES 100% ATMOSAFE. MADE IN GERMANY.

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

An introduction to... Sigma

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

Modular Fire Panel 5000 Series Just as flexible as your plans

Instruction Manual EVA-S6 Base

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

Basic Fire Alarm SystemTraining. Arman Alnasar

Touchpoint Pro Flexible Gas Control System

Multi line separator module

INPUT / OUTPUT MINI MODULES

Solution F1. Fire Control Panels the new generation

HAWK 8000 CONNECTED BUILDING MANAGEMENT

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

Fire control panel for modernization

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

TrueAlarm Analog Sensing

CEILING SPEAKER SYSTEM F-122C INSTRUCTION MANUAL TABLE OF CONTENTS 7. REPAINTING THE SPEAKER SAFETY PRECAUTIONS... 2

Addressable Detectors & Bases

L-Series, Indoor Strobes and Horn Strobes

Ceiling air diffuser INDULTHERM INDULTHERM-e

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

Intellia Sounder Bases and Sounder Beacon Bases

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Transcription:

esserbus -PLus maximum security, minimum costs www.novar.de

The innovation The latest in ringbus technology: The esserbus -PLus supplies data, signals and power, too, for the direct operation of alarm devices on only 2 wires VdS certified. l For the first time in Germany, thanks to the esserbus -PLus, the certified and approved operation of addressable, loop-powered alarm devices on the ringbus together with fire detectors and other devices is possible. The esserbus -PLus enables alarm devices to be powered directly, tolerant of short circuits and wire breaks, from the 2-wire analog loop. In other words, all participants, including alarm devices, are connected directly to the bus. In an alarm situation, the ring loop increases the voltage to 42 volts and thus provides them with the necessary power. An alarm can therefore be signalled using completely new (wiring) paths: reliably, economically and in conformity with the relevant standards. An additional and unique quality characteristic of the esserbus -PLus is the synchronous alarm signalling function. All sweep and intermittent tones are therefore no longer distorted unrecognisably by the irregular emission of several tones in the fire compartment. For a building sector affected by fire esserbus -PLus means the alarm signal is not compromised until the device itself is destroyed by fire. Thanks to the loop technology, the warning devices in the unaffected fire compartments remain functional, even without fireproof wiring.

The status quo Ringbus technology has been used in modern alarm systems for a long time. However, separate power sources must be provided for high-current devices, such as alarm sounders. This means unnecessary costs are incurred for additional wiring, power supply units and longer installation times. l At present all internal alarm devices must be activated in conformity with various installation standards through monitored circuits. In addition, wiring that bridges more than one fire section, must satisfy the requirements for fire resilience. With conventional resources, this can only be achieved by the costly installation of a separate power unit for each fire compartment. The only exception: the wiring system is realised with powered loop technology and the alarm devices are short circuit and open circuit-tolerant. In this way it is possible to deliver sustained operation in a fire situation.

The advantages The esserbus -PLus enables versatile new system components to be used. A base sounder with an integrated fire detector base and a system sounder are available as alarm devices in conformity with EN 54-3. Both have 4 programmable and approved sounds. The esserbus -PLus offers numerous advantages in terms of security and cost-effectiveness. l Maximum planning reliability l Permanent monitoring of the alarm device l No detailed consideration of fire sections for alarm devices and their wiring paths is needed l Measures to ensure continued functionality of wiring systems with alarm devices can be dispensed with in most cases l Maximum security in cases of alarm l Savings due to lower material costs and shorter installation time l No separate power supply units for fire compartments l Synchronous alarm signalling

System components The addressable base sounder has two functions. It serves as a fully functional alarm device, which generates a uniform 360 sound pressure, and also as a mounting base for Series 9200 fire detectors. Like the base sounder, the addressable system sounder in red and white contains an isolator. Both the base sounder and the system sounder are fully integrated bus devices. Technical data common features: 4 different tones, which can be programmed using the customer data editor Warning tone to DIN 33404 Part 3 Technical data base sounder: Conforms to DIN EN 54-3, VdSapproval G 202046 Sound pressure 93 db (A)/1 m Current: < 6 ma at ring voltage, 22 ma at battery voltage Flush-mount kit available for false ceilings Up to 48 signal bases can be accommodated on one ring loop Technical data system sounder: Conforms to DIN EN 54-3, VdSapproval 202049 Sound pressure 97 db (A)/1 m Current: < 10 ma at ring voltage, 55 ma at battery voltage The sound level in the warning device is adjustable Up to 16 warning devices can be accommodated on one ring loop

plenum stoll & fischbach Communication GmbH, Düsseldorf Novar GmbH Dieselstraße 2 D-41469 Neuss Tel.: +49 (0)2137 171 Fax: +49 (0)2137 17286 Johannes-Mauthe-Straße 14 D-72458 Albstadt Tel.: +49 (0)7431 8010 Fax: +49 (0)7431 8011220 Internet: www.novar.de E-mail: info@novar.de Art. No. 797821/10.2003