HOONEAUTOMAATIKASÜSTEEMID AAR0130 2010 OSA VI-III ATS kesk ja lisaseadmed GKS VKS ÜLO KALA 1 TULEKAHJU TEATENUPP PAIGALDATAKSE IGA VÄLJUMISUKSE JUURDE PAIGALDATAKSE 1,5 M PÕRANDAPINNAST NUPU KAUGUS ANTUD EVAKUATSIOONIPIIRKONNA VÄLJUMISUKSE KAUGEIMAST PINNAST EI TOHI ÜLETADA 30 m NUPPU EI TOHI KASUTADA MILLEKSKI MUUKS KUI AINULT TULEKAHJUTEATE EDASTAMISEKS NUPUD VÕIVAD OLLA KAS PURUSTATAVA KLAASIGA VÕI VÕTMEGA TAGASTATAVAD NUPP VÕIB OLLA KAS ADRESSEERITAV VÕI MITTEADRESSEERITAV NUPPE TOODETAKSE MITMES VÄRVITOONIS: 2 PUNANE TULEHÄIRE KOLLANE GAASIKUSTUTUSE KÄIVITUS HALL SUITSUÄRASTUSE KÄIVITUS SININE TEHNILINE ALARM Page 1
KONVENTSIONAALNE KESKSEADE ESSER BMZ 80 3 ADRESSEERITAV KESKSEADE Compact housing 450 x 320 x 185 mm Compact housing plus 1 x Extension housing 450 x 640 x 185 mm Compact housing plus 2 x Extension housing 450 x 960 x 185 mm Upright cabinet Steel sheet housing 700 x 2000 x 525 mm Option for all Panels 4 Page 2
KESKSEADME JUHTIMINE Single zone indicator unit (GEA) Common display FIRE Common display PRE-ALARM 5 1 2 3 4 5 6 7 8 10 9 Common display TROUBLE Common display disconnection Alphanumeric display Key switch Operating elements Function keys and keyboard Opening for Programming connector must locked with dummy plug for ESD protection 220 V TOIDE ATS keskseade peab saama toite eraldi fiidri või eraldi automaadi kaudu. Eraldi automaat peab olema selgelt tähistatud ja teistest automaatidest eraldi. Hoonetes kus on maanduse kaitsereleed tuleb paigaldada eraldi relee ATS süsteemile. ATS toite kaitseautomaat või sulavkaitse peab olema varustatud selge punase kirjaga ATS TOIDE. Alati peb olema korralik keskseadme maandus. (näiteks ESSER keskseadmed süütavad halval maandusel kollase tule teatega ground loop fault. Kasutatada tuleks alati spetsiaalset toitekaablit näit. NYM 3 x 1.5 mm2 või sarnaste tehniliste andmetega kaablit. Paigaldus peab vastama kõigile kehtivatele elektrisüsteemide ehitusele esitatavatele nõuetele. 6 Page 3
1 2 3 4 5 6 7 8 9 0 ANDURITE JA KORDUSPANEELIDE ÜHENDAMINE 805590 (Standard) 805590 (Standard) 805591 (Relay) EP6 1 + EP6 1 Option 6 1 BR1 = n.o. (default) BR1 = n.c. OUT5 EM2 OUT5 EM2 - OUT5 BR1 2 IN4 C3 IN4 C3 IN4 C3 IN4 / B - A - A + C3 / B + B - B + FACP 8000C/M, IQ8Control, 8007 X24 FACP8000C/M, IQ8Control, 8007 Last device BR8 BR9 Last device LCD-IP FAS8000 1 2 3 4 5 6 7 8 9 0 Basic module X8 B RS485 A UB ext + GND RS485 12 V B A + - J2 J3 J4 J6 J5 J7 J2 J3 J4 J6 J5 J7 max. 1000m J2 J3 J4 J6 J5 J7 J2 J3 J4 J6 J5 J7 7 KESKSEADME ÜHENDUS SUURSILMUSEGA SUURSILMUS- MULTIFUNKSIONAALNE AHEL LISAPANEEL FDOP max. 3,5 km SUURSILMUS esserbus esserbus transponder esserbus transponder 8 3 Page 4
AVASTUSTSOONID SUURSILMUSES 9 SOPISTUS EHK SPUR A B 10 Page 5
TULETÕKKETSOON JA AVASTUSTSOON 3 2nd KORRUS floor 2 KORRUS 1st floor 1 Ground KORRUS floor 4/1 4/2 4/3 4/4 3/1 3/2 3/3 3/4 1/1 1/2 1/3 1/4 TREPIKODA Stairwell 2/3 2/2 2/1 11 TULETÕKKETSOON Fire TSOON section A A Fire TSOON section B B TULETÕKKETSOONID ON EHITUSLIKULT MÄÄRATUD PIIRKONNAD HOONES MIS ON ERALDATUD OMAVAHEL TULEPÜSIVATE VAHESEINTE, USTE JA MUUDE TÕKENDITEGA TULETÕKKETSOON EI PEA KOKKU LANGEMA AVASTUSTSOONIGA. TULETÕKKETSOONIS VÕIB OLLA MITU AVASTUSTSOONI AVASTUSTSOONIS EI VÕI OLLA MITUT TULETÕKKETSOONI 12 Page 6
SUURSILMUSE LIIKMED LRS compact/eb IQ8Control transponder transponder 4 tsooni/ 1 tsoon 2 releed transponder 32 LED transponder 12 Releed transponder FSA esserbus kustutuspaneel 8010 LED INFOPANEEL TRANSPONDER RZT 8000 Tehnilise alarmi moodul IQ8Tam 13 TEISE TOOTJA ANDURID VÕRK (RS485) FACP 3008 Gateway Indicating and operating Panel intruder / fire FACP 8000C esserbus WINMAG Serial essernet Interface essernet FOC Fibre optical cable FACP IQ8Control C FOC IAP 5008 C IAP esserbus max. 1 km Repeater max. 1 km esserbus -PLus 14 Page 7
VÕRGUÜHENDUSED essernet 1 2 3 4 5 6 7 8 not used! not used! not used! not used! L1 + L1 - L2 + L2 - essernet module essernet module L2 + L2 - L1 + L1 + L1 - L2 + L1 - L2-15 FIIBEROPTILINE VÕRK Length / attenuation refer to specified optical fibre type above Vcc RxD T R PIN 3 PIN 8 Panel 1 Panel 2 T R Vcc RxD PIN 3 PIN 8 FOC converter 784763 / 784764 +UBext. GND essernet module 1 2 3 4 Conventional essernet wiring or connection via second fibre optics cable +UBext. GND 4 essernet module 3 2 1 Fibre Optics Link FOC FOC essernet essernet Fibre Optics Link FOC FOC Fibre Optics Link 16 FOC FOC Page 8
Web-X WebCam GRAAFILINE TARKVARA Notifikation Internet PC- Netzwerk ESSER NET modem ISDN IGIS LOOP access control video matrix emergency exit control 17 RS 485 serial GRAAFILINE LIIDES 1 EKRAANIGA 2 EKRAANIGA WINMAG 18 Page 9
STANARD LIIDES PLAAN SÜNDMUSE event text and TEKST measure JA JUHISED STRUK- TUUR 19 SÜNDMUSTE LOGI 20 Page 10
ALARMSEADMED ANDUR SISSEEHITATUD SIREENI VÕI VALJUHÄÄLDIGA SPETSIAALNE ALARMSEADE 21 HELIRÕHK EFFEKTIIVNE HLIRÕHK ON ÕHUMOLEKULIDE POOLT PÕHJUSTATUD RÕHK MIS TEKIB NENDE VÕNKUMISEL (HELILAINE) INIMKÕRV SUUDAB VASTU VÕTTA HELISID RÕHUGA 0 (KUULDELÄVI) KUNI 120 SAGEDUSEL 1000 Hz. SEE VASTAB HELIRÕHU MUUTUSELE 20N/m2 (= Pa) VÕI SIIS 1: 1,000,000 HELIRÕHU JAOKS (Lihtsuse mõttes arvutataksegi helirõhku logaritmilistes suurustes( ). KESKKOND ELURUUMID ÖISEL AJAL ERALDI BÜROORUUMID AVATUD BÜROORUUMID LAOHOONED EL. TÕSTUKITEGA LAOHOONED DIISELTÕSTUKITEGA TOOTMISHOONED JA LINNATÄNAV SURUÕHU PIIKVASAR 10 M KAUGUSELT POLITSEI, TULETÕRJE JNE SIREEN 10 M REAKTIIVMOOTOR 10 M HELIRÕHU TASE 1) < 30 50 55-60 65-70 70-75 > 80 100 110 130-150 22 Page 11
MINIMAALNE HELITUGEVUS EN 54-3, OSA 4.6.2 JÄRGI KIIRGUSNURK 15 45 75 105 135 165 DIN SIGNAAL 81 89 94 94 89 81 MADAL TOON 730 Hz 81 90 95 95 90 81 KESKM. TOON 830 Hz 80 85 90 90 85 80 KÕRGE 970 Hz 82 91 96 96.0 91 82 23 HELIROHK KUULDEPUNKTIS 92 1m 72 10m ~ -20 HELIRÕHU MUUTUS SÕLTUVALT ALLIKA KAUGUSEST: L ( ) = 20 x log (r2 [m] / r1 [m]) KUS: r1 = 1m algne kaugus r2 = 20m uus kaugus ALARMSEADMETEL ON TAVALISELT ANTUD HELIRÕHK 1 M KAUGUSEL SEADMEST. IGA KORD KUI KAUGUS SUURENEB 2 X VÄHENEB HELIRÕHK 6 Db. 24 Page 12
Audible signals / Speech output Audible signals (Example) Demo Signal component Description of signal Duration [s] Tone 1 (GB) FP 1063.1 Telecoms BS 5839 Pt1-Tone 1 Alternating signal tone, Fequency 800 / 970 Hz @ 2Hz 4,00 Tone 2 (GB) FP 1063.1 Telecoms BS 5839 Pt1-Tone 2 Alternating signal tone, Frequency 800 / 970 Hz @ 1Hz 4,00 Tone 3 (GB) FP 1063.1 Telecoms BS 5839 Pt1-Tone 3 Cyclic signal tone, Frequency 970 Hz @ 1Hz 0,5 s 4,00 Speech outputs Demo Signal component Description of signal Duration [s] Phrase 6 This is a fire alarm. Please leave the building immediately by the nearest available exit. 5,27 Phrase 7 Attention please. This is an emergency. Please leave the building by the nearest available exit. 5,82 Phrase 8 An incident has been reported in the building. Please await further instructions. 4,37 Phrase 9 This is a test message. No action is required. 3,18 25 Phrase 10 The emergency is now cancelled. We apologise for any inconvenience. 4,46 PLAHVATUSOHT Ex VASTAVUS EU Explosion Protection Directive 94/9/EC-ATEX 100a 26 Page 13
PLAHVATUSOHU TSOONID TSOON 2: Alad kus plahvatusohtlik atmosfäär võib tekkida harva ja lühikeseks ajaks TSOON 1: Alad kus plahvatusohlik kontsentratsioon tekib aeg-ajalt kindlasti TSOON 0: Alad kus on kogu aeg plahvatusohtlik atmosfäär 27 KUSTUTUSSÜSTEEMID KUSTUTUSSÜSTEMID GAASKUSTUTUS VEEKUSTUTUS PULBERKUSTUTUS HALOONGAASID LOODUSL. GAASID KEEMILIS. GAASID VEESPRINKLER VEEUDU KUSTUTUS AURUGA KUSTUTUS PÜROGEENAEROSOOLID KÄSIKUSTUTID 28 Page 14
GAASKUSTUTUSSEADE KUSTUTUSAGENDI BALLOON SUITSUANDURID DÜÜSID ALARMISEADE KÄSITSI RAKENDUS SEISKAMISNUPP KESKSEADE 29 GAASKUSTUTUSSÜSTEEM 8010 8010 8010 8010 essernet esserbus Outputs 8010 8010 8010 8010 30 Page 15
31 HALONI ALTERNATIIVID CO 2 FM-200 Argonite Inergen FE-13 Veeudu Pürotehnilised 32 Page 16
CO 2 Lõhnatu Atmosfääri koostisosa Minimaalne kustutuse kontsentr. 34% 5,800 kpa Survestus Pikk tühjenemisaeg - kuni 3 minutit Balloonid nõavad palju ruumi Võib kasutada lokaalsetes süsteemides 33 FM-200 HEA ASENDUS HALONILE Kiire ja efektiivne Ohutu inimestele Pole elektrijuht - ohutu kasutada el. seadmetel Keskkonnasõbralik Pikk säilitusaeg 34 Page 17
KUSTUTUSVIISID INERTGAASID 35 VAJALIK GAASI KOGUS (MAHT) Halon 1301 CO22 Inert Gaas 36 Page 18
ARGONITE Lõhnatu Vajalik kontsentratsioon 40% Alati gaasiline 20,000 kpa Survestus Pikk tühjenemisaeg - 60 sekundit Vaja palju balloone Märgatav ruumikulu Ekspluatatsioon kallis 50% ARGON 50% NITROGEN Inert gas blend - 52% N 2, 40% Argon, 8% CO 2 Primarily acts by O 2 dilution, to 10-12%, with some 37 Page 19